• 제목/요약/키워드: cover plate

검색결과 190건 처리시간 0.027초

강재 맨홀뚜껑의 보강구조 해석 (Analysis of Strengthening Structures of Steel Manhole Cover)

  • 김흥규;양영수;배강열
    • Journal of Welding and Joining
    • /
    • 제32권2호
    • /
    • pp.54-62
    • /
    • 2014
  • Manhole cover, which is usually made of grey cast iron and consists of frame and cover, should have enough strength to support the heavy traffic load. The manhole cover made of cast iron has heavy weight to handle manually and is vulnerable to impact force with its brittle characteristics. Moreover, its production process of casting has been regulated in terms of environmental pollution. In this study, steel manhole cover is proposed to substitute the cast cover with a series of structural analyses to confirm its strength to support the test load for manhole cover. The cover of the proposed steel manhole cover is made of thin circular pate and stiffeners below the plate. Rectangular columns and hollow circular plate were selected for the shape of the stiffener. In order to give enough strength for the cover to behave within elastic range in the loading, strengthening structures of the cover were varied with increasing the number and the size of the stiffeners. The results of the analyses revealed that when both the hollow circular stiffener and cross stiffeners were additionally applied at the same time to the steel cover with longitudinal stiffeners, the maximum stress level in the cover could be reduced to that level presented in the cast cover.

토피고 변화에 따른 Liner Plate 거동특성에 관한 연구 (A study on behavior characteristics of liner plate with depth)

  • 정지수;지영환;조현;허인영;이승호
    • 한국터널지하공간학회 논문집
    • /
    • 제14권2호
    • /
    • pp.131-139
    • /
    • 2012
  • 본 연구에서는 도심지 소구경 터널굴착공법에서 파형강판으로 제작된 liner plate의 거동특성에 대해 알아보기 위해 유한요소 해석 프로그램인 MIDAS/GTS를 이용하여 수치해석을 실시하였다. 토피고 변화에 따라 liner plate의 거동특성을 알아보기 위해 토피고는 5 m, 10 m, 15 m, 20 m, 25 m 5가지 각 조건으로 해석을 실시하였다. 수치해석결과 liner plate의 최대변위와 최대축응력은 부재의 하단부에서 발생되며, 최대전단응력의 경우 부재의 천단부에서 발생되는 것으로 확인되었다. 또한 토피고에 따른 liner plate의 변위, 응력, 전단응력의 변화는 있었으나 그 차이가 미미하고 토피고가 증가함에 따라 점점 구조적 안정성이 확보되는 것으로 판단된다.

Numerical study on effect of integrity reinforcement on punching shear of flat plate

  • Ahsan, Raquib;Zahura, Fatema T.
    • Computers and Concrete
    • /
    • 제20권6호
    • /
    • pp.731-738
    • /
    • 2017
  • Reinforced concrete flat plates consist of slabs supported directly on columns. The absence of beams makes these systems attractive due to advantages such as economical formwork, shorter construction time, less total building height with more clear space and architectural flexibility. Punching shear failure is usually the governing failure mode of flat plate structures. Punching failure is brittle in nature which induces more vulnerability to this type of structure. To analyze the flat plate behavior under punching shear, twelve finite element models of flat plate on a column with different parameters have been developed and verified with experimental results. The maximum range of variation of punching stress, obtained numerically, is within 10% of the experimental results. Additional finite element models have been developed to analyze the influence of integrity reinforcement, clear cover and column reinforcement. Variation of clear cover influences the punching capacity of flat plate. Proposed finite element model can be a substitute to mechanical model to understand the influence of clear cover. Variation of slab thickness along with column reinforcement has noteworthy impact on punching capacity. From the study it has been noted that integrity reinforcement can increase the punching capacity as much as 19 percent in terms of force and 101 percent in terms of deformation.

보강덮판으로 인한 균열진전지연 효과에 관한 연구 (A Study on the Effect of Crack Retardation due to Cover Plate)

  • 김상철;박문호;한문식
    • 대한조선학회지
    • /
    • 제25권3호
    • /
    • pp.26-34
    • /
    • 1988
  • A study of the fatigue fracture accompanied with crack propagation should be investigated systematically by the behavior of the crack propagation. In this study, the effect of crack retardation due to cover plate is investigated by analytical and experimental method. Through the analytical and experimental works, it is confirmed that the retardation of fatigue crack propagation is properly controlled by cove plate and the retardation effects may be estimated exactly by the compliance method.

