• Title/Summary/Keyword: crown restoration

Search Result 303, Processing Time 0.019 seconds

Selection of all ceramic crown (완전 도재관의 선택)

  • Lee, Seung-Kyu
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.24 no.2
    • /
    • pp.122-133
    • /
    • 2015
  • The requirements for the successful treatment of all-ceramic restorations are not so different from the ones of conventional restorations. "The provisional restoration followed by an adequate tooth reduction" and "the accurately fitting prostheses with corresponding to final impression" can be the examples of them. Nevertheless, the one which all-ceramic restorations are distinguished from conventional restorations is the additional procedure of so called "bonding". In addition to the application of resin cement between "inner surface of restoration and outer surface of abutment", bonding technology can be also applied to the treatment process of "Post and Core" in particular if the abutments are non-vital teeth. Core build-up for all-ceramic crown is conducted with fiber post and tooth colored composite by considering the properties of the restorations transmitting light. We know well that a vital abutment is easier than a non-vital one to get the targeted goals for clinical success in connection with esthetics and structure. The creation of "Post and Core" with bonding technique is a decisive factor for a long-term success if the abutment is non-vital tooth with dentinal collapse. I would like to share my clinical experience about "post & core build-up and all-ceramic restoration bonding" out of several success strategies of all-ceramic crown with this review article.

The prognosis of splinted restoration of the most-distal implants in the posterior region

  • Lee, Jong-Bin;Kim, Man-Yong;Kim, Chang-Sung;Kim, Young-Taek
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.6
    • /
    • pp.494-503
    • /
    • 2016
  • PURPOSE. The aim of this study was to compare the efficacies of two-implant splinting (2-IS) and single-implant restoration (1-IR) in the first and second molar regions over a mean functional loading period (FLP) of 40 months, and to propose the appropriate clinical considerations for the splinting technique. MATERIALS AND METHODS. The following clinical factors were examined in the 1-IR and 2-IS groups based on the total hospital records of the patients: sex, mean age, implant location, FLP, bone grafting, clinical crown-implant ratio, crown height space, and horizontal distance. The mechanical complications [i.e., screw loosening (SL), screw fracture, crown fracture, and repeated SL] and biological complications [i.e., peri-implant mucositis (PM) and peri-implantitis (PI)] were also evaluated for each patient. In analysis of two groups, the chi-square test and Student's t-test were used to identify the relationship between clinical factors and complication rates. The optimal cutoff value for the FLP based on complications was evaluated using receiver operating characteristics analysis. RESULTS. In total, 234 patients with 408 implants that had been placed during 2005 - 2014 were investigated. The incident rates of SL (P<.001), PM (P=.002), and PI (P=.046) differed significantly between the 1-IR and 2-IS groups. The FLP was the only meaningful clinical factor for mechanical and biological complication rates in 2-IS. CONCLUSION. The mechanical complication rates were lower for 2-IS than for 1-IR, while the biological complication rates were higher for 2-IS. FLP of 39.80 and 46.57 months were the reference follow-up periods for preventing biological and mechanical complications, respectively.

Effect of the marginal position of prosthesis on stress distribution of teeth with abfraction lesion using finite element analysis (보철물 변연의 위치가 abfraction된 치아의 응력 분포에 미치는 영향에 대한 유한요소법적 분석)

  • Kim, Myeong-Hyeon;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.202-210
    • /
    • 2014
  • Purpose: The aim of this study was to evaluate the stress concentration and distribution whether restoring the cavity or not while restoring with metal ceramic crown on tooth with abfraction lesion using finite element analysis. Materials and methods: Maxillary first premolar was selected and made a total of 10 finite element model. Model 1 was natural tooth; Model 2 was tooth with metal ceramic crown restoration which margin was positioned above 2 mm from CEJ; Model 3 was tooth with metal ceramic crown restoration which margin was positioned on CEJ; Model 4 was natural tooth which has abfraction lesion; Model 5 and 6 had abfraction lesion and the other condition was same as model 2 and 3, respectively; Model 7 was natural tooth which had abfraction lesion restored with composite resin; Model 8 and 9 was tooth with metal ceramic crown after restoring on abfraction lesion with composite resin; Model 10 was restored tooth on abfraction lesion with composite resin and metal ceramic crown restoration which margin is positioned on lower border of abfraction lesion. Load A and Load B was also designed. Von Mises value was evaluated on each point. Results: Under load A or load B, on tooth with abfraction lesion, stress was concentrated on the apex of lesion. Under load A or load B, on tooth that abfraction lesion was restored with composite resin, the stress value was reduced on the apex. Conclusion: In case of abfraction lesion was restored with composite resin, the stress was concentrated on the apical border of restored cavity regardless of marginal position. It was favorable to place crown margin on the enamel for restoring with metal ceramic crown.

