• Title/Summary/Keyword: current condition

Search Result 5,113, Processing Time 0.032 seconds

Current Control of a Single-phase PWM Converter under the Distorted Source Voltage and Frequency Condition (전원 전압 왜곡과 주파수 변동 시 단상 PWM 컨버터의 전류 제어)

  • Ahn, Chang-Heon;Kim, Sang-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.4
    • /
    • pp.356-362
    • /
    • 2015
  • This paper presents a current control strategy in the synchronous reference frame for a single-phase PWM converter, which ensures sinusoidal input current control under the distorted source voltage and frequency condition. Given that the distorted source voltage distorts the phase angle for PWM converter control, the input current contains the same harmonics as the source voltage. Aside from the distorted voltage, the variation in source frequency reduces the performance of input current control. To achieve sinusoidal input current control under the distorted source voltage and frequency condition, this paper proposes a compensation strategy of current reference with the distortion component extracted from the phase angle and a detection strategy of frequency variation from the output of a synchronous reference frame phase-lock loop. The experimental results confirm the validity of the proposed method under the distorted source voltage and frequency condition.

The surface discharge performance of silicone rubber in the Salt fog test (Salt fog 시험에서 silicone rubber에서 발생하는 방전 전류의 특성)

  • 강성화;박영국;이광우;김완수;이용회
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.565-569
    • /
    • 1999
  • In these days, the silicone insulators have been increasingly studied and applied for outdoor insulators because it has superior characteristics than porcelain and glass insulators, which have been used for outdoor insulators. First of all, The excellent performance of the silicone rubber in polluted and wet conditions is attributed to the ability of the material to maintain the hydrophobicity of the surface in the presence of severe contamination and wet conditions. This is because of the presence of low molecular weight mobile fluid in the silicone rubber which diffuses to the surface and to above the contamination layer. But, the leakage current and some surface discharge occurs on surface of the composite polymeric insulation materials when the insulator is used for a long time with severe contaminative condition and it can lead the contamination flashover. So the leakage current and the discharge current are important to estimate the condition of the silicone rubber surface. In this paper, the average leakage current, the relation of surface discharge current and phase angle were study to investigate electrical conduction of silicone rubber surface with the salt fog condition.

  • PDF

The Current Condition and Improvement Plan of Accessibility for the Disabled in the Catholic Churches - Focused on the Parish Churches Located in Yuseong-Gu, Daejeon Metropolitan City - (가톨릭 성당건축의 장애인 편의시설 설치현황 및 개선방안 - 대전광역시 유성구 소재 본당을 중심으로 -)

  • Park, Sang-Hyun
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.4
    • /
    • pp.231-239
    • /
    • 2014
  • This study is regarding the accessibility for the disabled in the catholic churches. The purpose is to check the current condition of the accessibility for the disabled and to suggest the improvement plans targeted at 10 churches located in Yuseong-gu, Daejeon metropolitan city. Especially the current condition of the obligations and recommendations specified in the accessibility enhancement law for the disabled was performed through field investigation. Firstly, the accessibility for the disabled of each church was evaluated qualitatively as well as quantitatively. And then sequential improvement plans divided into three stages were suggested. Above all, the parish, management authority of catholic churches should establish medium and long-term plans besides legal standards. Even though the scope of this research was limited to catholic churches of certain areas, the result of this research is expected to help investigation the current condition of the accessibility for the disabled and to suggest the improvement plans in other catholic churches.

MAGNETIC FLUX-CURRENT SURFACES OF MAGNETOHYDROSTATIC EQUILIBRIA

  • Choe, G.S.;Jang, Minhwan
    • Journal of The Korean Astronomical Society
    • /
    • v.46 no.6
    • /
    • pp.261-268
    • /
    • 2013
  • Magnetohydrostatic equilibria, in which the Lorentz force, the plasma pressure force and the gravitational force balance out to zero, are widely adopted as the zeroth order states of many astrophysical plasma structures. A magnetic flux-current surface is a surface, in which both magnetic field lines and current lines lie. We for the first time derive the necessary and sufficient condition for existence of magnetic flux-current surfaces in magnetohydrostatic equilibria. It is also shown that the existence of flux-current surfaces is a necessary (but not sufficient) condition for the ratio of gravity-aligned components of current density and magnetic field to be constant along each field line. However, its necessary and sufficient condition is found to be very restrictive. This finding gives a significant constraint in modeling solar coronal magnetic fields as force-free fields using photospheric magnetic field observations.

Transport Behaviour of Electroactive Species in Ionic Compounds: A Focus on Li Diffusion through Transition Metal Oxide in Current Flowing Condition

  • Lee, Sung-Jai;Pyun, Su-Il
    • Journal of the Korean Electrochemical Society
    • /
    • v.12 no.1
    • /
    • pp.1-10
    • /
    • 2009
  • This article reviewed transport behaviours of electroactive species in ionic compounds, focusing on chemical diffusion of Li through the transition metal oxide in a current flowing condition. For this purpose, a distinction has been first briefly made between migration and diffusion with respect to current, driving force and charge of electroactive species considered. Then, the equations for chemical diffusion are derived theoretically in open-circuit and current flowing conditions. Finally, the experimental methods such as ac impedance spectroscopy and current (potential) transient techniques are described in details for characterising chemical diffusion. In addition, the role of the thermodynamic enhancement factor in chemical diffusion is discussed.

