• Title/Summary/Keyword: control system and monitoring system development

Search Result 944, Processing Time 0.042 seconds

Application of Free Water Surface Constructed Wetland for NPS Control in Livestock Watershed Area (축산단지 비점오염물질 저감을 위한 자유수면형 인공습지 적용)

  • Lee, Jeong-Yong;Kang, Chang-Guk;Lee, So-Young;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.13 no.3
    • /
    • pp.481-488
    • /
    • 2011
  • Various development activities have lead to the destruction of the ecosystem such as natural wetlands. In order to protect these natural wetlands, the Ministry of Environment (MOE) in Korea enacted the Wetland Conservation Act in 1999 and designated protected areas for wetland conservation. The MOE adapted the use of Best Management Practices (BMP) such as retention ponds and constructed wetlands to treat the polluted water before entering the water system. One of these projects was a free-water surface flow (FWS) constructed wetland built as a secondary treatment unit for piggery wastewater effluent coming from a livestock wastewater treatment facility. Water quality monitoring for the constructed wetland was conducted during rainfall events. The results showed that the average removal efficiencies of TSS, BOD, TN, TP were 86, 60, 45, 70%, respectively. It was observed that the removal efficiency of particulate matter and phosphorus was high compared to nitrogen. Therefore, a longer hydraulic retention time was needed in order to improve the treatment efficiency of nitrogen. The results of this study can contribute to the wetland design, operation and maintenance of constructed wetlands.

A study on liquid crystal-based electrical polarization control technology for polarized image monitoring device (편광 영상감시 장치를 위한 액정 기반 전기적 편광 조절 기술 연구)

  • Ahn, Hyeon-Sik;Lim, Seong-Min;Jang, Eun-Jeong;Choi, Yoonseuk
    • Journal of IKEEE
    • /
    • v.26 no.3
    • /
    • pp.416-421
    • /
    • 2022
  • In this study, we present a fully automated system that combines camera technology with liquid crystal technology to create a polarization camera capable of detecting the partial linear polarization of light reflected from an object. The use of twisted nematic (TN) liquid crystals that electro-optically modulate the polarization plane of light eliminates the need to mechanically rotate the polarizing filter in front of the camera lens. Images obtained using these techniques are imaged by computer software. In addition, liquid crystal panels have been produced in a square shape, but many camera lenses are usually round, and lighting or other driving units are installed around the lens, so space is optimized through the application of a circular liquid crystal display. Through the development of this technology, an electrically switchable and space-optimized liquid crystal polarizer is developed.

Development of Remote Monitoring and Control System of the Environment in the Mushroom Production House (버섯재배사 원격 환경 모니터링 및 제어시스템 개발)

  • Lee, Sunghyoun;Yu, Byeongkee;Lee, Chanjung
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.121-121
    • /
    • 2017
  • 오늘날 시장에 유통되는 버섯은 대부분 환경이 조절되는 시설 내부에서 재배된다. 버섯은 다른 식물과 달리 버섯의 종류, 품종 등에 따라 요구되는 환경이 매우 다르다. 특히 대부분의 버섯은 버섯이 생육되는 공간의 온도, 수분, 이산화탄소, 조도 등의 관리가 필수적이다. 버섯의 단위면적당 생산량을 극대화하기 위해서는 이들 버섯이 필요로 하는 환경을 버섯의 생육특성에 따라 적합하게 유지해 주어야만 한다. 현재 대부분의 버섯재배사에는 이들 환경을 컨트롤하는 장치가 설치되어 있고, 이들 시스템의 환경 설정은 농업인이 현장에서 버섯의 상태를 확인 한 후 그때그때 경험에 의해 채득한 정보를 기반으로 환경설정을 하고 있는 실정이다. 이렇다 보니 버섯을 재배하는 기간에는 농업인이 재배사 내부의 환경을 관리하기 위해서 항상 버섯재배사에 머물러야 하고, 재배사의 환경관리 때문에 원거리 또는 장기 출타가 어려운 실정이다. 본 연구에서는 기존에 사람이 버섯재배 현장에서 컨트롤하던 환경관리를 원격에서 컴퓨터 또는 모바일로 구현할 수 있는 시스템을 개발하였다. 시스템에서 모니터링 및 제어하는 환경은 온도, 습도, 이산화탄소, 배기팬 및 입기팬의 가동 등 버섯재배 환경관리에 필요한 모든 요소를 모니터링 및 관리할 수 있도록 하였다. 이들 관리 요소는 인터넷이 연결된 컴퓨터에 접속하여 버섯재배사의 환경을 실시간으로 모니터링 하고 필요에 따라 제어를 할 수 있도록 하였다. 또한 컴퓨터에서 볼 수 있는 환경을 스마트폰을 통해서도 볼 수 있고 또한 제어할 수 있도록 하였다. 그리고 버섯배지를 입상 한 후부터 수확시기까지의 관리 환경을 데이터베이스로 만들어 농민이 버섯배지를 입상하고 데이터베이스와 연동한 제어가 되도록 설정하면 버섯재배사 내부의 환경은 데이터베이스의 정보를 읽어 들여 버섯의 생육단계에 따라 자동으로 내부환경이 제어되도록 하였다. 또한 농업인이 원격에서 버섯재배사 내부 버섯의 생육상황을 모니터링 할 수 있도록 재배사 상부에 CCD 카메라를 달아 실시간으로 버섯의 생육상활을 모니터링 할 수 있도록 구성하였다. 이와 같은 시스템을 사용하면 버섯재배 경험이 없는 농업인도 경험자와 같은 재배관리가 가능하고 원격에서 재배사 내부환경을 모니터링하고 제어 할 수 있기 때문에 농업인이 재배사에 매여 있지않아도 될 것으로 판단된다.

