• 제목/요약/키워드: cooling COP

검색결과 369건 처리시간 0.028초

부하변화에 따른 hot-gas 바이패스 방식별 성능 비교 (Performance Comparison of Hot-gas Bypass Types with the Variation of Refrigeration Load)

  • 백승문;윤정인;손창효;허정호
    • 동력기계공학회지
    • /
    • 제18권5호
    • /
    • pp.48-54
    • /
    • 2014
  • In this paper, three refrigeration systems bypassing hot-gas to compressor outlet, compressor and condenser outlet and evaporator inlet are theoretically compared to offer basic design data for performance depending on cooling load using a HYSYS program. The main results are summarized as follows : First, the COP of third system is the highest. Next, the COP of second system is higher than first one. And, the temperature of compressor inlet of third system is constant for all cooling load. Compared to first and second system, the compressor inlet temperature of the first system is higher than second one for all cooling loads. From the above results, third system, which is bypassing hot-gas to evaporator inlet, is more advantageous when considering the precise temperature control and excellent performance of oil and water cooler of industrial machine.

내부 열교환기 부착 $CO_2-C_3H_8$용 캐스케이드 냉동시스템의 성능 특성 (Performance Characteristics of a Cascade Refrigeration System with Internal Heat Exchanger using Carbon Dioxide (R744) and Propane (R290))

  • 손창효
    • 한국수소및신에너지학회논문집
    • /
    • 제20권6호
    • /
    • pp.526-533
    • /
    • 2009
  • In this paper, cycle performance analysis of $CO_2-C_3H_8$ (R744-R290) cascade refrigeration system with internal heat exchanger is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooling and superheating degree and gas cooling pressure and evaporating temperature in the propane (R290) low temperature cycle and the carbon dioxide (R744) high temperature cycle. The main results were summarized as follows : The COP of cascade refrigeration system of $CO_2-C_3H_8$ (R744-R290) increases with the increasing subcooling degree, but decreases with the increasing superheating degree. The COP of cascade refrigeration system increases with the increasing evaporating temperature, but decreases with the increasing gas cooling pressure. Therefore, superheating and subcooling degree, compressor efficiency, evaporating temperature and gas cooling pressure of $CO_2-C_3H_8$ (R744-R290) cascade refrigeration system have an effect on the COP of this system.

HFC32 냉매를 사용한 지열원 히트펌프의 성능 특성 (Performance of the Geothermal Heat Pump Using HFC32 Refrigerant)

  • 박용정;박병덕
    • 한국수소및신에너지학회논문집
    • /
    • 제30권4호
    • /
    • pp.369-375
    • /
    • 2019
  • Air conditioners adopting high energy efficiency and low global warming potential (GWP) refrigerant are being developed globally. In case of commercial air conditioner, R32 with lower GWP than R410A is attracting industrial attentions. In this study, the performance of water-to-water geothermal heat pump adopting R32 is compared with that of the heat pump using R410A. By using R32 instead of R410A, heating capacity and COP in heating standard condition can be increased by 8.8% and 6.3% respectively. Also, cooling capacity and COP in cooling standard condition can be increased by 5.3% and 3.1% respectively by using R32. But in case of using R32, systemic improvements are required to decrease discharge temperature of compressor since discharge temperature rises abnormally in heating operations.

자연냉매인 CO2를 이용한 냉동탑차 냉장시스템과 핵심부품개발에 관한 연구 (A Study of Development of Regrigerated Truck Small Scale Cooling System and Key-Part using Natural Refrigerants.)

  • 정세진;박성신;민호기;조가영
    • 한국가스학회지
    • /
    • 제23권1호
    • /
    • pp.19-26
    • /
    • 2019
  • 본 연구에서는 친환경적 냉매로 주목받고 있는 이산화탄소 자연 냉매를 이용하여 1톤 크기의 냉동 탑차에 들어가는 냉방 시스템을 개발하고, COP를 올리기 위해 열교환기 및 Unit cooler를 설계하였다. 또한 LNG의 기존 CNG 5톤 냉동탑차를 LNG 차량으로 개조하여 냉방시스템의 효율을 높임과 동시에 CNG 대비 안전성을 확보하였다. 결과적으로 1톤 및 5톤 크기에서 자연 냉매를 사용한 친환경적인 냉동탑차를 개발하였다.

