• Title/Summary/Keyword: control surfaces

Search Result 1,220, Processing Time 0.025 seconds

A Polarization-based Frequency Scanning Interferometer and the Measurement Processing Acceleration based on Parallel Programing (편광 기반 주파수 스캐닝 간섭 시스템 및 병렬 프로그래밍 기반 측정 고속화)

  • Lee, Seung Hyun;Kim, Min Young
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.8
    • /
    • pp.253-263
    • /
    • 2013
  • Frequency Scanning Interferometry(FSI) system, one of the most promising optical surface measurement techniques, generally results in superior optical performance comparing with other 3-dimensional measuring methods as its hardware structure is fixed in operation and only the light frequency is scanned in a specific spectral band without vertical scanning of the target surface or the objective lens. FSI system collects a set of images of interference fringe by changing the frequency of light source. After that, it transforms intensity data of acquired image into frequency information, and calculates the height profile of target objects with the help of frequency analysis based on Fast Fourier Transform(FFT). However, it still suffers from optical noise on target surfaces and relatively long processing time due to the number of images acquired in frequency scanning phase. 1) a Polarization-based Frequency Scanning Interferometry(PFSI) is proposed for optical noise robustness. It consists of tunable laser for light source, ${\lambda}/4$ plate in front of reference mirror, ${\lambda}/4$ plate in front of target object, polarizing beam splitter, polarizer in front of image sensor, polarizer in front of the fiber coupled light source, ${\lambda}/2$ plate between PBS and polarizer of the light source. Using the proposed system, we can solve the problem of fringe image with low contrast by using polarization technique. Also, we can control light distribution of object beam and reference beam. 2) the signal processing acceleration method is proposed for PFSI, based on parallel processing architecture, which consists of parallel processing hardware and software such as Graphic Processing Unit(GPU) and Compute Unified Device Architecture(CUDA). As a result, the processing time reaches into tact time level of real-time processing. Finally, the proposed system is evaluated in terms of accuracy and processing speed through a series of experiment and the obtained results show the effectiveness of the proposed system and method.

The effects of polishing technique and brushing on the surface roughness of acrylic resin (연마 방법과 칫솔질이 아크릴릭 레진의 표면 거칠기에 미치는 영향)

  • Lee, Ju-Ri;Jeong, Cheol-Ho;Choi, Jung-Han;Hwang, Jae-Woong;Lee, Dong-Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.287-293
    • /
    • 2010
  • Purpose: This study evaluated the effect of polishing techniques on surface roughness of polymethyl methacrylate (PMMA), as well as the influence of light-cured surface glaze and subsequent brushing on surface roughness. Materials and methods: A total of 60 PMMA specimens ($10{\times}10{\times}5\;mm$) were made and then divided into 6 groups of 10 each according to the polymerization methods (under pressure or atmosphere) and the surface polishing methods (mechanical or chemical polishing) including 2 control groups. The mechanical polishing was performed with the carbide denture bur, rubber points and then pumice and lathe wheel. The chemical polishing was performed by applying a light-cured surface glaze ($Plaquit^{(R)}$; Dreve-Dentamid GmbH). Accura $2000^{(R)}$, a non-contact, non-destructive, optical 3-dimensional surface analysis system, was used to measure the surface roughness (Ra) and 3-dimensional images were acquired. The surface roughness was again measured after ultrasonic tooth brushing in order to evaluate the influence of brushing on the surface roughness. The statistical analysis was performed with Mann-Whitney test and t-test using a 95% level of confidence. Results: The chemically polished group showed a statistically lower mean surface roughness in comparison to the mechanically polished group (P = .0045) and the specimens polymerized under the atmospheric pressure presented a more significant difference (P = .0138). After brushing, all of the groups, except the mechanically polished group, presented rougher surfaces and showed no statistically significant differences between groups. Conclusion: Although the surface roughness increased after brushing, the chemical polishing technique presented an improved surface condition in comparison to the mechanical polishing technique.

