• Title/Summary/Keyword: core temperature

Search Result 1,684, Processing Time 0.034 seconds

Oogenesis and Reproductive Cycle of Glossaulax didyma on the West Coast of Korea (한국 서해산 큰구슬우렁이, Glossaulax didyma의 난자형성과정 및 생식주기)

  • Kim, Dae-Gi;Chung, Ee-Young;Kim, Eun-Jong
    • The Korean Journal of Malacology
    • /
    • v.22 no.1 s.35
    • /
    • pp.13-22
    • /
    • 2006
  • Gonadosomatic index (GSI), oogenesis and reproductive cycle of Glossaulax didyma were investigated by the cytological histological obserbations and morphometric data. Samples were collected monthly from the intertidal zone of Biin Bay, Seocheon, Korea, for one year. Monthly variations in the GSI showed similar patterns with gonadal development. In the early vitellogenic oocyte, the Golgi complex and mitochondria were invovled in the formation of lipid droplet and yolk precursor. In the late vitellogenic oocytes, the rough endoplasmic reticulum and multivesicular bodies were involved in the formation of profeid yolk granules in the cytoplasm. A mature yolk granule was composed of three components: main body (central core), superficial layer, and the limiting membrane. The spawning season was from early June to late August, and the main spawning occurred between July and August when the seawater temperature was above $19^{\circ}C$. The female reproductive cycle can be classified into five successive stages: early active stage (December to February), late active stage (February to March), ripe stage (April to July), spawning stage (June to August), recovery stage (August to November). Fully mature oocytes were approximately $250-270{\mu}m$ in diameter.

  • PDF

Forced Flow Dryout Heat Flux in Heat Generating Debris Bed (열을 발생하는 Debris층에서의 강제대류 Dryout 열유속)

  • Cha, Jong-Hee;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • v.18 no.4
    • /
    • pp.273-280
    • /
    • 1986
  • The purpose of this study is to obtain the experimental data of the forced flow dryout heat flux in a heat generating debris bed which simulates the degraded nuclear reactor core after severe accident. An experimental investigation has been conducted of dryout heat flux in an inductively heated bed of steel particles with upward forced flow rising coolant circulation system under atmospheric pressure. The present observations were mainly focused on the effects of coolant mass flux, particle size, bed height, and coolant subcooling on the dryout heat flux The data were obtained when carbon steel particles in the size distribution 1.5, 2.5, 3.0 and 4.0 mm were placed in a 55 mm ID Pyrex glass column and inductively heated by passing radio frequency current through a multiturn work coil encircling the column. Distilled water was supplied with variation of mass flux from 0 to 3.5 kg/$\textrm{cm}^2$ s as a coolant in the tests, while the bed height was selected as 55 mm and 110 mm. Inlet temperature of coolant varied by 2$0^{\circ}C$ and 8$0^{\circ}C$. The principal results of the tests are: (1) Dryout heat flux increases with increase of upward forcing mass flux and particle size; (2) The dryout heat flux at the zero mass flux obviously depends on the Particle size as Previous studies; (3) The forced flow dryout heat flux in the shallow bed is somewhat higher than that in the deep bed,

  • PDF

Optimal Design of a Coil for Improved Heating Efficiency of Electric Induction Boiler (전기유도보일러의 발열효율개선을 위한 권선최적설계)

  • Kim, Youn-Hyun;Kim, Sol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.476-482
    • /
    • 2019
  • Regulatory protocols such as the Convention on Climate Change and the regulation of greenhouse gas emissions act as catalysts for the development of high-efficiency energy equipment and the efficient use of energy. Among the fields where energy consumption is high, the electric heating equipment is not efficient. The electric boiler mainly uses a method of circulating water by contacting the heater. When the existing electric boiler is used, the water minerals are contacted with the high-temperature heater to be carbonized and adsorbed, thereby promoting the corrosion of the heater and lowering the efficiency of the heater. For this reason, an electric induction boiler, which has high energy efficiency and is applied to an induction heating system that can uniformly heat the object to be heated rather than conduction or convection heating, is in the limelight. This method induces a boiler pipe And it is recognized as an alternative that can solve the problem that occurs when heating is performed by direct heating. Despite the fact that research on induction heating has been conducted for a relatively long period of time, there have been few studies on the electrothermal technology using induction heating. Therefore, in this paper, to improve the heat efficiency of electric induction boiler, the influence of the cross sectional area, number of windings and winding layers is analyzed by finite element method through parametric study method. The method of finding the design point which maximizes the total loss is proposed by the alternating winding design method which can maximize the heat generation by analyzing copper and iron losses.