  • PDF

Approaching Method for Detecting Vessels in the Korean Waters using the Panchromatic Imagery of IRS-1C Satellite (Panchromatic 위성 자료를 이용한 선박 확인의 접근 기법)

  • Suh, Young-Sang;Choi, Chul-Uong;Lee, Na-Kyung;Kim, Bok-Kee;Jang, Lee-Hyun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.5 no.4
    • /
    • pp.86-92
    • /
    • 2002
  • The feasibility of counting number of small vessels and position in Korean waters using the panchromatic imageries derived from the IRS-1C was tested. The parameters for interpretation of satellite's imageries of small vessels were location(position), size, shape, shadow, tone, texture and pattern, height and depth, situation and association with other vessels. The position of small vessels in the sea without GCP(ground control point) was considered to be inclusive in the satellite imagery with 35 km semi-diameter, denoting rough geographical position of the vessel. The size of vessel was measured by length from stem to stern of the vessel, distinguished by following wave on the surface water. Offshore fishing vessels were separated from merchant ships by their length smaller than 100 m. The shape of vessels on panchromatic imagery of IRS-1C appeared just streamline. In case of clouds which were similar to the shape of small vessels, we were able to distinguish between vessel and cloud by shadow of cloud in the water surface. The tone of sea surface was dark black while small vessel appeared bright white. Small vessel was distinguished from the rough texture of the sea surface and the regular pattern of the waves with white capes when weather was not so good. The situation of the fishing activity was estimated by information of fishing method related to the fishing boat such as the pair trawl in the Yellow Sea.

  • PDF

GPS-based monitoring and modeling of the ionosphere and its applications for high accuracy correction in China

  • Yunbin, Yuan;Jikun, Ou;Xingliang, Huo;Debao, Wen;Genyou, Liu;Yanji, Chai;Renggui, Yang;Xiaowen, Luo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.203-208
    • /
    • 2006
  • The main research conducted previously on GPS ionosphere in China is first introduced. Besides, the current investigations include as follows: (1) GPS-based spatial environmental, especially the ionosphere, monitoring, modeling and analysis, including ground/space-based GPS ionosphere electron density (IED) through occultation/tomography technologies with GPS data from global/regional network, development of a GNSS-based platform for imaging ionosphere and atmosphere (GPFIIA), and preliminary test results through performing the first 3D imaging for the IED over China, (2) The atmospheric and ionospheric modeling for GPS-based surveying, navigation and orbit determination, involving high precisely ionospheric TEC modeling for phase-based long/median range network RTK system for achieving CM-level real time positioning, next generation GNSS broadcast ionospheric time-delay algorithm required for higher correction accuracy, and orbit determination for Low-Earth-orbiter satellites using single frequency GPS receivers, and (3) Research products in applications for national significant projects: GPS-based ionospheric effects modeling for precise positioning and orbit determination applied to China's manned space-engineering, including spatial robot navigation and control and international space station intersection and docking required for related national significant projects.

