• 제목/요약/키워드: contrast correction

검색결과 188건 처리시간 0.027초

Comparison of PET image quality using simultaneous PET/MR by attenuation correction with various MR pulse sequences

  • Park, Chan Rok;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제51권6호
    • /
    • pp.1610-1615
    • /
    • 2019
  • Positron emission tomography (PET)/magnetic resonance (MR) scanning has the advantage of less additional exposure to radiation than does PET/computed tomography (CT). In particular, MR based attenuation correction (MR AC) can greatly affect the image quality of PET and is frequently obtained using various MR sequences. Thus, the purpose of the current study was to quantitatively compare the image quality between MR non-AC (MR NAC) and MR AC in PET images with three MR sequences. Percent image uniformity (PIU), percent contrast recovery (PCR), and percent background variability (PBV) were estimated to evaluate the quality of PET images with MR AC. Based on the results of PIU, 15.2% increase in the average quality was observed for PET images with MR AC than for PET images with MR NAC. In addition, 28.6% and 71.1% improvement in the average results of PCR and PBV respectively, was observed for PET images with MR AC compared with that with MR NAC. Moreover, no significant difference was observed among the average values using three MR sequences. In conclusion, the current study demonstrated that PET with MR AC improved the image quality and can be help diagnosis in all MR sequence cases.

자동 컬러 보정 모듈을 가진 디지털 포토 키오스크 시스템의 설계 및 구현 (Design and Implementation of Digital Photo Kiosk System with Auto Color Correction Module)

  • 박태용;이명영;박기현;하영호
    • 대한전자공학회논문지SP
    • /
    • 제43권2호
    • /
    • pp.48-56
    • /
    • 2006
  • 본 논문에서는 사용자가 원하는 미디어를 제공하기위해 터치스크린과 출력 장치인 디지털 포토 프린터 사이의 색역을 고려하는 자동 컬러 보정 모듈을 가진 디지털 사진 인화 시스템인 디지털 포토 키오스크 시스템을 설계하고 구현하였다. 이 모듈은 디지털 카메라나 카메라폰으로 촬영된 영상에 대하여 고품질의 결과물을 제공할 수 있는 이미지 보정 기능을 수행하는 것이다. 이 기능은 실시간 처리를 위해 LUT(look-up table)로 구현되어 사용자의 원터치 방식으로 동작하는 인터페이스를 제공한다. 따라서 흑백모드, 원톤 색상모드, 밝기 및 채도 조절 등의 이미지 편집 기능으로 사용자의 취향에 맞는 사진을 출력할 수 있고, 입출력 장치간의 자동 컬러 보정 모듈을 지원함으로써 본 시스템은 부드러운 계조표현과 촬영 영상과 유사한 색의 사진을 제공할 수 있다.

열상장비의 실시간 영상 신호처리 (Real Time Image Processing of Thermal Imaging System)

  • 홍석민;유위경;윤은숙
    • 한국군사과학기술학회지
    • /
    • 제7권4호
    • /
    • pp.79-86
    • /
    • 2004
  • This paper has presented to the design results of the analog and digital signal processor for the 2nd generation thermal imaging system using $480\times6$ infrared focal plane array In order to correct non-uniformities of detector arrays, we have developed the 2-point correction method using the thermo electric cooler. Additionally, to enhance the image of low contrast and improve the detection capability, we developed the new technique of histogram processing being suitable for the characteristics of contrast distribution of thermal imagery. Through these image processing techniques, we obtained a high qualify thermal image and acquired good result.

