• 제목/요약/키워드: conversion system

검색결과 3,578건 처리시간 0.033초

Passive 트랜스폰더에서의 전력변환 효율 향상을 위한 연구 (Improving power conversion efficiency of the passive transponder)

  • 김광수;이교성;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.1951-1953
    • /
    • 1998
  • In this study, we present the power conversion system of the passive transponder which is operated at 2.4GHz. First, The passive transponder which is the power conversion system is one of the passive transponder elements is presented. And then the power conversion system is analyzed and simulated.

  • PDF

강체전차선로의 특성을 고려한 급전시스템에서 이선에 따른 철도차량 전력변환장치에 대한 특성에 관한 연구 (A Study on Characteristic of Power Conversion System in Electric Railway Vehicle According to Contact Loss in Feeding System Considering Characteristic of Rigid Bar)

  • 정노건;이환;김재문
    • 전기학회논문지
    • /
    • 제65권3호
    • /
    • pp.520-525
    • /
    • 2016
  • In this paper, Characteristic of power conversion unit of a railway vehicles according to contact loss in feeding system that applied impedance of rigid conductor is analyzed. It applied impedance of rigid bar in modeling of electric railway system. Railway vehicles are performed of modeling based on the performance of the electric railway vehicle. Effects of the contact loss in the power conversion unit were analyzed via main transformer of railway vehicle, the input and output voltage characteristics of the converter through contact loss was generated after linking the vehicle with feeding system.

영전압 스위칭 복합 공진형 변환 시스템에 대한 민감도 해석 (Sensitivity Analyssi on Zero Voltage Switching Multi-Resonant conversion System)

  • Hyun, Dong-Seok
    • 대한전기학회논문지
    • /
    • 제40권7호
    • /
    • pp.664-669
    • /
    • 1991
  • In order to improve the reliability and the stability of static power conversion system, further to optimize the operational characteristics of the system, it is very important to investigate the effects (output and switching component characteristics) of each parameters in the system. Therefore this paper particualrly deals with the characteristics of a novel ZVS multi-resonant conversion system to duty cycle, resonant capacitance, resonant inductance, and output capacitance. The results show that resonant inductance and output capacitance are dominat factors in the system.

두 종류의 부하곡선에 관한 공급지장시간기대치(LOLE)의 상호 변환관계성 (Conversion Function and Relationship of Loss of Load Expectation Indices on Two Kinds of Load Duration Curve)

  • 이연찬;오웅진;최재석;차준민;최홍석;전동훈
    • 전기학회논문지
    • /
    • 제66권3호
    • /
    • pp.475-485
    • /
    • 2017
  • This paper develops a conversion function and method transforming from daily peak load curve used $LOLE_D$ [days/year] to hourly load curve used $LOLE_H$[hours/year]and describes relationship between $LOLE_D$ [days/year] and $LOLE_H$ [hours/year]. The indices can not only be transformed just arithmetically but also have different characteristics physically because of using their different load curves. The conversion function is formulated as variables of capacity and forced outage rate of generator, hourly load daily load factor and daily peak load yearly load factor, etc. Therefore, the conversion function (${\gamma}={\varphi}$(.)) can not be simple. In this study, therefore, the function is formulated as linear times of separated two functions. One is an exponential formed conversion function of daily load factor. Another is formulated with an exponential typed conversion function of daily peak load yearly load factor. Futhermore, this paper presents algorithm and flow chart for transforming from $LOLE_D$[days/year] to $LOLE_H$[hours/year]. The proposed conversion function is applied to sample system and actual KPS(Korea Power System) in 2015. The exponent coefficients of the conversion functions are assessed using proposed method. Finally, assessment errors using conversion function for case studies of sample system and actual system are evaluated to certify the firstly proposed method.

에너지변환을 이용한 피부의 투과조절에 관한 연구 (A Study of energy conversion by the penetration control in the skin)

  • 김정래;김혜주
    • 문화기술의 융합
    • /
    • 제3권1호
    • /
    • pp.43-48
    • /
    • 2017
  • 본 연구는 에너지 변환을 가하면 피부에 기능별 투과와 전달현상의 변화를 확인한다. 주어진 에너지의 변화로 피부에 진행되는 과정과 에너지 전달에 투과조절의 단계로 흐르는 과정을 구성하고, 알고리즘을 통하여 변화의 과정을 모델링한다. 에너지양의 조절과 과정의 처리를 모델링한 상태에서 피부의 표피 진피에 효과적 단계로 자동 조절 및 국부 조절을 통한 시스템 모델을 구성하였다. 에너지 변환에 따른 고정된 위치와 계획된 장치로 재현하는 에너지 조절기능이 크기 형태 조합을 변환시키는 모형으로인한 깊이에 따른 분포의 변화가 정확하게 얻어지도록 투과펄스시스템을 구성하였다. 따라서 효율적인 에너지 변환을 제어하는 전달시스템을 구성하기위해 변환모델을 세분화하여 구축하였다. 이를 통하여 피부효과에 기능적 에너지 조절이 가능한 투과 조절시스템이 구성되어 지속적인 피부의 개선효과가 진행 될 것으로 예상된다.

