• Title/Summary/Keyword: cross-talk

Search Result 251, Processing Time 0.028 seconds

System Identification of Nonlinear System using Local Time Delayed Recurrent Neural Network (지역시간지연 순환형 신경회로망을 이용한 비선형 시스템 규명)

  • Chong, K.T.;Hong, D.P.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.6
    • /
    • pp.120-127
    • /
    • 1995
  • A nonlinear empirical state-space model of the Artificial Neural Network(ANN) has been developed. The nonlinear model structure incorporates characteristic, so as to enable identification of the transient response, as well as the steady-state response of a dynamic system. A hybrid feedfoward/feedback neural network, namely a Local Time Delayed Recurrent Multi-layer Perception(RMLP), is the model structure developed in this paper. RMLP is used to identify nonlinear dynamic system in an input/output sense. The feedfoward protion of the network architecture provides with the well-known curve fitting factor, while local recurrent and cross-talk connections provides the dynamics of the system. A dynamic learning algorithm is used to train the proposed network in a supervised manner. The derived dynamic learning algorithm exhibit a computationally desirable characteristic; both network sweep involved in the algorithm are performed forward, enhancing its parallel implementation. RMLP state-space and its associate learning algorithm is demonstrated through a simple examples. The simulation results are very encouraging.

  • PDF

Feasibility of Applying Mixed-Reality to Enhancing Safety Risk Communication in Construction Workplaces

  • Olorunfemi, Abiodun;Dai, Fei;Peng, Weibing
    • International conference on construction engineering and project management
    • /
    • 2017.10a
    • /
    • pp.225-234
    • /
    • 2017
  • Mixed-reality technologies have proven to be valuable in many architecture, engineering and construction / facilities management (AEC/FM) applications. However, its potential of being adapted to facilitate hazard identification and risk communication in construction workplaces has yet to be fully explored. This paper makes an attempt to evaluate the feasibility of applying mixed-reality to enhancing safety risk communication in construction workplaces. Experiments have been designed in which Microsoft HoloLens® together with a developed application will be used to intervene in the practice of jobsite risk communication. A cross-sectional survey will then be followed to examine the effectiveness and acceptability of this technology through analysis on data collected from participants in the construction industry. The preliminary results show that this emerging HoloLens® technology, compared to the traditional communication methods (i.e., phone calls, walking up people and talk, and video conferencing), facilitates accurate, prompt safety communication on construction sites. Such findings signify the potential of applying mixed-reality to safety performance enhancement in the construction industry.

  • PDF

Theoretical Development and Experimental Investigation of Underwater Acoustic Communication for Multiple Receiving Locations Based on the Adaptive Time-Reversal Processing (다중수신 수중음향통신을 위한 적응 시계열반전처리 기법의 이론연구와 실험적 검증)

  • Shin Kee-Cheol;Byun Yang-Hun;Kim Jea-Soo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.5
    • /
    • pp.239-245
    • /
    • 2006
  • Time-reversal processing (TRP) has been shown as an effective way to focus in both time and space. The temporal focusing properties have been used extensively in underwater acoustics communications. Recently. adaptive time-reversal processing (ATRP) was applied to the simultaneous multiple focusing in an ocean waveguide. In this study. multiple focusing with ATRP is extended to the underwater acoustic communication algorithm for multiple receiving locations. The developed algorithm is applied to the underwater acoustic communication to show, via simulation and real data, that the simultaneous self-equalization at multiple receiving locations is achieved.

A Study on a Phase-encoded Multiplexing Method in Holographic Memory System (홀로그래픽 메모리시스템에서 위상 다중화 인코딩에 관한 연구)

  • Cho, Byung-Chul;Kim, Kyu-Tae;Gil, Sang-Keun;Kim, Eun-Soo
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.10
    • /
    • pp.51-60
    • /
    • 1999
  • For an effective phase-multiplexing in holographic memory system, four types of phase code used as reference beam are generated. In case of $32 {\times} 32$ address beam, a phase error with 0%, 5%, 10% 15%, 20%, and 25% error rate, is purposely added to the real phase values in order to consider the practical SLM's nonlinear characteristics of phase modulation in computer simulation, cross talks and SNRs are comparatively analysed for these phase-codes by the auto and cross-correlation. Pseudo-Random(PSR) Phase Code has the lowest cross-correlation mean value of 0.067 among four types of Phase Code, which means the SNR of the PSR is higher than other Phase Codes. Also, the standard deviation of the PSR phase code indicating the degree of recalled data degradation is the lowest value of 0.0113.

