Purification During Crossflow Electromicrofiltration of Fermentation Broth

  • Park Young G.
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.6
    • /
    • pp.500-505
    • /
    • 2004
  • The present study was to investigate the purification of a fermentation broth by an electromicrofiltration membrane. Microfiltration runs with a crude and a centrifuged broth, with solution of particles recovered from centrifugation and with permeates from microfiltration experiments were thus compared. Microfiltration performances were governed by colloids and small particles that induced sharp initial flux declines. For these results, the evolution of the overall membrane resistance was increased by $80\%$ in comparison with the electromicrofiltration membrane. The main focus of this study was set on the enhancement of the filtrate flux by an electric field. This pressure electrofiltration leads to a drastic improvement of the filtration by $100\%$ and the filtration time was thereby reduced. Pressure electrofiltration serves as an inter­esting alternative to the cross-flow filtration and it effectively separates advantageous constitu­ents such as amino acids and biopolymers from a fermentation broth. They were equally main­tained during the microelectrofiltration, although they were significantly reduced by $45\%$ by the microfiltration without the application of an electric field. Accordingly, since the electrofiltration membrane was provided more permeability, this study experimentally demonstrates that the permeability inside a membrane can be controlled using an electric field.

Microfiltration of Chlorella sp.: Influence of material and membrane pore size

  • Ahmad, A.L.;Yasin, N.H. Mat;Derek, C.J.C.;Lim, J.K.
    • Membrane and Water Treatment
    • /
    • v.4 no.2
    • /
    • pp.143-155
    • /
    • 2013
  • Four membranes were used to separate Chlorella sp. from their culture medium in cross-flow microfiltration (MF) experiments: cellulose acetate (CA), cellulose nitrate (CN), polypropylene (PP) and polyvinylidenefluoride (PVDF). It was found that the hydrophilic CA and CN membranes with a pore size of 1.2 ${\mu}m$ exhibited the best performances among all the membranes in terms of permeation flux. The hydrophobicity of each membrane material was determined by measuring the angle between the water (liquid) and membrane (solid). Contact angle measurements showed that deionized (DI) water had almost adsorbed onto the surfaces of the CA and CN membranes, which gave $0.00^{\circ}$ contact angle values. The PP and PVDF membranes were more hydrophobic, giving contact angle values of $95.97^{\circ}$ and $126.63^{\circ}$, respectively. Although the pure water flux increased with increasing pore diameter (0.8 < 1.2 < 3.0 ${\mu}m$) in hydrophilic CA and CN membranes, the best performance in term of filtration rate for filtering a microalgae suspension was attained by membranes with a pore size of 1.2 ${\mu}m$. The fouled membrane pore sizes and pore blocking were inspected using a scanning electron microscope (SEM). MF with large pore diameters was more sensitive to fouling that contributed to intermediate blocking, where the size of the membrane pores is almost equivalent to that of cells.

Three Dimensional Simulation of the Deposition of Multi-dispersed Particles during Cross-flow Microfiltration (정밀여과에서 불균일 입자에 의한 막오염에 관한 3차원 모사 연구)

  • ;;;Fane, Antony G.
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.04b
    • /
    • pp.48-49
    • /
    • 1997
  • 막분리에 있어 막오염 현상은 공정의 경제성을 좌우하는 중요한 요소이다. 이에따라 막오염에 따른 플럭스 변화를 예측하기 위한 다양한 방법을 시도하고 있다. 그러나 대부분의 동력학적 해석식들은 여과초기에만 적용되는 단점이 있었다. 최근에는 콜로이드 입자에 의한 막오염 과정을 그대로 모사하여 여과개시 후 상당한 시간 후의 플럭스를 예측하려는 시도를 하고 있다. 그러나 지금까지 연구된 모델들은 2차원입자를 사용하거나 혹은 단일입자분포를 갖는 3차원입자를 사용한 것들이었다. 2차원 모사인 경우 세공막힘현상을 설명할 수 없으며 3차원 단일분포 입자시스템은 현실과는 거리가 먼 단점이 있었다. 이에따라 본 연구에서는 다중분포(multi-disperse)를 갖는 입자의 정밀여과 (microfiltration)를 모사하여 시간에 따른 플럭스의 변화를 예측해 보고자 하였다.

