• Title/Summary/Keyword: control threshold

Search Result 1,145, Processing Time 0.028 seconds

A Study on the Swallowing Threshold of the Patients with Bilateral Missing of Molars (양측 대구치 상실환자의 연하역치에 관한 연구)

  • Yang, Jae-Ho
    • The Journal of the Korean dental association
    • /
    • v.11 no.1
    • /
    • pp.53-57
    • /
    • 1973
  • The swallowing threshold of 40 subjects with bilateral missing of molars was tested. The results were as follows : 1) The swallowing threshold of the patients with bilateral missing of molars was higher than that of the normal control subjects. 2) The swallowing threshold of the patients with bilateral missing of molars was higher than that of the full denture wearer. 3) The swallowing threshold of the patients with bilateral missing of molars was different according to the quality and quantity of the test food.

  • PDF

Noise Cancelling Automatic Threshold Control Method for Radar Signal Detection (레이더 신호 탐지를 위한 잡음제거 임계레벨 자동제어 기법)

  • Lee, Chi-Hun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.214-217
    • /
    • 2013
  • In this paper, we proposed an automatic threshold control method for radar warning receiver. Considering the noise level of the environment, this technique can effectively adjust sensitivity level of radar warning receiver and can offer more accurate radar information for aircraft pilot in noisy circumstances.

An Adaptive Moving Average (A-MA) Control Chart with Variable Sampling Intervals (VSI) (가변 샘플링 간격(VSI)을 갖는 적응형 이동평균 (A-MA) 관리도)

  • Lim, Tae-Jin
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.33 no.4
    • /
    • pp.457-468
    • /
    • 2007
  • This paper proposes an adaptive moving average (A-MA) control chart with variable sampling intervals (VSI) for detecting shifts in the process mean. The basic idea of the VSI A-MA chart is to adjust sampling intervals as well as to accumulate previous samples selectively in order to increase the sensitivity. The VSI A-MA chart employs a threshold limit to determine whether or not to increase sampling rate as well as to accumulate previous samples. If a standardized control statistic falls outside the threshold limit, the next sample is taken with higher sampling rate and is accumulated to calculate the next control statistic. If the control statistic falls within the threshold limit, the next sample is taken with lower sampling rate and only the sample is used to get the control statistic. The VSI A-MA chart produces an 'out-of-control' signal either when any control statistic falls outside the control limit or when L-consecutive control statistics fall outside the threshold limit. The control length L is introduced to prevent small mean shifts from being undetected for a long period. A Markov chain model is employed to investigate the VSI A-MA sampling process. Formulae related to the steady state average time-to signal (ATS) for an in-control state and out-of-control state are derived in closed forms. A statistical design procedure for the VSI A-MA chart is proposed. Comparative studies show that the proposed VSI A-MA chart is uniformly superior to the adaptive Cumulative sum (CUSUM) chart and to the Exponentially Weighted Moving Average (EWMA) chart, and is comparable to the variable sampling size (VSS) VSI EWMA chart with respect to the ATS performance.

A Selectively Cumulative Sum (S-CUSUM) Control Chart with Variable Sampling Intervals (VSI) (가변 샘플링 간격(VSI)을 갖는 선택적 누적합 (S-CUSUM) 관리도)

  • Im, Tae-Jin
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2006.11a
    • /
    • pp.560-570
    • /
    • 2006
  • This paper proposes a selectively cumulative sum (S-CUSUM) control chart with variable sampling intervals (VSI) for detecting shifts in the process mean. The basic idea of the VSI S-CUSUM chart is to adjust sampling intervals and to accumulate previous samples selectively in order to increase the sensitivity. The VSI S-CUSUM chart employs a threshold limit to determine whether to increase sampling rate as well as to accumulate previous samples or not. If a standardized control statistic falls outside the threshold limit, the next sample is taken with higher sampling rate and is accumulated to calculate the next control statistic. If the control statistic falls within the threshold limit, the next sample is taken with lower sampling rate and only the sample is used to get the control statistic. The VSI S-CUSUM chart produces an 'out-of-control' signal either when any control statistic falls outside the control limit or when L-consecutive control statistics fall outside the threshold limit. The number L is a decision variable and is called a 'control length'. A Markov chain model is employed to describe the VSI S-CUSUM sampling process. Some useful formulae related to the steady state average time-to signal (ATS) for an in-control state and out-of-control state are derived in closed forms. A statistical design procedure for the VSI S-CUSUM chart is proposed. Comparative studies show that the proposed VSI S-CUSUM chart is uniformly superior to the VSI CUSUM chart or to the Exponentially Weighted Moving Average (EWMA) chart with respect to the ATS performance.

