• Title/Summary/Keyword: critical discharge

Search Result 295, Processing Time 0.034 seconds

Carbon Nano-Powder Functionalization and Disperisibility with Plasma Discharge

  • Gang, Yu-Seok;Jeong, Man-Gi;Lee, Deok-Yeon;Song, Seok-Gyun;Kim, Seong-In
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.491-491
    • /
    • 2013
  • A novel plasma system has been developed for 3-dimensional modification of the carbon nano-powders. Improvement of dispersion of these nano materials are studied by plasma discharge, not using chemical modification. The plasma process is considered to great advantages over wet chemical process due to environmental, economic viewpoint, and uniformity over the treated volume. The uniform dispersion is a critical factor for these material's nano composite applications. Using this plasma system, graphene, carbon black, and CNT was treated and functionalized. Several key discharge conditions such as Ar/H2/O2 or Ar/H2/NH3 gas ratio, treatment time, power, feeder's vibration frequency are investigated. Hydrophobic of graphene has turned some more into hydrophilic by reaction test with water, electrophoresis, surface contact angle test, and turbidity analysis. The oxygen content ratio in the plasma treated CNT has increased about 3.7 times than the untreatedone. In the case of graphene and carbon black, the oxygen- and nitrogen- content has been enhanced average 10%. O-H (N-H) peak, C-O (C-N) peak, and C=O (C=N) peak data have been detected by FTIR measurement and intensified compared to before-plasma treatment due to O2 or NH3 content.

  • PDF

Effect of Zinc Based Anodes on Self-Discharge Behavior for Zinc-Air Batteries (아연-공기 전지용 음극재의 자가방전 억제 효과)

  • Jung, Min Seo;Jo, Yong Nam
    • Korean Journal of Materials Research
    • /
    • v.30 no.12
    • /
    • pp.709-714
    • /
    • 2020
  • For zinc-air batteries, there are several limitations associated with zinc anodes. The self-discharge behavior of zinc-air batteries is a critical issue that is induced by corrosion reaction and hydrogen evolution reaction (HER) of zinc anodes. Aluminum and indium are effective additives for controlling the hydrogen evolution reaction as well as the corrosion reaction. To enhance the electrochemical performances of zinc-air batteries, mechanically alloyed Zn-Al and Zn-In materials with different compositions are successfully fabricated at 500rpm and 5h milling time. Investigated materials are characterized by X-ray diffractometer (XRD), field emission scanning electron microscope (FE-SEM), and energy dispersive spectrometer (EDS). Alloys are investigated for the application as novel anodes in zinc-air batteries. Especially, the material with 3 wt% of indium (ZI3) delivers 445.37 mAh/g and 408.52 mAh/g of specific discharge capacity with 1 h and 6 h storage, respectively. Also, it shows 91.72 % capacity retention and has the lowest value of corrosion current density among attempted materials.

A Study on the Permeation Properties of Permanent Gases and condensable Vapors through Hexamethyldisiloxane Plasma-Polymerized Membranes (Hexamethyldisiloxane 플라즈마 중합막을 통한 영구기체 및 응축성 증기의 투과특성에 관한 연구)

  • Oh, Sae-Joong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.699-706
    • /
    • 2018
  • The permeation properties of plasma polymer membranes were studied for permanent gases such as He, $H_2$, $O_2$, $N_2$, $CH_4$ and condensable vapors such as $CO_2$, $C_2H_4$, $C_3H_8$. The plasma polymers were prepared by the discharge of microwave or radiofrequency(RF) wave. Hexamethyldisiloxane (HMDS) vapor was used as a monomer for plasma polymerization. In HMDS plasma-polymerized membranes prepared under microwave discharge, the permeability coefficient was dependent of the kinetic molecular diameter of the permeate gases. Additionally the membranes showed higher $O_2/N_2$ permselectivity compared to the plasma polymers from radiofrequency discharge. On the contrary, in the HMDS plasma-polymerized membranes prepared under radiofrequency discharge, the permeability coefficient was dependent of the critical temperature of the permeant gases. The membranes showed high selectivities of $C_2H_4$ and $C_3H_8$ over $N_2$. The permeability coefficient of plasma polymerized membranes prepared under microwave discharge was dependent of the molecular diameter of permeant gases because of high crosslinking density of the membrane. However, the crosslinking density of the plasma polymerized membranes prepared under RF discharge was lower because the energy density of RF wave is weaker than that of microwave. Hence, the permeability of RF plasma polymerized membranes became dependent of the critical temperature rather than molecular diameter of the gases.

