• 제목/요약/키워드: cross-flow microfiltration

검색결과 12건 처리시간 0.018초

Purification During Crossflow Electromicrofiltration of Fermentation Broth

  • Park Young G.
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제9권6호
    • /
    • pp.500-505
    • /
    • 2004
  • The present study was to investigate the purification of a fermentation broth by an electromicrofiltration membrane. Microfiltration runs with a crude and a centrifuged broth, with solution of particles recovered from centrifugation and with permeates from microfiltration experiments were thus compared. Microfiltration performances were governed by colloids and small particles that induced sharp initial flux declines. For these results, the evolution of the overall membrane resistance was increased by $80\%$ in comparison with the electromicrofiltration membrane. The main focus of this study was set on the enhancement of the filtrate flux by an electric field. This pressure electrofiltration leads to a drastic improvement of the filtration by $100\%$ and the filtration time was thereby reduced. Pressure electrofiltration serves as an inter­esting alternative to the cross-flow filtration and it effectively separates advantageous constitu­ents such as amino acids and biopolymers from a fermentation broth. They were equally main­tained during the microelectrofiltration, although they were significantly reduced by $45\%$ by the microfiltration without the application of an electric field. Accordingly, since the electrofiltration membrane was provided more permeability, this study experimentally demonstrates that the permeability inside a membrane can be controlled using an electric field.

Microfiltration of Chlorella sp.: Influence of material and membrane pore size

  • Ahmad, A.L.;Yasin, N.H. Mat;Derek, C.J.C.;Lim, J.K.
    • Membrane and Water Treatment
    • /
    • 제4권2호
    • /
    • pp.143-155
    • /
    • 2013
  • Four membranes were used to separate Chlorella sp. from their culture medium in cross-flow microfiltration (MF) experiments: cellulose acetate (CA), cellulose nitrate (CN), polypropylene (PP) and polyvinylidenefluoride (PVDF). It was found that the hydrophilic CA and CN membranes with a pore size of 1.2 ${\mu}m$ exhibited the best performances among all the membranes in terms of permeation flux. The hydrophobicity of each membrane material was determined by measuring the angle between the water (liquid) and membrane (solid). Contact angle measurements showed that deionized (DI) water had almost adsorbed onto the surfaces of the CA and CN membranes, which gave $0.00^{\circ}$ contact angle values. The PP and PVDF membranes were more hydrophobic, giving contact angle values of $95.97^{\circ}$ and $126.63^{\circ}$, respectively. Although the pure water flux increased with increasing pore diameter (0.8 < 1.2 < 3.0 ${\mu}m$) in hydrophilic CA and CN membranes, the best performance in term of filtration rate for filtering a microalgae suspension was attained by membranes with a pore size of 1.2 ${\mu}m$. The fouled membrane pore sizes and pore blocking were inspected using a scanning electron microscope (SEM). MF with large pore diameters was more sensitive to fouling that contributed to intermediate blocking, where the size of the membrane pores is almost equivalent to that of cells.

정밀여과에서 불균일 입자에 의한 막오염에 관한 3차원 모사 연구 (Three Dimensional Simulation of the Deposition of Multi-dispersed Particles during Cross-flow Microfiltration)

  • 윤성훈;이정학;김규진
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1997년도 춘계 총회 및 학술발표회
    • /
    • pp.48-49
    • /
    • 1997
  • 막분리에 있어 막오염 현상은 공정의 경제성을 좌우하는 중요한 요소이다. 이에따라 막오염에 따른 플럭스 변화를 예측하기 위한 다양한 방법을 시도하고 있다. 그러나 대부분의 동력학적 해석식들은 여과초기에만 적용되는 단점이 있었다. 최근에는 콜로이드 입자에 의한 막오염 과정을 그대로 모사하여 여과개시 후 상당한 시간 후의 플럭스를 예측하려는 시도를 하고 있다. 그러나 지금까지 연구된 모델들은 2차원입자를 사용하거나 혹은 단일입자분포를 갖는 3차원입자를 사용한 것들이었다. 2차원 모사인 경우 세공막힘현상을 설명할 수 없으며 3차원 단일분포 입자시스템은 현실과는 거리가 먼 단점이 있었다. 이에따라 본 연구에서는 다중분포(multi-disperse)를 갖는 입자의 정밀여과 (microfiltration)를 모사하여 시간에 따른 플럭스의 변화를 예측해 보고자 하였다.