  • PDF

The Effect of Electroacupuncture on Pain Threshold and 5.Hydroxytryptamine Synthesis Induced by Nociception in the Raphe Magnus Nucleus of Dog Brain Stem (개의 발에 염증 유발 후 전침이 통증역치 및 뇌줄기 큰솔기핵의 5-Hydroxytryptamine 합성에 미치는 효과)

  • Cho, Mi-Suk
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.1
    • /
    • pp.59-66
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the effect of electroacupuncture on pain threshold and 5-HT synthesis in raphe magnus nucleus of dog brain stem following nociception induced by 1% carageenan. Method: Twenty male dogs were randomly divided into two groups, a control group and an electroacupuncture group with the following parameters: ST36, LI11 and SP9 with 120Hz and 0.5mA. The dogs were sacrificed at 30, 60, 90, 120, 150 and 180 min after nociception using 1% carageenan injection into the plantar side of the dog's left leg. The pain threshold was recorded by an Analgesia-meter. After making brain slice sections, the tissues were immunostained with 5-HT antisera (1:2,500). Results: The pain threshold for the electroacupuncture group was higher than for the control group. The number of 5-HT immunoreactive neurons in the electroacupuncture group was greater than that of the control group. Differences between the two groups regarding the number of 5-HT immunoreactive neurons at 30 min and 60 min (p<0.05), at 120 min and 150 min (p<0.01), and at 8 days (p<0.05) were significant. Conclusion: The increases in pain threshold and number of 5-HT immunoreactive neurons in the raphe magnus nucleus of dog brain stem showed that electroacupuncture can attenuate pain transduction through the descending tract.

Effect of Neuro-Feedback Training and Transcutaneous Electrical Nerve Stimulation (TENS) in Stress, Quantitative Sensory Threshold, Pain on Tension Type Headache

  • Lee, Young-Sin;Lee, Dong-Jin;Han, Sang-Wan;Kim, Kyeong-Tae
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.6
    • /
    • pp.442-448
    • /
    • 2014
  • Purpose: The objective of this study is to evaluate the effect of neuro-feedback training and transcutaneous electrical nerve stimulation (TENS) on stress, quantitative sensory threshold and pain in patients suffering from tension type headache. Methods: 22 participants who passed the preliminary evaluation were enrolled in the study and 11 participants were randomly assigned to each group. The control group (n=11) was subject to the TENS treatment of which was composed of a 20-minute session for 5 times a week during 4 weeks, and the experimental group (n=11) was subject to both neuro feedback training and TENS treatment for 10 minutes a day and 5 days a week during 4 weeks. The Perceived Stress Scale (PSS) was used to measure a level of stress and the quantitative sensory testing (QST) was used for the measurement of cold pain threshold (CPT) and heat pain threshold (HPT); A degree of pain was evaluated through the headache impact test-6 (HIT-6). Results: In comparision of all dependent variables between the control and subject groups, there were significant differences in stress, quantitative sensory threshold and pain after the treatment (p<0.05), and the experimental group showed significant differences in stress, CPT, HPT and pain (p<0.05) and the control group showed only a significant difference in HPT (p<0.05). Conclusion: Findings of this study demonstrate that the concomitant administration of the TENS treatment and neuro feedback training is effective on alleviation of stress, quantitative sensory threshold and pain in patients with tension type headache.

