• 제목/요약/키워드: core buckling

검색결과 181건 처리시간 0.023초

연사방법에 따른 면/폴리에스테르 복합사 편성물의 역학적 특성 및 3D CAD System에 의한 외관특성 (Mechanical properties and 3D CAD Images of the Appearance of Cotton/Polyester Composite Yarn Knitted Fabric by Different Yarn Twisting Methods)

  • 김소진;전동원;박영환
    • 한국염색가공학회지
    • /
    • 제18권3호
    • /
    • pp.49-58
    • /
    • 2006
  • The purpose of this study was to examine the effect of covering yarn's twist on mechanical properties of knitted fabrics of composite yarns with single covering process. Four yarns that were used in this study: two different composite yarns made from the four kinds of cotton and functional polyester-(Poly-A) with the ratio of 52:48, and the rest two yarns are the original cotton 100% yarn and the poly-A 100% yarn. The two kinds of composite yarns, CP1 and CP2, were processed on the single covering process. CP1 was applied on the single covering process with S-800 tpm, where Poly-A was used as covering yarn and cotton was used as core yarn. CP2 was applied on the same process as CP1 except that Poly-A had been applied on the two-for-one twisting process with S-400 tpm on the previous step. Sixteen mechanical properties of all the four knifed fabrics knitted under the same knitting conditions were measured by KES-FB system with the outer knit condition. And 3D CAD dressmaking simulations, which were driven by some of the mechanical properties, were presented. The results were as follows: CP2 had high RT values with twisting of covering yarn. CP2 also had high B, 2HB values because of higher linear density. SMD was affected rather by twisting of covering yarn than by fine hair of the cotton surface. Twisting of covering yarn made it decreasing T value and increasing W value. Dressmaking 3D CAD simulations showed that there are buckling effects on CP2 because of high bending rigidity and shear rigidity.

주기하중을 받는 이중강판합성벽의 실험연구 (Experimental Study on Double Skin Composite Walls Subjected to Cyclic Loading)

  • 엄태성;박홍근;김진호;장인화
    • 한국강구조학회 논문집
    • /
    • 제20권2호
    • /
    • pp.289-301
    • /
    • 2008
  • 이중강판합성벽은 타이바로 연결된 강판외피 사이에 콘크리트를 충전시킨 구조벽으로서, 벽체의 구조성능을 향상시키고, 벽체의 두께를 줄이며, 별도의 거푸집 및 배근 공사없이 시공성을 향상시키기 위하여 개발되었다. 본 연구에서는 주기하중을 받는 이중강판합성벽의 비탄성거동특성 및 내진성능을 평가하기 위하여, 직사각형 및 T형 단면형상을 갖는 단일벽 및 병렬벽 실험체에 대하여 실험 연구를 수행하였다. 실험 결과, 이중강판합성벽은 주기하중에 대하여 핀칭이 없이 우수한 에너지소산능력을 나타냈다. 벽체하단부 기초의 접합상세와 단면형상에 따라 파괴모드 및 변형능력의 차이를 보였으며, 주로 벽체기초 또는 연결보 용접부의 파단과 강판국부좌굴에 의하여 파괴되었다. 적절한 용접 및 보강 상세를 갖는 실험체들은 2.0~3.7% 층간변형각의 변형능력을 보였다. 또한 벽체와 연결보의 비탄성강도를 고려하여 단일벽 및 병렬벽 실험체의 하중재하능력을 평가하였으며, 이를 실험결과와 비교하였다.

