The Study of characteristic comparison with inrush and fault current occurred in distribution system (배전계통에서 발생하는 돌입전류와 고장전류의 특성 비교연구)

  • 오용택;김진성
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.51-58
    • /
    • 2001
  • This paper gives a type and high-frequency waves analysis of in-rush current cab be flowed into distribution automatic machine to be installed in distribution line in order to use minimizing operation error of failure indicator to have been issue recent with obtaining high-frequency component that can be different from current. The in-rush and fault current data studied in this paper is to be surveyed actually in USA distribution system substation line of Bryan Power Company near Texas A. M University, to be occurred high impedance fault.

  • PDF

Development of Diagnostic Device for Internal Degradation in Distribution Line Using NDT Mathod (NDT 기법을 이용한 가공배전선로 내부 열화 진단장치 개발)

  • Hyun, Deuk-Chang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.8
    • /
    • pp.539-543
    • /
    • 2015
  • At present, the development of a detection device in order to prevent accidents due to wire deterioration in the distribution lines is required. Distribution line is not possible to check the internal state in a normal way because it is covered with the coating. Accordingly, various eddy current techniques that is the non-destructive test (NDT) techniques have been applied to solve this problem. In this paper, we have seen examining the characteristic change of the eddy current sensor according to the simplified shape of the sensor in order to solve the problems for the simplified shape that is generated when the simulation for the shape of the eddy current sensor.

A Study on the Superconducting Fault Current Limiter in the Simple $3{\phi}$ Power System (유도형 고온 초전도 한류기의 단순 3상 계통 적용에 대한 연구)

  • Lee, S.J.;Joo, M.S.;Lee, C.J.;Lee, J.K.;Ko, T.K.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.253-255
    • /
    • 1997
  • This paper, which is one of the researches to limit high fault-current, treats the application of an inductive High Tc Superconducting Fault Current Limiter(HTSFCL) to distribution systems. In case that the inductive HTSFCL is applied to distribution systems, this paper presented the usefulness and the commercial possibility of it through computer simulation. If the inductive HTSFCL is established in distribution systems, after fault, it limits fault current effectively within a few millisecond, so it contributes to stability of power distribution system. Especially as the system with the HTSFCL is compared with the system without it, the system is improved in stability.

  • PDF

A Novel Technique for Current Density Distribution Analysis of Solidly Modelled Coil (Solid 모델링된 코일의 전류 밀도 분포 해석을 위한 새로운 방법)

  • Im, Chang-Hwan;Kim, Hong-Gyu;Jeong, Hyeon-Gyo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.7
    • /
    • pp.483-487
    • /
    • 2000
  • The analysis of current distribution in a solidly modeled coil is very important for accurate of electric machines such as deflection yoke. In general, Modeling every coils is nearly impossible for analyzing magnetic field using the 3-D finite element method, so solidly modeled coil is usually used. Some methods have been developed for analyzing current distribution, but these methods have fatal disadvantages. The main disadvantages are that the methods cannot be applied to an arbitrary shaped coil and that they yield numerical errors. In this paper, a novel method for resolving the problems mentioned above is proposed. The new method is verified by the application to a test model and it shows a very accurate result.

  • PDF

Equal Current Distribution in Parallel Resistive SFCL Using SIPT (SIPT를 이용한 병렬 저항형 한류기의 평형전류분배)

  • 심정욱;최용선;김혜림;현옥배
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.109-112
    • /
    • 2003
  • Small impedances in the superconducting parallel circuits cause unequal distribution of the currents in the circuits. This results in quenches or losses in some superconducting parts and decrease of total transport current. This paper presents the fabrication and test results of a superconducting multi- interphase transformers (SIPT) for equal current distribution in superconducting parallel circuits. The secondary loop configuration with air core SIPT seems to be the most efficient one for the SFCL. Test results show that the SIPT can effectively make the current distribution uniform in Parallel circuits that have unequal resistances.

