Analysis of Image and Development of UV Corona Camera for High-Voltage Discharge Detection (고전압 방전 검출용 자외선 코로나 카메라 개발 및 방전 이미지 분석)

  • Kim, Young-Seok;Shong, Kil-Mok;Bang, Sun-Bae;Kim, Chong-Min;Choi, Myeong-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.9
    • /
    • pp.69-74
    • /
    • 2011
  • In this paper, the UV corona camera was developed using the solar blind and Multi Channel Plate(MCP) technology for the target localization of UV image. UV camera developed a $6.4[^{\circ}]{\times}4.8[^{\circ}]$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. UV camera to measure the discharge count and the UV image was developed, compared with a commercial camera, there was no significant difference. In salt spray environments breakdown voltage was lower than the normal state, thereby discharging the image was rapidly growing phenomenon.

A Study on the Technology Measuring Partial Discharge for Long Term Aging Experiments of Insulation Materials (장시간 절연체 열화실험을 위한 부분방전측정기술 연구)

  • Seon, Jong-Ho;Kim, Gwang-Hwa;Park, Jeong-Hu;Jo, Jeong-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.12
    • /
    • pp.665-672
    • /
    • 2000
  • This paper described the measurement technology to analyze the partial discharge characteristics for long term aging of insulations. This system was consisted of high voltage generation and measurement part, PD detection part, digital conversion and signal processing part. We used the VXI system for digital conversion and signal processing part. In the digital conversion part, we studied the error of partial discharge magnitude and memory capacity for reading digital signal with the sampling rate. In the signal processing part, we showed the program algorithm to count pulses and read peak values of partial discharge. The allowable minimum sampling rate of digizer was decided to 250kS/s through analyzing test. We confirmed that this system was very useful in the study of $\phi-q-n$ characteristics of long term PD experiments with specimens being consisted of internal void defects and CIGRE II electrodes.

  • PDF

Condition Monitoring Technique for Heating Cables by Detecting Discharge Signal (방전신호 검출에 의한 히팅 케이블의 상태감시기술)

  • Kim, Dong-Eon;Kim, Nam-Hoon;Lim, Seung-Hyun;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.2
    • /
    • pp.136-141
    • /
    • 2021
  • Heating cables, widely used in office buildings, factories, streets and railways, deteriorate in electrical insulation during operation. The insulation deterioration of heating cables leads to electric discharges that can cause electrical fires. With this background, this paper dealt with a condition monitoring technique for heating cables by the analysis of discharge signals to prevent electrical fires. Insulation deterioration was simulated using an arc generator specified in UL1699 under AC operation, and the characteristic and propagation of discharge signals were analyzed on a 100 meter-long heating cable. Discharge signals produced by insulation deterioration were detected as a voltage pulse because they are as small as a few mV and they are attenuated through propagation path. The frequency spectrum of discharge signals mainly existed in the range from 70 kHz to 110 kHz, and the maximum attenuation of the signal was 84.8% at 100 meters away from the discharge point. Based on the experimental results, a monitoring device, which is composed of a high pass filter with the cut-off frequency of 70 kHz, a comparator, a wave shaper and a microprocessor, was designed and fabricated. Also, an algorithm was designed to discriminate the discharge signal in the presence of noise, compared with the pulse repetition period and the number of pulse counts per 100ms. In the experiment, the result showed that the prototype monitoring device could detect and discriminate the discharge signals produced at every discharge point on a heating cable.

Comparison of Discharge UV Intensity Due to AR Coating of Optic Lens on Polymer Insulator (광학렌즈 AR 코팅에 따른 폴리머애자에서의 방전 자외선 강도 비교)

  • Kim, Young-Seok;Shong, Kil-Mok;Bang, Sun-Bae;Kim, Chong-Min;Choi, Myeong-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.4
    • /
    • pp.35-40
    • /
    • 2012
  • In this study, the ultraviolet (UV) intensity of polymer insulator was measured using the Anti-Reflective (AR) coating lens on the occurrence of corona discharge. The UV intensity was compared before and after the AR coating. Under the 200-260[nm] of UV lens, the reflection rate before AR coating was 7.5~5.5[%] with 85-89[%] of transmission rate. After AR coating, however, the reflection rate decreased to 1.3~1.22[%] with improved transmission (97.4~97.6[%]). Then, the UV intensity by distance was measured in the polymer insulator. According to the measurement, the UV intensity increased 6.5 times at 37.5[%] of Vm/Vbd with 5[m] of distance. As distance increased, the growth rate declined. As high voltage increased, in addition, AR coating was less effective due to the count error caused by the UV sensor pulse signal overlap. Therefore, it appears that it would be more effective to detect corona discharge with 5[m] or less of distance at diagnosis of power facilities by AR coating and UV sensor sensitivity.