Compressive resistance behavior of UHPFRC encased steel composite stub column

  • Huang, Zhenyu;Huang, Xinxiong;Li, Weiwen;Zhang, Jiasheng
    • Steel and Composite Structures
    • /
    • 제37권2호
    • /
    • pp.211-227
    • /
    • 2020
  • To explore the feasibility of eliminating the longitudinal rebars and stirrups by using ultra-high-performance fiber reinforcement concrete (UHPFRC) in concrete encased steel composite stub column, compressive behavior of UHPFRC encased steel stub column has been experimentally investigated. Effect of concrete types (normal strength concrete, high strength concrete and UHPFRC), fiber fractions, and transverse reinforcement ratio on failure mode, ductility behavior and axial compressive resistance of composite columns have been quantified through axial compression tests. The experimental results show that concrete encased composite columns with NSC and HSC exhibit concrete crushing and spalling failure, respectively, while composite columns using UHPFRC exhibit concrete spitting and no concrete spalling is observed after failure. The incorporation of steel fiber as micro reinforcement significantly improves the concrete toughness, restrains the crack propagation and thus avoids the concrete spalling. No evidence of local buckling of rebars or yielding of stirrups has been detected in composite columns using UHPFRC. Steel fibers improve the bond strength between the concrete and, rebars and core shaped steel which contribute to the improvement of confining pressure on concrete. Three prediction models in Eurocode 4, AISC 360 and JGJ 138 and a proposed toughness index (T.I.) are employed to evaluate the compressive resistance and post peak ductility of the composite columns. It is found that all these three models predict close the compressive resistance of UHPFRC encased composite columns with/without the transverse reinforcement. UHPFRC encased composite columns can achieve a comparable level of ductility with the reinforced concrete (RC) columns using normal strength concrete. In terms of compressive resistance behavior, the feasibility of UHPFRC encased steel composite stub columns with lesser longitudinal reinforcement and stirrups has been verified in this study.

Structural behavior of the stiffened double-skin profiled composite walls under compression

  • Qin, Ying;Li, Yong-Wei;Lan, Xu-Zhao;Su, Yu-Sen;Wang, Xiang-Yu;Wu, Yuan-De
    • Steel and Composite Structures
    • /
    • 제31권1호
    • /
    • pp.1-12
    • /
    • 2019
  • Steel-concrete composite walls have been proposed and developed for applications in various types of structures. The double-skin profiled composite walls, as a natural development of composite flooring, provide structural and architectural merits. However, adequate intermediate fasteners between profiled steel plates and concrete core are required to fully mobilize the composite action and to improve the structural behavior of the wall. In this research, two new types of fasteners (i.e., threaded rods and vertical plates) were proposed and three specimens with different fastener types or fastener arrangements were tested under axial compression. The experimental results were evaluated in terms of failure modes, axial load versus axial displacement response, strength index, ductility index, and load-strain relationship. It was found that specimen with symmetrically arranged thread rods sustained more stable axial strain than that with staggered arranged threaded rods. Meanwhile, vertical plates are more suitable for practical use since they provide stronger confinement to profiled steel plate and effectively prevent the steel plate from early local buckling, which eventually enhance the composite action and increase the axial compressive capacity of the wall. The calculation methods were then proposed and good agreement was observed between the test results and the predicted results.

자기복구형 에너지소산 가새시스템을 적용한 종합병원의 내진보강효과 (Seismic Retrofitting Effects of General Hospital Using Self-Centering Energy Dissipative Bracing System)

  • 김태완;추유림;번다리 디워스
    • 한국지진공학회논문집
    • /
    • 제23권3호
    • /
    • pp.159-167
    • /
    • 2019
  • 2016 Gyeongju and 2017 Pohang earthquakes led Koreans to acknowledge that the Korean peninsula is not an earthquake-free zone anymore. Among various buildings crucial to after-shock recovery, general hospital buildings, especially existing old ones, are very significant so seismic retrofitting of those must be an important issue. Self-centering energy dissipative(SCED) brace is one of retrofitting methods, which consists of tendon with restoring force and friction device capable of dissipating seismic energy. The strength of the SCED brace is that the tendon forces a structure to go back to the original position, which means residual drift can be negligible. The residual drift is a very important parameter to determine usableness of general hospitals after shock. To the contrary, buckling-restrained braces(BRB) are also a very effective way to retrofit because they can resist both compressive and tensile, but residual drift may exist when the steel core yields. On this background, the seismic retrofitting effect of general hospitals reinforced with SCED braces was investigated and compared to that of the BRD in this study. As a result, although the floor acceleration cannot be reduced, the story drift and residual drift, and the shear demand of walls significantly decreased. Consequently, seismic retrofitting by SCED braces are very effective for domestic low-rise general hospitals.