용량가변 방식을 적용한 압축기의 성능연구 (Performance of Compressor with Variable Capacity)

  • 권영철;진의선;허삼행;김대훈;홍주태;문제명
    • 에너지공학
    • /
    • 제13권3호
    • /
    • pp.214-218
    • /
    • 2004
  • 본 연구에서는 용량가변방식을 적용한 PWM 압축기의 냉방운전 시 소비전력 변화 및 성능향상을 조사하기 위해서 기존 및 개선된 압축기의 능력, 소비전력, COP를 측정하여 비교하였다. 압축기의 효율 향상을 위해 무부하 상태에서 압축기 운전콘덴서의 변경, 복수구동부의 교차운전, 그리고 주 전류단에 코일를 적용하여 소비전력의 변화를 측정하였다. 용량가변형인 PWM압축기는 압축기 능력이 증가함에 따라 소비전력과 COP가 선형적으로 증가하였다. 압축기의 운전 콘덴서를 바꾸어가면서 소비전력을 측정한 경우 소비전력의 최적점이 확인되었다. 한편, 복수 구동부의 적용으로 불필요한 과전압에 의한 소비전력을 감소할 수 있었다.

사무용건물에서 지열히트펌프냉난방시스템의 운전성능 평가 (Performance for Geothermal Heating & Cooling System by Heatpump in Office Building)

  • 안형준;백성권;조정식;손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제3권1호
    • /
    • pp.23-29
    • /
    • 2007
  • For the perfomance test of geothermal system, a large pilot of capacity of 50RT is built and operated in office building. This system is planed hybrid system with cooling tower as asisstance heat sink. From October, 2004 to September, 2005, this system is operated andmonitored. As the result, COP of heating periods is about 3.46 and COP of cooling periods is about 4.1. Therefore, geothermal system is useful and suitable in Korea.

  • PDF

3실형 인버터 열펌프 시스템의 냉방성능 측정 (Cooling Performance Measurement of a 3 Room Type Inverter Heat Pump System)

  • 정광진;최영돈;장효환;송재복;박윤철
    • 설비공학논문집
    • /
    • 제13권6호
    • /
    • pp.431-439
    • /
    • 2001
  • Recently, multi-room type heat pump system has aroused much attention, because it can achieve much reduction of installation cost and space as well as energy saving in companion with the single room type heat pump system. In the present study, performance characteristics of a 3 room type inverter driven heat pump system, which is widely spread in Japanese market, are measured.. In the single room operation, performances of a heat pump system such s the difference of compressor outlet and inlet pressures and the mass flowrate may increase with the increase of cooling capacity so that COP of the system decrease with the increase of cooling capacity. However, in the 2 room operation, mass flowrate and COP of the total system increase markedly as compared with the single room operation.

  • PDF

지열히트펌프 시스템의 EWT의 변화에 따른 냉방운전 특성에 관한 실험적 연구 (An Experimental Study on the Cooling Operation Characteristics for Different Entering Water Temperatures In Geothermal Heat Pump System)

  • 안병천;김재완
    • 한국지열·수열에너지학회논문집
    • /
    • 제6권1호
    • /
    • pp.1-7
    • /
    • 2010
  • In this paper, an experimental study on the cooling operation characteristics for different entering water temperatures in geothermal heat pump system are carried out by using Lab VIEW system program Set-point temperature controls for cooling water and supply air temperatures is applied to analyze the energy consumption and control performances. As a result, the system responses show that different entering water temperatures(EWT) effect greatly on the energy consumption and system COP.

ATES 열펌프 시스템 성능 및 경제성 분석에 관한 연구 (Study on the Performance of an ATES Geothermal Heat Pump System and Economic Analysis)

  • 오명석;최종민
    • 설비공학논문집
    • /
    • 제24권4호
    • /
    • pp.289-296
    • /
    • 2012
  • The aim of this study is to investigate the performance of a heating and cooling system with aquifer thermal energy storage(ATES heat pump system) known as one of the underground thermal energy storage application systems. The ATES system was composed of heat pump unit and ATES, which was installed in a factory building located in Anseoung. The system represented very high heating and cooling performance, and showed nearly constant COP at each heating and cooling season due to the stability of EWT. The economic analysis about an ATES system and a conventional system was also executed. The conventional system adopted an air-conditioner in the summer season and a LNG boiler in the winter season. The payback period of the ATES system was estimated by 6.62 years.

실내온도조절을 위한 인버터 열펌프의 주파수 제어에 관한 연구 (A study of frequency control of an inverter heat pump for indoor air temperature adjustment)

  • 박윤철;민만기
    • 대한기계학회논문집B
    • /
    • 제21권10호
    • /
    • pp.1262-1272
    • /
    • 1997
  • An experimental study on the frequency control of an inverter heat pump to get the desired indoor room temperature has been conducted for the performance characteristics during the steady, 4, 8, and 16 step frequency operations. The heat pump model used in this study was operated to meet the experimental conditions of ASHRAE standard. The performance of the system was tested by measuring the temperature and pressure of the refrigerant, and cooling capacity, power consumption, etc. of the system. As the controlling frequency steps increased, the running time of the compressor increased as well as the electric consumption of the system and the cooling energy due to the wall heating load. However, the average cooling COP was improved.