MARGINAL FIT OF THE AURO GALVANO CROWN SYSTEM MADE USING THE ELECTROFORMING TECHNIQUE

  • Yang Jae-Ho;Song Tae-Jin;Han Jung-Suk;Lee Jae-Bong;Lee Sun-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.6
    • /
    • pp.679-684
    • /
    • 2004
  • Statement of problem. There have been few studies about the marginal fit of Auro Galvano Crowns. Purpose. The purpose of this study was to compare the marginal fit of the anterior single restorations. Material and methods. The in vitro marginal discrepancies of metal-ceramic, Auro Galvano Crown and coping were evaluated and compared. The Auro Gavano Crowns were made from one extracted maxillary central incisor prepared by milling machine. 30crowns per each system were fabricated. Measurements of a crown were recorded at 50 points that were randomly selected for marginal gap evaluation. Parametric statistical analysis was performed for the results. Results. Mean marginal gap dimensions and standard deviations at the marginal opening for the anterior single crowns were $74{\pm}21{\mu}m$ for the control (metal-ceramic restoration), $45{\pm}11{\mu}m$ for Auro Galvano Crown coping, and $51{\pm}9{\mu}m$ for the Auro Galvano Crown. Conclusions. Auro Calvano Crown showed significantly smaller (P<.05) marginal gap than the control. Ceramic application did not significantly affected the marginal fit of Auro Galvano Crown. (P>.05)

Comparison of Partial Pulpotomy in Permanent Molars Using Different Pulp Capping Agents and Restoration Materials (치수복조재와 최종수복재에 따른 대구치 부분치수절단술의 비교)

  • Lee, Jimi;Lee, Nanyoung;Lee, Sangho;Jih, Myeongkwan
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.2
    • /
    • pp.148-156
    • /
    • 2020
  • The purpose of this study was to compare the success rates of two pulp capping materials, Biodentine™ and RetroMTA®, used for partial pulpotomy in permanent molars after carious exposures and to compare the final restorative outcome of using composite resin to that of using a stainless steel crown. We studied children who were diagnosed with dental caries of permanent molars and underwent partial pulpotomy. The patients were followed up for more than 1 year. Clinical and radiographic evaluation were used to evaluate the success of each treatment. Fisher's exact test was used to compare the outcomes of two groups. For pulp capping agents, the success rate of using RetroMTA® was lower than that of using Biodentine™(p < 0.05). Final restoration with composite resin was less successful than restoration with an stainless steel crown(p < 0.05). In combination of pulp capping agents and final restoration material, RetroMTA®-composite resin shows the lowest success rate(p < 0.05).

Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system

  • Lee, Wan-Sun;Lee, Du-Hyeong;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.265-270
    • /
    • 2017
  • PURPOSE. This study is to evaluate the internal fit of the crown manufactured by CAD/CAM milling method and 3D printing method. MATERIALS AND METHODS. The master model was fabricated with stainless steel by using CNC machine and the work model was created from the vinyl-polysiloxane impression. After scanning the working model, the design software is used to design the crown. The saved STL file is used on the CAD/CAM milling method and two types of 3D printing method to produce 10 interim crowns per group. Internal discrepancy measurement uses the silicon replica method and the measured data are analyzed with One-way ANOVA to verify the statistic significance. RESULTS. The discrepancy means (standard deviation) of the 3 groups are $171.6\;(97.4){\mu}m$ for the crown manufactured by the milling system and 149.1 (65.9) and $91.1\;(36.4){\mu}m$, respectively, for the crowns manufactured with the two types of 3D printing system. There was a statistically significant difference and the 3D printing system group showed more outstanding value than the milling system group. CONCLUSION. The marginal and internal fit of the interim restoration has more outstanding 3D printing method than the CAD/CAM milling method. Therefore, the 3D printing method is considered as applicable for not only the interim restoration production, but also in the dental prosthesis production with a higher level of completion.

