• Title/Summary/Keyword: corrosion protection

Search Result 561, Processing Time 0.024 seconds

An Experimental Study on the Fire Risk Assessment & Calculation Breakthrough Time through Permeation Test of Chemical Protective Clothing (화학보호복의 화재위험성 및 화학적 투과시험을 통한 파과시간산정에 관한 실험적 연구)

  • Ko, Jae-Sun;Park, Pyoung-Kyu
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.21-30
    • /
    • 2010
  • We have test chemical resistance and flame retardant properties of chemical protective clothing Fabrics by the ASTM and ISO standard methods. The flame retardant test results show that polyethylene is poor in flame resistance but fluoroelastomer add to decabrom is excellent in flame resistance. Especially, nowadays heat protective clothing for firefighters, which is aluminized film layers laminated to aramid fabric, show the excellent flame resistance. However, the chemical resistance test results show that aluminium is high corrosive in 4M NaOH solution alone. The problem of corrosion can be overcome by employing multiple barrier film. Also, based on the result of flame retardant test, duel skin of polymer barrier film add to aluminum film and single skin of fluorinated rubber with flame retardant materials seems to be fit for the chemical protective clothing. Also the thermal protection and heat transfer test results show that TPP and HTI is increased assured that the continued study on fire risk assessment & chemical resistance of chemical protective clothing fabrics will contribute to the upgrade the performances of chemical protective clothing fabrics.

Investigation on optimum corrosion protection potential by electrochemical method of S355ML steel for marine structure in seawater (해양구조물용 S355ML 강의 해수환경 하에서 전기화학적 방법에 의한 최적 방식전위 규명)

  • Jeong, Gwang-Hu;Park, Il-Cho;Han, Min-Su;Kim, Seong-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.145-145
    • /
    • 2016
  • 해양환경용 구조물은 극심한 부식 환경에 노출되어 있고 부식손상으로 인한 직간접적 경제적 손실이 발생하고 있는 상황이다. 이에 대한 방식대책으로써 음극방식법이 선박, 교량, 각종 화학장비에 널리 이용되고 있으며, 이러한 산업분야에 가장 흔히 적용되고 있는 음극방식 중 하나가 피방식체에 일정 전류 또는 음극 전위를 인가하는 외부전원법이다. 이는 전도성 부식환경인 해수환경 하에서 철강 및 해양환경용 구조 재료의 내식성을 월등히 향상시킬 수 있기 때문에 설계에 있어서 고급 내식재료 대신 경제적인 상용 재료를 적용할 수 있어 비용 절감효과를 가질 수 있다. 한편 적정 방식전위에서는 부식손상으로부터 강재를 보호하지만, 과방식 전위에서는 취성이 발생함으로써 내구성 감소의 역효과가 나타날 수도 있기 때문에 최적 방식전위의 규명은 반드시 필요하다. 따라서, 본 연구에서는 S355ML강에 대하여 천연해수 용액에서 다양한 정전위를 조건으로 전기화학실험을 실시하여 최적 방식전위를 규명하고자 하였다. 시험편은 에머리 페이퍼로 2000번까지 연마하였고, 아세톤과 증류수로 세척하여 실험하였다. 전기화학(정전위) 실험은 천연해수 속에서 $1.28cm^2$의 면적만을 노출시켜 진행하였으며, OCP로부터 -2.0V까지의 음극분극 곡선을 분석하여 정전위 조건들을 선정하였다. 그리고 외부 직류전원장치를 이용하여 1,200초 동안 다양한 정전위를 인가하였으며, 기준전극은 Ag/AgCl 전극을 이용하였다. 실험 후에는 주사전자현미경과 3D 현미경을 통해 시험편 표면을 관찰하였으며, 그 결과 일부 음극분극 구간에서 강재 표면에 전착물에 의한 뷸균일한 피막이 형성되었다. 또한, 일정 전위구간에서 용해 및 과전압에 대하여 표면손상 정도를 관찰하여, 해수환경 하에서 S355ML강의 최적 방식전위를 규명하였다.

  • PDF

A Study on the Performance Improvement and Long-Term Strength Properties of Eco-cement Concrete (에코시멘트 콘크리트의 장기강도 특성 및 성능 향상 방안에 관한 연구)

  • Park, Kwang-Min;Lee, Gun-Cheol
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.6
    • /
    • pp.817-826
    • /
    • 2011
  • Concrete using eco-cement has a problem with long-term strength development. However, currently, a long-term strength development mechanism is not confirmed, resulting in a lack of application of eco-cement in construction fields. In this study, the curing humidity influence on development in long-term strength of concrete using eco-cement and the relationship between strength and pore structure were examined. The results showed that wet cured eco-cement with a high water/cement ratio showed serious long-term strength reduction due to non-reduction of pore volume (pore size over 10 nm) in mortar caste with eco-cement. Also, the study results on improvement of long-term strength of eco-cement by partial replacement with ordinary portland cement and finely-ground fly ash showed that both of these alternatives improved long-term strength of concrete caste with eco-cement due to gradual refinement of their micro-structure.

