• Title/Summary/Keyword: conventional-PCR

Search Result 326, Processing Time 0.032 seconds

Specific and Sensitive Detection of Phoma glomerata Using PCR Techniques (PCR 기법을 이용한 Phoma glomerate 의 특이검출)

  • Yun, Yeo Hong;Suh, Dong Yeon;Kim, Hyun Ju;Kim, Seong Hwan
    • The Korean Journal of Mycology
    • /
    • v.41 no.1
    • /
    • pp.52-55
    • /
    • 2013
  • Phoma glomerata (Corda) Wollenw. & Hochapfel is a pathogenic fungus causing spot diseases of plant leaves and fruits. This fungus is important in plant quarantine of seedlings and fruits in Korea. The aim of this study was to develop a sensitive and effective diagnostic method for P. glomerata detection in imported plants. The fungal species-specific PCR primers were designed based on the nucleotide sequences of the translation elongation factor 1 alpha gene and their specificity and sensitivity were tested. The designed primers named as PhoGlo-F and PhoGlo-R amplified specifically a 170 bp sized DNA band of the target gene from the genomic DNA of P. glomerata. No amplicon was produced from genomic DNAs of 16 other Phoma spp. and reference fungal species tested. Moreover, PhoGlo-F/PhoGlo-R primers successfully worked with real-time PCR technique. The detection limit of DNA content by conventional and real-time PCR were 10 pg and 1pg of the genomic DNA of P. glomerata, respectively. We believed that the developed makers would be very useful for P. glomerata detection.

Internal Amplification Control for a Cryptosporidium Diagnostic PCR: Construction and Clinical Evaluation

  • Hawash, Yousry;Ghonaim, M.M.;Al-Hazmi, Ayman S.
    • Parasites, Hosts and Diseases
    • /
    • v.53 no.2
    • /
    • pp.147-154
    • /
    • 2015
  • Various constituents in clinical specimens, particularly feces, can inhibit the PCR assay and lead to false-negative results. To ensure that negative results of a diagnostic PCR assay are true, it should be properly monitored by an inhibition control. In this study, a cloning vector harboring a modified target DNA sequence (${\approx}375bp$) was constructed to be used as a competitive internal amplification control (IAC) for a conventional PCR assay that detects ${\approx}550bp$ of the Cryptosporidium oocyst wall protein (COWP) gene sequence in human feces. Modification of the native PCR target was carried out using a new approach comprising inverse PCR and restriction digestion techniques. IAC was included in the assay, with the estimated optimum concentration of 1 fg per reaction, as duplex PCR. When applied on fecal samples spiked with variable oocysts counts, ${\approx}2$ oocysts were theoretically enough for detection. When applied on 25 Cryptosporidium-positive fecal samples of various infection intensities, both targets were clearly detected with minimal competition noticed in 2-3 samples. Importantly, both the analytical and the diagnostic sensitivities of the PCR assay were not altered with integration of IAC into the reactions. When tried on 180 randomly collected fecal samples, 159 were Cryptosporidium-negatives. Although the native target DNA was absent, the IAC amplicon was obviously detected on gel of all the Cryptosporidium-negative samples. These results imply that running of the diagnostic PCR, inspired with the previously developed DNA extraction protocol and the constructed IAC, represents a useful tool for Cryptosporidium detection in human feces.

Prevalence of feline calicivirus in Korean cats determined by an improved real-time RT-PCR assay