Study on the Production Method of the Gilt-bronze Crown Excavated from Ipjeom-ri Tomb 1, Iksan (익산 입점리 1호분 출토 금동관의 제작기법 연구)

  • Lee, Youngbeom
    • Conservation Science in Museum
    • /
    • v.20
    • /
    • pp.1-12
    • /
    • 2018
  • In February 1986, a high-school student reported the discovery of fragments of gilt-bronze burial goods on a mountainside behind a village in Ipjeom-ri, Ungpo-myeon in Iksan. The National Research Institute of Cultural Heritage immediately undertook an excavation. Unfortunately, gilt-bronze relics including a band and vertical decorations for a crown, a hat, and shoes had already been collected from Ipjeom-ri Tomb 1 by the student who found them before they could be properly excavated. Also, the interior of the stone chamber of the tomb had been severely disturbed by the time of excavation, making it difficult to identify the precise original locations of the relics within the tomb and hindering the reassembly of the fragments of the gilt-bronze crown. After conservation treatment, the gilt-bronze hat, shoes, and other relics were restored to their original forms and researchers were able to identify incised designs of a three-legged bonghwang(鳳凰), fish scales, lotus flowers, and other motifs. This study presents the major features of the fragments of gilt-bronze relics from Ipjeom-ri Tomb 1 and the methods of their production in order to provide basic material for their restoration and allow the eventual restoration of the giltbronze crown to its original condition.

Rehabilitation using endocrown for fracture of maxillary anterior teeth due to trauma in adolescence: a case report (청소년기 외상으로 인한 상악 전치부 파절 시 Endocrown을 이용한 수복: 증례 보고)

  • So-Yeon Lee;Sung-Ae Son;Jeong-Kil Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.1
    • /
    • pp.24-30
    • /
    • 2024
  • Complicated crown fractures of maxillary anterior teeth caused by trauma in adolescence can cause functional and aesthetic problems. For crown fractures with pulp exposure, various restorative methods can be considered depending on the amount of remaining tooth structure. Direct resin restorations are the most traditional and effective method, but they are likely to discolor and break over time. Fixed prosthesis have a high possibility of re-restoration due to marginal disharmony due to tooth movement during the growth period, and restorations using post which are mainly performed for extensive crown fractures increase the risk of root perforation and root fracture. However, endocrown is an integrated structure that gains retention force from the pulp space, enabling effective reconstruction from a biomechanical perspective and providing advantages in restoring function and aesthetics. Therefore, endocrown can be considered as a restoration method for complicated crown fractures caused by trauma in adolescence.

ESTHETIC RESTORATION OF FRACTURED IMMATURE PERMANENT INCISORS (파절된 미성숙 영구 전치의 수복)

  • Lee, In-Young;Kim, Hyun-Jung;Kim, Young-Jin;Nam, Sun-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.1
    • /
    • pp.126-132
    • /
    • 2009
  • Injuries of permanent teeth by trauma occur frequently in childhood and adolescence. Crown fractures are as frequent as 25-76% and especially maxillary incisors are prone to fractures. There have been numerous efforts to achieve both aesthetically and functionally satisfying restoration. When a mature tooth is fractured, porcelain crown or laminate veneer could be a choice of prosthodontic treatment. However, in a case of immature permanent incisor fracture, prosthodontic treatment is more complicated due to the immaturity of the tooth. Moreover, if endodontic treatment is accompanied with the prosthodontic treatment, the treatment period is prolonged. In the past, restoration using an orthodontic band, a ready-made crown, or glass ionomer cement did not exhibit esthetically satisfying result. As restorational materials have been improved, now more esthetic restoration is possible by reattaching fractured fragments or light-curing composite resin restoration. We reports cases of patients with fractured maxillary incisors and their successful treatment results through reattachment of fractured fragments and composite resin restoration.

  • PDF