• 제목/요약/키워드: current condition

검색결과 5,093건 처리시간 0.045초

석면함유 건축물의 관찰조사를 통한 실내공기 중 섬유 농도 변화 요인 추정 (Estimation of Factors Influencing Airborne Fiber Concentrations through an Observation Survey of Asbestos-containing Materials in Buildings)

  • 이승철;김부욱;이광용;신용철
    • 한국산업보건학회지
    • /
    • 제25권2호
    • /
    • pp.174-183
    • /
    • 2015
  • Objectives: The objective of this study is the estimation of factors influencing airborne fiber concentrations by means of an observation survey of asbestos-containing materials in buildings. Methods: Forty-five samples were collected from four commercial buildings by NIOSH Method 7400 and classified according to current condition, potential activity, construction year, and operations and maintenance(O&M). Results: Airborne fiber concentrations by current condition(classified as good, fair and poor) were significantly different(p<0.05). Concentrations by potential activity were significantly different among groups(p<0.05), and those from the low activity group were higher than those from the middle activity group. Based on construction year, airborne fiber concentrations from the decade of the 1990's were higher than those from the 1960's. When O&M status was considered, airborne fiber concentrations from 1960's buildings were lower than those buildings not operated and maintained(p<0.01), because dust generation was influenced by O&M status. It was found that airborne fiber concentrations were related to current condition and potential activity via regression analysis, but the coefficient of determination was low. Also, correlation analysis showed that the higher the potential activity, the more current condition is worsened, but the relationship was not significant(r=-0.455, p>0.05). Conclusions: Airborne fiber concentrations in asbestos-containing buildings had weak relationships with current condition and potential activity.

3상 초전도케이블의 불평형 부하운전시 열.전류 저항에 의한 운전특성연구 (A Study on the operational characteristics of Thermal.Current Resistance of 3 phase HTS Cable under Unbalanced load operation)

  • 이근준;황시돌;이현철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.189-1-190-1
    • /
    • 2008
  • A high temperature superconducting(HTS) power cable is available for high capacity current in normal condition. But resistance was appeared to operate unbalance load by thermal current characteristic. This characteristic of HTS power cable used to design for unstated condition. And than, It used to understand and analyze characteristic of power cable thermal and critical current. This study appeared that quench resistance reason from shield and former current rise to superconductor(SC) current. The resistance of SC occurred that the cable temperature rise to fault current after decreased critical current. The quench resistance of SC increased in temperature or decreased in critical current. So the quench resistance of SC correlated with resistance of both shield and former current. It need to sufficiently influenced the parameters of HTS cable design.

  • PDF

로고스키 코일을 이용한 액체 질소 내에서 전류측정 (Current measurement in LN2 using Rogowski coil)

  • 최용선;차상도;황시돌;최효상
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.239-241
    • /
    • 2003
  • When superconductors are combined with normal conductor as a parallel electric circuit, imbalance of the applied current is happened. For the accurate parameters of the circuit, it is needed to measure the current of the circuit under LN2 condition. In this case, the measurement using Rogowski coil, which is not that affected by changing temperature, can be a method. In this study, using 2 Rogowski coil, the measurement of current was conducted under the condition that is room and LN2 temperature respectively.

  • PDF

보관상태가 자동차용 고분자전해질 연료전지의 성능 감소에 미치는 영향 (Effects of Storage Condition on Degradation of Automotive Polymer Electrolyte Membrane Fuel Cells)

