Browse > Article
http://dx.doi.org/10.12989/csm.2022.11.6.557

The effectiveness of position of coupled beam with respect to the floor level  

Yasser Abdal Shafey, Gamal (Department of Civil Engineering, High Institute of Engineering Technology)
Lamiaa K., Idriss (Department of Civil Engineering, Sphinx university)
Publication Information
Coupled systems mechanics / v.11, no.6, 2022 , pp. 557-586 More about this Journal
Abstract
In spite of extensive testing of the individual shear wall and the coupling beam (CB), numerical and experimental researches on the seismic behavior of CSW are insufficient. As far as we know, no previous research has investigated the affectations of position of CB regarding to the slab level (SL). So, the investigation aims to enhance an overarching framework to examine the consequence of connection positions between CB and SL. And, three cases have been created. One is composed of the floor slab (FS) at the top of the CB (FSTCB); the second is created with the FS within the panel depth (FSWCB), and the third is employed with the FS at the bottom of the CB (FSLCB). And, FEA is used to demonstrate the consequences of various CB positions with regard to the SL. Furthermore, the main measurements of structure response that have been investigated are deformation, shear, and moment in a coupled beam. Additionally, wall elements are used to simulate CB. In addition, ABAQUS software was used to figure out the strain distribution, shear stress for four stories to further understand the implications of slab position cases on the coupled beam rigidity. Overall, the findings show that the position of the rigid linkage among the CB and the FS can affect the behavior of the structures under seismic loads. For all structural heights (4, 8, 12 stories), the straining actions in FSWCB and FSLCB were less than those in FSTCB. And, the increases in displacement time history response for FSWCB are around 16.1-81.8%, 31.4-34.7%, and 17.5% of FSTCB.
Keywords
ABAQUS; coupling shear wall system; ETABS; finite elements; rigid link; slab level; wall element;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Abaqus, H.K. and Sorensen. (2001), ABAQUS Standard, User's Manual, Vol. 2, Version 6.2, Pawtucket, Hibbitt, Karlsson and Sorensen.
2 Abdel Raheem, S.E., Abdel Zaher, A.K. and Taha, A. (2018), "Finite element modeling assumptions impact on seismic response demands of MRF-buildings", Earthq. Eng. Eng. Vib., 17(4), 821-834.   DOI
3 Alvarez, R., Restrepo, J.I., Panagiotou, M. and Godinez, S.E. (2020), "Analysis of reinforced concrete coupled structural walls via the Beam-Truss Model", Eng. Struct., 220, 111005. https://doi.org/10.1016/j.engstruct.2020.111005.   DOI
4 Aristizabal-Ocfaoa, J.D. (1987), "Seismic behavior of slender coupled wall systems", J. Struct. Eng., 113(10), 2221-2234. https://doi.org/10.1061/(ASCE)0733-9445(1987)113:10(2221).   DOI
5 Committee, A.C.I., American Concrete, I. (2020), Building Code Requirements for Structural Concrete (ACI 318-19), An ACI Standard.
6 Ding, R., Tao, M.X., Nie, X. and Mo, Y. (2018), "Analytical model for seismic simulation of reinforced concrete coupled shear walls", Eng. Struct., 168, 819-837. https://doi.org/10.1016/j.engstruct.2018.05.003.   DOI