A novel prediction model for post-fire elastic modulus of circular recycled aggregate concrete-filled steel tubular stub columns

  • Memarzadeh, Armin;Shahmansouri, Amir Ali;Poologanathan, Keerthan
    • Steel and Composite Structures
    • /
    • 제44권3호
    • /
    • pp.309-324
    • /
    • 2022
  • The post-fire elastic stiffness and performance of concrete-filled steel tube (CFST) columns containing recycled aggregate concrete (RAC) has rarely been addressed, particularly in terms of material properties. This study was conducted with the aim of assessing the modulus of elasticity of recycled aggregate concrete-filled steel tube (RACFST) stub columns following thermal loading. The test data were employed to model and assess the elastic modulus of circular RACFST stub columns subjected to axial loading after exposure to elevated temperatures. The length/diameter ratio of the specimens was less than three to prevent the sensitivity of overall buckling for the stub columns. The gene expression programming (GEP) method was employed for the model development. The GEP model was derived based on a comprehensive experimental database of heated and non-heated RACFST stub columns that have been properly gathered from the open literature. In this study, by using specifications of 149 specimens, the variables were the steel section ratio, applied temperature, yielding strength of steel, compressive strength of plain concrete, and elastic modulus of steel tube and concrete core (RAC). Moreover, parametric and sensitivity analyses were also performed to determine the contribution of different effective parameters to the post-fire elastic modulus. Additionally, comparisons and verification of the effectiveness of the proposed model were made between the values obtained from the GEP model and the formulas proposed by different researchers. Through the analyses and comparisons of the developed model against formulas available in the literature, the acceptable accuracy of the model for predicting the post-fire modulus of elasticity of circular RACFST stub columns was seen.

철근콘크리트 기둥의 휨 연성에 대한 V-타이 보조띠철근의 효율성 평가 (Evaluation on the Effectiveness of Supplementary V-ties on Flexural Ductility of Reinforced Concrete Columns)

  • 이혜진;양근혁;곽민경
    • 콘크리트학회논문집
    • /
    • 제29권4호
    • /
    • pp.345-351
    • /
    • 2017
  • 이 연구에서는 철근콘크리트 기둥의 휨 연성에 대한 보조 띠철근으로서 ACI 318-14에서 제시하는 크로스타이의 대체로서 V-타이 보조 띠철근의 효율성을 평가하였다. 작용 축하중비를 주요 변수로 일정 축하중과 반복 횡하중을 받는 기둥에서 파괴모드 및 횡하중-횡변위 관계를 측정하였다. 기둥의 최대 휨 내력 이후, 크로스타이의 $90^{\circ}$ 갈고리가 서서히 열리면서 주철근의 조기 좌굴 및 코어 콘크리트의 심각한 손상을 동반한 반면, V-타이의 뽑힘 현상은 기둥의 파괴 시까지 나타나지 않았다. 최대 내력의 80% 시점에서 V-타이 기둥의 일손상 지수 값은 크로스타이 기둥에 비해 축력비가 0.25, 0.4 및 0.55일 때 각각 2.4배, 2.3배 및 5.2배 높았다. 즉, 기둥의 휨 연성에 대한 기존 크로스타이 대비 V-타이의 효율성은 축력비가 높을수록 현저하였다.

자가 계측 유도 초음파의 통계적 패턴인식을 이용하는 배관 구조물의 복합 손상 진단 기법 (Multiple Damage Detection of Pipeline Structures Using Statistical Pattern Recognition of Self-sensed Guided Waves)

  • 박승희;김동진;이창길
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권3호
    • /
    • pp.134-141
    • /
    • 2011
  • 최근 사회 기반 시설물에서 구조물의 안전성 및 적정 성능 수준을 확보하기 위하여 구조물의 결함 빛 노후화에 의한 성능 저하 등을 상시적으로 모니터링하기 위한 관심이 높아지고 있다. 이 중 배관 구조물은 국가 주요 자원의 수송을 책임지는 핵심 사회 기반 시설물임에도 불구하고 지중에 매립된다는 위치적 특성 상 상시적으로 구조물의 상태를 모니터링하기는 매우 어렵다. 또한 배관 구조물에서는 내부 미세 균열에서부터 국부 좌굴, 볼트 풀림, 피로 균열 등과 같이 다양한 형태의 손상이 복합적으로 발생 가능하다. 따라서 본 연구에서는 이러한 복합 손상을 효율적으로 진단하기 위하여 압전센서를 이용한 자가 계측 회로 기반의 유도 초음파 계측 시스템을 복합 손상 진단에 적용하였다. 유도 초음파 자가 계측으로부터 특정 중심 주파수에 해당하는 구조물의 웨이블렛 응답을 계측한다. 복합 손상을 유형별로 분류하기 위하여 유도 초음파 계측으로부터 추출한 특성을 이용하여 손상지수를 계산하고 이를 지도학습 기반 패턴인식 기법에 적용한다. 제안된 기법의 적용성 검토를 위하여 배관 구조물에 인위적으로 다중 손상을 생성시켜 시험을 수행하였다.