Characteristics of Titanium Dioxide-Impregnated Fibrous Activated Carbon and Its Application for Odorous Pollutant (이산화티타늄 담지 섬유형 활성탄소의 특성 및 악취오염물질 제어를 위한 응용)

  • Jo, Wan-Kuen;Hwang, Eun-Song;Yang, Sung-Bong
    • Clean Technology
    • /
    • v.17 no.1
    • /
    • pp.48-55
    • /
    • 2011
  • The application of fibrous activated carbon (FAC)-titanium dioxide ($TiO_2$) hybrid system has not been reported yet for the control of malodorous dimethyl sulfide (DMS) at residential environmental levels. Accordingly, the current study was designed not only to characterize this hybrid system using x-ray diffraction method, particulate surface measurement and Fourier transform Infrared (FTIR) method, but also to evaluate its adsorptional photocatalytic activity (APA) for the DMS removal. The physical/surface characteristics of FAC-$TiO_2$ which was prepared in this study suggested that the hybrid material might have certain APA for DMS. The Brunauer-Emmett-Teller (BET) specific area, total pore volume, micropore volume and mesopore volume decreased all as the $TiO_2$ amounts coated on FAC increased, whereas the reverse was true for average pore diameter. $TiO_2$ coated onto FAC did not influence the adsorptional activity of FAC for the DMS input concentration of 0.5 ppm. The APA test of the hybrid material presented that the initial removal efficiencies of DMS were 93, 78, 71 and 57% for the flow rates of 0.5, 1.0, l.5 and 2.0 L/min, respectively, and they decreased somewhat 2 h after the experiment started and kept almost constant for the rest experimental period. Under this pseudo-equilibrium condition, the DMS removal efficiencies were 78, 58, 53 and 36% for the four flow rates, respectively. Meanwhile, there were no significant byproducts observed on the surfaces of the hybrid material. Consequently, this study suggests that, under the experimental conditions used in the present study, the hybrid material can be applied for DMS at residential environment levels without being interfered by any byproducts.

EFFECT OF A NEW RESIN MONOMER ON THE MICROLEAKAGE OF COMPOSITE RESIN RESTORATIONS (새로운 레진 단량체가 복합레진수복물의 미세변연누출에 미치는 영향)

  • Bae, J.H.;Kim, Y.K.;Yoon, P.Y.;Lee, M.A.;Cho, B.H.
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.5
    • /
    • pp.469-475
    • /
    • 2007
  • The purpose of this study was to evaluate the effect of a new resin monomer on the microleakage of composite resin restorations. By adding new methoxylated Bis-GMA (Bis-M-GMA, 2,2-bis[4-(2-methoxy-3-methacryloyloxy propoxy) phenyl] propane) having low viscosity, the content of TEGDMA which has adverse effects on polymerization shrinkage might be decreased. As a result, microleakage might be improved. $2\;mm\;{\times}\;2\;mm\;{\times}\;2\;mm$ cavities with occlusal margins in enamel and gingival margins in dentin were prepared on buccal and lingual surfaces of 40 extracted human premolars. Prepared teeth were randomly divided into four groups and restored with Clearfil SE bond (Kuraray, Japan) and one of experimental composite resins; EX1, Experimental composite resin1 (Bis-M-GMA/TEGDMA = 95/5 wt%, 40 mm nanofillers); EX2, Experimental composite resin2 (Bis-M-GMA/TEGDMA = 95/5 wt%, 20 mm nanofillers); EX3, Experimental composite resin3 (Bis-GMA/TEGDMA = 70/30 wt%, 40 nm nanofillers); and Filtek Z250 (3M ESPE, USA) was filed as a control group. The restored teeth were thermocycled, and immersed in 2% methylene blue solution for 24 hours. The teeth were sectioned buccolingually with a low speed diamond saw and evaluated for microleakage under stereomicroscope. The data were statistically analyzed by Pearson Chi-Square test and Fisher Exact test (p = 0.05). The microleakage scores seen at the enamel margin were significantly lower than those of dentin margin (p = 0.007). There were no significant differences among the composite resins in the microleakage scores within each margin (p > 0.05). Bis-M-GMA, a new resin monomer having low viscosity, might in part replace high viscous Bis-CMA and might improve the quality of composite resin.