핵자기 공명 단층 촬영에서의 자화율 강조 영상법 (Susceptibility Contrast Enhancement Imaging in MRI)

  • 노용만;문치웅;임태환;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.85-91
    • /
    • 1992
  • In MRI, an image contrast can be developed as a result of the susceptibility effect if an object has paramagnetic substances. This is mainly due to the non-uniform phase distribution or linear gradient developed by the magnetic susceptibility within a voxel, which in turn reduces the signal intensity; e.g., spin phases are dephased and thereby cancel each other resulting in a reduced signal. In this paper, a new concept for manipulating the susceptibility effect through the use of tailored RF pulses is proposed. As potential applications of the method, two different types of tailored RF pulses are introduced: one for susceptibility artifact correction and the other for contrast enhancement. The latter, for example, can be applied to angiography utilizing the paramagnetic property of deoxygenated blood. Both a theoretical study of the method and experimental results are reported.

  • PDF

Single Image Enhancement Using Inter-channel Correlation

  • Kim, Jin;Jeong, Soowoong;Kim, Yong-Ho;Lee, Sangkeun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제2권3호
    • /
    • pp.130-139
    • /
    • 2013
  • This paper proposes a new approach for enhancing digital images based on red channel information, which has the most analogous characteristics to invisible infrared rays. Specifically, a red channel in RGB space is used to analyze the image contents and improve the visual quality of the input images but it can cause unexpected problems, such as the over-enhancement of reddish input images. To resolve this problem, inter-channel correlations between the color channels were derived, and the weighting parameters for visually pleasant image fusion were estimated. Applying the parameters resulted in significant brightness as well as improvement in the dark and bright regions. Furthermore, simple contrast and color corrections were used to maintain the original contrast level and color tone. The main advantages of the proposed algorithm are 1) it can improve a given image considerably with a simple inter-channel correlation, 2) it can obtain a similar effect of using an extra infrared image, and 3) it is faster than other algorithms compared without artifacts including halo effects. The experimental results showed that the proposed approach could produce better natural images than the existing enhancement algorithms. Therefore, the proposed scheme can be a useful tool for improving the image quality in consumer imaging devices, such as compact cameras.

  • PDF

FAR INFRARED AND SUBMILLIMETRE SURVEYS: FROM IRAS TO AKARI, HERSCHEL AND PLANCK

  • Rowan-Robinson, Michael;Wang, Lingyu
    • 천문학논총
    • /
    • 제32권1호
    • /
    • pp.293-297
    • /
    • 2017
  • We discuss a new IRAS Faint Source Catalog galaxy redshift catalogue (RIFSCz) which incorporates data from Galex, SDSS, 2MASS, WISE, AKARI and Planck. AKARI fluxes are consistent with photometry from other far infrared and submillimetre missions provided an aperture correction is applied. Results from the Hermes-SWIRE survey in Lockman are also discussed briefly, and the strong contrast between the galaxy populations selected at 60 and $500{\mu}m$ is summarized.

Atmospheric correction by Spectral Shape Matching Method (SSMM): Accounting for horizontal inhomogeneity of the atmosphere

  • ;안유환
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 춘계학술대회 논문집
    • /
    • pp.341-343
    • /
    • 2006
  • The current spectral shape matching method (SSMM), developed by Ahn and Shanmugam (2004), relies on the assumption that the path radiance resulting from scattered photons due to air molecules and aerosols and possibly direct-reflected light from the air-sea interface is spatially homogeneous over the sub-scene of interest, enabling the retrieval of water-leaving radiances ($L_w$) from the satellite ocean color image data. This assumption remains valid for the clear atmospheric conditions, but when the distribution of aerosol loadings varies dramatically the above postulation of spatial homogeneity will be violated. In this study, we present the second version of SSMM which will take into account the horizontal variations of aerosol loading in the correction of atmospheric effects in SeaWiFS ocean color image data. The new version includes models for the correction of the effects of aerosols and Raleigh particles and a method fur computation of diffuse transmittance ($t_{os}$) as similar to SeaWiFS. We tested this method over the different optical environments and compared its effectiveness with the results of standard atmospheric correction (SAC) algorithm (Gordon and Wang, 1994) and those from in-situ observations. Findings revealed that the SAC algorithm appeared to distort the spectral shape of water-leaving radiance spectra in suspended sediments (SS) and algal bloom dominated-areas and frequently yielded underestimated or often negative values in the lower green and blue part of the electromagnetic spectrum. Retrieval of water-leaving radiances in coastal waters with very high sediments, for instance = > 8g $m^{-3}$, was not possible with the SAC algorithm. As the current SAC algorithm does not include models for the Asian aerosols, the water-leaving radiances over the aerosol-dominated areas could not be retrieved from the image and large errors often resulted from an inappropriate extrapolation of the estimated aerosol radiance from two IR bands to visible spectrum. In contrast to the above results, the new SSMM enabled accurate retrieval of water-leaving radiances in a various range of turbid waters with SS concentrations from 1 to 100 g $m^{-3}$ that closely matched with those from the in-situ observations. Regardless of the spectral band, the RMS error deviation was minimum of 0.003 and maximum of 0.46, in contrast with those of 0.26 and 0.81, respectively, for SAC algorithm. The new SSMM also remove all aerosol effects excluding areas for which the signal-to-noise ratio is much lower than the water signal.