철근콘크리트 원형기둥의 나선철근 최소철근비에 대한 평가 (Evaluation of Minimum Spiral Reinforcement Ratio of Circular RC Columns)

  • 김영식;김형국;박천범;김상우;김길희
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권6호
    • /
    • pp.1-9
    • /
    • 2017
  • 원형 기둥의 나선철근은 축방향 철근의 위치 고정 및 좌굴방지와 코어콘크리트의 충분한 횡구속으로 기둥의 연성거동에 효과적인 역할을 한다. 각국은 기둥에 요구되는 연성을 확보하기 위하여 나선철근의 최소철근비를 제시하고 있다. ACI 318-14와 국내 콘크리트 구조설계 기준에서 제시하는 나선철근 최소철근비는 Richart et al.(1928)의 이론에 기초하여 개발되었으며 현재까지 사용되고 있다. 그러나 Richart et al.(1928)의 이론은 현대의 고강도 콘크리트, 고강도철근 그리고 나선철근의 배근조건 등의 영향을 고려하지 못한다. 이 연구에서는 나선철근으로 구속된 철근콘크리트 원형 기둥의 내력회복 및 연성증진에 요구되는 나선철근에 대한 수정 최소철근비 산정식을 제시한다. 수정 최소철근비 산정식은 콘크리트 압축강도, 나선철근 항복강도, 기둥의 단면적, 나선철근 배근간격, 나선철근 직경의 영향을 고려하고 있다. 이 논문에서는 재료강도 및 나선철근 최적비를 변수로 한 실험체의 일축 압축실험을 통하여 ACI 318-14에 제시하는 나선철근 최소철근비 산정식의 타당성을 검토하고, 그 결과를 토대로 나선철근 최소철근비 산정식의 수정방안을 고찰하였다.

확대단면에서의 띠철근 배근 방법에 따른 보강 기둥의 중심 축하중 거동 평가 (Evaluation of Axial Behavior of Columns Strengthened with Different Transverse Reinforcements in Jacket Section)

  • 황용하;양근혁;심재일;최용수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권6호
    • /
    • pp.81-88
    • /
    • 2018
  • 이 연구에서는 실제 단면크기를 갖는 철근 콘크리트 기둥의 내진보강을 위한 단면확대 공법에서 효율적인 띠철근 배근 방법을 평가하였다. 비내진 상세를 갖는 기존 기둥의 단면크기는 $450{\times}450mm$이며, 단면확대 보강기둥의 단면크기는 $750{\times}750mm$이다. 확대 단면에서의 폐쇄형 외부 띠철근 배근을 위해 ㄷ-형 띠철근의 겹칩이음 및 철근 선조립 공법을 제시하였으며, 보조 띠철근으로서 크로스타이 앵커링 시공 및 V-타이를 고려하였다. 실험 결과, 무보강 기둥 및 ㄷ-형 외부 띠철근을 적용한 보강기둥의 압축내력은 ACI 318-14의 공칭내력과 비슷한 수준인 반면 철근 선조립 공법을 적용한 기둥의 압축내력은 ACI 318-14의 공칭내력 대비 1.25배 높았다. 특히 철근 선조립 공법을 적용한 보강 기둥의 압축 연성비는 크기효과에 의한 연성비 저하 가능성에도 불구하고 기존 기둥에 비해 139% 증가하였다. 즉, 제시된 철근 선조립 공법은 단면확대 보강기둥에서 주철근 조기 좌굴방지 및 콘크리트 구속에 효율적인 띠철근 상세로 평가될 수 있었다.