• Title/Summary/Keyword: correlated noise

Search Result 259, Processing Time 0.027 seconds

Evaluation of One-particle Stochastic Lagrangian Models in Horizontally - homogeneous Neutrally - stratified Atmospheric Surface Layer (이상적인 중립 대기경계층에서 라그랑지안 단일입자 모델의 평가)

  • 김석철
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.4
    • /
    • pp.397-414
    • /
    • 2003
  • The performance of one-particle stochastic Lagrangian models for passive tracer dispersion are evaluated against measurements in horizontally-homogeneous neutrally-stratified atmospheric surface layer. State-of-the-technology models as well as classical Langevin models, all in class of well mixed models are numerically implemented for inter-model comparison study. Model results (far-downstream asymptotic behavior and vertical profiles of the time averaged concentrations, concentration fluxes, and concentration fluctuations) are compared with the reported measurements. The results are: 1) the far-downstream asymptotic trends of all models except Reynolds model agree well with Garger and Zhukov's measurements. 2) profiles of the average concentrations and vertical concentration fluxes by all models except Reynolds model show good agreement with Raupach and Legg's experimental data. Reynolds model produces horizontal concentration flux profiles most close to measurements, yet all other models fail severely. 3) With temporally correlated emissions, one-particle models seems to simulate fairly the concentration fluctuations induced by plume meandering, when the statistical random noises are removed from the calculated concentration fluctuations. Analytical expression for the statistical random noise of one-particle model is presented. This study finds no indication that recent models of most delicate theoretical background are superior to the simple Langevin model in accuracy and numerical performance at well.

An Investigation of Acoustic Signal Characteristics in Turning of Aluminum (알루미늄 선삭공정에서 발생되는 음향 신호 특성)

  • Lee, Chang-Hee;Kim, Yong-Yun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.457-462
    • /
    • 2007
  • This paper reports on the research which investigates acoustic signals acquired in turning with rough and finish simultaneously. The material is aluminum thin pipe. Two acoustic sensors were set on CNC machine. One was set on the finish bite and the other the rough. Two signals were first analyzed in order to consider how much the acoustic signal from the finish bite was coupled by that from the rough. A simple data collecting system to acquire signals from the finish was then determined because two acoustic signals were little coupled. Second the fundamental experiments were accomplished to study the effects of machine vibration and material state. The signal characteristics due to surface defects were studied from the collected acoustic signal data. The signal analysis was based on real time data, root mean squared average and frequency spectrum by fast fourier transform. As a result, the acoustic signals were made effects by machine condition, material structure. The acoustic signal from the finish bite was closely correlated with surface quality. Two types surface micro defects were then evaluated by the signal characteristics.

  • PDF

Single-Channel Non-Causal Speech Enhancement to Suppress Reverberation and Background Noise

  • Song, Myung-Suk;Kang, Hong-Goo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.8
    • /
    • pp.487-506
    • /
    • 2012
  • This paper proposes a speech enhancement algorithm to improve the speech intelligibility by suppressing both reverberation and background noise. The algorithm adopts a non-causal single-channel minimum variance distortionless response (MVDR) filter to exploit an additional information that is included in the noisy-reverberant signals in subsequent frames. The noisy-reverberant signals are decomposed into the parts of the desired signal and the interference that is not correlated to the desired signal. Then, the filter equation is derived based on the MVDR criterion to minimize the residual interference without bringing speech distortion. The estimation of the correlation parameter, which plays an important role to determine the overall performance of the system, is mathematically derived based on the general statistical reverberation model. Furthermore, the practical implementation methods to estimate sub-parameters required to estimate the correlation parameter are developed. The efficiency of the proposed enhancement algorithm is verified by performance evaluation. From the results, the proposed algorithm achieves significant performance improvement in all studied conditions and shows the superiority especially for the severely noisy and strongly reverberant environment.