Transformer diagnosis using characteristics of corona in Oil (변압기의 고장검출을 위한 유중 코로나 특성 연구)

  • 권태원;곽희로;김재철;김응상;박민규
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1989.10a
    • /
    • pp.65-70
    • /
    • 1989
  • This paper presents resarch results on the use of a corona detector and a pulse counter in order to diagnose for oil transformers. Using these experimental apparatus, tests were carried out on a typical transformer oil containing different carbonized paper and various moisture contents to measure the picocoulomb val-ues and pulse count. Through the result of this study it was found that the picocoulomb values and pulse count of corona were depended on the getting stained in transformer oil. The amplitude of the partial discharge amount and the number of pulse were decreased up to 70 [。c] and then was increased as the oil temperature goes up. It was concluded that the determinati-on level for diagnosis of oil transform-er was taken into account the temperatu-er of transformer oil, The use of pulse counter method, which have been taken the same property of voltage and temperature variation for the corona measurement mothod, considera-bly increase insulator avilability.

  • PDF

Acupuncture Application for Pyometra in a Dog (개에서 개방형 자궁 축농증의 침치료 례)

  • 남치주;양정환;정성목;최지혜;이주명
    • Journal of Veterinary Clinics
    • /
    • v.16 no.2
    • /
    • pp.463-466
    • /
    • 1999
  • A 2.9 kg, eight-year-old Yorkshire terrier bitch with anorexia and vomiting for 2 weeks was referred to the Seoul National University Veterinary Medicine Teaching Hospital. The bitch was diagnosed as open cervix pyometra by clinical sign, radiography, ultrasonography and complete blood count. The owner didn't want surgery. So, we chose the electroacupuncture and antibiotics treatment. Electroacupuncture treatment was performed for 15 days at Zi-Gong-Shu and Luan-Chao-Shu acupoints with electrical stimulus at the frequency of 5 Hz, 2~4 volts and for 20 minutes twice a day and ciprofloxacin (5 mg/kg, IM) was administered once a day. At 15 days after treatment diameter of the uterus was contracted to 6.9 mm and total WBC count was 8.5$\times$10$^3$/㎣, progesteron concentration was 0.24 ng/dl and clinical signs including vaginal discharge were disappeared. The first estrus was detected 5 months after the last treatment. With this results, the electroacupuncture for canine open cervix pyometra was considered to be the useful alternative treatment.

  • PDF

A Study on the EDT Characteristics of TM Work Roll and Variation of Strip Surface Roughness

  • Kim, Soon-Kyung;Moon-Kyung, Kim
    • KSTLE International Journal
    • /
    • v.2 no.2
    • /
    • pp.133-137
    • /
    • 2001
  • This paper investigates the correlation between strip surface roughness and the surface of the work roll. As the actual temper mill(TM) is used, this data will be adopted to another actual temper mill for the application and operation of this experiment. Conclusions are as follows: Electro-discharge texturing(EDT) roll has homogeneous roughness distribution and shape, and also a sinuous peak surface and the life is 2 times longer than that of shot blast texturing(SBT) method. And the higher surface roughness of work roll, the more time is necessary at the EDT method. In the SBT method without the correlation of roughness, but impeller rotation speed with an uncontrollable peak count. The roughness of SBT roll is irregularity compared to that of EDT roll because the work roll roughness is transferred to the strip which was temper rolled, and produces a more desirable image and greater clarity to the color painted steel sheet.

  • PDF

A Study on the Aging Characteristics of Power Capacitors using Electrical Methods (전기적 방법을 이용한 전력용 콘덴서 열화특성 연구)

  • 김은식;김영욱;김종서;윤철섭;박대희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.199-202
    • /
    • 1998
  • Power capacitors are highly reliable equipment due to their completely enclosed configuration. Aging diagnosis system using partial discharge(PD) and acoustic emission(AE) is being highlighted as a research area for degradation of power capacitors. Their dielectric strength can be however reduced due to some stresses such as over-voltage or thermal degradation of the insulation material during their long period of operation. In this paper, it has been developed to express the AE of the EVENT(average amplitude) and HIT(pulse count) according to the source location. And real time measurement of PD signals for aging diagnosis of power capacitors.

  • PDF

Improved PDP Driving Methods Based on Three Wall Charge States

  • Jeong, Ju-Young;Kim, Seok-I;Jung, Young-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.211-214
    • /
    • 2002
  • We present gray scale implementation method based on QMA driving technique. We clarified the mechanism of wall charge quantization through discharge current measurement. We used three wall charge states to implement gray scale. The cells would be one of fully-ON, half-On, and OFF states. We built a five sub-fields 243 level gray scale with sustain pulse count of 2, 6, 18, 54, and 162.

  • PDF

Design and Fabrication of a LabView Based Partial Discharge Analyzer (LabView 기반 부분방전 분석장치의 설계 및 제작)

  • Cha, Hyeon-Kyu;Lee, Jung-Yoon;Park, Dae-Won;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.3
    • /
    • pp.229-235
    • /
    • 2012
  • This paper dealt with the fabrication of a partial discharge (PD) analyzer for insulation diagnosis of power facilities like transformers, cables and gas-insulated switchgears. An analytic algorithm for the phase (${\phi}$), the magnitude (q), and the pulse count (n) of PD pulse was designed and a time-frequency (TF) map algorithm was applied in the system to eliminate noises by analyzing the time and the frequency component of signals. All the algorithms were operated by a LabView graphical program. The detection circuit consists of a coupling capacitor, a detection impedance, and a low noise amplifier. A plane-plane and a point-plane electrode system were fabricated to simulate different types of insulation defects. In the experiment, we could easily understand the characteristics of PD pulses using the prototype PD analyzer.