• 제목/요약/키워드: coupling slab

검색결과 68건 처리시간 0.029초

복합적층판 이론에 의한 철근콘크리트 슬래브교의 해석 (Analysis of Reinforced Concrete Slab Bridges by the Composite Laminates Theory)

  • 한봉구;김덕현
    • 복합신소재구조학회 논문집
    • /
    • 제1권1호
    • /
    • pp.9-15
    • /
    • 2010
  • In this paper, A reinforced concrete slab bridges is analyzed by the composite laminates theory. Both the geometry and the material of the cross section of the reinforced concrete slab bridge are considered symmetrical with respect to the mid-surface so that the bending extension coupling stiffness, Bij = 0, and D16 = D26 = 0. Each longitudinal and transverse steel layer is regarded as a lamina, and material constants of each lamina is calculated by the use of rule of mixture. This slab with simple support is under uniformly distributed vertical and axial loads. In this paper, the finite difference method and specially orthotropic laminates theory are used for analysis. The result of specially orthotropic laminates theory analysis is modified to obtain the solution of the beam analysis. The result of this paper can be used for reinforced concrete slab analysis by the engineers with undergraduate study in near future.

  • PDF

벽식 아파트 구조에서 연결부재의 거동특성을 고려한 비선형 동적 응답 (Nonlinear Dynamic Response of Well-Slab Apartment Building Considering The Behavior of Coupling Elements)

  • 김기현;장극관;서대원;천영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.437-442
    • /
    • 2002
  • The purpose of this study is to investigate nonlinear behavior and estimate ultimate resistance of the wall structure against seismic loading. Experimental data for RC coupling elements are used for specifying the strength deterioration and stiffness degradation factor of hysteretic model. Modified coupling element models are used in the push over analysis and time history analysis. In the time history analysis, three earthquake waves are used in the analysis and their peak ground accelerations are changed to be 0.2g. The conclusions of this study are as follows : (1) In the push over analysis, yielding of coupling elements occurred at lower story with small story drift ratio as 0.3%. (2) In the time history analysis, the story drift ratio is sufficient for the requirement of Korean Code, But coupling elements at most stories of the buildings occurred yielding. i. e. the earthquake resistant capacity of shear wall structures is not sufficient at 0.2g.

  • PDF

The effectiveness of position of coupled beam with respect to the floor level

  • Yasser Abdal Shafey, Gamal;Lamiaa K., Idriss
    • Coupled systems mechanics
    • /
    • 제11권6호
    • /
    • pp.557-586
    • /
    • 2022
  • In spite of extensive testing of the individual shear wall and the coupling beam (CB), numerical and experimental researches on the seismic behavior of CSW are insufficient. As far as we know, no previous research has investigated the affectations of position of CB regarding to the slab level (SL). So, the investigation aims to enhance an overarching framework to examine the consequence of connection positions between CB and SL. And, three cases have been created. One is composed of the floor slab (FS) at the top of the CB (FSTCB); the second is created with the FS within the panel depth (FSWCB), and the third is employed with the FS at the bottom of the CB (FSLCB). And, FEA is used to demonstrate the consequences of various CB positions with regard to the SL. Furthermore, the main measurements of structure response that have been investigated are deformation, shear, and moment in a coupled beam. Additionally, wall elements are used to simulate CB. In addition, ABAQUS software was used to figure out the strain distribution, shear stress for four stories to further understand the implications of slab position cases on the coupled beam rigidity. Overall, the findings show that the position of the rigid linkage among the CB and the FS can affect the behavior of the structures under seismic loads. For all structural heights (4, 8, 12 stories), the straining actions in FSWCB and FSLCB were less than those in FSTCB. And, the increases in displacement time history response for FSWCB are around 16.1-81.8%, 31.4-34.7%, and 17.5% of FSTCB.