The Actual Condition and Problems of Current Shrouds (현행수의의 실태 및 문제점)

  • 조효숙;안지원
    • Journal of the Korean Society of Costume
    • /
    • v.52 no.3
    • /
    • pp.123-137
    • /
    • 2002
  • The purpose of this study is to analyze the actual condition and problems of current ready-made shrouds. Current shrouds were formed after the 20th century and therefore are quite apart from its traditional precedents of Chosun Dynasty. In this respect, several problems can be pointed out. 1. The use of natural colored hemp as a primary textile of current shrouds is far from our tradition. Silk, ramie, and cotton have to be used together with hemp. Also, more variety of colors can be used other than natural white. 2. The size of ready-made shrouds has to be categorized at least into three: large, medium and small 3. The pattern and sowing method of Dopo(도포) and Wonsam(원삼) should be corrected in line with those of the traditional Dopo(도포) and Wonsam(원삼). 4. The design and items of current ready-made shrouds have to break away from the standardized convention and should seek more of a variety that our rich tradition provide. 5. The rational index should be suggested so that consumers can compared the quality and price of ready-made shrouds available at their hands.

Metal Transfer Characteristics of Aluminium under Pulsed Current Metal Inert Gas Welding (알루미늄의 펄스 전류 미그 용접)

  • 최재호;최병도;김용석
    • Journal of Welding and Joining
    • /
    • v.20 no.5
    • /
    • pp.127-133
    • /
    • 2002
  • In this study, metal transfer characteristics in pulsed current metal inert gas (MIG) welding of aluminum was investigated. Based on the metal transfer characteristics from direct current electrode negative MIG welding, the one drop per one pulse(ODOP) condition was predicted and compared with experimental data. The results indicated that experimental pulse range for the ODOP condition is wider than that predicted from the DCEP MIG welding data. In addition, more stable metal trnasfer behavior was obtained at the higher end of the ODOP condition.

A Study on the Optimum Cooling Condition of the Underground Power Transmission Cable Equipped with a Separate Pipe Cooling System (간접냉각이 이용된 지중송전케이블의 적정냉각조건에 관한 연구)

  • Park, M.H;Che, G.S.;Seo, J.Y.;Kim, J.G.;Lee, Jae-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.4
    • /
    • pp.263-276
    • /
    • 1992
  • The transmission current in a power cable is determined under the condition of separate pipe cooling. To this end, the thermal analysis is conducted with the standard condition of separate pipe cooling system, which constitutes one of the underground power transmission system. The changes of transmission current in a power cable with respect to the variation of temperatures and flow rates of inlet cooling water as well as the cooling spans are also determined. As a consequnce, the corresponding transmission current is shown to vary within allowable limit, resulting in the linear variation of the current for most of the cable routes. The abrupt changes of current, however, for the given flow rate of inlet cooling water in some cooling span lead to the adverse effects on the smooth current transmission within the underground power transmission system. In practice, it is expected that the desinging of the separate pipe cooling system in conjunction with the evaluation of system capacity should take into account the effects of design condition on the inlet cooling flow rate.

  • PDF

Analysis of Operational Characteristics of Separated Three-Phase Flux-Lock SFCL (삼상 분리형 자속구속형 전류제한기의 동작 특성 분석)

  • Doo, Seung-Gyu;Du, Ho-Ik;Park, Chung-Ryul;Kim, Min-Ju;Kim, Yong-Jin;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.289-289
    • /
    • 2008
  • We investigated the operational characteristics of the separated three-phase flux-lock type superconducting fault current limiter (SFCL). The single-phase lock type SFCL consist of two coils, which are wound in parallel through an iron core. The high-$T_c$ superconducting(HSTC) thin film connected in series with secondary coil. The separated three-phase flux-lock type SFCL consist of three single-phase flux-lock type SFCL. In a normal condition, the SFCL is not operate. When a fault occurs, the current of a HSTC thin film exceeds its critical current by fault current, the resistance of the HSTC thin film generated. Therefore fault current was limited by SFCL. The separated three-phase flux-lock type SFCL are operated in fault condition such as the the single line-to-ground fault, the double line-to-ground fault and the triple line-to-ground fault. The experimental results, the SFCL operational characteristics was dependent on fault condition.

  • PDF

Study on the Fire Risk in Locked-Rotor Condition of Single-Phase Induction Motor (단상 유도전동기의 구속운전조건에서 화재 위험성에 관한 연구)

  • Ji, Hong-Keun;Song, Jae-Yong
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.64-71
    • /
    • 2020
  • In this paper, the fire risk of a single-phase induction motor under a locked-rotor condition is described. In general, motor failure occurs in the locked-rotor condition owing to poor rotation of the rotor. Large inrush current flows when a motor starts, which is approximately 2-15 times larger than the rated current. In a single-phase induction motor under the locked-rotor condition, a large current that corresponds to the inrush current flows continuously through the stator winding. Such an overcurrent rises the temperature inside the stator winding, and thus the insulating material may catch fire. In this study, the restrained operating condition of the single-phase induction motor was simulated. Further, the degree of the overcurrent and temperature rise in the stator winding was measured. The experimental results, confirmed that the overcurrent was seven times larger than the rated current and the fire commenced at a temperature of approximately 300 ℃ inside the stator winding.