The Effect of Similarity Condition for the Test Results in a Wind Tunnel Test (풍동실험에서 상사조건이 실험결과에 미치는 영향에 관한 연구)

  • 봉춘근
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.4
    • /
    • pp.351-362
    • /
    • 2000
  • To set the similarity conditions between a prototype usually in the field and its reduced-scale model is a crucial part in model tests. No technique is available to keep perfect similarity for this procedure so far. The experimental work using a wind tunnel is not exceptional. based on the field measurements, the effect of stack parameters and wind conditions on the dispersion of stack plume has been investigated in the laboratory. in this paper intensive methodology is focused on matching these similarities. Due to the limitations to keep perfect similarity conditions some simplifications are involved in common. In this study geometric conditions and kinematic conditions using Froude number and Reynolds number have been con-sidered to keep the similarity conditions required. From the tests it is found that the critical Reynolds number (Recrit) is 2,700 when the height of stack discharge is 50mm. The dispersion has a similar trend for the higher Reynolds number than the critical Reynolds number. It is also found that different Froude number does not make any significant influence for the normalized tracer gas concentrations at the recipient providing the same ratio of the wind speed to the discharge speed. No significant effect of stack diameter is observed in the normalized tracer gas concentrations with the same Frounde number. The similarity conditions therefore used in this study are reliable to simulate the conditions in prototype into the wind tunnel tests.

  • PDF

Risk Factors for Cognitive Impairment in Intensive Care Unit Survivors (중환자실 퇴원환자의 인지장애 위험요인)

  • Kang, Ji Yeon;Yi, Bo Kyung
    • Journal of Korean Critical Care Nursing
    • /
    • v.13 no.3
    • /
    • pp.75-85
    • /
    • 2020
  • Purpose : This study aimed to identify the prevalence and risk factors of cognitive impairment in survivors discharged from the intensive care unit (ICU). Methods : This secondary analysis study utilized data from a multicenter prospective cohort of post-ICU patients. We analyzed the data of 175 patients enrolled in the primary cohort who completed the cognitive function evaluation three months after ICU discharge. Cognitive function was assessed using the Montreal Cognitive Assessment (MoCA) scale. The cut-off points for cognitive impairment were < 23 for face-to-face evaluation and < 18 for telephone evaluation. Results : The prevalence of cognitive impairment three months after ICU discharge was 32.6%. Significant risk factors for cognitive impairment were age ≥ 60 years (OR=10.52, 95% CI=3.65~30.33, p<.001), education < high school graduation (OR=2.53, 95% CI=1.07~6.01, p=.035), unplanned ICU admission (OR=4.01, 95% CI=1.45-11.14, p=.008), and delirium in the ICU (OR=4.33, 95% CI=1.08-17.23, p=.038). Conclusion : ICU nurses should use preemptive strategies to reduce post-ICU cognitive impairment of patients with risk factors. It is necessary to frequently assess and detect early delirium in critically ill patients, while attempting various non-pharmacological interventions.

High Current Behavior and Double Snapback Mechanism Analysis of Gate Grounded Extended Drain NMOS Device for ESD Protection Device Application of DDIC Chip (DDIC 칩의 정전기 보호 소자로 적용되는 GG_EDNMOS 소자의 고전류 특성 및 더블 스냅백 메커니즘 분석)

  • Yang, Jun-Won;Kim, Hyung-Ho;Seo, Yong-Jin
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.2
    • /
    • pp.36-43
    • /
    • 2013
  • In this study, the high current behaviors and double snapback mechanism of gate grounded_extended drain n-type MOSFET(GG_EDNMOS) device were analyzed in order to realize the robust electrostatic discharge(ESD) protection performances of high voltage operating display driver IC(DDIC) chips. Both the transmission line pulse(TLP) data and the thermal incorporated 2-dimensional simulation analysis as a function of ion implant conditions demonstrate a characteristic double snapback phenomenon after triggering of bipolar junction transistor(BJT) operation. Also, the background carrier density is proven to be a critical factor to affect the high current behavior of the GG_EDNMOS devices.

Development of Hardware for Controlling Abnormal Temperature in PCS of Photovoltaic System (태양광발전시스템의 PCS에서 이상 온도 제어를 위한 하드웨어개발)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Kim, Yoon-Bok
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.1
    • /
    • pp.21-26
    • /
    • 2019
  • This paper is purposed to develop hardware for controlling abnormal temperature that can occur environment and component itself in PCS. In order to be purpose, the hardware which is four part(sensing, PLC, monitoring and output) keep detecting temperature for critical components of PCS and can control the abnormal temperature. Apply to the hardware, it is selected to PV power generation facilities of 20 kW in Cheong-ju city and measured the data for one year in 2017. Through the temperature data, it is found critical components of four(discharge resistance, DC capacitor, IGBT, DSP board) and entered the setting value for operating the fan. The setting values for operating the fan are up to $130^{\circ}C$ in discharge resistance, $60^{\circ}C$ in DC capacitor, $55^{\circ}C$ in IGBT and DSP board. The hardware is installed at the same PCS(20 kW in Cheong-ju city) in 2018 and the power generation output is analyzed for the five days with the highest atmospheric temperature(Clear day) in July and August in 2017 and 2018 years. Therefore, the power generation output of the PV system with hardware increased up to 4 kWh.