INFLUENCE OF A SODIUM HYPOCHLORITE GEL ON MICROLEAKAGE OF COMPOSITE RESIN RESTORATIONS (차아염소산 나트륨의 사용이 복합레진 수복물의 미세누출에 미치는 영향)

  • Yang, Kye-Sik;Kim, Dae-Eop;Lee, Kwang-Hee;Jeong, Young-Nam
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.54-60
    • /
    • 2003
  • This study evaluated the influence of chemomechanical caries removal agent $Carisolv^{TM}$(MediTeam, Sweden) for composite resin adhesion to sound human permanent and primary dentin. The buccal/labial surfaces of 80 permanent molars and 80 primary incisors were used. Four types of adhesives and one composite resin were used; AQ Bond(Sun Medical, Japan), Clearfil SE Bond(Kuraray, Japan), Single Bond(3M, USA), Scotchbond Multi-Purpose(3M, USA) and Z100(3M, USA). One drop of $Carisolv^{TM}$(MediTeam, Sweden) was pretreated on the dentin for 0 second(control) and 60 seconds. The specimens were thermocycled for 1,000 times in baths kept 5 degrees C and 55 degrees C with a 30 seconds dwell time. Shear bond strengths were tested and the data was statistically analyzed using one-way ANOVA with subsequent post hoc Scheffe test at p<0.05. $Carisolv^{TM}$ treatment significantly decreased the shear bond strength. Shear bond strength of permanent dentin was significantly higher than that of primary dentin. Clearfil SE Bond treatment groups showed the highest shear bond strength and AQ Bond treatment groups showed the lowest shear bond strength.

  • PDF

Serum Beta-2 Microglobulin: a Possible Marker for Disease Progression in Egyptian Patients with Chronic HCV Related Liver Diseases

  • Ouda, SM;Khairy, AM;Sorour, Ashraf E;Mikhail, Mikhail Nasr
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7825-7829
    • /
    • 2015
  • Background: Egypt has the highest prevalence of HCV infection in the world (~14.7%). Around 10-15% of HCV-infected persons will advance to cirrhosis within the first 20 years. The incidence of HCC is expected to grow in the next two decades, largely due to HCV related cirrhosis, and detection of HCC at an early stage is critical for a favorable clinical outcome. No simple reliable non-invasive marker has been available till now. B2M, a non-glycosylated polypeptide composed of 99 amino acids, is one of the components of HLA class I molecules on the surfaces of all nucleated cells. It has been reported that the level of serum B2M is elevated in patients with chronic hepatitis C and HCV-related HCC when compared to HCV-negative patients or healthy donors. Determining the clinical utility of serum B2M as a marker for disease progression in Egyptian patients with HCV related chronic hepatitis, cirrhosis and hepatocellular carcinoma was the aim of the present study. Materials and Methods: In this analytical cross sectional study 92 participants were included in 4 equal groups: Group (1) non cirrhotic chronic HCV; Group (2) HCV related liver cirrhosis; Group (3) HCC on top of HCV,; and Group (4) healthy controls. History taking, clinical examination, routine labs and abdominal ultrasound were conducted for all patients, PCR and Metavir scores for group (1) patients, and triphasic CT abdomen and AFP for Group (3) patients. B2M levels were measured in serum with a fully-automated IMX system. Results: The mean serum B2M level of Group (1) was $4.25{\pm}1.48{\mu}g/ml$., Group (2) was $7.48{\pm}3.04$, Group (3) was $6.62{\pm}2.49$ and Group (4) was $1.62{\pm}0.63$. Serum B2M levels were significantly higher in diseased than control group (p<0.01) being significantly higher in cirrhosis ($7.48{\pm}3.04$) and HCC groups ($6.62{\pm}2.49$) than the HCV group ($4.25{\pm}1.48$) (p<0.01). There was a significant correlation between B2M Level and ALK, total and direct bilirubin and INR (p<0.05), and a significant inverse correlation between B2M level and albumin, total proteins, HB andWBCS values (p<0.05). There was no significant correlation between B2M level and viral load or Metavir score, largest tumour size or AFP (p>0.05). The best B2M cut-off for HCV diagnosis was 2.6 with a sensitivity of 100%, a specificity of 92%, a positive predictive value (PPV) of 97% and a negative predictive value (NPV) of 100%. The best B2M cut-off for HCC diagnosis was 4.55 which yielded sensitivity, specificity, positive predictive value, negative predictive values of 74%, 62%, 39.5, 87.8% respectively (p-value <0.01) while best cut-off for cirrhosis was 4.9, with sensitivity 74 % and specificity 74%.The sensitivity for HCC diagnosis increased upon B2M and AFP combined estimation to 91%, specificity to 79%, NPV to 95% and accuracy to 83%. Conclusions: Serum B2M level is elevated in HCV related chronic liver diseases and may be used as a marker for HCV disease progression towards cirrhosis and carcinoma.