Design and Implementation K-Band EWRG Transceiver for High-Resolution Rainfall Observation (고해상도 강수 관측을 위한 K-대역 전파강수계 송수신기 설계 및 구현)

  • Choi, Jeong-Ho;Lim, Sang-Hun;Park, Hyeong-Sam;Lee, Bae-Kyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.5
    • /
    • pp.646-654
    • /
    • 2020
  • This paper is to develop an electromagnetic wave-based sensor that can measure the spatial distribution of precipitation, and to a electromagnetic wave rain gauge (hereinafter, "EWRG") capable of simultaneously measuring rainfall, snowfall, and wind field, which are the core of heavy rain observation. Through this study, the LFM transmission and reception signals were theoretically analyzed. In addition, In order to develop a radar transceiver, LFM transceiver design and simulation were conducted. In this paper, we developed a K-BAND pulse-driven 6W SSPA(Solid State Power Amplifiers) transceiver using a small HMIC(Hybrid Microwave Integrated Circuit). It has more than 6W of output power and less than 5dB of receiving NF(Noise Figure) with short duty of 1% in high temperature environment of 65 degrees. The manufactured module emits LFM and Square Pulse waveform with the built-in waveform generator, and the receiver has more than 40dB of gain. The transceiver developed in this paper can be applied to the other small weather radar.

A Study on Operation Control Technology Required for Introduction of Intelligent Sewage Treatment Plant (스마트 하수처리장 도입에 필요한 운전제어기술에 관한 연구)

  • Lee, Jiwon;Kim, Yuhyeon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.24 no.1
    • /
    • pp.38-43
    • /
    • 2022
  • Smart sewage treatment plant means creating a safe and clean water environment by establishing an ICT-based real-time monitoring, remote control management and intelligent system for the entire sewage treatment process. The core technology of such a smart sewage treatment plant can be operation control technology using measuring instruments. This research team analyzed and suggested the operation control technologies necessary for the establishment of the intelligent business by referring to the intelligent research projects of the sewage treatment plant in progress in Korea. As a result of the analysis, a total of six removal technologies were presented, including control by scale, reflow water control, linked treated water control, chemical quantity control, winter operation control, and total organic carbon control. By size, standards that can be classified into small and medium-sized large-scale are presented, and in the case of reflow water control, the location of water quality and flow sensors capable of managing reflow water is suggested. In the case of the linked treated water control, the influence and control points of the linked treated water on the sewage treatment plant were presented, and in the case of the chemical injection volume control, a system capable of optimizing the amount of chemical injection according to the introduction of an intelligent sewage treatment plant was presented. In the case of winter operation, the sensors and pumps to be controlled are suggested when considering the decrease in nitrification due to the decrease in water temperature. In the case of total organic carbon control, an interlocking system considering the total amount of pollution in the future was proposed. These operation control scenarios are expected to be used as basic data to be used in intelligent sewage treatment algorithms and scenarios in the future.

Effect of Moulding Conditions on Properties of Table Top for Student Desk Manufactured by Wood Waste Materials (폐기 목질 재료로 제조한 학생용 책상 천판의 성능에 미치는 성형조건의 영향)

  • Roh, Jeang-Kwan;Kim, Jae-Kyung;Kim, Sa-Ick;Jo, Jong-Soo;Yoon, Seung-Lak;Ra, Jong-Bum;Do, Jeong-Lak
    • Journal of the Korean Wood Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.106-113
    • /
    • 2002
  • This research was performed to investigate the effect of moulding conditions on properties of the table top for student desk manufactured by wood waste materials. The table top manufactured using the mat mixed properly with fine particles and coarse particles generally showed better physical properties than those manufactured using either fine particles or coarse particles did/ Especially, highest performance for overlaying was observed when fine particles were used for face layer and coarse particles were used for core layer. The internal bond (IB) strength, the bending strength and thickness swelling increased with the increase of density. Most of physical properties were improved with the increase of hot pressing temperature. The best physical properties were found at 190℃ when the first hot pressing and the second hot pressing times were two minutes. However, the effect of the second hot pressing time of two minutes on the physical properties was not markedly different from that of one minute. This result suggests that the second hot pressing time of one minute is enough to increase the productivity in manufacturing the table top with the least decrease of the physical properties.

Emissions and Combustion Dynamics with Fuel Injection Position for Low-swirl Nozzles of Gas Turbine Combustor (복합발전 가스터빈 연소기용 저선회 노즐의 연료 분사 위치에 따른 배기배출 및 연소진동 특성)

  • Jeongjae, Hwang;Won June, Lee;Min Kuk, Kim;Han Seok, Kim
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.37-44
    • /
    • 2022
  • In this study, two low-swirl nozzles with the same SN (Swirl Number) but different mass ratio (m) of the core part and the swirler part were designed to perform an atmospheric pressure combustion test. For each nozzle, a combustion test was conducted according to the adiabatic flame temperature, and the flame structure, emissions, and combustion instability mode were identified. Although the flame structure was significantly different, the CO emission was similar, and the NOx emission was also more related to combustion dynamics than the flame structure. Combustion dynamics and NOx emission were identified while adjusting the convection delay time by changing the position of the fuel injection nozzle. It was confirmed that when the convection delay time is in the region of (3+4n)/4T±1/4T (n=0,1,2,...), the combustion instability is strong, and in the opposite case, the combustion instability is very weak.