Design and Evaluation of a CMOS Image Sensor with Dual-CDS and Column-parallel SS-ADCs

  • Um, Bu-Yong;Kim, Jong-Ryul;Kim, Sang-Hoon;Lee, Jae-Hoon;Cheon, Jimin;Choi, Jaehyuk;Chun, Jung-Hoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.1
    • /
    • pp.110-119
    • /
    • 2017
  • This paper describes a CMOS image sensor (CIS) with dual correlated double sampling (CDS) and column-parallel analog-to-digital converter (ADC) and its measurement method using a field-programmable gate array (FPGA) integrated module. The CIS is composed of a $320{\times}240$ pixel array with $3.2{\mu}m{\times}3.2{\mu}m$ pixels and column-parallel 10-bit single-slope ADCs. It is fabricated in a $0.11-{\mu}m$ CIS process, and consumes 49.2 mW from 1.5 V and 3.3 V power supplies while operating at 6.25 MHz. The measured dynamic range is 53.72 dB, and the total and column fixed pattern noise in a dark condition are 0.10% and 0.029%. The maximum integral nonlinearity and the differential nonlinearity of the ADC are +1.15 / -1.74 LSB and +0.63 / -0.56 LSB, respectively.

Application to the Flow in HDD Using PIV Measurement (HDD내 유동장에 대한 PIV 계측 기술의 적용)

  • 공대위;주원구;도덕희
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.742-747
    • /
    • 2004
  • Hard disk drives (HDD) in computer are used extensively as data storage capacity. PIV measurement system was used fur 2-dimensional visualization of the unsteady flow between co-rotating disks in air both with a shroud and both with a actual-like case. Geometric parameters are gap height (H) between disks in the case of shroud. The lobe- structured boundary between inner region and outer region was visualized, and the number of dominant vertices was determined clearly. It is found from flow visualization that the number of vortex cells can be correlated with Reynolds number based on H which is defined as R $e_{H}$ =ΩRH/v ranging from 7.96$\times$10$^2$ to 1.43$\times$10$^4$, and decreases as the disk speed increases. In the case of a actual-like case, the boundary between inner region and outer region appears cleary when head position located at outer diameter with no damper. It is detected with a case of head position middle diameter that the tip wake is generated behind HGA using PIV measurement and calculation.n.

  • PDF

The Study of Correlation between Objective Human Response and Subjective Discomfort Evaluation of Idle Vibration on Passenger Vehicle (승용차량 정차시 발생하는 진동에 대한 객관적 인체반응특성과 주관적 불편함평가의 상관성에 관한 연구)

  • Lee, Jae-Young;Jeon, Gyeoun-Jin;Ahn, Se-Jin;Jeong, Weui-Bong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.455-460
    • /
    • 2012
  • Thirteen taxi drivers as the subject in the experiment were exposed to vertical vibration which is controlled on a rigid seat reflecting vibration on passenger vehicle. They were employed not only to get human response of objective measurement but also to make subjective evaluation of the vibration. The subjective evaluation was estimated using the absolute discomfort threshold of the controlled vibration, which was achieved with the three-down one-up method that is widely used in the field of psychophysics. As the result, apparent mass and apparent eccentric mass as objective human response tend to gradually decrease when frequency of the vibration increases. The absolute discomfort threshold was increased in case of increasing the frequency. Concludingly, the subjective discomfort evaluation is highly correlated with the objective human responses at the range of idle vibration on passenger vehicle.

  • PDF

The Study of Correlation between Objective Human Response and Subjective Discomfort Evaluation of Idle Vibration on Passenger Vehicle (승용차량 정차시 발생하는 진동에 대한 객관적 인체반응특성과 주관적 불편함평가의 상관성에 관한 연구)

  • Lee, Jae-Young;Jeon, Gyeoung-Jin;Ahn, Se-Jin;Jeong, Weui-Bong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.5
    • /
    • pp.422-428
    • /
    • 2012
  • Thirteen taxi drivers as the subject in the experiment were exposed to vertical vibration which is controlled on a rigid seat reflecting vibration on passenger vehicle. They were employed not only to get human response of objective measurement but also to make subjective evaluation of the vibration. The subjective evaluation was estimated using the absolute discomfort threshold of the controlled vibration, which was achieved with the three-down one-up method that is widely used in the field of psychophysics. As the result, apparent mass and apparent eccentric mass as objective human response tend to gradually decrease when frequency of the vibration increases. The absolute discomfort threshold was increased in case of increasing the frequency. Concludingly, the subjective discomfort evaluation is highly correlated with the objective human responses at the range of idle vibration on passenger vehicle.

