• 제목/요약/키워드: critical initial energy

검색결과 104건 처리시간 0.029초

비대칭 초기 조건을 갖는 얕은 아치의 동적 불안정과 순시 주파수 변화 (Dynamic Instability and Instantaneous Frequency of a Shallow Arch With Asymmetric Initial Conditions)

  • 손수덕;하준홍
    • 한국공간구조학회논문집
    • /
    • 제20권2호
    • /
    • pp.77-85
    • /
    • 2020
  • This paper examined the dynamic instability of a shallow arch according to the response characteristics when nearing critical loads. The frequency changing feathers of the time-domain increasing the loads are analyzed using Fast Fourier Transformation (FFT), while the response signal around the critical loads are analyzed using Hilbert-Huang Transformation (HHT). This study reveals that the models with an arch shape of h = 3 or higher exhibit buckling, which is very sensitive to the asymmetric initial conditions. Also, the critical buckling load increases as the shape increases, with its feather varying depending on the asymmetric initial conditions. Decomposition results show the decrease in predominant frequency before the threshold as the load increases, and the predominant period doubles at the critical level. In the vicinity of the critical level, sections rapidly manifest the displacement increase, with the changes in Instantaneous Frequency (IF) and Instant Energy (IE) becoming apparent.

Transient Critical Heat Flux Under Flow Coastdown in a Vertical Annulus With Non-Uniform Heat Flux Distribution

  • Moon, Sang-Ki;Chun, Se-Young;Park, Ki-Yong;Baek, Won-Pil
    • Nuclear Engineering and Technology
    • /
    • 제34권4호
    • /
    • pp.382-395
    • /
    • 2002
  • An experimental study on transient critical heat flux (CHF) under flow coastdown has been performed for the water flow in a non-uniformly heated vertical annulus under low flow and a wide range of pressure conditions. The objectives of this study are to systematically investigate the effect of the flow transient on the CHF and to compare the transient CHF with steady-state CHF The transient CHF experiments have been performed for three kinds of flow transient modes based on the coastdown data of a nuclear power plant reactor coolant pump. At the same inlet subcooling, system pressure and heat flux, the effect of the initial mass flux on the critical mass flux can be negligible. However, the effect of the initial mass flux on the time-to- CHF becomes large as the heat flux decreases. The critical mass flux has the largest value for slow flow reduction rate. There is a pressure effect on the ratio of the transient CHF data to steady-state CHF data. Except under low system pressure conditions, the flow transient CHF was revealed to be conservative compared with the steady-state CHF data. Bowling CHF correlation and thermal hydraulic system code MARS show promising results for the prediction of CHF occurrence .

GLOBAL SOLUTIONS FOR A CLASS OF NONLINEAR SIXTH-ORDER WAVE EQUATION

  • Wang, Ying
    • 대한수학회보
    • /
    • 제55권4호
    • /
    • pp.1161-1178
    • /
    • 2018
  • In this paper, we consider the Cauchy problem for a class of nonlinear sixth-order wave equation. The global existence and the finite time blow-up for the problem are proved by the potential well method at both low and critical initial energy levels. Furthermore, we present some sufficient conditions on initial data such that the weak solution exists globally at supercritical initial energy level by introducing a new stable set.

RELATION BETWEEN VIRIAL ENERGY AND MAGNETIC ENERGY PROVIDED BY AN EMERGING FLUX TUBE ON THE SUN

  • 강지혜;;안준모;이환희
    • 천문학회보
    • /
    • 제37권1호
    • /
    • pp.86.1-86.1
    • /
    • 2012
  • The MHD virial theorem applied for observed photospheric field may be the one of way to estimate magnetic energy of generally invisible coronal magnetic structure. However, the photospheric field is not in a force-free state, so the application of virial theory needs some care. Here we use a series of MHD simulations of emerging field to investigate how we can apply the virial theorem to the emerging field. In early emerging phase, virial energy has a minus value although positive area at the photosphere is continuously generated toward a late emerging phase. We discuss why this tendency occurs. Then we derive the critical height where the actual emerging magnetic energy is almost comparable to the virial energy. If the difference between virial energy and magnetic energy becomes 10 percentage of the magnetic energy, we define this is the critical height, and assume the emerging field is close to force-free. We also discuss how the critical height changes with the initial twist of an emerging flux tube.