  • PDF

Distribution of Cathodic Protection Potential for Concrete Slab Specimens at Diverse Environmental Conditions

  • Jin, Chung-Kuk;Jeong, Jin-A
    • International Journal of Ocean System Engineering
    • /
    • v.3 no.2
    • /
    • pp.90-94
    • /
    • 2013
  • This study represents the recent laboratory results from cathodic protection (CP) system with the use of sacrificial anodes at different environmental conditions (temperature of $10^{\circ}C$ and $40^{\circ}C$). Specimens were slab type with a dimension of $500mm{\times}50mm{\times}100mm$, and concrete cover thickness were 25mm. Zinc mesh and/or bulk type anodes were installed at the center of specimen to confirm the distance that CP system has influences on the specimen to distribute uniform CP current to rebar. Two different kinds of temperature condition were applied to verify the effect of temperature. Experiments were conducted for 60 days, and the distribution of potential and current that supplied from anode to rebar was measured. From the results, CP potential was varied with time, and temperature played an important role in CP potential variations. Current was also changed with time, and current distribution could be improved by installing additional bulk type anode.

The FRTU-Based Intelligent Fault Location Determination Strategy in Ubiquitous Based Distribution Systems

  • Ko, Yun-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.192-198
    • /
    • 2008
  • This paper proposes a FRTU-based intelligent fault distance determination strategy in which each FRTU is able to avoid multiple estimations and reduce the level of estimation error by utilizing heuristic rules driven by voltage and current information collected by 1:1 communication with other FRTUs from the same zone in a ubiquitous-based distribution system. In the proposed method, each FRTU, at first, determines a fault zone and a fault path on the faulted zone based on the proposed heuristic rules which use its current data and the voltage data of its neighboring FRTUs as input data. Next, it determines the fault distance from its position based on the fault current estimated from the current data of the neighboring FRTUs. Finally, in order to prove the effectiveness of the proposed method, the diverse fault cases are simulated in several positions of the typical distribution system using the EMTP.

Optimization of Current Distributions of Electroplating on Patterned Substrates with the Auxiliary Electrode (보조 전극을 이용한 패턴된 전극에서의 전류 밀도 분포의 최적화)

  • 김남석;모화동;강탁
    • Journal of the Korean institute of surface engineering
    • /
    • v.28 no.3
    • /
    • pp.164-173
    • /
    • 1995
  • Based on the potential-theory model for secondary current distribution, we could predict the thickness distributions of electroplating on patterned substrates with the different size of the auxiliary electrode. The substrates contain lithographic patterns at each sample geometry. Each sample geometry had different current distribution at the same condition except the size of the auxiliary electrodes. The size effect of the auxiliary electrode on thickness distribution of electrodeposition on patterned electrode was investigated in a series of experiments. Copper was galvanostatically deposited from an acid-sulfate solution in a reciprocating paddle cell. The thickness distributions of the workpiece scale measured by profilometry across the specimen were in good agreement with the current distribution predicted by boundary element method.

  • PDF

Specifications of 22.9kV HTS cables and FCLs considering protection systems in Korean power distribution system (국내계통 보호시스템을 고려한 22.9kV 초전도케이블/한류기 설계사양 제안)

  • Lee, Seung-Ryul;Park, Jong-Young;Yoon, Jae-Young;Lee, Byong-Jun;Yang, Byeong-Mo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.3
    • /
    • pp.50-54
    • /
    • 2009
  • In Korea, 22.9kV 50MVA HTS (High Temperature Superconducting) cables and 630A/3kA hybrid SFCLs (Superconducting Fault Current Limiters) have been or are being developed by LS Cable, LS Industrial System, and Korea Electric Power Research Institute. They will be installed at Icheon 154kV Substation for real-power-distribution-system operation in 2010. This paper proposes specification of current limiting resistor/reactor for the SFCL and fault current condition of the HTS cable for applying the superconducting devices to Korean power distribution system, from the viewpoint of power system protection.

Transport Current Distribution of a SmBCO Coated Conductor

  • Lee, Jae-Young;Yoo, Jae-Un;Lee, Sang-Moo;Jung, Ye-Hyun;Youm, Do-Jun;Kim, Ho-Sup;Ha, Hong-Soo;Oh, Sang-Soo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.4
    • /
    • pp.7-10
    • /
    • 2007
  • The transport current distribution across the tape width of a SmBCO coated conductor was investigated. The current distribution was estimated by applying an inversion process to the field distribution measured in the vicinity of the tape by using a scanning Hall probe method. The obtained result is well consistent with one predicted by the Bean model, however, at the edges the current are not constant and do not generally plateau, on the contrary.