  • PDF

경사모세관법에 의한 우의 적혈구침강 속도에 미치는 환경온도의 영향 (Effect of Ambient Temperature on Bovine Erythrocyte Sedimentation Rate as Measured by Angled Capillary Method)

  • 김경진;이방환
    • 한국임상수의학회지
    • /
    • 제4권1호
    • /
    • pp.395-401
    • /
    • 1987
  • In this study, the effect of ambient temperature on the 45$^{\circ}$micro ESR/hr of cattle blood were observed, and a correction chart for correcting observed values at any ambient temperature to standard values at 20$^{\circ}C$ was plotted. Besides, the effect of storage temperature of blood on the 45$^{\circ}$micro ESR/hr was surveyed. The results were as follows: 1. The values of the 45$^{\circ}$micro ESR/hr were increased as the ambient temperature were elevated(P<0.01), and lower the value of PCV, higher the effect of temperature on the 45$^{\circ}$micro ESR/hr was observed(P<0.01). 2. Regression of values of 45$^{\circ}$micro ESR to ambient temperature in all the group of different level of blood PCV showed linear regression with the highly significant coefficient of correlation. With the results, correction chart was drawn as in Fig. 1. 3. In the purpose to verify the reliability of correction chart, observed values of 45$^{\circ}$micro ESR/hr in field(out door) were corrected to values at 20$^{\circ}C$ by the correction chart(Fig. 1), comparing with the observed values at 20$^{\circ}C$ of standard temperature. No significant differences were found between two groups mentioned above. 4. In the study on the effect of storage temperature of the blood on the 45$^{\circ}$micro ESR/hr, group of storage temperature at 5$^{\circ}C$ showed statistically no significant differences untill 24 hours in contrast with standard control group.

  • PDF

비전기반 지능형 자동차를 위한 도로 주행 영상 개선 방법 (Road Image Enhancement Method for Vision-based Intelligent Vehicle)

  • 김승규;박대용;최영우
    • 인지과학
    • /
    • 제25권1호
    • /
    • pp.51-71
    • /
    • 2014
  • 본 논문에서는 도로 주행에서 취득한 영상을 개선하는 방법을 제안한다. 일반적인 도로주행 영상은 다양한 조명 환경과 날씨 상태로 인하여 선명하지 못한 영상이 취득되기도 한다. 특히 역광이나 야간에는 품질이 좋은 선명한 영상을 얻기가 더욱 어려우며, 이는 비전기반 지능형 자동차 기술의 응용에 많은 어려움을 준다. 인간의 시각 인지방법은 여러 가지조명 조건을 고려하여 색을 지각한다. 하지만 기존의 영상 개선 방법들은 광원의 위치와 광도, 기하학적 관계를 고려하지 않기 때문에 완벽한 결과를 얻기가 어려우며, 오히려 영상의 질이 떨어지는 경우도 발생한다. 본 논문에서는 이러한 문제점을 해결하기 위해서 1) 주어진 입력 영상의 전처리 과정을 수행한 후, 2) 선명도를 추정하여 색채의 대비를 평가하고, 3) 과대 및 과소평가 결과를 전처리된 영상과 혼합하여 사람이 지각하는 색상과 같이 개선된 영상을 얻는 효과적인 방법을 제안한다. 본 논문에서 제안하는 방법은 시각적으로 개선된 결과를 보여줄 뿐만 아니라 비전기반 지능형 자동차 기술의 한 응용분야인 교통표지판 검출의 전처리 과정으로 적용되어 성능이 향상됨을 확인할 수 있었다.