  • 조은애
    • 전기화학회지
    • /
    • 제13권4호
    • /
    • pp.277-282
    • /
    • 2010
  • 자동차용 고분자전해질 연료전지의 열화는 시동 또는 정지 시에 'reverse-current condition'이라 불리는 현상에 의해 촉진된다. 연료전지 자동차의 운전 종료 후 장시간동안 주차를 해 두면, 대기 중의 공기가 스택 내로 서서히 유입되어 시간이 경과함에 따라 산소분압이 점차 높아져 궁극적으로는 연료극과 공기극의 유로가 모두 공기로 충진된다. 이때 재시동하면서 연료극으로 수소가 공급되면, 연료극 유로 내에 수소와 공기가 공존하게 되고, 연료극에 공기가 존재하는 부위의 공기극에 1.4 V 이상의 높은 전압이 발생하는데, 이를 reverse-current condition 이라고 하며 공기극의 탄소담지체와 백금 촉매 산화의 원인으로 작용한다. 본 연구에서는 재시동시 스택 내에 존재하는 산소의 농도에 따른 열화 현상을 규명하고자 하였다.

Diode and MOSFET Properties of Trench-Gate-Type Super-Barrier Rectifier with P-Body Implantation Condition for Power System Application

  • Won, Jong Il;Park, Kun Sik;Cho, Doo Hyung;Koo, Jin Gun;Kim, Sang Gi;Lee, Jin Ho
    • ETRI Journal
    • /
    • 제38권2호
    • /
    • pp.244-251
    • /
    • 2016
  • In this paper, we investigate the electrical characteristics of two trench-gate-type super-barrier rectifiers (TSBRs) under different p-body implantation conditions (low and high). Also, design considerations for the TSBRs are discussed in this paper. The TSBRs' electrical properties depend strongly on their respective p-body implantation conditions. In the case of the TSBR with a low p-body implantation condition, it exhibits MOSFET-like properties, such as a low forward voltage ($V_F$) drop, high reverse leakage current, and a low peak reverse recovery current owing to a majority carrier operation. However, in the case of the TSBR with a high p-body implantation condition, it exhibits pn junction diode.like properties, such as a high $V_F$, low reverse leakage current, and high peak reverse recovery current owing to a minority carrier operation. As a result, the TSBR with a low p-body implantation condition is capable of operating as a MOSFET, and the TSBR with a high p-body implantation condition is capable of operating as either a pn junction diode or a MOSFET, but not both at the same time.

Differential Changes of ATP-sensitive Potassium Channel Current after Hypoxia-reperfusion Treatment in Mouse Neuroblastoma 2a (N2a) Cell

  • Park, Ji-Ho
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제6권4호
    • /
    • pp.183-186
    • /
    • 2002
  • Ischemic damage is one of the most serious problems. The openers of KATP channel have been suggested to have an effect to limit the ischemic damage. However, it is not yet clear how KATP channels of a cell correspond to hypoxic damage. To address the question, N2a cells were exposed to two different hypoxic conditions as follows: 6 hours hypoxia followed by 3 hours reperfusion and 12 hours hypoxia followed by 3 hours reperfusion. As the results, 6 hours hypoxic treatment increased glibenclamide- sensitive basal $K_{ATP}$ current activity (approximately 6.5-fold at 0 mV test potential) when compared with nomoxic condition. In contrast, 12 hours hypoxic treatment induced a relatively smaller change in the $K_{ATP}$ current density (2.5-fold at 0 mV test potential). Additionally, in experiments where $K_{ATP}$ channels were opened using diazoxide, the hypoxia for 6 hours significantly increased the current density in comparison to control condition (p<0.001). Interestingly, the augmentation in the $K_{ATP}$ current density reduced after exposure to the 12 hours hypoxic condition (p<0.001). Taken together, these results suggest that $K_{ATP}$ channels appear to be recruited more in cells exposed to the 6 hours hypoxic condition and they may play a protective role against hypoxia-reperfusion damage within the time range.

