• Title/Summary/Keyword: current body image

Search Result 120, Processing Time 0.029 seconds

Numerical Analysis of Three-Dimensional Magnetic Resonance Current Density Imaging (MRCDI) (3차원 자기공명 전류밀도 영상법의 수치적 해석)

  • B.I. Lee;S.H. Oh;E.J. Woo;G. Khang;S.Y. Lee;M.H. Cho;O. Kwon;J.R. Yoon;J.K. Seo
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.4
    • /
    • pp.269-279
    • /
    • 2002
  • When we inject a current into an electrically conducting subject such as a human body, voltage and current density distributions are formed inside the subject. The current density within the subject and injection current in the lead wires generate a magnetic field. This magnetic flux density within the subject distorts phase of spin-echo magnetic resonance images. In Magnetic Resonance Current Density Imaging (MRCDI) technique, we obtain internal magnetic flux density images and produce current density images from $\bigtriangledown{\times}B/\mu_\theta$. This internal information is used in Magnetic Resonance Electrical Impedance Tomography (MREIT) where we try to reconstruct a cross-sectional resistivity image of a subject. This paper describes numerical techniques of computing voltage. current density, and magnetic flux density within a subject due to an injection current. We use the Finite Element Method (FEM) and Biot-Savart law to calculate these variables from three-dimensional models with different internal resistivity distributions. The numerical analysis techniques described in this paper are used in the design of MRCDI experiments and also image reconstruction a1gorithms for MREIT.

A Study on Body Image Recognition, Food Habits, Food Behaviors and Nutrient Intake according to the Obesity Index of Elementary Children in Changwon (창원시 일부 초등학교 고학년의 비만도에 따른 체형인식도, 식습관, 식행동 및 영양섭취상태에 대한 비교연구)

  • 이경혜;황권증;허은실
    • Korean Journal of Community Nutrition
    • /
    • v.6 no.4
    • /
    • pp.577-591
    • /
    • 2001
  • This study was carried out to investigate the difference of the body image recognition, food habits, food behaviors and nutrient intake according to the obesity index(underweight-, normal-, obese group) in children(aged 10.8 ys, 47 boys, 33 girls). Subjects were eva1uated based an anthrofometric measurement and questionnaries including food record diary in Changwon. The results are summarized as follows. The weight, BMI, body fat, waist circumference, hip circumference and birth weight except height showed a significant difference between the three groups(p<0.001). The waist and hip circumference showed the possibility of being a predictor of obesity in children. The children's obesity was related to mother's weight(p<0.01), but not to father's. Ninety percent of the obese group, 47.8% of the normal group, and 37.8% of the underweight group preferred a thinner figure than their current status. The underweight group did more exercise regularly than the other groups. The underweight and obese groups had more irregular meal times and foster eating habits compared to the normal group. Most of subjects(89.9%) had an overeating habit, and tole ratio of the overeating habit increased with obesity. Fifty five percent of the subjects clad the habit of skipping meals, mainly breakfast. 46.8% of the subjects ate snacks more than twice per a day, the underweight and obese groups had snacks more of than the normal group. The preferred snack was 'cookies'and 'fruits & juices'. 53.8% of the subjects had a prejudice for special food(especially 'pulses'(37.9%) and 'vegetables'(31.0%)). The assessment scores of food behaviors was relatively low in most of the subjects. Most nutrient intakes, except vitamin B$_1$, C and phosphate, were lower than those of Korean RDA. The nutrient intake of the normal group was higher than the underweight and obese groups. The results of this study showed some nutritional problems, which indicates the need for nutritional management for the children. To educate children, who are able to change their food habits and lifestyle, each means to help healthy growth and to help them become healthy adults.

  • PDF

The Comparison of User Preference on Domestic versus a Foreign 3D Virtual Try-On System (국내외 3차원 가상 의복 착장시스템에 대한 선호도 비교)

  • Do, Wol-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.7
    • /
    • pp.1184-1196
    • /
    • 2010
  • Several applications of body scanning technology have been commercialized or are currently under development. The virtual fit from 3D scans is most advanced form of virtual try-on. This article is an analysis of the comparison of user preferences for domestic versus foreign 3D virtual try-on systems. For this study, domestic i-Fashion Mall (www.ifashionmall.co.kr) and a Canadian company, My Virtual Model (www.mvm.com) were selected as the most representative online retailers that offer a virtual try-on system. The respondents were comprised of 70 Korean female college students in the age group 20-29. A five point Likert scale was used to evaluate the degree of the preference of virtual avatar and try-on images. T-test, cross table, and a chi-square independence test were conducted for data analysis. The results are as follow. 1. The representation about current looks according to each virtual fit image indicates that MVM is more accurate than i-Fashion Mall. 2. About decision confidence, respondents have decision confidence in i-Fashion Mall in the case of the avatar image; however, respondents have confidence in MVM or the fit image. 3. There were no significant differences in among waist size groups in accuracy, trust of each avatar image, while there were significant differences among waist size groups in the accuracy and trust of each virtual fit image. 4. About ease of use, respondents answered that i-Fashion Mall is superior to MVM. 5. The respondents prioritized the ‘fitting report’ of i-Fashion Mall and ‘Weight loss’ of MVM over other functionalities.