Sound Metric Design for Quantification of Door Closing Sound Utilizing Physiological Acoustics (생리음향을 이용한 도어 닫힘음의 정량적 평가를 위한 새로운 음질요소의 개발)

  • Shin, Tae-Jin;Lee, Seung-Min;Lee, Sang-Kwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.1
    • /
    • pp.73-83
    • /
    • 2013
  • In previous works, psychoacoustic parameters have been used for objective quantification. However, these parameters do not agree well with subjective assessment. Therefore, the correlation between psychoacoustic parameters and the subjective rating of door closing sounds of sampled cars is low, and it is not sufficient to use psychoacoustic parameters as an objective metric to quantify the sound quality of door closing sounds. In this paper, a new method is proposed to objectively quantify the sound quality based on physiological acoustics and statistical signal processing. The gammatone filter, as a pre-processing, is used in models of the auditory system and kurtosis, which is the fourth-order moment of temporal signal, and is used to extract information about sound quality quantification for door closing sounds. The new metric obtained through the proposed method is highly correlated with subjective rating, and it is successfully applied to the quantification of the sound quality of door closing sounds.

Vibration Monitoring and Power Performance Evaluation of a Small Stand-alone Wind Turbine Generator (소형 독립형 풍력발전기의 진동 모니터링 및 출력 성능 평가)

  • Yoo, N.S.;Kim, Yoon-Ho;Kim, Seock-Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.2 s.119
    • /
    • pp.114-120
    • /
    • 2007
  • Vibration performance of a 6 kW stand-alone wind turbine(W/T) generator is investigated under the wind environment of Daegwanryung mountain area. In the W/T, wind condition, power performance and structural stability are correlated each other An integrated monitoring system which consists of accelerometers, anemometers, power meters and auxiliary sensors for atmospheric data are constructed to measure the required data simultaneously. Based upon the data acquired over a long period of time, vibration performance of the W/T structure is estimated with annual wind data and generating power performance. Within the operating speed range, possibility of severe nitration is diagnosed. Vibration sources are identified and countermeasures are proposed. The goal of the study is to offer the basic information on W/T vibration performance at the design stage of a small stand alone W/T structure.

Accuracy evaluation of diagnostic parameters estimated by uroflowmetry technique measuring hydraulic pressure (수압측정 방식의 요류검사 진단매개변수의 정확도 평가)

  • Kim, Kyung-Ah;Choi, Seong-Su;Kim, Sung-Sik;Kim, Kun-Jin;Park, Kyung-Soon;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.413-418
    • /
    • 2007
  • Uroflowmetry is of great convenience to diagnose benign prostate hypertrophy common in aged men. The urinary flow rate is obtained by weight measurement using load cell, however, sensitive to impact noise. An alternative technique was recently proposed to measure hydraulic pressure instead of weight and demonstrated to introduce significantly reduced noise. In this paper, we described the measured diagnostic parameters between the weight and pressure measuring techniques in 10 normal men. The weight and pressure signals were simultaneously acquired during urination, converted into urine volumes, then differentiated to obtain flow rate signals, which showed very similar waveforms. Diagnostic parameters evaluated by pressure measuring technique were well correlated with the standard weight measuring technique (correlation coefficient > 0.99). Therefore, the new uroflowmetry based on hydraulic pressure measurement can provide accurate diagnostic parameters, which would be clinically valid.