  • PDF

The Implementation of a HACCP System through u-HACCP Application and the Verification of Microbial Quality Improvement in a Small Size Restaurant (소규모 외식업체용 IP-USN을 활용한 HACCP 시스템 적용 및 유효성 검증)

  • Lim, Tae-Hyeon;Choi, Jung-Hwa;Kang, Young-Jae;Kwak, Tong-Kyung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.3
    • /
    • pp.464-477
    • /
    • 2013
  • There is a great need to develop a training program proven to change behavior and improve knowledge. The purpose of this study was to evaluate employee hygiene knowledge, hygiene practice, and cleanliness, before and after HACCP system implementation at one small-size restaurant. The efficiency of the system was analyzed using time-temperature control after implementation of u-HACCP$^{(R)}$. The employee hygiene knowledge and practices showed a significant improvement (p<0.05) after HACCP system implementation. In non-heating processes, such as seasoned lettuce, controlling the sanitation of the cooking facility and the chlorination of raw ingredients were identified as the significant CCP. Sanitizing was an important CCP because total bacteria were reduced 2~4 log CFU/g after implementation of HACCP. In bean sprouts, microbial levels decreased from 4.20 logCFU/g to 3.26 logCFU/g. There were significant correlations between hygiene knowledge, practice, and microbiological contamination. First, personnel hygiene had a significant correlation with 'total food hygiene knowledge' scores (p<0.05). Second, total food hygiene practice scores had a significant correlation (p<0.05) with improved microbiological qualities of lettuce salad. Third, concerning the assessment of microbiological quality after 1 month, there were significant (p<0.05) improvements in times of heating, and the washing and division process. On the other hand, after 2 months, microbiological was maintained, although only two categories (division process and kitchen floor) were improved. This study also investigated time-temperature control by using ubiquitous sensor networks (USN) consisting of an ubi reader (CCP thermometer), an ubi manager (tablet PC), and application software (HACCP monitoring system). The result of the temperature control before and after USN showed better thermal management (accuracy, efficiency, consistency of time control). Based on the results, strict time-temperature control could be an effective method to prevent foodborne illness.

The Development of a Multi-Purpose Irradiator and the Characteristic of Dose Distribution (다목적 방사선 조사장치 개발 및 선량분포특성)

  • Lee, Dong-Hoon;Ji, Young-Hoon;Lee, Dong-Han;Kim, Yoon-Jong;Hong, Seung-Hong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.6
    • /
    • pp.42-48
    • /
    • 2002
  • The design, construction and performance test of a convenient multi-purpose irradiator is described. A multi-purpose irradiator using Cesium-137 has been developed for studies of low dose radiation effects in biology and for calibration of Thermo Luminescent dosimeter(TLD). During the operation, three rods of radioactive material which are 10cm in length revolve 180 degrees and irradiate biological samples, or TLD, and return to their shielded position, after the programmed time. A programmable Logic Controller(PLC) controls the sequence of operation, interlock, motor rotation and safety system. The rotation speed of biological samples can vary up to 20 RPM. A real time monitoring system was also incorporated to check and control the operation status of the irradiator. The capacity of the irradiation chamber was 4.5 liters. The isodose distribution at arbitrary vertical planes was measured by using film dosimetry. The dose-rate was 0.13 cGy/min in air and 0.11 cGy/min in water equivalent material in the case of Cesium-137. Range of activity was 2 Ci. The homogeneity of dose distribution in the chamber was ${\pm}$7%. The actual radiation level on the surface was within permissible levels. The irradiator had a maximum 0.35 mR/min radiation leakage on its surface.

Analytical Determination of Vitamin B12 Content in Infant and Toddler Milk Formulas by Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)

  • Lee, Jung-Hoon;Shin, Jin-Ho;Park, Jung-Min;Kim, Ha-Jung;Ahn, Jang-Hyuk;Kwak, Byung-Man;Kim, Jin-Man
    • Food Science of Animal Resources
    • /
    • v.35 no.6
    • /
    • pp.765-771
    • /
    • 2015
  • The development of a sample preparation method and optimization of the analytical instrumentation conditions were performed for the determination of the vitamin B12 content in emulsified baby foods sold on the Korea market. After removal of the milk protein and fats by chloroform extraction and centrifugation, the vitamin B12 was water extracted from the sample. Following filtration of the solution through a nylon filter, the water-soluble extract was purified by solid-phase extraction using a Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS). The solution eluted from the cartridge was dried under a stream of nitrogen gas and reconstituted with 1 mL of water. The sample solution was injected into an LC-MS/MS system after optimizing the mobile phase for vitamin B12 detection. The calibration curve showed good linearity with the coefficient of correlation (r2) value of 0.9999. The limit of detection was 0.03 µg/L and the limit of quantitation was 0.1 µg/L. The method of detection limit was 0.02 µg/kg. The vitamin B12 recovery from a spiking test was 99.62% for infant formula and 99.46% for cereal-based baby food. The sample preparation method developed in this study would be appropriate for the rapid determination of the vitamin B12 content in infant formula and baby foods with emulsified milk characteristics. The ability to obtain stable results more quickly and efficiently would also allow governments to exercise a more extensive quality control inspection and monitoring of products expected to contain vitamin B12. This method could be implemented in laboratories that require time and labor saving.