  • PDF

RELAP5 / MOD3/ KAERI의 임계유동모델을 위한 실제적 배출계수의 정량화 (Quantification of Realistic Discharge Coefficients for the Critical Flow Model of RELAP5/MOD3/KAERl)

  • 권태순;정법동;이원재;이남호;허재영
    • Nuclear Engineering and Technology
    • /
    • 제27권5호
    • /
    • pp.701-709
    • /
    • 1995
  • RELAP5 /MOD3/KAERl의 임계유동모델을 위한 실제적인 배출계수들을 9개의 MARVIKEN 임계유동실험 의 평가계산을 통하여 과냉각과 이상임계유동에 대하여 구하였다. 선택된 실험에는 높은 초기 과냉각도와 큰 노즐 세 장비(L/D)인 것들이 포함되었다. 코드의 평가결과는 RELAP5/MOD3/KAERI은 과냉각임계유동을 크게 예측하고 이 상임계유동은 작게 예측함을 보이고 있다. 이러한 결과들을 이용하여 임계유동모델의 실제적인 배출계수들을 반복법으로 정량화 하였다. 실제적인 배출계 수는 과냉각임계유동이 0.89 그리고 이상임계유동이 1.07로 결정되었으며 관련 표준편차는 각 각 0.0349과 0.1189이다. 본 연구로부터 얻어진 결과는 대형냉각재 상실사고의 실제적인 계통반응 계산과 비상노심냉각계통 성능평가에 적용할 수 있다.

  • PDF

An Empirical Correlation for Subcooled Two-Phase Critical Flow Rates in Short Tubes, Nozzles, and Orifices

  • Park, Choon-Kyung;Seok Cho;Won, Soon-Yeun;Min, Kyung-Ho;Chung, Moon-Ki
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.273-278
    • /
    • 1997
  • Critical two-phase flow rates of subcooled water through very short tube (L=20 mm) with small diameters (D=1.0 mm) has been measured for wide ranges of subcooling(0~186$^{\circ}C$) and pressure (0.5~2.0 MPa). Experimental results show that subcooled critical two-phase flow rates can be expressed in terms of two scaling parameters for geometries and initial conditions. They are discharge coefficient of cold water, ( $C_{d}$ )$_{ref}$, and dimensionless subcooling, $\Delta$ $T^{*}$$_{sub}$, respectively. A new empirical correlation expressed in terms of ( $C_{d}$ )$_{ref}$ and $\Delta$ $T^{*}$$_{sub}$ is obtained for subcooled two-phase flow rates through very short length tube. Comparisons between the mass fluxes calculated by Present correlation and a number of experimental data show that the agreement is very good.ood.ood.ood.

  • PDF

공기/연료분무 혼합기의 점화 및 화염전파 해석 (Numerical Analysis of Ignition and Flame Propagation in the Air/Fuel Spray Mixture)

  • 김용모;김성준
    • 대한기계학회논문집
    • /
    • 제19권12호
    • /
    • pp.3352-3359
    • /
    • 1995
  • An Eulerian-Lagrangian method is employed to simulate the ignition process and the flame propagation through the air/fuel spray mixture in a closed constant-volume combustor. The spray mixture is ignited by providing a hot wall at the end of the combustor or by firing the electric spark. The investigated parameters involve the initial droplet size, overall equivalence ratio, initial fuel vapor concentration, distance between the hot wall and the nearest droplet, and the ignition energy. Numerical results clearly show the existence of the optimum spray condition for minimizing the ignition energy and the ignition delay time as well as the critical dependence of ignition upon the distance of the heat source to the nearest droplet.