  • Ji-Su Baek;Jong-Min Kim;Hye-Ryung Kim;Yeun-Kyung Shin;Oh-Kyu Kwon;Hae-Eun Kang;Choi-Kyu Park
    • Korean Journal of Veterinary Service
    • /
    • v.46 no.2
    • /
    • pp.123-135
    • /
    • 2023
  • Feline calicivirus (FCV) is considered the main viral pathogen of feline upper respiratory tract disease (URTD). The frequent mutations of field FCV strains result in the poor diagnostic sensitivity of previously developed molecular diagnostic assays. In this study, a more sensitive real-time reverse transcription-polymerase chain reaction (qRT-PCR) assay was developed for broad detection of currently circulating FCVs and comparatively evaluated the diagnostic performance with previously developed qRT-PCR assay using clinical samples collected from Korean cat populations. The developed qRT-PCR assay specifically amplified the FCV p30 gene with a detection limit of below 10 copies/reaction. The assay showed high repeatability and reproducibility, with coefficients of intra-assay and inter-assay variation of less than 2%. Based on the clinical evaluation using 94 clinical samples obtained from URTD-suspected cats, the detection rate of FCV by the developed qRT-PCR assay was 47.9%, which was higher than that of the previous qRT-PCR assay (43.6%). The prevalence of FCV determined by the new qRT-PCR assay in this study was much higher than those of previous Korean studies determined by conventional RT-PCR assays. Due to the high sensitivity, specificity, and accuracy, the new qRT-PCR assay developed in this study will serve as a promising tool for etiological and epidemiological studies of FCV circulating in Korea. Furthermore, the prevalence data obtained in this study will contribute to expanding knowledge about the epidemiology of FCV in Korea.

Validation of QF-PCR for Rapid Prenatal Diagnosis of Common Chromosomal Aneuploidies in Korea

  • Han, Sung-Hee;Ryu, Jae-Song;An, Jeong-Wook;Park, Ok-Kyoung;Yoon, Hye-Ryoung;Yang, Young-Ho;Lee, Kyoung-Ryul
    • Journal of Genetic Medicine
    • /
    • v.7 no.1
    • /
    • pp.59-66
    • /
    • 2010
  • Purpose: Quantitative fluorescent polymerase chain reaction (QF-PCR) allows for the rapid prenatal diagnosis of common aneuploidies. The main advantages of this assay are its low cost, speed, and automation, allowing for large-scale application. However, despite these advantages, it is not a routine method for prenatal aneuploidy screening in Korea. Our objective in the present study was to validate the performance of QF-PCR using short tandem repeat (STR) markers in a Korean population as a means for rapid prenatal diagnosis. Material and Methods: A QF-PCR assay using an Elucigene kit (Gen-Probe, Abingdon, UK), containing 20 STR markers located on chromosomes 13, 18, 21, X and Y, was performed on 847 amniotic fluid (AF) samples for prenatal aneuploidy screening referred for prenatal aneuploidy screening from 2007 to 2009. The results were then compared to those obtained using conventional cytogenetic analysis. To evaluate the informativity of STR markers, the heterozygosity index of each marker was determined in all the samples. Results: Three autosomes (13, 18, and 21) and X and Y chromosome aneuploidies were detected in 19 cases (2.2%, 19/847) after QF-PCR analysis of the 847 AF samples. Their results are identical to those of conventional cytogenetic analysis, with 100% positive predictive value. However, after cytogenetic analysis, 7 cases (0.8%, 7/847) were found to have 5 balanced and 2 unbalanced chromosomal abnormalities that were not detected by QF-PCR. The STR markers had a slightly low heterozygosity index (average: 0.76) compared to those reported in Caucasians (average: 0.80). Submicroscopic duplication of D13S634 marker, which might be a unique finding in Koreans, was detected in 1.4% (12/847) of the samples in the present study. Conclusion: A QF-PCR assay for prenatal aneuploidy screening was validated in our institution and proved to be efficient and reliable. However, we suggest that each laboratory must perform an independent validation test for each STR marker in order to develop interpretation guidelines of the results and must integrate QF-PCR into the routine cytogenetic laboratory workflow.