Network Adaptive Quality of Service Method in Client/Server-based Streaming Systems (클라이언트/서버 기반 스트리밍 시스템에서의 네트워크 적응형 QoS 기법)

  • Zhung, Yon-il;Lee, Jung-chan;Lee, Sung-young
    • The KIPS Transactions:PartA
    • /
    • v.10A no.6
    • /
    • pp.691-700
    • /
    • 2003
  • Due to the fast development of wire&wireless internet and computer hardware, more and more internet services are being developed, such as Internet broadcast, VoD (Video On Demand), etc. So QoS (Qualify of Service) is essentially needed to guarantee the quality of these services. Traditional Internet is Best-Effort service in which all packets are transported in FIFO (First In First Out) style. However, FIFO is not suitable to guarantee the quality of some services, so more research in QoS router and QoS protocol are needed. Researched QoS router and protocol are high cost and inefficient because the existing infra is not used. To solve this problem, a new QoS control method, named Network Adaptive QoS, is introduced and applied to client/server-based streaming systems. Based on network bandwidth monitoring mechanism, network adaptive QoS control method can be used in wire&wireless networks to support QoS in real-time streaming system. In order to reduce application cost, the existing streaming service is used in NAQoS. A new module is integrated into the existing server and client. So the router and network line are not changed. By simulation in heavy traffic network conditions, we proved that stream cannot be seamless without network adaptive QoS method.

The Influence of Obstructive Sleep Apnea on Systemic Blood Pressure, Cardiac Rhythm and the Changes of Urinary (폐쇄성 수면 무호흡이 전신성 혈압, 심조율 및 요 Catecholamines 농도 변화에 미치는 영향)

  • Lo, Dae-Keun;Choi, Young-Mee;Song, Jeong-Sup;Park, Sung-Hak;Moon, Hwa-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.153-168
    • /
    • 1998
  • Background: The existing data indicate that obstructive sleep apnea syndrome contributes to the development of cardiovascular dysfunction such as systemic hypertension and cardiac arrhythmias, and the cardiovascular dysfunction has a major effect on high long-term mortality rate in obstructive sleep apnea syndrome patients. To a large extent the various studies have helped to clarify the pathophysiology of obstructive sleep apnea, but many basic questions still remain unanswered. Methods: In this study, the influence of obstructive sleep apnea on systemic blood pressure, cardiac rhythm and urinary catecholamines concentration was evaluated. Over-night polysomnography, 24-hour ambulatory blood pressure and ECG monitoring, and measurement of urinary catecholamines, norepinephrine (UNE) and epinephrine (UEP), during waking and sleep were undertaken in obstructive sleep apnea syndrome patients group (OSAS, n=29) and control group (Control, n=25). Results: 1) In OSAS and Control, UNE and UEP concentrations during sleep were significantly lower than during waking (P<0.01). In UNE concentrations during sleep, OSAS showed higher levels compare to Control (P<0.05). 2) In OSAS, there was a increasing tendency of the number of non-dipper of nocturnal blood pressure compare to Control (P=0.089). 3) In both group (n=54), mean systolic blood pressure during waking and sleep showed significant correlation with polysomnographic data including apnea index (AI), apnea-hypopnea index (AHI), arterial oxygen saturation nadir ($SaO_2$ nadir) and degree of oxygen desaturation (DOD). And UNE concentrations during sleep were correlated with AI, AHI, $SaO_2$ nadir, DOD and mean diastolic blood pressure during sleep. 4) In OSAS with AI>20 (n==14), there was a significant difference of heart rates before, during and after apneic events (P<0.01), and these changes of heart rates were correlated with the duration of apnea (P<0.01). The difference of heart rates between apneic and postapneic period (${\Delta}HR$) was significantly correlated with the difference of arterial oxygen saturation between before and after apneic event (${\Delta}SaO_2$) (r=0.223, P<0.001). 5) There was no significant difference in the incidence of cardiac arrhythmias between OSAS and Control In Control, the incidence of ventricular ectopy during sleep was significantly lower than during waking. But in OSAS, there was no difference between during waking and sleep. Conclusion : These results suggested that recurrent hypoxia and arousals from sleep in patients with obstructive sleep apnea syndrome may increase sympathetic nervous system activity, and recurrent hypoxia and increased sympathetic nervous system activity could contribute to the development of cardiovascular dysfunction including the changes of systemic blood pressure and cardiac function.

  • PDF