• Title/Summary/Keyword: countermeasure to reduce

Search Result 148, Processing Time 0.023 seconds

Vibration Reduction Method for Discharge Line of Moisture Separator Reheater (습분분리재열기 배수관 진동저감방안)

  • 이준신;손석만;김태룡
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.688-694
    • /
    • 2001
  • The 84m discharge line of moisture separator reheater(MSR) in Kori-2 had been suffered by excessive vibration from the beginning of power generation. In 1993, a complementary measure was taken to reduce the vibration level by adding several supports in the MSR pipeline. However, the piping vibration was beyond the allowable limit and an appropriate countermeasure was required to prevent the fatigue failure of the pipeline from the abnormal vibration. In this study, the vibrational characteristics of MSR pipeline and the countermeasure for abnormal vibration was investigated. Among the several vibration reduction methods, piping layout change by smoothing the pipeline was applied to the MSR pipeline in Kori-2. Applying the countermeasure, the vibration level was found to dramatically reduce from 17cm/sec to l.0cm/sec at the full-power operation condition.

  • PDF

The analysis result of temporary operation of 765 kV transmission line as 345 kV rating (765 kV 송전선로의 345 kV 운전에 따른 계통 해석)

  • Woo, J.W.;Shim, E.B.;Kang, Y.W.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1647-1649
    • /
    • 1998
  • This paper describes the power frequency voltage and its countermeasure when a 765 kV transmission line is directly connected to a 345 kV line and operated at 345 kV voltage. The summary of this result is as follows : The western route of 765 kV transmission line doesn't need any countermeasure to reduce the power frequency voltage at the receiving end. The eastern route of 765 kV transmission needs 100 Mvar(3 phase) capacity of shunt reactor at the receiving end to reduce the power frequency voltage. The use of shunt reactors in the 765 kV transmission lines has unexpected problems, one of which is induction of high voltages on a de-energized circuit of two parallel lines. This paper examined the problem of resonance on two parallel transmission circuits in one routes.

  • PDF

A study on propagation effect and countermeasure of the harmonics generated in high speed traction (고속전철 차량에서 발생한 고조파 파급영향과 그 대책에 관한 연구)

  • Park, S.M.;Kim, J.C.;Kang, C.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.59-61
    • /
    • 2003
  • This paper demonstrates an analysis of harmonics at the high speed railway substation and proved on this countermeasure using the PSCAD/EMTDC simulation tool. First, high speed railway feeding system is composed using PSCAD/EMTDC electrical railway feeding system model in advance. Second, This paper applications line capacitance values as feeder-trolley, trolley-rail and feeder-rail to analysis harmonics more accuracy in advance did not application. This capacitance values calculate using the EMTP(Electro Magnetic Transient Program). Third, the tractions are arranged in the section that substation supplies power, and this paper take the simulation each case(fractions composition amount) to see harmonic propagation from traction to substation. As a result, generated harmonics at traction can confirmed that harmonics did not reduce at utility source. This harmonics have an influence on bulk power system. Finally, this paper introduces the methods of harmonics effect minimum. This paper proved harmonics reduce effect through the passive filters application.

  • PDF

A Study on Harmonics Detection for Power Equipments (전력설비의 고조파진단에 관한 연구)

  • Lee, Buhm;Kim, Yong-Ha;Choi, Sang-Kyu;Kim, Jong-Kuk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.669-672
    • /
    • 2000
  • This paper presents the methodology which analyze the effect of harmonics in power system. Considering the effect of less-harmonics, economic life and system loss, we have made the comprehensive countermeasure. According to the results of studying harmonics diagnosis and countermeasure, the following problems are pinpointed: protection of power system double investment space of the field. Therefore, in the initial stage, the countermeasure of harmonics trouble are set up. h a results, the following work has been done: $\circled1$ Generation source of harmonics and it's effect into en power system $\circled2$ Review of law related to harmonics, $\circled3$ Countermeasures to reduce the harmonics

  • PDF

The Effect Analysis of Missile Warning Radar Using Probability Model (확률 모델을 이용한 미사일 경고 레이다의 효과도 분석)

  • Park, Gyu-Churl;Hong, Sung-Yong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.6
    • /
    • pp.544-550
    • /
    • 2009
  • To analyze the threat decision performance of MWR(Missile Warning Radar) give analysis on condition that we decide the effective threat using the POC(Probability of Over Countermeasure)/PUC(Probability of Under Countermeasure). Thus, we execute the simulation using the Monte-Carlo method to analyze effect, but the execution time of simulation took longer than we expected. In this paper, the effect analysis is proposed using the probability model to reduce the execution time of simulation. We present the setting method of parameter for probability model and the effect analysis result of MWR using the simulation. Also, we present the comparison result of simulation execution time for Monte-Carlo and probability model.

A Secure Masking-based ARIA Countermeasure for Low Memory Environment Resistant to Differential Power Attack (저메모리 환경에 적합한 마스킹기반의 ARIA 구현)

  • Yoo Hyung-So;Kim Chang-Kyun;Park Il-Hwan;Moon Sang-Jae;Ha Jae-Cheol
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.16 no.3
    • /
    • pp.143-155
    • /
    • 2006
  • ARIA is a 128-bit block cipher, which became a Korean Standard in 2004. According to recent research, this cipher is attacked by first order DPA attack. In this paper, we propose a new masking technique as a countermeasure against first order DPA attack and apply it to the ARIA. The proposed method is suitable for low memory environment. By using this countermeasure, we verified that it is secure against first order DPA attack. In addition, our method based on precomputation of inverse table can reduce the computational cost as increasing the number of S-BOX masking.