포스트텐션된 철근콘크리트 슬래브의 보 이론에 의한 연구 (A Study on Post-Tensioned Reinforced Concrete Slab by the Beam Theory)

  • 한봉구;김덕현
    • Composites Research
    • /
    • 제22권5호
    • /
    • pp.24-29
    • /
    • 2009
  • 본 논문에서는 포스트텐션된 철근콘크리트 슬래브를 특별직교이방성 복합적층판 이론으로 해석하였다. 슬래브의 해석에 있어 단면의 기하학적, 물리적 특성이 중립면에서 휨-연계강성 $B_{ij}=0$ 이고, $D_{16}=D_{26}=0$ 임을 고려하였다. 철근콘크리트 슬래브는 특별직교이방성판으로 거동한다. 이러한 경계조건을 갖는 단면 혹은 불규칙한 단면을 갖는 시스템은 해석적 해를 구하기가 매우 어렵다. 이러한 문제에 대한 해석을 위해서 유한차분법이 이용되었다. 본 논문에서는 유한차분법과 보 이론을 해석을 위해 사용되었다. 그 결과 보 이론에 의한 해석 값이 판 이론의 값에 근접함을 알 수 있었다.

개구부 신설에 따른 병렬 전단벽의 거동특성 (Behavior of Coupling Shear Wall with New Openings)

  • 최현기;최윤철;최창식
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권5호
    • /
    • pp.152-160
    • /
    • 2008
  • 벽식 구조 형식의 아파트는 횡력에 저항하는 주요 부재로 내력벽을 사용하기 때문에 내력벽에 개구부를 설치함으로써 발생하는 단면손실로 인한 내력 손실은 구조물 전체에 심각한 문제를 발생시킬 수도 있다. 또한 개구부 설치에 따라 발생되는 연결보(개구부 상부의 인방)및 연결 슬래브(인방이 없을 경우)에 대한 평가는 미흡한 실정이다. 이에 본 연구에서는 개구부를 설치한 전단벽의 연결부재에 따른 벽체의 거동특성을 알아보고자 1/2 축소된 2층 독립 전단벽체를 계획하였다. 실험결과 개구부 설치에 따른 유효 단면 감소에 의한 내력 감소가 나타났으며, 강성, 에너지 소산능력 등에 있어 연결부재인 연결보와 연결슬래브에 따라 차이를 보였다.

콘크리트 슬래브궤도에서 ATP시스템 지상자의 주파수가 철근에 미치는 영향 (The Influence of Frequency on Wayside Transmitter of ATP System upon Reinforcing Bars in Concrete Slab Track)

  • 김민석;이종우;고준석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.691-706
    • /
    • 2008
  • ATP(Automatic Train Protection) system in railway signaling system is the important one grasping the position and velocity of a train. The wayside transmitter of ATP system is installed between rails. In concrete slab track, the signal current using wayside transmitter of ATP system is influenced by reinforcing bars. The magnetic coupling between reinforcing bars and wayside transmitter of ATP system as a filter makes an input current distorted. So, it makes an alternating current signal with a desirable size not transmit to on-board system of a train. Way to decrease the distortion of an input current signal frequency is to avoid maximum induction current frequency. And the induction phenomenon between reinforcing bars insulated and wayside transmitter of ATP system does not occur. In this paper, we represent the model about wayside transmitter of ATP system and reinforcing bars on the concrete slab tracks, and calculated the parameters demanded for the model. Also, we demonstrated it through the Maxwell program. Furthermore, we calculated impedance on wayside transmitter used in KVB system and ERTMS/ETCS system which are a kind of ATP system, frequency response of induction current, using the Matlab, and demonstrated the validity of it, using the PSpice program.

  • PDF

Effect of a Conductor Cladding on a Dielectric Slab for Coupling with a Side-polished Fiber

  • Kwon, Kwang-Hee;Song, Jae-Won
    • Journal of the Optical Society of Korea
    • /
    • 제7권3호
    • /
    • pp.180-187
    • /
    • 2003
  • A theoretical presentation by using a three-dimensional finite difference beam propagating method (3-D FD-BPM) for the evanescent coupling is offered with respect to the refractive indexes between a side-polished optical fiber and an infinitely planar waveguide with a conductor cladding (PWGCC). The PWG is suspended at a constant distance from an unclad fiber core and attached with a perfect conductor (PEC) on one side. The coupling and propagation of light are found to depend on both the relationship between the refractive index values of two structures and the configuration of the side-polished fiber used in the PWGCC. The spreading of light in the unconfined direction of a PWGCC is presented with the distribution of electric fields in xy - plane and the absolute amplitude of electric fields along the x and y axis. The power of the light propagation in a fiber decreases exponentially along the fiber axis as it is transferred to the PWGCC, where it is carried away.