Comparative Study on 220V AC Feed System and 300V DC Feed System for Internet Data Centers

  • Kim, Hyo-Sung
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.157-163
    • /
    • 2012
  • Internet Data Centers (IDCs), which are essential facilities in the modern IT industry, typically have scores of MW of concentrated electric loads. The provision of an Uninterruptible Power Supply (UPS) is necessary for the power feed system of IDCs owing to the need for stable power. Thus, conventional IDC AC power feed systems have three cascaded power conversion stages, (AC-DC), (DC-AC), and (AC-DC), resulting in a very low conversion efficiency. In comparison, DC power feed systems require only a single power conversion stage (AC-DC) to supply AC main power to DC server loads, resulting in comparatively high conversion efficiency and reliability [4-11]. This paper compares the efficiencies of a 220V AC power feed system with those of a 300V DC power feed system under equal load conditions, as established by the Mok-Dong IDC of Korea Telecom Co. Ltd. (KT). Experimental results show that the total operation efficiency of the 300V DC power feed system is approximately 15% higher than that of the 220V AC power feed system.

고압 대전류용 전력변환 점호장치 및 감시시스템 개발 (Development of firing equipment and monitoring system for electric power conversion system for high voltage and large current)

  • 이주현;임익헌;류호선
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.481-484
    • /
    • 2006
  • A electric power conversion system in a pumped storage power plant is important equipment for converting electric motor kinetic energy into electric power. A electric power conversion monitoring system consists of high voltage thyristor firing equipment, fault detection module, data gathering module, real time data processing equipment and man machine interface system. This paper describes electric power conversion system overview, the developed SFC monitoring system configuration including system characteristics, and successful application result to San-Cheong pumped storage power plant.

  • PDF

음성처리를 위한 표준 발음법의 전산화 (Computerization and Application of Hangeul Standard Pronunciation Rule)

  • 이계영
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 Ⅲ
    • /
    • pp.1363-1366
    • /
    • 2003
  • This paper introduces computerized version of Hangout(Korean Language) Standard Pronunciation Rule that can be used in Korean processing systems such as Korean voice synthesis system and Korean voice recognition system. For this purpose, we build Petri net models for each items of the Standard Pronunciation Rule, and then integrate them into the vocal sound conversion table. The reversion of Hangul Standard Pronunciation Rule regulates the way of matching vocal sounds into grammatically correct written characters. This paper presents not only the vocal sound conversion table but also character conversion table obtained by reversely converting the vocal sound conversion table. Making use of these tables, we have implemented a Hangeul character into a vocal sound system and a Korean vocal sound into character conversion system, and tested them with various data sets reflecting all the items of the Standard Pronunciation Rule to verify the soundness and completeness of our tables. The test results shows that the tables improves the process speed in addition to the soundness and completeness.

  • PDF

Optimal Design of a Direct-Drive Permanent Magnet Synchronous Generator for Small-Scale Wind Energy Conversion Systems

  • Abbasian, Mohammadali;Isfahani, Arash Hassanpour
    • Journal of Magnetics
    • /
    • 제16권4호
    • /
    • pp.379-385
    • /
    • 2011
  • This paper presents an optimal design of a direct-drive permanent magnet synchronous generator for a small-scale wind energy conversion system. An analytical model of a small-scale grid-connected wind energy conversion system is presented, and the effects of generator design parameters on the payback period of the system are investigated. An optimization procedure based on genetic algorithm method is then employed to optimize four design parameters of the generator for use in a region with relatively low wind-speed. The aim of optimization is minimizing the payback period of the initial investment on wind energy conversion systems for residential applications. This makes the use of these systems more economical and appealing. Finite element method is employed to evaluate the performance of the optimized generator. The results obtained from finite element analysis are close to those achieved by analytical model.

산지전용허가 의사결정지원시스템의 실제 운용가능성에 관한 연구 (A Study on the Applicability of Decision Support System for the Permission of Forest Land-Use Conversion)

  • 최상현;김은진;남주희;우종춘
    • Journal of Forest and Environmental Science
    • /
    • 제30권1호
    • /
    • pp.45-49
    • /
    • 2014
  • This study was tried to find out the applicability of decision support system for forest land use conversion, which developed based on algorithm for forest land-use conversion. Decision support system developed by Ministry of Safety Administration is free from the existing licensed laws omission. And it made the input requirements for each value of the final result so that you can determine whether the permit was available by the laws and regulations related to the algorithm for forest land use conversion. Also, in order to do field surveys, equal sampling interval method is used to extract samples for the operability by comparing and analyzing the actual area. As a result, 88 areas of total 100 areas are able to get permission by the decision support system for forest land use conversion, and it means if there is enough data with sufficient research, it can make the availability permits easily.