  • PDF

Differences in the Needs According to Gender or Major for Development of the Prevention Program for Dating Violence of University Students (대학생의 데이트폭력 예방 프로그램 개발을 위한 성별 및 전공계열에 따른 요구의 차이)

  • Kim, Rae-Eun;Koo, Sang-Mee
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.1
    • /
    • pp.178-186
    • /
    • 2020
  • The purpose of this study is to analyze whether there is a difference in the needs of the prevention program for dating violence according to the gender and major of University students. The subjects of the study were the humanities, social science and health care students in U university, which included 220 male students, 131 female students, and a total of 351 students. The research tool produced and surveyed the questionnaire about the timing, content and method of education about prevention of dating violence through the review of previous studies. For data analysis, independent sample t-test and cross-analysis were conducted to analyze the differences in the demands for dating violence prevention programs according to the gender and major of University students. The results of the study were as follows: First, there was a significant difference in the demands of teaching methods of dating violence prevention programs according to the gender in personal counseling and experience activities using open KakaoTalk. The women were significantly higher than men in all sub-factors of dating violence prevention programs. Second, there was a significant difference in the demands of teaching methods of dating violence prevention programs according to the major in personal counseling and experience activities using open KakaoTalk. The health care students were significantly higher in all sub-factors of dating violence prevention programs than in humanities and social sciences students.

Effect of CH4 Concentration on the Dielectric Properties of SiOC(-H) Film Deposited by PECVD (CH4 농도 변화가 저유전 SiOC(-H) 박막의 유전특성에 미치는 효과)

  • Shin, Dong-Hee;Kim, Jong-Hoon;Lim, Dae-Soon;Kim, Chan-Bae
    • Korean Journal of Materials Research
    • /
    • v.19 no.2
    • /
    • pp.90-94
    • /
    • 2009
  • The development of low-k materials is essential for modern semiconductor processes to reduce the cross-talk, signal delay and capacitance between multiple layers. The effect of the $CH_4$ concentration on the formation of SiOC(-H) films and their dielectric characteristics were investigated. SiOC(-H) thin films were deposited on Si(100)/$SiO_2$/Ti/Pt substrates by plasma-enhanced chemical vapor deposition (PECVD) with $SiH_4$, $CO_2$ and $CH_4$ gas mixtures. After the deposition, the SiOC(-H) thin films were annealed in an Ar atmosphere using rapid thermal annealing (RTA) for 30min. The electrical properties of the SiOC(-H) films were then measured using an impedance analyzer. The dielectric constant decreased as the $CH_4$ concentration of low-k SiOC(-H) thin film increased. The decrease in the dielectric constant was explained in terms of the decrease of the ionic polarization due to the increase of the relative carbon content. The spectrum via Fourier transform infrared (FT-IR) spectroscopy showed a variety of bonding configurations, including Si-O-Si, H-Si-O, Si-$(CH_3)_2$, Si-$CH_3$ and $CH_x$ in the absorbance mode over the range from 650 to $4000\;cm^{-1}$. The results showed that dielectric properties with different $CH_4$ concentrations are closely related to the (Si-$CH_3$)/[(Si-$CH_3$)+(Si-O)] ratio.

Interaction of DEMS with H-terminated Si(001) surface : a first principles (DEMS와 H-terminated Si (001) 표면의 상호작용: 제일원리연구)

  • Kim, Dae-Hyun;Kim, Dae-Hee;Park, So-Yeon;Seo, Hwa-Il;Lee, Do-Hyeong;Kim, Yeong-Cheol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.117-117
    • /
    • 2009
  • 최근 고집적화 구조는 저항(resistance)과 정전용량 (capacitance)에 의한 신호 지연 (RC delay) 증가로 인한 혼선 (cross-talk noise)과 전력소모 (power dissipation)등의 문제를 발생시킨다. 칩 성능에 영향을 미치는 제한인자를 최소화하기 위해서는 저저항 배선 금속과 저유전상수 (low-k)의 층간 절연막 (IMD, intermetal dielectric) 물질이 필요하다. 최근 PECVD (plasma enhanced chemical vapor deposition)를 이용하여 증착시킨 유기살리케이트 (OSG, organosilicate glass)는 가장 유망한 저유전상수 물질로 각광받고 있다. 본 연구에서는 제일원리 연구를 통하여 OSG의 전구체 중에 하나인 DEMS 문자를 모델링하고, 에너지적으로 가장 안정한 구조를 찾아서 각 원자 간의 결합에 따른 해리에너지 (dissociation energy)를 계산하고, DEMS가 H-terminated Si 표면과 반응하는 기구에 대해 고찰하였다. 최적화된 DEMS 분자의 구조를 찾았고 DEMS 분자가 결합이 깨져 조각 분자군으로 될 때의 에너지들을 계산하였다. 계산된 해리에너지로부터 DEMS 분자의 O 원자와 C분자의 결합이 깨져서 $C_2H_5$를 조각 분자군으로 생성할 확률이 총 8가지의 경우에서 가장 높다는 것을 알 수 있었다. 8 가지의 해리된 DEMS 조각 분자군들이 H-terminated Si 표면과 반응할 때의 반응에너지를 계산한 결과 표면의 Si 원자와 DEMS 분자에서 $C_2H_5$가 해리되어 생성된 조각 분자군의 O 원자가 결합을 하고 부산물로 $C_2H_6$를 생성하는 반응이 가장 선호된다는 것을 알 수 있었다. DEMS 분자로 증착시킨 OSG에 대하여 제일원리법을 이용하여 계산한 연구는 보고된 바 없기 때문에, DEMS 분자의 각 원자 간의 해리에너지와 Si 기판과의 반응에너지는 추후 연구개발의 중요한 기초 자료가 될 수 있다.