Repair Cost Analysis for RC Structure Exposed to Carbonation Considering Log and Normal Distributions of Life Time (탄산화에 노출된 철근콘크리트 구조물의 로그 및 정규 수명분포를 고려한 보수비용 해석)

  • Woo, Sang-In;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.3
    • /
    • pp.153-159
    • /
    • 2018
  • Many researches have been carried out on carbonation, a representative deterioration in underground structure. The carbonation of RC (Reinforced Concrete) structure can cause steel corrosion through pH drop in concrete pore water. However extension of service life in RC structures can be obtained through simple surface protection. Unlike the conventional deterministic maintenance technique, probabilistic technique can consider a variation of service life but it deals with only normal distributions. In the work, life time-probability distributions considering not only normal but also log distributions are induced, and repair cost estimation technique is proposed based on the induced model. The proposed technique can evaluate the repair cost through probabilistic manner regardless of normal or log distribution from initial service life and extended service life with repair. When the extended service life through repair has log distribution, repair cost is effectively reduced. The more reasonable maintenance strategy can be set up though actual determination of life-probability distribution based on long term tests and field investigations.

The Effect of Nb-doped TiO2 Coating for Improving Stability of NiCrAl Alloy Foam (NiCrAl 합금 폼의 안정성 향상을 위해 코팅된 Nb-doped TiO2의 효과)

  • Jo, Hyun-Gi;Shin, Dong-Yo;Ahn, Hyo-Jin
    • Korean Journal of Materials Research
    • /
    • v.29 no.5
    • /
    • pp.328-335
    • /
    • 2019
  • Nb-doped $TiO_2$(NTO) coated NiCrAl alloy foam for hydrogen production is prepared using ultrasonic spray pyrolysis deposition(USPD) method. To optimize the size and distribution of NTO particles based on good physical and chemical stability, we synthesize particles by adjusting the weight ratio of the Nb precursor solution(5 wt%, 10 wt% and 15 wt%). The morphological, chemical bonding, and structural properties of the NTO coated NiCrAl alloy foam are investigated by X-ray diffraction(XRD), X-ray photo-electron spectroscopy(XPS), and Field-Emission Scanning Electron Microscopy(FESEM). As a result, the samples of controlled Nb weight ratio exhibit a common diffraction pattern at ${\sim}25.3^{\circ}$, corresponding to the(101) plane, and have chemical bonding(O-Nb=O) at 534 eV. The NTO particles with the optimum weight ratio of N (10 wt%) show a uniform distribution with a size of ~18.2-21.0 nm. In addition, they exhibit the highest corrosion resistance even in the electrochemical stability estimation. As a result, the introduction of NTO coated NiCrAl alloy foam by USPD improves the chemical stability of the NiCrAl alloy foam by protecting the direct electrochemical reaction between the foam and the electrolyte. Thus, the optimized NTO coating can be proposed for excellent protection of NiCrAl alloy foam for hydrocarbon-based steam methane reforming(SMR).

A Study on the Development of Remotely CP Potential Measuring Method by using Vehicle (차량을 이용한 원격전위 측정방법 개발에 관한 연구)

  • Ryou, Young-Don;Jo, Young-Do;Kim, Jin-Jun;Seo, Min-Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.5
    • /
    • pp.64-71
    • /
    • 2016
  • According to the urban gas business law, electrical corrosion prevention measures shall be installed to the buried gas pipelines and the pipe-to-soil potentials should be measured at the test box at least once a year. Most of the test boxes installed in urban area are usually located on the road where the vehicle travels, therefore, it is difficult to measure the CP potentials at the test boxes. That is, we need traffic control when carrying out the measurement of the CP potentials on daytime when the traffic is heavy, or we have to measure the potentials in the late night when the traffic is light. To solve these difficulties, we have studied remotely CP potential measuring method by using the patrol car. We have installed solid reference electrodes and data loggers under the test boxes on the site and received the CP potentials from the data loggers when the vehicle moves. It was difficult to send and receive the data because the data logger was located under the ground. We have applied 3 different method including 2 antenna systems to achieve best effective way in receiving the data. We have found the remote CP measuring method by using a car can save more 20 times of measuring time than conventional measuring methods.