$VO_2와 LiNbo_3$ 로 집적된 2개의 슬랩 도파로에 관한 결합모드 해석 (Coupled-Mode Analysis of Two Slab Waveguides Fabricated with Vanadirum Oxide and Lithium Niobate)

  • 오환술;김영권
    • 대한전자공학회논문지
    • /
    • 제24권3호
    • /
    • pp.510-516
    • /
    • 1987
  • An analysis and numerical computations relating to the coupling of optical modes between two neighboring waveguides are discussed. The waveguides are fabricated with Lithium Niobate as guide 1 and Vanadium Oxide as guide 2. In a wave guide system that incorporates two lossless guides, a complete transfer of power from one guide to another can occur when the waveguides are (1) identical or (2) the modes in each guide have identical phase constants. Here we discuss the coupling effects when the guides are dissimilar with respect to both geometry and losses. In thers results, we show that power transfer can occur between the two guides, one lossy and the other lossless, provided the phase matched condition is satisfied. When properly coupled, the power attenuation varies according to the amount of coupling.

  • PDF

RC Building 구조물의 폭발해석 및 손상평가 (Blast Analysis and Damage Evaluation for Reinforced Concrete Building Structures)

  • 박양흠;윤성환;장일영
    • 대한토목학회논문집
    • /
    • 제41권4호
    • /
    • pp.331-340
    • /
    • 2021
  • 본 논문은 비예측 극한하중인 폭발하중에 노출된 RC building 구조물의 폭발손상평가를 위한 수치해석적 연구이다. 수치해석의 효율성 및 정확성을 높이기 위해, 폭발하중에 대한 정의, 유체-구조 연성을 위한 Euler-Lagrange 커플링 기법 적용, 그리고 고변형률 속도가 고려된 콘크리트 및 강재 재료구성모델이 제안된다. 특히 효율적인 폭발하중 정의를 위해, Euler-FCT 기법을 통하여 TNT 질량에 따른 시간별 압력하중 데이터가 확보되고, 이는 RC building 구조물 총 7 지점의 폭발위치에 적용되며, ANSYS-AUTODYN 솔버에 연결되어 수치 시뮬레이션이 수행된다. 해석결과, TNT 질량 및 폭발 위치에 따라 손상 차이가 발생하였으며, 먼저 TNT 질량 20 kg 일 경우 3 곳의 폭발손상 지점에서 주부재 중 슬래브에서만 중간 및 가벼운 손상이 발생되었고, TNT 질량 100 kg 일 경우 5 곳의 폭발손상 지점 중 3 곳은 슬래브 및 보 부재에서 중간 손상이 발생되었으며, 2 곳은 슬래브에서 심각한 손상이 발생되었다.

콘크리트 슬래브궤도에서 보상 커패시터의 위치 및 전기용량에 대한 연구 (A Study on the location of Compensation Capacitor and Capacitance in the Concrete Slab Track)

  • 김민석;이상혁;고준석;이종우;조수익;유진영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.879-891
    • /
    • 2009
  • Impedance of rails is increased by the magnetic coupling between rails and reinforcing bars in the concrete slab track. Currently, the current of track circuit has been compensated by installing the compensation capacitors on track circuit because of increasing the impedance of rails. In case of a rapid transit railway, the compensation capacitors are installed every 20[m] to compensate the current of track circuit in the concrete slab track. Because the interval of one block for a rapid transit railway is as long as 1500[m], the compensation capacitors are installed about the number of 70$\sim$75 on track circuit. However, in case the compensation capacitors are broken over the number of three, it is a problem that the amplitude of current is under standard amplitude of current which is 0.8[A]. In this paper, it was suggested installing a compensation capacitor by using resonance phenomenon on the concrete slab track. We represent the electrical model of track circuit and the four terminal network, calculate the parameters demanded for the electrical model in the concrete slab track. Also, we computed the position and capacitance of the compensation capacitor about 2040[Hz], 2400[Hz], 2760[Hz], 3120[Hz] which currently is the track circuit frequency in the Gyeongbu rapid transit railway and demonstrated the validity of it, using the Matlab and PSpice program.

  • PDF