I-131 SPECT/CT 검사의 에서 조준기 종류에 따른 영상 비교 평가 (Comparison of Collimator Choice on Image Quality of I-131 in SPECT/CT)

  • 김정열;김주연;남궁혁;강천구;김재삼
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.33-42
    • /
    • 2014
  • I-131의 주 에너지는 364 keV이고 이차적으로 637과 723 keV의 감마선을 방출한다. 이런 이유로 I-131 핵종을 이용한 검사에서는 일반적으로 고 에너지 조준기를 사용하고 있다. 반면 중 에너지 조준기는 과도한 격벽 투과의 영향 때문에 사용이 권고되지 않지만 I-131의 낮은 선량에 대해 계수율의 민감도를 향상시키기 위해 중 에너지 조준기를 사용하기도 한다. 이에 본 연구에서는 I-131 SPECT/CT에서 고 에너지와 중 에너지 조준기를 사용하여 조준기 선택에 대한 영상의 영향을 평가하고자 한다. I-131 점 선원과 NEMA NU-2 IQ phantom을 이용하여 Siemens symbia T16 SPECT/CT 장비로 중 에너지 조준기와 고 에너지 조준기를 사용하였다. 영상획득은 단일 에너지 창과 삼중 에너지 창으로 각각 적용하여 영상을 획득하였고, 재구성방법은 반복재구성 기법인 Flash 3D를 이용하여 CTAC, Scatter correction 적용 유무와 Iteration과 subset의 횟수를 변경하여 획득된 영상을 재구성하였다. 획득된 영상을 분석하여 두 조준기의 민감도와 대조도 그리고 잡음을 비교 평가하였다. 민감도는 중 에너지 조준기가 고 에너지 조준기보다 높게 나타났다(중 에너지 조준기: 188.18 cps/MBq, 고 에너지 조준기: 46.31 cps/MBq). 대조도는 삼중 에너지 창과 고 에너지 조준기를 사용하고 CTAC를 적용하여 16 subset 8 iteration을 적용한 재구성영상에서 가장 높은 대조도를 나타냈고(TCQI=190.64), 동일한 조건에서 중 에너지 조준기를 사용하였을 경우는 고 에너지 조준기에 비해 낮은 대조도를 나타냈다(TCQI=66.05). 잡음평가에서는 고 에너지 조준기보다 중 에너지 조준기에서 높게 나타났다 (P<0.001). 적절한 조준기의 선택은 영상의 질에 있어 중요한 사항이다. 본 연구를 통해 고 에너지 감마선을 방출하는 I-131 검사에서는 일반적으로 사용되고 있는 고 에너지 조준기를 사용하는 것이 영상의 질에 있어 가장 권고되는 바이다. 하지만 에너지 창, 매트릭스 크기, 반복 재구성 조건(subset과 iteration 수) 그리고 CTAC 및 scatter correction 여부등과 같은 조건들을 적절히 적용한다면 낮은 선량의 낮은 민감도를 갖는 조건에서는 중 에너지 조준기를 사용할 수 있을 것으로 사료된다.

  • PDF