• Title/Summary/Keyword: cross-coherence

Search Result 95, Processing Time 0.026 seconds

Preliminary Experiment for High-resolution Measurement of Tissue Mechanical Properties Using Dynamic Optical Coherence Elastography (동적 광단층 탄성영상법을 이용한 조직의 고해상도 기계적 성질 측정을 위한 예비 실험)

  • Kwon, Daa Young;Ahn, Yeh-Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.3
    • /
    • pp.99-103
    • /
    • 2018
  • Optical coherence elastography (OCE) is based on optical coherence tomography (OCT), which is a noninvasive, high-resolution, cross-sectional imaging technique. In this paper, we have developed dynamic optical coherence elastography to measure elasticity, a mechanical property of tissue, by phase difference. A piezoelectric actuator was used for sinusoidal mechanical loading of samples. Before applying this method to biomaterial, we assessed the feasibility of OCE with samples of sponge, eraser, and sharp lead. Cross-sectional and phase-difference images of the sample were obtained under sinusoidal loading. The strain rate was calculated from the phase-difference information. To obtain the envelope of the phase-difference oscillations along the horizontal direction, Hilbert transformation was performed at each depth. The elevation of the envelope was represented by color mapping, and we could measure the relative elasticity within the sample by comparing the elevations. Finally, there was an advantage when we calculated the shear rate using self-interference in the sample arm, instead of the interference between sample and reference arms.

The Effects of Noise/Signal Ratios on Noise/Energy Source Identification in Linear Systems (선형계에 있어서의 잡음/신호비가 소음/진동원 규명에 미치는 영향)

  • 박정석;김광준;이종원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.1819-1830
    • /
    • 1991
  • The problems associated with noise/energy source identification using multiple input/single output model in linear systems are investigated. Partial coherence function is formulated for the model introducing a virtual force and extraneous noises into the conventional two input/single output system. The analytical results show that the partial coherence function in two input/single output linear system is the function of noise/signal ratios when multiple inputs are mutually coherent and extraneous noises exist. Parametric studies for ordinary and partial coherence functions are carried out to demonstrate the effects of noise/signal ratios for these functions.

Understanding of unsteady pressure fields on prisms based on covariance and spectral proper orthogonal decompositions

  • Hoa, Le Thai;Tamura, Yukio;Matsumoto, Masaru;Shirato, Hiromichi
    • Wind and Structures
    • /
    • v.16 no.5
    • /
    • pp.517-540
    • /
    • 2013
  • This paper presents applications of proper orthogonal decomposition in both the time and frequency domains based on both cross spectral matrix and covariance matrix branches to analyze multi-variate unsteady pressure fields on prisms and to study spanwise and chordwise pressure distribution. Furthermore, modification of proper orthogonal decomposition is applied to a rectangular spanwise coherence matrix in order to investigate the spanwise correlation and coherence of the unsteady pressure fields. The unsteady pressure fields have been directly measured in wind tunnel tests on some typical prisms with slenderness ratios B/D=1, B/D=1 with a splitter plate in the wake, and B/D=5. Significance and contribution of the first covariance mode associated with the first principal coordinates as well as those of the first spectral eigenvalue and associated spectral mode are clarified by synthesis of the unsteady pressure fields and identification of intrinsic events inside the unsteady pressure fields. Spanwise coherence of the unsteady pressure fields has been mapped the first time ever for better understanding of their intrinsic characteristics.

A Study on Optical Coherence Tomography System by Using the Optical Fiber (광섬유를 이용한 광영상단층촬영기 제작에 관한 연구)

  • 양승국;박양하;장원석;오상기;이석정;김기문
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.34-40
    • /
    • 2004
  • In this paper, we have studied the OCT(Optical Coherence Tomography) system which has been advantages of high resolution, 2-D cross-sectional images, low cost and small size configuration. The characteristics of light source determine the resolution and coherence length. The light source has a commercial SLD with a central wavelength of 1,285 ill11, 35.3 nm(FWHM). The optical delay line is necessary to make equal with the optical path length to scattered light or reflected light from a sample. In order to make equal the optical path length, the stage that is attached to a reference mirror is controled by a step motor. And the interferometer is configured with the Michelson interferometer by using a single mode fiber, and the scanner can be focused on the sample by using a reference ann Also, the 2-dimension cross-sectional images were measured with scanning the transverse direction of the sample by using a step motor. After detecting the internal signal of lateral direction, a scanner is moved to obtain the cross-sectional image of 2-dimension by using step motor. A photodiode, which has high detection sensitivity and excellent noise characteristics has been used. The detected small signal has a noise and interference. After filtering and amplifying the signal, the output signal is demodulated the waveform And then, a cross-sectional image is seen through converting this signal into a digitalized signal by using an AID converter. The resolution of the sample is about 30${\mu}{\textrm}{m}$, which corresponds to the theoretical resolution. Also, the cross-sectional images of onion cells were measured in real time scheme.

Acquirement of cross-sectional image by using wavelength swept laser within the two SOAs parallel configuration (병렬 SOA 구조의 파장가변 레이저를 이용한 단면 영상획득)

  • Kim, Hoon-Sup;Eom, Jin-Seob
    • Journal of Industrial Technology
    • /
    • v.28 no.B
    • /
    • pp.239-244
    • /
    • 2008
  • We have realized the swept source optical coherence tomography(SS-OCT) by using the self-fabricated wavelength swept laser(wavelength tuning range : 80nm, line-width : 0.12nm, wavelength sweeping rate : 50Hz). In addition, we have used the dual balanced detector that could make a mirror image in OCT display suppressed. We can also fabricate the comb filter of Michelson interferometer type for fast-signal processing in OCT. Using this SS-OCT system for measuring an mirror, a 1mm-depth glass and an onion, we confirmed that the in vivo epidermal cross-sectional images for them can be obtained appropriately.