Entrance Skin Dose and Image Quality Evaluation According to Use Grid Radiography for the Extremity in FPD System (FPD System에서 상.하지 촬영 시 격자에 따른 환자 선량 및 화질 평가)

  • Lee, In-Ja;Yeo, Young-Bok;Lee, Tae-Sung
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.341-348
    • /
    • 2010
  • By accessing the current status of FPD system use in the hospitals located in Seoul and Gyeonggi Province as well as the entrance skin dose and the image quality evaluation realized by C-D Phantom, and the image assessment by the medical professionals regarding the radiography for the extremity, the following results were derived. 1. According to the evaluation made in the actual use of FPD system (12 machines), the grid ratio varied from 8:1 to 13:1, and 6 machines used the grid ratio with 12:1, realizing the largest number. Among the machines, there were 8 machines that allowed a removable grid while 3 machines did use a removable grid (25.0%). 2. When it came to the equipments used for the experiment, it showed that the amount of the entrance skin dose increased from 4.13 times up to 4.79 times with the grid use. 3. The difference in the entrance skin dose depending on the changes in the exposure condition(0.5times or 2.0times) was not significantly different regardless of the patients' thickness. 4. In terms of the image quality depending on C-D Phantom, the grid use was distinguished well. However, the images were well distinguishable as the exposure condition got increased. 5. In the clinical assessment, the grid use was less effective for the Hand PA, which was considered to shoot a thin body part. It was evaluated that the grid use was preferred for the Knee AP, which was shooting for a relatively thick body part. Nonetheless, 3 out of 5 people said that they would not use the grid if the entrance skin dose to reduced.

The Organ projection system using holographic lens (홀로렌즈를 이용한 장기 투영 시스템)

  • Kim, dong young;Kim, dong hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.83-85
    • /
    • 2017
  • Generally, the current organ projection systems are the MRI and the CT. The MRI and the CT, (MRI) allow the surgeon to see the internal organs without incising the human body. However, since the images generated by the machines are 2D, it is difficult for doctors to observe the internal organs in three dimension. In this paper, we develop the augmented projection system for internal organs by using the augmented reality technology. The developed system shows the internal organs of the body using a holographic lens as a stereoscopic image and allows for doctors to examine the internal organs in detail.

  • PDF

Images of Costumes in Science Fiction Movies (공상 과학 영화에 나타난 복식이미지)

  • 김민자
    • Journal of the Korean Society of Costume
    • /
    • v.50
    • /
    • pp.51-68
    • /
    • 2000
  • This study is intended to examine the common features of costume images in science-fiction (SF) movies that deal with current socio-cultural situations by examining their themes and tones about the future it can be generally concluded that costume images of SF movies are divided into two patterns : one inheriting traditional styles constructed on linear progress and the other based on dismantiling the tradition. this analysis is made through the research of actual cinematic contexts on the common features of multiple styles shaping the two patterns of costume images. The results can be summarized as the following: The former is related with the future built up on the basis of belief in reasonal progress rooted in the Enlightenment reasonable plan for ideal social order and strong faith in uniformity. So It shows functional uniformity disregarding wasteful competitiveness in consumption and luxuriousness and clothing that has the aesthetic value of purity without emphasizing human body or sensuality are presented. On the other hand SF movies which show the uncertain costume image as the meaning of dismantling of tradition take up a rather critical view of assumption that society can move toward utopian future as it searches future images in the notion of hetero-topia by emphasizing pluralism consequently as for clothing diversity and uncertainty in post-modern style are presented destroying modernistic dichotomy and the assumption of Utopian clothing made in the notion of modern progressivism.