  • PDF

벤토나이트 현탁액에 의한 정밀여과 막의 오염특성 (Fouling Behavior of Bentonite Colloidal Suspensions in Microfiltration)

  • 남석태;한명진
    • 멤브레인
    • /
    • 제18권1호
    • /
    • pp.53-64
    • /
    • 2008
  • 벤토나이트 현탁액에 의한 폴리에틸렌 정밀여과 모세관 막의 오염특성에 대하여 검토하였다. 막오염의 윈인은 막표면 위에서 생성되는 케익층의 성장과 입자들이 세공을 막는 표준 및 완전세공막힘 때문이었으며, 막오염은 이들 세 가지 오염형태가 동시에 발생하지만 케익여과오염에 의해 크게 지배를 받는다. 운전압력 $1.0kg/cm^2$에서 총 막오염에 대한 성분오염의 비율은 표준세공막힘 3.36%, 완전세공막힘 3.18% 그리고 케익여과오염 93.46%이었다. 현탁액의 농도가 1000 ppm인 경우에는 완전세공막힘 1.71%, 표준세공막힘 1.90% 그리고 케익여과오염이 96.39%이었으며, 운전초기에 총 오염의 96.14%가 발생했다. 총 오염에 대한 케익여과의 영향은 세공이 $0.34{\mu}m$막에서 컸다. 순환흐름속도의 증가로 인해 성분오염은 약 10.20% 감소하였고, 총 오염에 대한 세공막힘의 비율은 높았다.

Treatment of oily wastewater from cold-rolling mill through coagulation and integrated membrane processes

  • Cheng, Xue-Ni;Gong, Yan-Wen
    • Environmental Engineering Research
    • /
    • 제23권2호
    • /
    • pp.159-163
    • /
    • 2018
  • The feasibility of applying coagulation-integrated microfiltration (MF) as a pretreatment for an ultrafiltration (UF) feed in oily wastewater treatment was investigated. The effects of different coagulants on oil removal rates from wastewater were studied. The maximum oil removal rate of 82% was obtained after coagulation with 130 mg/L of polyaluminium chloride (PAC). UF flux reached $95L/(m^2{\cdot}h)$ with coagulation-integrated MF as pretreatment. This value was 2.5 times higher than that flux obtained without pretreatment. The value of UF flux increased as the transmembrane pressure (TMP) and cross-flow velocity (CFV) of the UF module increased. UF flux gradually increased when TMP and CFV exceeded 0.4 MPa and 3 m/s, respectively, because of concentration polarization and membrane fouling stabilization. Chemical oxygen demand reduction and oil removal rate reached 95.2% and 98.5%, respectively, during integrated membrane processing with a PAC concentration of 130 mg/L, TMP of 0.4 MPa, and CFV of 3 m/s for UF. In addition, sequentially cleaning the fouling membrane with NaOH and $HNO_3$ aqueous solutions caused UF flux to recover to 90%. These encouraging results suggested that the hybrid integrated membrane process-based coagulation and MF + UF are effective approaches for oily wastewater treatment.

무기 콜로이드 현탁액의 십자류 정밀여과에 의한 투과유속의 감소거동 (Flux Decline Behavior in Cross-flow Microfiltration of Inorganic Colloidal Suspensions)

  • 남석태;한명진
    • 멤브레인
    • /
    • 제15권4호
    • /
    • pp.338-348
    • /
    • 2005
  • 정밀여과 모세관 막을 이용한 무기 콜로이드 현탁액의 투과유속 감소특성을 검토하였다. 무기 현탁입자의 종류에 따른 투과거동은 알루미나 현탁액의 투과유속이 벤토나이트 현탁액보다 평균 2배정도 컸으며, 운전시간 경과에 따른 투과유속의 감소도 알루미나 현탁액이 벤토나이트 현탁액에 비하여 전체적으로 서서히 감소하는 경향을 보였다. 운전 시간 10분까지의 투과유속 감소율을 나타내는 초기투과유속 감소율은 벤토나이트 현탁액이 알루미나 현탁액보다 더 컸다. 막 투과유속 감소는 케익오염과 세공막힘오염에 기인하며, 막오염 형태에 있어 벤토나이트 현탁액의 세공막힘오염이 알루미나 현탁액 보다 현저히 크게 나타났다. 운전압력 $1.0\;kg_f/cm^2$에서 총 막오염에 대한 성분오염의 비율은 알루미나 현탁액의 경우 완전세공막힘 $9.35\%$, 표준세공막힘 $6.82\%$, 케익여과 $83.832\%$이었다. 순환흐름속도의 증가로 인해 투과유속은 증가하였고, 알루미나 현탁액은 $6.5\%$, 벤토나이트 현탁액은 $13.5\%$ 증가하였다. 세공크기가 $0.34\;{\mu}m$인 막의 투과유속은 세공의 크기가 $0.24\;{\mu}m$인 막보다 컸으며, 세공크기의 증가에 따른 투과유속은 알루미나 현탁액이 1.61배, 벤토나이트 현탁액이 1.76배 증가하였다.