  • PDF

Pre-stress를 도입한 Steel Beam에 관한 실험적 연구 (Experimental Study on Pre-Stresses Steel Beam)

  • 조진구;박병기
    • 한국농공학회지
    • /
    • 제17권4호
    • /
    • pp.3921-3930
    • /
    • 1975
  • This research was carried out to investigate several mechanical characteristics of pre-stressed steel beams. The configuration of specimens used for this study were as follows; a cover plate having permissible fiber stress of 4,000 kg/$\textrm{cm}^2$ was welded at bottom having the allowable bending stress 2500 kg/$\textrm{cm}^2$ steel beam, the section ratios of pre-stressed steel beam and cover plate were 0.5 and 0.6. Adopted pre-stresses were 0%, 50%, and 100% of an allowable fiber stress of a steel beam. The results obtained from the study may be summarized as follows; 1. The elastic range of a beam was increased by the application of pre-stress to the beam, which leads to a lighter section. 2. The permissible moment capacity of a pre-stressed steel beam was greated than that of a steel beam without pre-stressing. 3. The equivalent allowable stress induced by adopting the different section ratio of pre-stressed beam to cover plate were figured out 4. The optimum value of section ratio of beam and cover plate was 0.3 to 0.4 in case of a 1.5m span composite beam, a combination of an allowable stress 2,500kg/$\textrm{cm}^2$ steel beam and a permissible fiber stress 4,000 kg/$\textrm{cm}^2$ steel cover plate, was used. 5. The magnitude of the pre-stress was desirable to be same as the allowable stress of a steel beam. 6. It was concluded that if the construction techniques in the field are developed and improved, the practicing of pre-stress to the steel structure has a promising future.

  • PDF

Study on the progressive collapse resistance of CP-FBSP connections in L-CFST frame structure

  • Xiong, Qingqing;Wu, Wenbo;Zhang, Wang;Chen, Zhihua;Liu, Hongbo;Su, Tiancheng
    • Steel and Composite Structures
    • /
    • 제44권3호
    • /
    • pp.437-450
    • /
    • 2022
  • When the vertical load-bearing members in high-rise structures fail locally, the beam-column joints play an important role in the redistribution of the internal forces. In this paper, a static laboratory test of three full-scale flush flange beam-reinforced connections with side and cover plates (CP-FBSP connection) with double half-span steel beams and single L-shaped columns composed of concrete-filled steel tubes (L-CFST columns) was conducted. The influence of the side plate width and cover plate thickness on the progressive collapse resistance of the substructure was thoroughly analyzed. The failure mode, vertical force-displacement curves, strain variation, reaction force of the pin support and development of internal force in the section with the assumed plastic hinge were discussed. Then, through the verified finite element model, the corresponding analyses of the thickness and length of the side plates, the connecting length between the steel beam flange and cover plate, and the vertical-force eccentricity were carried out. The results show that the failure of all the specimens occurred through the cracking of the beam flange or the cover plate, and the beam chord rotations measured by the test were all greater than 0.085 rad. Increasing the length, thickness and width of the side plates slightly reduced the progressive collapse resistance of the substructures. The vertical-force eccentricity along the beam length reduced the progressive collapse resistance of the substructure. An increase in the connecting length between the beam flange and cover plate can significantly improve the progressive collapse resistance of substructures.

플레이트거더 용접구조상세의 피로거동에 관한 연구 (A Study on the Fatigue Behavior of the Welded Structural Details in Plate Girder)

  • 이명구;이승용
    • 한국안전학회지
    • /
    • 제23권2호
    • /
    • pp.14-20
    • /
    • 2008
  • The objective of this study is to examine fatigue strength of the welded details. In order to attain the goal of this study, the bending fatigue tests was performed for four kinds of welded details used in steel bridges, such as in-plane gusset, out-of-plane gusset, cruciform, and cover plate. The effect of the length of welded attachment on fatigue strength was greater in out-of-plane gusset than in in-plane gusset. The fatigue strength of welded details with short attachment was superior to that with long attachment. Fatigue strength of welded details with transversely loaded welds was lower than that with longitudinally loaded welds, and those results were not satisfied with AASHTO specifications. For the fatigue strength of cover plate, cover plate with rectangular section was superior to that with tapered section. It was found that the fatigue crack initiates at the points of stress concentration which are the boundary between the base metal and the bead of weld in the part of the longitudinal edge of attachment, and propagates first along the boundary and along the perpendicular to the direction of the principle stress in the base metal of welded tip.