Effect of Antibody Immobilization Method to Magnetic Micro Beads on its Immunobinding Characteristics (자성 미세입자에의 항체 고정화 방법이 면역결합반응에 미치는 영향)

  • Choi, Hyo Jin;Hwang, Sang Youn;Jang, Dae Ho;Cho, Hyung Min;Kang, Jung Hye;Seong, Gi Hun;Choo, Jae Bum;Lee, Eun Kyu
    • Korean Chemical Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.65-72
    • /
    • 2006
  • Recent technical advances in the biorecognition engineering and the microparticle fabrication may enable us to develop the single step purification using magnetic particle, because of its simplicity, efficacy, ease of automation, and process economics. In this study, we used commercial magnetic particles from Seradyn, Inc. (Indianapolis, USA). It was ca. 2.8 micron in diameter, consisted of polystyrene core and magnetite coating, and its surface had carboxyl groups. The model, capture protein was IgG and anti-IgG was used as the ligand molecule. We studied the different surfaces ('nude', ester-activated, and anti-IgG coated) for their biorecognition of IgG. At a high pH condition, we could reduce non-specific binding. Also anti-IgG immobilized magnetic particle could capture IgG more selectively. We attempted 'oriented immobilization' of anti-IgG, in which the polysaccharides moiety near the C-terminus was selectively oxidized and linked to the hydrazine-coated MP, to improve the efficacy of biorecognitive binding. Using this method, the IgG capturing ability was improved by ca. 2 fold. From the binary mixture of the IgG-insulin, IgG could be more selectively captured. In summary, the oriented immobilization of oxidized anti-IgG proved to be as effective as the streptavidin-biotin system and yet simpler and cost-effective. This immobilization method can find its applications in protein biochips and biotargeting.

Characterization of Arsenic Immobilization in the Myungbong Mine Tailing (명봉광산의 광미 내 비소의 고정화 특성 연구)

  • Lee, Woo-Chun;Jeong, Jong-Ok;Kim, Ju-Yong;Kim, Soon-Oh
    • Economic and Environmental Geology
    • /
    • v.43 no.2
    • /
    • pp.137-148
    • /
    • 2010
  • The Myoungbong mine located in Boseong-gun, Jellanamdo consists of Au-Ag bearing quartz veins which filled the fissures of Bulguksa granitic rocks of Cretaceous. The tailings obtained from the Myungbong mine were used to investigate the effects of various processes, such as oxidation of primary sulfides and formation(alteration) of secondary and/or tertiary minerals, on arsenic immobilization in tailings. This study was conducted via both mineralogical and chemical methods. Mineralogical methods used included gravity and magnetic separation, ultrasonic cleaning, and instrumental analyses(X-ray diffractometry, energy-dispersive spectroscopy, and electron probe microanalyzer) and aqua regia extraction technique for soils was applied to determine the elemental concentrations in the tailings. Iron (oxy)hydroxides formed as a result of oxidation of tailings were identified as three specific forms. The first form filled in rims and fissures of primary pyrites. The second one precipitated and coated the surfaces of gangue minerals and the final form was altered into yukonites. Initially, large amounts of acid-generating minerals, such as pyrite and arsenopyrite, might make the rapid progress of oxidation reactions, and lots of secondary minerals including iron (oxy)hydroxides and scorodite were formed. The rate of pH decrease in tailings diminished, in addition, as the exposure time of tailings to oxidation environments was prolonged and the acid-generating minerals were depleted. Rather, it is speculated that the pH of tailings increased, as the contribution of pH neutralization reactions by calcite contained in surrounding parental rocks became larger. The stability of secondary minerals, such as scorodite, were deteriorated due to the increase in pH, and finally arsenic might be leached out. Subsequently, calcimn and arsenic ions dissociated from calcites and scorodites were locally concentrated, and yukonite could be grown tertiarily. It is confirmed that this tertiary yukonite which is one of arsenate minerals and contains arsenic in high level plays a crucial role in immobilizing arsenic in tailings. In addition to immobilization of arsenic in yukonites, the results indicate that a huge amount of iron (oxy)hydroxides formed by weathering of pyrite which is one of typical primary minerals in tailings can strongly control arsenic behavior as well. Consequently, this study elucidates that through a sequence of various processes, arsenic which was leached out as a result of weathering of primary minerals, such as arsenopyrite, and/or redissolved from secondary minerals, such as scorodite, might be immobilized by various sorption reactions including adsorption, coprecipiation, and absorption.