Dispersion Method of Silica Nanopowders for Permalloy Composite Coating (퍼멀로이 합금도금을 위한 나노실리카 분산방법에 관한 연구)

  • Park, So-Yeon;Jung, Myung-Won;Lee, Jae-Ho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.4
    • /
    • pp.39-42
    • /
    • 2011
  • The composite electroplating is accomplished by adding inert materials during the electroplating. Permalloy is the term for Ni-Fe alloy and it is used for industrial applications due to its high magnetic permeability, surface wear resistance, corrosion protection. Microhardness for microdevices is enhanced after composite coating and it increases the life cycle. However, the hydroxyl group on the silica makes their surface susceptible to moisture and it causes the silica nanoparticles to be agglomerated in the aqueous solution. The agglomeration problem causes poor dispersion which eventually interrupts uniform deposition of silica nanoparticles. In this study, the dispersion of silica nanoparticles in the permalloy electroplated layer is reported with variation of additives and current densities. The optimum current density was 20 $mA/cm^2$ and the silica content was 9 at% at $50^{\circ}C$. The amount of silica nanopowder codeposition and surface morphologies were influenced with variation of additives. In the bath, smooth surface morphology and relatively high contents of silica nanopowder codeposition were obtained with addition of sodium lauryl sulfate.

Evaluation of Time-Dependent Chloride Resistance in HPC Containing Fly Ash Cured for 1 Year (1년 양생 조건의 Fly Ash를 혼입한 고성능 콘크리트의 시간의존적 염해저항성 평가)

  • Yoon, Yong-Sik;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.52-59
    • /
    • 2018
  • To control chloride attacks which is a representative deterioration in RC(Reinforced Concrete) structures, many studies have been conducted. Above all, a method using mineral admixture was known to be effective for corrosion protection. In this study, durability test about chloride attacks was carried out for concrete specimens containing FA(Fly Ash)-representative concrete mineral admixture and OPC concrete specimens considering 3 different levels of W/B(Water to Binder). Accelerated chloride diffusion coefficient tests referred to Tang's method, total passed charge tests referred to ASTM C 1202, and compressive strength tests based on KS F 2405 were performed at each target age day. Also, based on previous studies of 28 days, time-parameter which is a key parameter for diffusion behavior is evaluated and its relations with compressive strength at the age of 365 days is evaluated. After the age of 49 days, chloride resistance of FA concrete is much improved than that of OPC concrete, which arose out of stable hydrates due to pozzolan reaction of fly ash. Time-parameter of FA concrete is evaluated to be about 1.5 times larger than that of OPC concrete. Also, time-parameter of FA concrete has a linearly decreasing relation while that of OPC concrete has a linearly increasing relation with compressive strength development.

Study on Properties of Natural Adhesives with Lacquer for Ceramic Conservation (옻을 활용한 토기 복원용 천연 접착재료의 특성 연구)

  • Jeong, Se Ri;Kim, Eun Kyung;Yu, Jae Eun
    • Journal of Adhesion and Interface
    • /
    • v.12 no.4
    • /
    • pp.111-116
    • /
    • 2011
  • The characteristics of natural resin, sap of the lacquer tree were examined as an adhesive for the ceramic conservation since it has such outstanding properties like corrosion resistance against acid and alkali, heat-resistance, waterproof, antiseptic and protection against insects. In order to utilize raw lacquer as an adhesive not under the hardening conditions of lacquer like high humidity (RH 75 to 85%) and high temperature (120 to $170^{\circ}C$), but under normal condition, isinglass and animal glue were added to raw lacquer at certain ratio. In addition, the viscosity and the drying time were measured and their possibilities of application were also investigated through measurement of tensile and adhesive strength. As a result of experiment, it was possible to dry at room temperature and RH $50{\pm}5%$ to mix with raw lacquer and glue, and the drying time of sample with animal glue was faster than that of isinglass. Furthermore, the adhesion of sample with glue was increased more than raw lacquer. It seems to be possible to use the environmental friendly traditional adhesive for the ceramic conservation and restoration, if there are studies or examinations of safety of applications on objects and weathering resistance.

A Study on Measures to Achieve Performance and Safety of Air Respirators for Fire Fighters (소방대원용 공기호흡기의 성능안전확보 대책에 관한 연구)

  • Son, Bong-Sei;Oh, Suk-Hwan;Kim, Yeop-Rae
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.77-81
    • /
    • 2012
  • This study of aims to provide basic data for improve the performance of air respirators that generate by bad influencing elements in fire emergency field. With three types of conditions set up for these tests, the pressures of containers have been extracted; the ambient temperatures have been checked, and the generation of moisture inside and outside container have been checked and identified. Specifically, these tests have been conducted at temperatures ranging between $-20{\sim}40^{\circ}C$. The pressures of containers have been extracted to reach between 0.4~0.8 MPa, using a pressure regulating valve. These tests have resulted in no change in the temperature and moisture outside the containers and no generation of moisture inside the containers as well. Although moisture has been generated inside the pressure gauge, the amount of moisture has not exceeded 25 $mg/m^3$, i.e. the limit suggested by the Korean Government. Therefore, it is judged that the moisture generated inside air respirators, which can be the most critical issue in the equipment, is likely to be caused in the process of managing the equipment or replacing air in the equipment at places of end-users, rather than in the process of manufacturing and production of the equipment.