An algorithm for evaluating time-related human reliability using instrumentation cues and procedure cues

  • Kim, Yochan;Kim, Jaewhan;Park, Jinkyun;Choi, Sun Yeong;Kim, Seunghwan;Jung, Wondea;Kim, Hee Eun;Shin, Seung Ki
    • Nuclear Engineering and Technology
    • /
    • 제53권2호
    • /
    • pp.368-375
    • /
    • 2021
  • The performance time of human operators has been recognized as a key aspect of human reliability in socio-complex systems, including nuclear industries. Because of the importance of the time factor, most existing human reliability assessment methods provide ways to quantify human error probabilities (HEPs) that are associated with the performance time. To quantify such kinds of HEPs, it is crucial to rationally predict the length of time required and time available and compare them. However, there have not been detailed guidelines that identify the critical cue presentation time or initial time of human performance, which is important to calculate the time information. In this paper, we introduce a time-related HEP calculation technique with a decision algorithm that determines the critical cue and its timing. The calculation process is presented with the application examples. It is expected that the proposed algorithm will reduce the variability in the time-related reliability assessment and strengthen the scientific evidence of the assessment process. The detailed description is provided in the technical report KAERI/TR-7607/2019.

Critical earthquake input energy to connected building structures using impulse input

  • Fukumoto, Yoshiyuki;Takewaki, Izuru
    • Earthquakes and Structures
    • /
    • 제9권6호
    • /
    • pp.1133-1152
    • /
    • 2015
  • A frequency-domain method is developed for evaluating the earthquake input energy to two building structures connected by viscous dampers. It is shown that the earthquake input energies to respective building structures and viscous connecting dampers can be defined as works done by the boundary forces between the subsystems on their corresponding displacements. It is demonstrated that the proposed energy transfer function is very useful for clear understanding of dependence of energy consumption ratios in respective buildings and connecting viscous dampers on their properties. It can be shown that the area of the energy transfer function for the total system is constant regardless of natural period and damping ratio because the constant Fourier amplitude of the input acceleration, relating directly the area of the energy transfer function to the input energy, indicates the Dirac delta function and only an initial velocity (kinetic energy) is given in this case. Owing to the constant area property of the energy transfer functions, the total input energy to the overall system including both buildings and connecting viscous dampers is approximately constant regardless of the quantity of connecting viscous dampers. This property leads to an advantageous feature that, if the energy consumption in the connecting viscous dampers increases, the input energies to the buildings can be reduced drastically. For the worst case analysis, critical excitation problems with respect to the impulse interval for double impulse (simplification of pulse-type impulsive ground motion) and multiple impulses (simplification of long-duration ground motion) are considered and their solutions are provided.

Wetting Properties of Biopolyester Films Prepared by Thermo-Compression Method

  • Rhim, Jong-Whan;Hong, Seok-In
    • Food Science and Biotechnology
    • /
    • 제16권2호
    • /
    • pp.234-237
    • /
    • 2007
  • Water resistance of three biopolyester films, such as poly-L-lactate (PLA), poly-hydroxybutyrate-co-valerate (PHBV), and Ecoflex, and low density polyethylene (LDPE) film was investigated by measuring contact angle of various probe liquids on the films. The properties measured were initial contact angle of water, dynamic change of the water contact angle with time, and the critical surface energy of the films. Water contact angle of the biopolyester films ($57.62-68.76^{\circ}$) was lower than that of LDPE film ($85.19^{\circ}$) indicating biopolyester films are less hydrophobic. The result of dynamic change of water contact angle also showed that the biopolyester films are less water resistant than LDPE film, but much more water resistant than cellulose-based packaging materials. Apparent critical surface energy for the biopolyester films (35.15-38.55 mN/m) was higher than that of LDPE film (28.59 mN/m) indicating LDPE film is more hydrophobic.