  • PDF

1.55 μm polarization mode splitter utilizing two mode interference of Ti:LiNbO3 optical waveguides (1.55 μm Ti:LiNbO3 광도파로의 두 모드 간섭을 이용한 편광모드 분리기)

  • 김정희;정기조;정홍식;이한영
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.1
    • /
    • pp.32-37
    • /
    • 2002
  • Passive polarization mode splitters at λ= 1.55 ${\mu}{\textrm}{m}$ were designed and fabricated based on Ti:x-cut LiNbO$_3$ single-mode optical waveguide and two-mode interference theory. The splitting ratio with waveguide width 8 ${\mu}{\textrm}{m}$, branching angle 0.55$^{\circ}$ and interfering length 470 ${\mu}{\textrm}{m}$ showed 16.18 dB, 21.25 dB for TE and TM input polarization modes, respectively. Polarization cross-talk of -16.28 dB and -21.28 dB for TE and TM modes was achieved. Total insertion losses of 2.24 dB/cm (TE) and 2.41 dB/cm (TM) were also measured. The devices operated nearly wavelength independently over a range or 30 nm.

Factors that Affect the Hearing Thresholds of Call Center Workers (콜센터 근로자의 청력역치에 영향을 미치는 요인)

  • Yoo, Kye Mook;Kim, Kab Bae;Chung, Kwang Jae;Kim, Kyoo Sang
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.21 no.3
    • /
    • pp.168-176
    • /
    • 2011
  • Objectives: Hundreds of thousands of call center workers are wearing an acoustic device for their businesses, such as telemarketing and customer counseling, and the number of the workers are increasing sharply. Because call center workers always talk to dozens of customers over the headset, they would be placed under the state of a higher risk with their hearing ability. The purpose of this study is to investigate factors that affect the hearing thresholds for the call center workers. Methods: This study investigated hearing losses of 101 workers of 5 call centers in Korea by executing puretone audiometry and self-administered questionnaires. A cross table analysis was processed to compare gender differences between male and female. Male and female hearing thresholds were compared with the Students' t-test, and one-way ANOVA was conducted to observe the difference between non-occupational and occupational characteristics in 2, 3, 4, 6, and 8 kHz hearing thresholds for the female workers. Additionally, multiple regression analysis was conducted to find the factors that affect the 4 kHz hearing thresholds. Results and Conclusions: Male hearing thresholds were higher than those of female except for 8 kHz. In the group having an ear related disease, hearing threshold of male left ear was highly affected rather than that of female in 4 kHz. There were significant differences in the variables of alcohol drinking (2 kHz) and headset volume (8 kHz) in both ears. While this study does not show any significant factors that affect the hearing thresholds in the occupational characteristics, the gender and the previous ear related diseases, non-occupational characteristics, were found as the factors in 4 kHz. It is suggested that the more detailed survey be performed to identify the occupational factors that affect the hearing thresholds in the call center workers based on the result derived from this study.

Implementation of Acoustic Echo Canceller with A Post-processor Using A Fixed-Point DSP (고정 소수점 DSP를 이용한 후처리기를 가지는 음향 반향제거기의 구현)

  • 이영호;박장식;박주성;손경식
    • Journal of Korea Multimedia Society
    • /
    • v.3 no.3
    • /
    • pp.263-271
    • /
    • 2000
  • In this paper, an acoustic echo canceller(AEC) is implemented by ADSP-2181. This AEC uses a noise robust adaptive algorithm and a postprocessing method which attenuates residual echo using cross-correlation between estimated error signal and microphone input signal. We propose new postprocessing method that uses two thresholds to prevent signal distortion after postprocessing and to improve the performance of AEC without extra computational burden. Through experiments using a 16 bit fixed-point DSP board (ADSP-2181 EZ-KIT Lite board), it is shown that the noise robust adaptive algorithm performs well in the double-talk situations and the convergence speed is comparable to NLMS. Using the postprocessor, ERLE is improved about 20 dB. As a result, the AEC with a postprocessor shows better performance than conventional ones.

  • PDF