A Simple, Single Triplex PCR of IS6110, IS1081, and 23S Ribosomal DNA Targets, Developed for Rapid Detection and Discrimination of Mycobacterium from Clinical Samples

  • Nghiem, Minh Ngoc;Nguyen, Bac Van;Nguyen, Son Thai;Vo, Thuy Thi Bich;Nong, Hai Van
    • Journal of Microbiology and Biotechnology
    • /
    • v.25 no.5
    • /
    • pp.745-752
    • /
    • 2015
  • Tuberculosis (TB) is the most common mycobacterial infection in developing countries, requiring a rapid, accurate, and well-differentiated detection/diagnosis. For the rapid detection and discrimination of Mycobacterium tuberculosis complex (MTC) from non-tuberculous mycobacteria (NTM), a novel, simple, and primer-combined single-step multiplex PCR using three primer pairs (6110F-6110R, 1081F-1081R, and 23SF-23SR; annealing on each of IS6110, IS1081, and 23S rDNA targets), hereafter referred to as a triplex PCR, has been developed and evaluated. The expected product for IS6110 is 416 bp, for IS1081 is 300 bp, and for 23S rDNA is 206 bp by single PCR, which was used to verify the specificity of primers and the identity of MTC using DNA extracted from the M. tuberculosis H37Rv reference strain (ATCC, USA) and other mycobacteria other than tuberculosis (MOTT) templates. The triplex PCR assay showed 100% specificity and 96% sensitivity; the limit of detection for mycobacteria was ~100 fg; and it failed to amplify any target from DNA of MOTT (50 samples tested). Of 307 blinded clinical samples, overall 205 positive M. tuberculosis samples were detected by single PCR, 142 by conventional culture, and 90 by AFB smear methods. Remarkably, the triplex PCR could subsequently detect 55 positive M. tuberculosis from 165 culture-negative and 115 from 217 AFB smear-negative samples. The triplex PCR, targeting three regions in the M. tuberculosis genome, has proved to be an efficient tool for increasing positive detection/discrimination of this bacterium from clinical samples.

A New and Rapid Testing Method for Drug Susceptibility of Mycobacterium leprae Using RT-PCR

  • Kim, Min-Joo;Lee, Ju-Hang;You, Ji-Chang
    • Journal of Microbiology and Biotechnology
    • /
    • v.10 no.5
    • /
    • pp.685-689
    • /
    • 2000
  • Due to the uncultivable nature of Mycobacterium leprae in vitro, the fast, easy, and accurate measurement of the antimicrobial drug susceptibility of this microbe has been difficult. Conventional methods for such testing are subjective, cumbersome, and expensive in some cases. Here, the utility of a reverse transcriptase-PCR (RT-PCR)-based assay for testing was examined and compared with a Buddmeyer-type radiorespirometric assay. The susceptibility of M. leprae to rifampin was determined by probing the presence of M.leprae-specific 18 kDa gene mRNA in M. leprae-infected IC-21 macrophage cells after drug treatment. The results showed that, as the refampin concentration was increased, the 360-bp cDNA products generated by the RT-PCR-based assay decreased in a dose-dependent manner as in the drug susceptibility observed in the Buddmeyer-type assay. The drug susceptibility testing of M. leprae by the RT-PCR based assay was found to be not only faster but also nearly $10^4$-fold more sensitive than the Buddmeyer-type assay. Moreover, it was also found that, unlike the RT-PCR based assay, the same testing by a DNA-PCR resulted in no differences in the 360-bp signal, regardless of the rifampin concentrations used. Accordingly, these results demonstrated that the drug susceptibility of M. leprae can be determined effectively by an RT-PCR-based assay, thereby providing a new, fast, and sensitive testing method.

  • PDF

Detection of Methicillin Resistance in Staphylococcus aureus Isolates Using Two-Step Triplex PCR and Conventional Methods

  • Cho, Joon-Il;Jung, Hye-Jin;Kim, Young-Joon;Park, Sung-Hee;Ha, Sang-Do;Kim, Keun-Sung
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.4
    • /
    • pp.673-676
    • /
    • 2007
  • A two-step triplex PCR assay targeting the mecA, femA, and nuc genes was developed for the detection of methicillin resistance genes harbored by some Staphylococcus aureus isolates and for the simultaneous identification of such isolates at the species level. The triplex PCR revealed the presence of the femA and nuc genes in all the S. aureus isolates examined (n=105). Forty-four clinical isolates were mecA positive and no foodborne isolates were mecA positive. The PCR results had a 98 or 99% correlation with the results of PBP2a latex agglutination tests or oxacillin susceptibility tests, respectively.

