Abstract
This study of aims to provide basic data for improve the performance of air respirators that generate by bad influencing elements in fire emergency field. With three types of conditions set up for these tests, the pressures of containers have been extracted; the ambient temperatures have been checked, and the generation of moisture inside and outside container have been checked and identified. Specifically, these tests have been conducted at temperatures ranging between $-20{\sim}40^{\circ}C$. The pressures of containers have been extracted to reach between 0.4~0.8 MPa, using a pressure regulating valve. These tests have resulted in no change in the temperature and moisture outside the containers and no generation of moisture inside the containers as well. Although moisture has been generated inside the pressure gauge, the amount of moisture has not exceeded 25 $mg/m^3$, i.e. the limit suggested by the Korean Government. Therefore, it is judged that the moisture generated inside air respirators, which can be the most critical issue in the equipment, is likely to be caused in the process of managing the equipment or replacing air in the equipment at places of end-users, rather than in the process of manufacturing and production of the equipment.
Keywords
Air respirator; Corrosion; Compressor; Moisture; Air container;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 C. K. Caretti, D. Scott, W. Johson, Arthur and K. Frank, "Inspiratory Flow Rates During Hard Work When Breathing Through Different Respirator Inhalation and Exhalation Reistances", Journal of Occuapational and Environmental Hygiene (2006).
2 Francis and E. Bicksler "The Effect of Inspiratory Air Humidity and Temperature on Performance Time While Wearing a Espirator", M.S., University of Maryland, College Park (2006).
3 http://www.luxfercylinders.com, Luxfer Carbon Composite Cylinders Inspection Manual (2009).
4 NEMA Bulletin No. 2006-75. "The Safety Notice on the Management of Respiratory Protective Equipment".
5 KFI Standard, "Standard of Model Aapproval & Inspection Technology for Air Self Contained Breathing Apparatus", Korea Fire Institute of Idustry & Technology (2010).
6 NFPA 1401:6.8.4 (2009).
7 C. W. Lee, Y. J. Lee, S. H. Hyun, J. M. Seong, D. M. Choi and M. O. Yoon, "A Study on the Effect of Compressed Air Using Air-breathing Upon Human", Journal of Korea Institute of Fire Science & Engineering, Vol. 18, No. 3, pp. 16-21 (2004).
8 C. W. Lee, Y. J. Lee, S. H. Hyun, J. M. Seong, Y. S. Song, D. M. Choi and M. O. Yoon, "A Study on the Actual Condition for Air Respirators Using Air-breathing", Journal of Korea Institute of Fire Science & Engineering, Vol. 18, No. 4, pp. 95-102 (2004).
9 F. Stowell. "Respiratory Protection for Fire and Emergency Services", Fire Protection Publication Oklahoma State University (2002).
10 J. D. Newnum. "The Effects of Elative Humidity on Respirator Performance", Master's Thsis. Graduate College The University of Iowa (2010).