7 Eljadei, A.A. (2012), Performance based Design of Coupled Wall Structures, University of Pittsburgh.
8 Engineers, A.S.O.C. (2000), Minimum Design Loads for Buildings and other Structures.
9 Fialko, S.Y. (2017), "Application of rigid links in structural design models", Int. J. Comput. Civil Struct. Eng., 13(3), 119-137. https://doi.org/10.22337/1524-5845-2017-13-3-119-137.   DOI
10 Galano, L. and Vignoli, A. (2000), "Seismic behavior of short coupling beams with different reinforcement layouts", Struct. J., 97(6), 876-885. https://doi.org/10.14359/518.   DOI
11 Harries, K.A., Gong, B. and Shahrooz, B.M. (2000), "Behavior and design of reinforced concrete, steel, and steel-concrete coupling beams", Earthq. Spectra, 16(4), 775-799. https://doi.org/10.1193/1.1586139.   DOI
12 Idriss, L.K. and Gamal, Y.A.S. (2022), "The effect of a rigid connection between the slab and the coupled beam on the seismic performance of the coupling wall system", J. Hunan Univ. Nat. Sci., 49(1), 1. https://doi.org/10.55463/issn.1674-2974.49.1.31.   DOI
13 Kolozvari, K., Terzic, V., Miller, R. and Saldana, D. (2018), "Assessment of dynamic behavior and seismic performance of a high-rise rc coupled wall building", Eng. Struct., 176, 606-620. https://doi.org/10.1016/j.engstruct.2018.08.100.   DOI
14 Kumar, P., Kuldinow, D., Castillo, A., Gerakis, A. and Hara, K. (2021), "Nonlinear dynamics of coupled light and particle beam propagation", Phys. Rev. A, 103(4), 043502. https://doi.org/10.1103/PhysRevA.103.043502.   DOI
15 Lim, E., Hwang, S.J., Cheng, C.H. and Lin, P.Y. (2016), "Cyclic tests of reinforced concrete coupling beam with intermediate span-depth ratio", ACI Struct. J., 113(3), 515.
16 Rezapour, M., Mirghaderi, S. and Rajabnejad, H. (2022), "Performance study of steel coupling beams in coupling shear-wall system", https://doi.org/10.21203/rs.3.rs-1767739/v1.   DOI
17 Lu, X. and Chen, Y. (2005), "Modeling of coupled shear walls and its experimental verification", J. Struct. Eng., 131(1), 75-84. https://doi.org/10.1061/(ASCE)0733-9445(2005)131:1(75).   DOI
18 Ma, Y., Sun, B., Berman, J.W., Taoum, A. and Yang, Y. (2022), "Cyclic behavior of coupled steel plate shear walls with different beam-to-column connections", J. Constr. Steel Res., 189, 107084. https://doi.org/10.1016/j.jcsr.2021.107084.   DOI
19 Ma, Y., Yan, Z., Berman, J.W., Taoum, A. and Tian, W. (2022), "Seismic performance of coupled steel plate shear walls with different degrees of coupling", J. Struct. Eng., 148(9), 04022111. https://doi.org/10.1061/(asce)st.1943-541x.0003386.   DOI
20 Santhakumar, A.R. (1974), "Ductility of coupled shear walls", Doctor of Philosophy, University of Canterbury, Civil Engineering.
21 Singh, V. and Sangle, K. (2022), "Analysis of vertically oriented coupled shear wall interconnected with coupling beams", HighTech Innov. J., 3(2), 230-242. https://doi.org/10.28991/hij-2022-03-02-010.   DOI
22 Tassios, T.P., Moretti, M. and Bezas, A. (1996), "On the behavior and ductility of reinforced concrete coupling beams of shear walls", ACI Struct. J., 93(6), 711-720.
23 Tian, J., Wang, Y., Jian, Z., Li, S. and Liu, Y. (2019), "Seismic performance and design method of PRC coupling beam-hybrid coupled shear wall system", Earthq. Struct., 16(1), 83-96. https://doi.org/10.12989/eas.2019.16.1.083.   DOI
24 Zuo, J.Q., Zhu, B.L., Guo, Y.L., Wen, C.B. and Tong, J.Z. (2022), "Experimental and numerical study of Steel Corrugated-Plate Coupling Beam connecting shear walls", J. Build. Eng., 104662. https://doi.org/10.1016/j.jobe.2022.104662.   DOI
25 Wang, T., Shang, Q., Wang, X., Li, J. and Kong, Z.A. (2018), "Experimental validation of RC shear wall structures with hybrid coupling beams", Soil Dyn. Earthq. Eng., 111, 14-30.  https://doi.org/10.1016/j.soildyn.2018.04.021.   DOI
26 Xuchuan, L., Xinzheng, L., Zhiwei, M., Lieping, Y., Yinquan, Y. and Lin, S. (2009), "Finite element analysis and engineering application of RC core-tube structures based on the multi-layer shell elements", Chin. Civil Eng. J., 42(3), 49-54.