Development of a Critical Pathway of Bullectomy for Spontaneous Pneumothorax Patients (자연기흉으로 폐기포절제술을 받은 환자를 위한 표준진료지침서 개발)

  • Kim, Mi Kyoung;Yu, Seung Hum;Lee, Doo Yun;Son, Young Mo
    • Quality Improvement in Health Care
    • /
    • v.9 no.1
    • /
    • pp.34-51
    • /
    • 2002
  • Background : The purpose for this study is to develop a critical pathway of bullectomy for spontaneous pneumothorax patients. Methods : For this study a conceptual framework of critical pathway was developed through a review of the literature including five critical pathways which are currently being used in USA, and opinions of the critical pathway development team members at Y university hospital. In order to identify the service contents required by these patients and to draw up a preliminary critical pathway, 33 cases of medical records of patients who had received bullectomy for spontaneous pneumothorax between September, 2000 to August, 2001 at the Respiratory Center of Y university hospital in Seoul was analyzed. Results : In order to test the clinical validity of the preliminary critical pathway, it was applied to ten patients who had received bullectomy for spontaneous pneumothorax from October, 2001 to December, 2001. The average discharge day was 4.89th post operation day, six patients discharged on the fourth post operation day which was the expected day, one patients discharged one day earlier than the expected day, one patient discharged three days later than the expected day, and one patient discharged six days later than the expected day. There were variances between the critical pathway and the actual practice. The variances came from tests, medications, and treatments. One item that showed variance in clinical applications was complemented, and three items were decided not to be corrected for the final determination of the critical pathway. Conclusion : This critical pathway is applicable to the care of patients with bullectomy for spontaneous pneumothorax, but it needs more clinical applications to grasp varied variances.

  • PDF

Critical Pathway of Home Healthcare for COPD clients (COPD 대상자의 가정간호를 위한 Critical pathway)

  • Cho, Won-Jung;Han, Mi-Kyung
    • Research in Community and Public Health Nursing
    • /
    • v.12 no.2
    • /
    • pp.329-337
    • /
    • 2001
  • Purpose: This study was to develop a critical pathway for COPD clients in home health care. Method: Review of literature. Analysis of 10 cases of home health records of COPD clients without other major chronic illness, and Contents validity test Results 1. Vertical axis(l4 activities) physical and mental assessment, family assessment. environment assessment, rights and duties of client, oxygen use and safety, education of disease process and symptom, medication, nutrition and elimination, tests, activities, respiratory exercise, sleeping pattern. consultations and discharge planning. 2. Horizontal axis was set by the number of visits(average number of visits is 6.4) and vertical axis was set with 14 activities and the contents which should have occurred, according to the time frames of the horizontal axis. 3. According to the contents validity test, among the total of 234 items, 176 items showed over 83% agreement and 58 items showed less than 83% agreement. Those items with less than 83% agreements were either deleted or revised. Conclusion this critical pathway is applicable to the home health care of COPD clients to provide quality home nursing care services at lower cost.

  • PDF

The development of the critical pathway for hysterectomy patients and its effect (자궁절제술 환자의 표준진료지침(Critical pathway) 개발과 적용효과)

  • Kim, Kyung-Hee;Seo, Young-Seung;Tae, Young-Sook;Lee, Hwa-Ja;Jeon, Sung-Sook
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.6 no.1
    • /
    • pp.123-134
    • /
    • 2000
  • This study intended to analyze the effectiveness to obtain by developing the critical pathway presented as the method to improve the quality-betterment and cost effectiveness the through the continuous and consistent patient management for the hysterectomy patient and applying it to the real practice. This study was designed to develop and effect the critical pathway for hysterectomy patients in the way to be possible the intergrated in patient management. It was adopted the process of seven phase to develop a critical pathway. To analyze the application effect of the developed critical pathway, this author offered health care service applying the critical pathway to the hysterectomy patient from July. 20 to Oct. 19. 1999. The study method had been done by investigating the experimental group and control group through the questionnaire on 40 patients who had been inpatient hysterectomy. Dependent variables were measured by modified from satisfaction, and cost and length of hospital stay. The data anlyzed by frequency, x2-test, t-test. The results of this study was as follows; 1. It was decided that the vertical line of the critical pathway was made up of eight items such as monitoring/assessment, treatment, activity, medication, consult. Lab test, diet, patient teaching and horizontal line was 7days from admission to discharge. 2. After the verifying the validity of the expert group about the critical pathway, the horizontal line was amended from hospitalization to five postoperative days and taking their consensus, some contents of the horizontal line was amended and deleted. 3. There was no significant differences in the experimental group and control group in the satisfaction, and significant differences in the cost, the length of hospital stay.

  • PDF