Current status on the development of detection methods for genetically modified plants (유전자변형식물의 검정기술 개발 현황)

  • Kim, Jae-Hwan;Kim, Young-Rok;Kim, Hae-Yeong
    • Journal of Plant Biotechnology
    • /
    • v.38 no.2
    • /
    • pp.143-150
    • /
    • 2011
  • Since the first commercial GM plant, the FlavrSavr tomato, authorized in 1994, more than 140 GM plants were authorized for marketing globally. For the authorization and labelling of GM plants, the detection methods for genes introduced and proteins expressed in GM plants were developed qualitatively and quantitatively. This review presented the detection methods, conventional PCR, multiplex PCR and real-time PCR, for soybean, maize, canola and cotton as the dominant GM plants. Also, microarray assay and nanotechnology as new approaches for detection methods for GM plants were investigated.

Rapid Detection of Serum HCV RNA by Combining Reverse Transcription and PCR without RNA Extraction

  • Jang, Jeong-Su;Lee, Kong-Joo
    • Archives of Pharmacal Research
    • /
    • v.19 no.6
    • /
    • pp.486-489
    • /
    • 1996
  • A simple, rapid, specific and sensitive method for the detection of serum hepatitis C virus (HCV) RNA using the reverse transcription-polymerase chain reaction (RT-PCR) technique without conventional RNA extraction was developed. HCV template RNA from serum was obtained by boiling the serum at $95^{\circ}C$ for 2 min, cooling rapidly in ice and removing the proteins by cetrifugation. RT-PCR amplifications including the reverse transcription and first PCR amplification were performed in one vessel containing both of reverse transcriptase and Taq DNA polymerase. The detection of HCV RNA from $10^{-3}{\mu}l$. serum was possible with this method. The suitability of this method for clinical analysis was evaluated by assaying HCV RNA in 225 patient samples including anti-HCV antibody negatives (13 samples) and positives (212 samples) by enzyme-linked immunosorbent assay test (ELISA). Detections of HCV RNA with this method were in 4 of 13 anti-HCV antibody negative samples (30.8%) and 95 of 212 positive samples (44.8%). The present method can be completed in 1 hr and has a wide range of application for the clinical utilities to determine the viral RNAS.

  • PDF

SoEM: a novel PCR-free biodiversity assessment method based on small-organelles enriched metagenomics

  • Jo, Jihoon;Lee, Hyun-Gwan;Kim, Kwang Young;Park, Chungoo
    • ALGAE
    • /
    • v.34 no.1
    • /
    • pp.57-70
    • /
    • 2019
  • DNA metabarcoding is currently used for large-scale taxonomic identification to understand the community composition in various marine ecosystems. However, before being widely used in this emerging field, this experimental and analytic approach still has several technical challenges to overcome, such as polymerase chain reaction (PCR) bias, and lack of well-established metabarcoding markers, a task which is difficult but not impossible to achieve. In this study, we present an adapted PCR-free small-organelles enriched metagenomics (SoEM) method for marine biodiversity assessment. To avoid PCR bias and random artefacts, we extracted target DNA sequences without PCR amplification from marine environmental samples enriched with small organelles including mitochondria and plastids because their genome sequences provide a valuable source of molecular markers for phylogenetic analysis. To experimentally enrich small organelles, we performed subcellular fractionation using modified differential centrifugation for marine environmental DNA samples. To validate our SoEM method, two marine environmental samples from the coastal waters were tested the taxonomic capturing capacity against that of traditional DNA metabarcoding method. Results showed that, regardless of taxonomic levels, at least 3-fold greater numbers of taxa were identified in our SoEM method, compared to those identified by the conventional multi-locus DNA metabarcoding method. The SoEM method is thus effective and accurate for identifying taxonomic diversity and presents a useful alternative approach for evaluating biodiversity in the marine environment.