Bacterial growth and carbon-to-phosphorus consumption in drinking water with different carbon and phosphorus levels (수돗물의 탄소와 인 농도에 따른 세균의 생장과 C/P 소모율)

  • Choi, Sung-Chan;Park, e-Keun;Kim, Yeong-Kwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.6
    • /
    • pp.689-701
    • /
    • 2013
  • Bacterial growth and corresponding consumption of carbon and phosphorus were examined in which tap water samples containing a very low concentration of free chlorine were supplemented with organic carbon and/or phosphorus. The experiments were performed in a fed-batch mode under a controlled temperature of $20^{\circ}C$. In the phosphorus alone-added water, there was no significant increase in bacterial numbers measured as heterotrophic plate count (HPC) in the bulk water. However, bacterial growth was stimulated by the addition of carbon (e.g., bulk HPC levels increased to $10^3CFU/mL$) and further stimulated by the combined addition of carbon and phosphorus (e.g., bulk HPC to $10^5CFU/mL$). The same effects were observed in biofilm HPC and biomass formed on polyethylene (PE) slide surfaces. In the water where organic carbon and phosphorus were added together, the highest biofilm HPC and biomass (measured as extracellular polymeric substance components) densities were observed which were $7.6{\times}10^5CFU/cm^2$ and $5.3{\mu}g/cm^2$, respectively. In addition to the bacterial growth, additions of organic carbon and/or phosphorus resulted in different bacterial carbon-to-phosphorus (C/P) consumption ratios. Compared to a typical bacterial C/P consumption ratio of 100:1, a higher C/P ratio (590:1) occurred in the carbon alone-added water, while a lower ratio (40:1) in phosphorus alone-added water. Comparative value (80:1) of C/P ratio was also observed in the water where organic carbon and phosphorus were added together. At the given experimental conditions, bacterial growth was deemed to be more sensitive to microbially available organic carbon than phosphorus. The effect of phosphorus addition, which resulted in a lower C/P consumption ratio, seemed to be tightly associated with the presence of microbially available organic carbon. These results suggested that the control of extrinsic carbon influx seemed to be more important to minimize bacterial regrowth in drinking water system, since even low content of phosphorus naturally occurring in drinking water was enough to allow a bacterial growth.

Physical Properties and Optical Symmetry of Some Bireflecting Ore Mineral Species (이방성(異方性) 자원광물(資源鑛物)의 물성(物性) 및 광학적(光學的) 대칭성(對稱性) 연구(硏究))

  • So, Chil-Sup;Doh, Seong-Jae;Lee, Kyeong-Yong
    • Economic and Environmental Geology
    • /
    • v.18 no.4
    • /
    • pp.343-355
    • /
    • 1985
  • Spectral reflectivity and microhardness were measured quantitatively on polished surfaces of a selection of bireflecting minerals obtained from several well known metallic deposits. Incremental errors are much higher than decremental errors and errors were found to be lowest in the spectral region close to the green wavelength ($544m{\mu}$). The characteristics of the spectral profile are significant in their control of white light color. The covellite and graphite have reflectivity profiles similar in shape for each principal direction, showing noticeable difference in magnitude between the profiles: The spectral reflectivity of covellite parallel to the extraordinary vibration is higher (R$$\simeq_-$$10%) than that parallel to the ordinary vibration and graphite shows opposite feature. Reflectivity of the enargite and famatinite cut parallel to the cleavage plane is always higher (R$$\simeq_-$$5%) than that of the section cut normal. The optical symmetry of 5 bireflecting minerals was determined by noting the variation in reflectivity at $544m{\mu}$. The data indicate that covellite is optically uniaxial positive and graphite is optically uniaxial negative. The Rm values for enargite and famatinite are clearly closer to the minimum value for the mineral ($R_1$) than to the maximum value ($R_2$) : the minerals can be recognized as optically biaxial positive. Enargite and famatinite cut parallel to cleavage have much higher hardness values (HV=> $200kg/mm^2$) than those cut normal to cleavage. Vickers indentations exhibit characteristic features for all the bireflecting mineral species studied. Broad radicle groupings of the mineral species can be made with regard to the reflectivity microhardness numbers.

  • PDF