A Study on the Anesthetic Effects of Pulsed Nd:YAG Laser Irradiation to the Oral Mucosa and the Teeth (Nd:YAG 레이저 조사에 의한 치아 및 구강점막의 마취효과)

  • 최재갑
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.1
    • /
    • pp.1-9
    • /
    • 1998
  • The aim of the study was to evaluate the anesthetic Effecs of pulsed Nd:YAG laser irradiation to the oral mucosa and the teeth. Twenty subjects who didn't have a history of significant systemic or current oral disease were included in this study. All the subjects were divided randomly into the experimental group and the control group with 10 for each group. Pain thresholds were measured with Weighted Needle Pinprick Sensory Threshold Test for the mucosal surface of lower lip and with electric pulp test for the upper right central incisor respectively, before and immediately after pulsed Nd:YAG laser irradiation in the condition of 2 watt, 20pps for 2 minute at 10mm distance. The experiment was double-blinded clinical trial. The results were as follows : 1. The mean pain threshold of the mucosal surface of lower lip for Weighted Needle Pinprick Sensory Threshold Test was 2.94(1.00g for the contral group respectively, and there was no statistical difference between two groups. 2. The mean pain threshold of the mucosal surface of lower lip was significantly increased immediately after pulsed Nd:YAG laser irradiation. 3. The mean pain threshold of the upper right central incisor for eledtric pulp test was 34.50(4.97V in the experimental group and 34.00(13.08V in the control group respectively, and there was no statistical difference between two groups. 4. The mean pain threshold of the upper right central incisor was significantly increased immediately after pulsed Nd:YAG laser irradiation.

  • PDF

Increasing Effect of Laser Stimulation to Koryo-Hand Acupuncture Points on Experimental Pressure Threshold (고려수지기맥 레이저 자극의 압통 역치상승 효과)

  • Park, Boe-Kyung;Yi, Jong-Eun;Song, Byung-Chul;Yi, Jin-Bock;Ahn, Duck-Hyun
    • Physical Therapy Korea
    • /
    • v.5 no.2
    • /
    • pp.1-14
    • /
    • 1998
  • This study was conducted to examine the increasing effects of Ga-As-Al laser Koryo-hand acupuncture on experimental pressure threshold. Forty healthy subjects (female=20. male=20) aged 21 to 30 years were randomly assigned to two treatment groups with same ratio in sex. The subjects in the experimental group (n=20) received Ga-As-Al laser stimulation, and those in the control group (n=20) received sham stimulation on appropriate Koryo-hand acupuncture points M10 on the left hand which is reflex point of upper trapezius portion. Experimental pressure threshold at the contralateral upper trapezius was determined with a pressure algometer and Galvanic Skin Response (GSR) before and after treatment. The change of pressure threshold between pretreatment and posttreatment in the experimental group was greater than that in the control group (p<0.05). The result indicates that Ga-As-Al laser Koryo-hand acupuncture increases experimental pressure threshold and suggests that it is an effective noninvasive pain management technique.

  • PDF

Selection of Signal Strength and Detection Threshold for Optimal Tracking with Nearest Neighbor Filter (NN 필터 추적을 위한 최적 신호 강도 및 검출 문턱값 선택)

  • Jeong, Yeong-Heon;Gwon, Il-Hwan;Hong, Sun-Mok
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.37 no.3
    • /
    • pp.1-8
    • /
    • 2000
  • In this paper, we formulate an optimal control problem to obtain the optimal signal strength and detection threshold for tracking with NN filter, First, we predict the tracking performance of NN filter by using the HYCA method. Based on this method, the predicted tracking performance is represented with respect to signal strength and detection threshold. Using this relation, we find the optimal parameters for following three examples: 1) the sequence of optimal detection threshold which minimizes sum of position estimation error; 2) the sequence of optimal detection threshold which minimizes sum of validation gate volume; and 3) the sequence of optimal signal strength and detection threshold which minimizes sum of signal strength.

  • PDF

Fault Detection and Isolation using navigation performance-based Threshold for Redundant Inertial Sensors

  • Yang, Cheol-Kwan;Shim, Duk-Sun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2576-2581
    • /
    • 2003
  • We consider fault detection and isolation (FDI) problem for inertial navigation systems (INS) which use redundant inertial sensors and propose an FDI method using average of multiple parity vectors which reduce false alarm and wrong isolation, and improve correct isolation. We suggest optimal isolation threshold based on navigation performance, and suggest optimal sample number to obtain short detection time and to enhance detectability of faults little larger than threshold.

  • PDF