  • PDF

SHIP DETECTION APPROACH BASED ON CROSSCORRELATION FROM DUAL-POLARIZATION DATA (ASAR AP 다중편파 및 MULTI-LOOK 에 의한 선박탐지 연구)

  • Yang, Chan-Su;Ouchi, Kazuo
    • Proceedings of the KSRS Conference
    • /
    • 2008.03a
    • /
    • pp.180-184
    • /
    • 2008
  • Preliminary results are reported on ship detection using coherence images computed from crosscorrelating images of multi-look-processed dual-polarization data (HH and HV) of ENVISAT ASAR. The traditional techniques of ship detection by radars such as CFAR (Constant False Alarm Rate) rely on the amplitude data, and therefore the detection tends to become difficult when the amplitudes of ships images are at similar level as the mean amplitude of surrounding sea clutter. The proposed method utilizes the property that the multi-look images of ships are correlated with each other. Because the inter-look images of sea surface are covered by uncorrelated speckle, crosscorrelation of multi-look images yields the different degrees of coherence between the images and water. The polarimetric information of ships, land and intertidal zone are first compared based on the cross-correlation between HH and HV. In the next step, we examine the technique when the dual-polarization data are split into two multi-look images.

  • PDF

Video Rate Image Signal Processing for Optical Coherence Tomography (광학 영상기를 위한 실시간 영상 신호 처리에 관한 연구)

  • 나지훈;이병하;이창수
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.3
    • /
    • pp.239-248
    • /
    • 2004
  • Optical coherence tomography(OCT) is high resolution imaging system which can see the cross section of microscopic organs in the living tissue. In this paper, we analyze the relation between the light source and the resolution of modulated signal in Michelson interferometer. We construct 1-D OCT signal processing hardware such as amplifiers, filters, and demodulate electronic signals from the photo detector. In order to get 2-D OCT image, the synchronization among optical delay line, sample stage and A/D converter is dealt with. In experiments, we verify analog and digital signal processing blocks which apply to the stacks of glasses. Finally we aquire high resolution 2-D OCT image with respect to the onion tissue. We expect that this result can be applied to the medical instrument through performance improvement.

Wavefront Folding Interferometer for 3-dimensional Coherence Imaging (3 차원 결맞음 결상을 위한 파면 접힘 간섭계)

  • Oh, Se-Baek;Hong, Young-Joo;Kwak, Yoon-Keun;Kim, Soo-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.755-759
    • /
    • 2004
  • The van Cittert-Zernike theorem has been used in radio astronomy. Recently, the van Cittert-Zernike theorem has been tried to 3D source reconstruction. A couple of interferometer has been used in 3D coherence imaging like Michelson Stellar Interferometer and Rotational Shearing Interferometer. We propose a new type of interferometer, which is a wavefront folding interferometer with a corner cube. By characteristics of the corner cube, it is capable of measuring both mutual intensity and cross spectral density function, and it is very easy to align and robust to disturbance. We simulate the feasibility of this interferometer setup by simulation of point source reconstruction.

  • PDF

Realization of Swept Source-Optical Coherence Tomography using FDML Laser (FDML 방식 스위핑 광원을 사용한 SS-OCT 구현)

  • Eom, Jin-Seob
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.46-52
    • /
    • 2011
  • In this paper, the swept source-optical coherence tomography system using frequency domain mode locked(FDML) laser has realized. The FDML swept source laser showed 55.03 kHz sweeping speed, 125 nm sweeping range, and 9 mW output optical power, which are the superiority of FDML laser compared to previous swept source lasers. Also, through the cross-sectional image captured at 5 frames per second for a mirror, a 1 mm-thickness glass plate, and a thumb bottom, the performance of the system has demonstrated.

Factors Related to Self-perception of Diet Quality among South Korean Adults

  • Kye, Su-Yeon;Yun, E-Hwa;Park, Kee-Ho
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.4
    • /
    • pp.1495-1504
    • /
    • 2012
  • Objective: Improvements in diet can decrease the cancer rates. The aim of the present study was to determine the relationships between self-perception of diet quality and personality, impulsiveness, stress, coping strategy, sense of coherence, self-efficacy, and social support. Methods: This cross-sectional study was conducted using a multiple-stratified random sampling method based on the Korea Census of 2007. In October 2009, investigators conducted 15-minute face-to-face interviews with 1,530 South Korean volunteers who ranged from 30 to 69 years of age without a history of cancer. Results: Respondents were more likely to perceive that they consumed a healthy diet if they were older than 50 years, lived with a partner, had a monthly family income greater than $4,000 USD, had a low perceived risk of cancer, consumed less alcohol, exercised regularly, had a less agreeable or conscientious personality, had low stress levels, had a high sense of coherence or self-efficacy, and had ample social support. Conclusion: Psychosocial factors, such as personality, stress, sense of coherence, self-efficacy, and social support, are associated with the self-perception of diet quality. Analysis of the factors that contribute to a perceived healthy diet could assist with the design of educational campaigns.