  • PDF

Fouling Behavior of Bentonite Colloidal Suspensions in Microfiltration (벤토나이트 현탁액에 의한 정밀여과 막의 오염특성)

  • Nam, Suk-Tae;Han, Myeong-Jin
    • Membrane Journal
    • /
    • v.18 no.1
    • /
    • pp.53-64
    • /
    • 2008
  • Fouling behavior of polyethylene capillary membranes was examined by measuring the flux of bentonite colloidal suspensions through the cross flow micro filtration. The membrane fouling was due to the three mechanisms: the cake formation on the membrane surface, the standard pore blocking and the complete pore blocking by particles. These mechanisms were simultaneously responsible for the membrane fouling, being significantly governed by the cake filtration. In the total fouling at $1.0kg/cm^2$ TMP condition, the complete blocking was 3.36%, the standard blocking 3.18% and the cake filtration 96.05%. For 1000 ppm feed solution, the complete blocking was 1.71% compared with the standard blocking of 1.90% and the cake filtration of 96.39%. And 96.14% of the total fouling was generated at the initial period of filtration. The cake filtration effect was larger on $0.34{\mu}m$ pore membrane than on $0.24{\mu}m$ pore membrane. With the increase in cross flow velocity, the component fouling decreased by 10.20%, and the ratio of pore blocking to total fouling increased.

Treatment of oily wastewater from cold-rolling mill through coagulation and integrated membrane processes

  • Cheng, Xue-Ni;Gong, Yan-Wen
    • Environmental Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.159-163
    • /
    • 2018
  • The feasibility of applying coagulation-integrated microfiltration (MF) as a pretreatment for an ultrafiltration (UF) feed in oily wastewater treatment was investigated. The effects of different coagulants on oil removal rates from wastewater were studied. The maximum oil removal rate of 82% was obtained after coagulation with 130 mg/L of polyaluminium chloride (PAC). UF flux reached $95L/(m^2{\cdot}h)$ with coagulation-integrated MF as pretreatment. This value was 2.5 times higher than that flux obtained without pretreatment. The value of UF flux increased as the transmembrane pressure (TMP) and cross-flow velocity (CFV) of the UF module increased. UF flux gradually increased when TMP and CFV exceeded 0.4 MPa and 3 m/s, respectively, because of concentration polarization and membrane fouling stabilization. Chemical oxygen demand reduction and oil removal rate reached 95.2% and 98.5%, respectively, during integrated membrane processing with a PAC concentration of 130 mg/L, TMP of 0.4 MPa, and CFV of 3 m/s for UF. In addition, sequentially cleaning the fouling membrane with NaOH and $HNO_3$ aqueous solutions caused UF flux to recover to 90%. These encouraging results suggested that the hybrid integrated membrane process-based coagulation and MF + UF are effective approaches for oily wastewater treatment.

Flux Decline Behavior in Cross-flow Microfiltration of Inorganic Colloidal Suspensions (무기 콜로이드 현탁액의 십자류 정밀여과에 의한 투과유속의 감소거동)

  • Nam Suk-Tae;Han Myeong-Jin
    • Membrane Journal
    • /
    • v.15 no.4
    • /
    • pp.338-348
    • /
    • 2005
  • The permeate flux decline on microfiltration capillary membrane operation was investigated with inorganic colloidal solutions. The permeate flux of the alumina solution is two times higher in average than that of the bentonite solution. The flux decline with increase in operation time was less in the alumina solution than in the bentonite solution. The rate of initial flux decline until 10 min was higher on the bentonite solution over the alumina solution. The decline in permeate flux was due to both the cake formation and the pore blocking. The latter effect was higher in the operation of the bentonite solution. In comparing the ratio of each fouling component to the total fouling fur the $1.0\;kg_f/cm^2$ TMP condition, complete blocking was $9.35\%$, standard blocking was about $6.82\%$ and cake filtration was $83.83\%$, respectively. With the increase in cross flow velocity, the permeate flux increased by $6.0\%$ for the alumina solution and by 14.0 for the bentonite solution. With the increase in average pore size fromm $0.24\;{\mu}m\;to\;0.34\;{\mu}m$, the permeate flux increases 1.61 times for the alumina solution and 1.76 times far the bentonite solution.