Implementation of Responsive Web-based Vessel Auxiliary Equipment and Pipe Condition Diagnosis Monitoring System (반응형 웹 기반 선박 보조기기 및 배관 상태 진단 모니터링 시스템 구현)

  • Sun-Ho, Park;Woo-Geun, Choi;Kyung-Yeol, Choi;Sang-Hyuk, Kwon
    • Journal of Navigation and Port Research
    • /
    • v.46 no.6
    • /
    • pp.562-569
    • /
    • 2022
  • The alarm monitoring technology applied to existing operating ships manages data items such as temperature and pressure with AMS (Alarm Monitoring System) and provides an alarm to the crew should these sensing data exceed the normal level range. In addition, the maintenance of existing ships follows the Planned Maintenance System (PMS). whereby the sensing data measured from the equipment is monitored and if it surpasses the set range, maintenance is performed through an alarm, or the corresponding part is replaced in advance after being used for a certain period of time regardless of whether the target device has a malfunction or not. To secure the reliability and operational safety of ship engine operation, it is necessary to enable advanced diagnosis and prediction based on real-time condition monitoring data. To do so, comprehensive measurement of actual ship data, creation of a database, and implementation of a condition diagnosis monitoring system for condition-based predictive maintenance of auxiliary equipment and piping must take place. Furthermore, the system should enable management of auxiliary equipment and piping status information based on a responsive web, and be optimized for screen and resolution so that it can be accessed and used by various mobile devices such as smartphones as well as for viewing on a PC on board. This update cost is low, and the management method is easy. In this paper, we propose CBM (Condition Based Management) technology, for autonomous ships. This core technology is used to identify abnormal phenomena through state diagnosis and monitoring of pumps and purifiers among ship auxiliary equipment, and seawater and steam pipes among pipes. It is intended to provide performance diagnosis and failure prediction of ship auxiliary equipment and piping for convergence analysis, and to support preventive maintenance decision-making.

Analysis of Noticing Characteristics Presented in Elementary Pre-service Teachers' Self-reflection Journals on the Science Class (초등 예비교사의 과학수업 성찰지에 나타난 노티싱 특성 분석)

  • Yoon, Heojeong
    • Journal of Korean Elementary Science Education
    • /
    • v.41 no.4
    • /
    • pp.754-770
    • /
    • 2022
  • For teachers, noticing refers to paying attention to something, indicating they interpret it and how they are willing to react to it in the context of their own instruction. Analysis of noticing features enables us to understand the overall characteristics of the teacher's lesson design, practice, and reflection, which are core agents in the educational design and implementation. This can also be taken to be the basis of education design for competency reinforcement for teachers. Therefore, in this study, the characteristics of noticing shown in teachers' reflections after class design and demonstration were identified. For this purpose, the self-reflection journals of 106 elementary pre-service teachers enrolled in the College of Education in Gangwon-do were analyzed. In particular, the journals were gathered that were written after the demonstration dealing with the change of gas volume by temperature in science class. After designing a noticing analysis frame consisting of the five dimensions 'agent', 'stage', 'topic', 'focus', and 'stance', the frequency and ratio of noticing by each dimension's components were derived. The frequency and ratio of noticing for the dimension of 'focus' were analyzed for the dimensions of 'stage' and 'topic'. The results of the study were as follows. For the dimension of 'agent', the frequency of teacher and student was the highest, and for the dimension of 'stage', inquiry activity was the highest. For the 'topic' dimension, class design according to the teaching strategy appeared most frequently, and in the 'focus' dimension, the cases that did not specify the goal of the class and the competencies to be achieved by the students appeared most frequently. In the 'stance' dimension, description showed the highest frequency. From the analysis of how the 'focus' changes according to the 'stage' and 'topic', it was found that a characteristic focus appeared for each component of the dimension. From these results, the implications of the noticing characteristics of pre-service teachers for the design and implementation of teacher education were discussed.

A Rigorous Examination of the Interplay Between Fire Resistance of 1-Hour Rated Fireproof Steel Walls and the Flexural Strength of Individual Panels (1시간 내화구조용 철강재 벽체의 내화성능과 단위 패널 휨강도의 관계 고찰)

  • Jeon, Soo-Min;Ok, Chi-Yeol;Kang, Sung-Hoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.5
    • /
    • pp.537-546
    • /
    • 2023
  • For the purpose of fire delineation within buildings, steel walls in Korea are mandated to undergo rigorous certification as fire-resistant entities, substantiated via a series of qualitative assessments. Predominantly, these evaluations comprise the fire resistance test paired with supplementary examinations; specifically for steel walls, these encompass the gas hazard and panel bending strength tests. Given the prevalence of semi-noncombustible core materials, gas hazard tests are largely rendered superfluous, pivoting the focus solely onto the panel bending strength test during the certification trajectory. This particular test is designed to gauge the flexural robustness of individual wall panels. An enhanced bending strength is postulated to fortify both the structural integrity and thermal insulation of the wall by mitigating potential deformations. In this scholarly exploration, an analytical deep dive was undertaken into extant, valid certification test datasets. The endeavor aimed to ascertain the depth of correlation between the designated fire resistance metric and the bending strength, the latter being the sole supplementary assessment for steel walls. In distilling the findings, it was discerned that temperature elevations beyond baseline values exhibited no statistically salient linkage with the panel's bending strength.