  • PDF

Measurement of Breast Volume and the Area of Breast Base Using 3D Measurement System (3차원 측정시스템을 이용한 유방부피 및 유저면적의 측정)

  • 이현영;이옥경;홍경희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.2
    • /
    • pp.270-276
    • /
    • 2003
  • Methodology was suggested to analyze breast volume, base area of breast bulk. and surface area of breast using the 3D measurement system. Thirty-seven middle-aged (30s-40s) women wearing 80A brassiere were participated in this study. Image of the upper body was captured by Phase-shifting moire. The posture of the subject was adjusted to get the full image of the right breast. Rapidform 2001 was used for the analysis of the images. The mean breast volume was 547.0㎤ and mean base area of breast bulk was 235. I$\textrm{cm}^2$ It was also found that the volume(r=0.169) and surface area of breast(r=10.242) were loosely correlated with the circumference difference between top and under breast. Therefore, it is noted that current selection criterion of cup size based on the difference in the two kinds of breast circumference is inadequate. The result of this study is expected to contribute to the design of ergonomic brassiere as well as surgical operations in the medical field.

Design of External Coil System for Reducing Artifact of MR Image due to Implantable Hearing Aid (이식형 보청기에 의한 자기공명 영상의 인공음영 축소를 위한 외부 코일 시스템 설계)

  • Ahn, Hyoung Jun;Lim, Hyung-Gyu;Kim, Myoung Nam;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.2
    • /
    • pp.375-385
    • /
    • 2016
  • Recently, several implantable hearing aids such as cochlear implant, middle ear implant, etc., which have a module receiving power and signal from outside the body, are frequently used to treat the hearing impaired patients. Most of implantable hearing aids are adopted permanent magnet pairs to couple between internal and external devices for the enhancement of power transmission. Generally, the internal device which containing the magnet in the center of receiving coil is implanted under the skin of human temporal bone. In case of MRI scanning of a patient with the implantable hearing aid, however, homogeneous magnetic fields of the MRI might be interfered by the implanted magnet. For the above reasons, the MR image is degraded by large area of artifact, so that diagnostics are almost impossible in deteriorated region. In this paper, we proposed an external coil system that can reduce the artifact of MR image due to the internal coupling magnet. By finite element analysis estimating area of MR artifact according to varying current and shape of the external coil, optimal coil parameters were extracted. Finally, the effectiveness of the proposed external coil system was verified by confirming the artifact at real MRI scan.

MREIT of Postmortem Swine Legs using Carbon-hydrogel Electrodes

  • Minhas, Atul S.;Jeong, Woo-Chul;Kim, Young-Tae;Kim, Hyung-Joong;Lee, Tae-Hwi;Woo, Eung-Je
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.6
    • /
    • pp.436-442
    • /
    • 2008
  • Magnetic resonance electrical impedance tomography(MREIT) has been suggested to produce cross-sectional conductivity images of an electrically conducting object such as the human body. In most previous studies, recessed electrodes have been used to inject imaging currents into the object. An MRI scanner was used to capture induced magnetic flux density data inside the object and a conductivity image reconstruction algorithm was applied to the data. This paper reports the performance of a thin and flexible carbon-hydrogel electrode that replaces the bulky and rigid recessed electrode in previous studies. The new carbon-hydrogel electrode produces a negligible amount of artifacts in MR and conductivity images and significantly simplifies the experimental procedure. We can fabricate the electrode in different shapes and sizes. Adding a layer of conductive adhesive, we can easily attach the electrode on an irregular surface with an excellent contact. Using a pair of carbon-hydrogel electrodes with a large contact area, we may inject an imaging current with increased amplitude primarily due to a reduced average current density underneath the electrodes. Before we apply the new electrode to a human subject, we evaluated its performance by conducting MREIT imaging experiments of five swine legs. Reconstructed conductivity images of the swine legs show a good contrast among different muscles and bones. We suggest a future study of human experiments using the carbon-hydrogel electrode following the guideline proposed in this paper.

A Study on the Effective Marketing Implementation through Face Recognition Technology in Smart Digital Signage

  • Cha, jin-gil;Kim, Seong-Kweon
    • International journal of advanced smart convergence
    • /
    • v.11 no.3
    • /
    • pp.72-78
    • /
    • 2022
  • The aim of this research is to improve the effectiveness of digital media advertising because current advertisements -in digital signage - indiscriminately appeals to the general public rather than to a specific target. In order to deliver efficient and customized advertisement information, an IoT human body detection sensor mounted on digital signage detected human faces and then classified them firstly by gender. The digital signage here is a smart digital signage that can analyze facial signals, discriminate them based on patterns, and apply the extracted data by displaying the corresponding information to the user. In addition, by identifying the customer's location approaching the smart digital signage and displaying the optimized content information for the customer's location through an algorithm, the digital signage can dramatize the advertisement Thus, this is a study meant forimproving information efficiency while reducing noise and driving power waste generated from unnecessary digital information reproduction.