선박용수의 재사용에 관한 기초연구(II) -중공사모듈 UF MF 필터에 의한 선박폐수의 고도처리- (A basic study on the reuse of shipboard wastewater(II) -An advanced treatment of shipboard wastewater by Hollow fiber UF and MF filtration-)

  • 김인수;김억조;김동근;고성정;안종수
    • 해양환경안전학회지
    • /
    • 제4권1호
    • /
    • pp.49-56
    • /
    • 1998
  • The Microfiltration and Ultrafiltration were used to treat effluent of secondary municipal wastewater treatment system(Sequencing Batch Reactor). The cross-flow hollow fiber, UF 500,000(NMWC) and MF 0.65$\mu$ membrane were selected as suitable membrane. Short term and long term fouling effect were measured as a factor of flux decrease and the fouling removal effect of mixing air bubble in the penetrant was studied. The removal of anionic sulfactants before and after formation of micelle with several kinds of oil were checked. The test results show that removal of TOC was 70~80%, TN 28% and TP 16%. The decrease of flux due to fouling were 85%(UF) and 90%(MF) after running of 100hrs. The removal of anionic sulfactants were 60~70% notwithstanding micelle or not.

  • PDF

알루미나 현탁액에 의해 오염된 정밀여과막의 역세척 거동 (Back Flushing Behavior of Microfiltration Membrane Fouled by Alumna Colloidal Suspensions)

  • 남석태;한명진
    • 멤브레인
    • /
    • 제19권1호
    • /
    • pp.34-46
    • /
    • 2009
  • $Al_2O_3$ 현탁액의 폴리에틸렌 정밀여과에 있어 역세척이 막오염에 미치는 영향에 대하여 분석하였다. 현탁액의 투과저항은 역세척을 한 경우가 역세척을 하지 않은 경우보다 작았으나 투과저항 증가율은 역세척을 하지 않은 때보다도 더 컸다. 막오염 형태는 역세척을 한 경우나 하지 않은 경우 운전초기에는 케익오염이 지배적이었으며, 이어 세공막힘오염이 나타났고, 정상상태에 도달하면 투과유속은 다시 케익여과 오염에 의해 지배받는 것으로 나타났다. 한편, 세척공정에 앞선 막은 운전초기에 세공막힘오염이 케익오염에 앞서 일어났다. 총오염에 대한 케익여과 오염의 비율은 역세척에 관계없이 역세척 전에 비하여 증가하였다. 세공크기가 $0.24{\mu}m$인 막의 투과저항은 세공이 $0.34{\mu}m$인 막에 비해 더 컸으나, 막오염 형태는 세공의 크기가 $0.34{\mu}m$인 막에 비해 케익오염이 작았다. 총오염에 대한 성분오염의 비율은 역세척을 한 경우에는 세공막힘이 약 7.8%, 케익오염 약 92.2%이었고, 역세척을 하지 않은 경우에는 세공막힘은 9.6% 그리고 케익오염이 90.4%이었다.

정밀여과 모세관 막을 이용한 벤토나이트 콜로이드 현탁액의 투과유속 감소특성 (Characteristics of Flux Decline in Microfiltration Capillary Membrane of Bentonite Colloidal Suspensions)

  • 남석태;한명진
    • 멤브레인
    • /
    • 제15권1호
    • /
    • pp.52-61
    • /
    • 2005
  • 폴리에틸렌 정밀여과 모세관막을 이용한 벤토나이트 콜로이드 현탁액의 투과유속 감소특성을 검토하였다. 운전시간이 경과하면서 투과유속이 감소되는 원인은 막표면 위에서 케익층의 성장과 입자들에 의한 세공막힘 때문이었으며, 운전시간이 경과하여 정상상태에 도달하면 투과유속은 케익여과 모델에 의해 지배받는다. 운전압력이 높은 경우의 투과유속 감소는 세공막힘과 케익층이 치밀해졌기 때문이다. 운전압력이 증가함에 따라 J/J₁는 감소하였으며, 0.5 kg/sub f//㎠일 때의 45%, 2.0 kg/sub f//㎠일 때 38%로 감소하였다. 운전압력 0.5 kg/sub f//㎠에서 총 막오염에 대한 성분오염의 비율은 표준세공막힘 14.6%, 완전세공막힘 23.4% 그리고 케익여과 62.0% 이었다. 순환흐름속도의 증가로 인해 투과유속은 증가하였고, 그 효과는 운전압력이 1.0 kg/sub f//㎠일 때가 운전압력 2.0 kg/sub f//㎠ 경우보다 컸다. 세공크기가 0.34 ㎛인 막의 투과유속은 세공의 크기가 0.24 ㎛인 막보다 컸으며, 용액의 농도에 따른 투과유속은 농도가 낮은 용액이 컸다. 세공크기가 0.34 ㎛인 막의 막오염 형태는 유사하지만 농도가 200 ppm인 용액의 경우 1000 ppm인 용액에 비하여 상대적으로 미약한 세공막힘 현상을 보였다.