A basic study on the reuse of shipboard wastewater(II) -An advanced treatment of shipboard wastewater by Hollow fiber UF and MF filtration- (선박용수의 재사용에 관한 기초연구(II) -중공사모듈 UF MF 필터에 의한 선박폐수의 고도처리-)

  • 김인수;김억조;김동근;고성정;안종수
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.4 no.1
    • /
    • pp.49-56
    • /
    • 1998
  • The Microfiltration and Ultrafiltration were used to treat effluent of secondary municipal wastewater treatment system(Sequencing Batch Reactor). The cross-flow hollow fiber, UF 500,000(NMWC) and MF 0.65$\mu$ membrane were selected as suitable membrane. Short term and long term fouling effect were measured as a factor of flux decrease and the fouling removal effect of mixing air bubble in the penetrant was studied. The removal of anionic sulfactants before and after formation of micelle with several kinds of oil were checked. The test results show that removal of TOC was 70~80%, TN 28% and TP 16%. The decrease of flux due to fouling were 85%(UF) and 90%(MF) after running of 100hrs. The removal of anionic sulfactants were 60~70% notwithstanding micelle or not.

  • PDF

Back Flushing Behavior of Microfiltration Membrane Fouled by Alumna Colloidal Suspensions (알루미나 현탁액에 의해 오염된 정밀여과막의 역세척 거동)

  • Nam, Suk-Tae;Han, Myeong-Jin
    • Membrane Journal
    • /
    • v.19 no.1
    • /
    • pp.34-46
    • /
    • 2009
  • Effect of backflushing on the membrane fouling for polyethylene capillary membranes was examined by measuring the flux of $Al_2O_3$ colloidal suspensions through the cross flow microfiltration. In the comparison of with and without the application of backflushing, the hydraulic resistance to permeate flow of the suspension was less with backfluslng, but the Increasing rate in permeate resistance was higher. Regardless of backflushing, the cake filtration was dominant at the initial period of filtration with backflushing, being followed by the pore blocking. And at steady state, the fouling mechanism is almost governed by the cake filtration model. On the contrary, the pore blocking preceded the cake filtration in the initial stage of the original membrane before backflushing. And irrespective of backflushing, the ratio of cake filtration to total fouling increased, compared with that fur before backflushing. For the membrane with $0.24{\mu}m$ pore size, the permeate resistance was higher than that of $0.34{\mu}m$ pore size membrane. but the ratio of cake filtration was smaller than that of large pore membrane. In comparing the ratio of each fouling component to the total fouling for the case with backflushing pore blocking was 7.8% and cake filtration was 92.2%. for the case without backflushing, total fouling was composed of 9.6% pore blocking and 90.4% cake filtration.

Characteristics of Flux Decline in Microfiltration Capillary Membrane of Bentonite Colloidal Suspensions (정밀여과 모세관 막을 이용한 벤토나이트 콜로이드 현탁액의 투과유속 감소특성)

  • Nam Suk-Tae;Han Myeong-Jin
    • Membrane Journal
    • /
    • v.15 no.1
    • /
    • pp.52-61
    • /
    • 2005
  • Permeate flux decline in a microfiltration was analyzed by measuring the permeability of bentonite colloidal solution through polyethylene capillary membranes. The flux decline with time was due to the growth of cake layer on the membrane surface and to the pore blocking by particles. As the time approaches to steady state, the permeate flux is almost controlled by the cake filtration model. Faster flux decline at high trans-membrane pressure was attributed to the formation of denser packed cake layer and pore blocking. The ratio of permeate flux to the initial permeate flux, J/J₁, decreased with increasing the trans-membrane pressure, from 45% for 0.5 kg/sub f//㎠ to 38% for 2.0 kg/sub f//㎠. In comparing the ratio of each fouling component to the total fouling for the 0.5 kg/sub f//㎠ TMP condition, complete blocking was 23.4%, standard blocking was about 14.6% and cake filtration was 62.0%, respectively. Permeate flux through the membrane increases with cross flow velocity, and the effect of the variation of velocity is more significant at 1.0 kg/sub f//㎠ rather than at 2.0 kg/sub f//㎠ of the operation pressure. Permeate flux for the membrane having the average pore diameter of 0.34 ㎛ was higher than that for the membrane of 0.24 ㎛ pore size, with the higher flux with the low concentration of feed. On the operation using the membrane of 0.34 ㎛ pore, the pore blocking in the low concentration of 200 ppm is negligible relative to the pore blocking in the 1000 ppm feed.