옥외 애자용 재료의 표면 전기전도특성 (Properties of Surface Electrical Conduction in Materials for Outdoor Insulator)

  • 박영국;강성화;정수현;이운석;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.207-210
    • /
    • 1998
  • Surface electrical conduction in insulator is most important factor to assess the insulation performances of outdoor insulating materials. In this paper, contamination performance of the widely used materials for outdoor insulator - porcelain, EPDM, Silicone rubber - were discussed by measuring properties of average leakage current and scintillation discharge pulses under artificial contamination conditions. The artificial contaminations used were deionized distilled water fog, 0.5wt% NaCl salt fog of light pollution and 2wt% NaCl salt fog of medium pollution. The average leakage current was appeared linearly with applied voltage at dry and clean surface condition. The magnitude of leakage current was almost same at different kinds of samples. In case of deionized distilled water fog, the characteristics of leakage current and applied voltage was most different to that in case of dry and clean condition. In case of salt fog pollution condition. The leakage current was increased above critical voltage. The scintillation discharges were also activated at the level the leakage current and scintillation discharges were increased with increasing pollution degree. The resistance to pollution properties of silicone rubber appeared excellent among them.

  • PDF

풍력터빈 PM형 동기발전기의 와전류손실과 열 해석에 관한 연구 (A Study on Rotor Eddy Current Loss and Thermal Analysis of PM Synchronous Generator for Wind Turbine)

  • 최만수;장영학;박태식;정문선;문채주
    • 전기학회논문지
    • /
    • 제63권11호
    • /
    • pp.1575-1581
    • /
    • 2014
  • In this paper, eddy current loss, iron loss and heat transfer of PMSG with 2,000kW capacities were analyzed for wind turbine. The PMSG with 3 split magnet was analyzed using ansoft maxwell commercial program and, generator was tested by Back to Back converter with no load condition at laboratory. Rotor surface temperature was measured by Pt100 sensors for investigating heat transfer from rotor to atmosphere. The simulation results shows 27.4kW eddy current loss in no load condition and 50.2kW eddy current loss in rated load condition with 3 split magnet, and also shows 4.3kW iron loss in no load condition and 7.3kW iron loss rated load condition. The heat transfer coefficient of convection between rotor surface and atmosphere was investigated by $9.6W/m^2{\cdot}K$. Therefore the heat transfer from rotor to atmosphere was about 17kW(54%) and from rotor to air-gap was about 14.6kW(46%) in no load condition. It is identified that the cooling system for stator have to include the 46% of iron loss, and heat dissipation structure of rotor surface have to be suggested and designed for efficiency improvement of generator.

새로운 영전압 스위칭 방식을 이용한 고효율 하프-브릿지 컨버터 (New Zero-Voltage-Switching Method for High Efficiency Half-Bridge Converter)

  • 이성세;문건우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.25-27
    • /
    • 2006
  • This paper proposes a new full ZVS-range asymmetrical half bridge converter. It uses the variable transient current build-up technique with the load variations. The current build-up is accomplished by using the secondary synchronous switch control. Due to the blocking capacitor in secondary side, the voltage applied to leakage inductor varies with the load variations during current build-up period. Therefore, the unnecessary current build-up of leakage inductor current in heavy load condition is prevented and more current build-up in medium and light load condition is achieved for ZVS operation. That is, the variant current build-up with the load variation is accomplished for the ZVS operation. Furthermore, the DC offset of the transformer magnetizing current is also eliminated and the utilization of magnetic core is maximized.

  • PDF

전류형 Z-Source 컨버터를 이용한 새로운 LED 전류 밸런싱 기법 (New LED Current Balancing Scheme Using C-Fed Z-Source Converter)

  • 홍다헌;차헌녕
    • 전력전자학회논문지
    • /
    • 제26권1호
    • /
    • pp.9-15
    • /
    • 2021
  • In multi-string light-emitting diode (LED) driver system, current balancing is crucial because the brightness of LED is directly related to its forward current. This paper presents a novel LED current balancing topology using current-fed Z-source converter. With the proposed structure, currents flowing through two LED strings are automatically balanced owing to the charge-balance condition on capacitors. Operation of the proposed converter is simple and the proposed converter uses only one active switch and one diode. Moreover, low-side gate driving can be used to operate the active switch. To verify the operation of the proposed LED current balancing converter, a prototype is built and tested with different numbers of LEDs.