원환형 덮개장착이 스피너 장비의 기류에 미치는 영향 (EFFECTS OF PLACEMENT OF A TORUS PLATE COVER ON AIR FLOW IN A SPINNER EQUIPMENT)

  • 곽호상;양진오;이상우;박상희
    • 한국전산유체공학회지
    • /
    • 제11권3호
    • /
    • pp.52-58
    • /
    • 2006
  • A numerical investigation is made of air flow in a spinner equipment used for cleanning and drying flat display panels. A unique feature of the spinner under question is the placement of a torus plate cover over the rotating plate. The turbulent flow is driven by rotation of a large disk and suction by the exhaust system connected to vacuum chamber. The flow is modelled as an axisymmetric two-dimensional flow and computation is conducted by using the FLUENT package with a version of k-$\varepsilon$ turbulence model. The required capacity of the exhaust system is assessed numerically. The usefulness of the cover in controlling air flow circulation is examined. A computational trouble shooting is attempted to resolve the problem of panel rising which occurred in real experiment.

연약지반상 고속철도 노반 축조시 지오셀 시스템의 효과 (Reinforcement of Soft Soil Subgrade for High-Speed Railroad Using Geocell)

  • 김진만;조삼덕;윤수호;정문경;김영윤
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 토목섬유 학술발표회 논문집
    • /
    • pp.129-141
    • /
    • 1999
  • This paper presents the results of plate load test and dynamic load test performed to evaluate the performance of geocell where it is used to reinforce soft subgrade for high-speed railroad. Efficacy of geocell was observed in increase in bearing capacity of subgrade and reduction of thickness of reinforced sub-ballast. Plate load tests were carried out at four different places with varying foundation soil strength as a function of number of geocell layer, type of filler material, thickness of cover soil, and the presence of non-woven geotextile. Dynamic load tests were performed in a laboratory. The test soil chamber consists of, from the bottom, 50 cm thick clayey soil, one layer of geocell filled with crushed stone, 10 cm thick crushed stone cover, reinforced sub-ballast of varying thickness, 35 cm thick ballast. This configuration was determined based on the results of numerical analysis and plate load tests. For each set of the dynamic load tests, loads were applied more than 80,000 times. One layer of geocell underlying a 10 cm thick cover soil led to an increase in bearing capacity three to four times compared to a crushed stone layer of the same thickness substituted for the geocell and cover soil layer. Given the test conditions, the thickness of reinforced sub-ballast can be reduced by approximately 35 cm with the presence of geocell.

  • PDF

슬라이딩 커버의 신뢰성 시험 및 구조개선 연구 (A study on the Reliability Experiment and the Structural Improvement of Sliding Cover)

  • 송준엽;강재훈;김태형;김옥구
    • 한국정밀공학회지
    • /
    • 제22권7호
    • /
    • pp.146-154
    • /
    • 2005
  • Recently, the high-speed and intelligence technology of machine tools are developed for the high efficiency of productivity Under the operating condition from the high-speed of machine tools, the various failure modes can occur in core units of manufacturing system. Therefore it is for the reliability concept of machine tool to be required in a design level. And the above-stated technology must be accommodated in the feeding and spindle subsystem, etc those are the core units of machine tools. In this study, we are developed the test-bed of sliding cover (C-plate) in order to evaluating reliability and estimating failure modes of feeding subsystem under operating conditions. The reliability experiment using the developed test-bed and the additional structural analysis executed on single and double structure. We found out the weak parts of sliding cover and were able to predict a life cycle from the experiment results. In this study, we propose the new C-plate model with double link structure to apply the high-speed machine tool in the fundamental guideline.