• Title/Summary/Keyword: contamination measurement

Search Result 233, Processing Time 0.033 seconds

The characteristic of the elcetrostatic probe surface heated with current (가열식(加熱式) 정전탐침전극(靜電探針電極)의 표면특성(表面特性))

  • Kwak, Y.S.;Cho, J.S.;Park, C.H.;Kim, K.H.;Kim, S.P.;Kim, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.151-154
    • /
    • 1989
  • In the measurement of plasma parameters of the plasma C.V.D with probe method, the most important problem is the contamination of the probe surface. In this paper, we observe the surface contamination of probe surface with microscope and determine the critical current and the critical time to sustain the clean surface of probe in the plasma C.V.D.

  • PDF

Analysis of Insulation Condition in High Voltage Motor Stator Windings Following Cleaning and Insulation Reinforcement (세척과 절연보강에 따른 고압전동기 고정자 권선의 절연상태 분석)

  • Kim, Hee-Dong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.6
    • /
    • pp.474-480
    • /
    • 2012
  • Diagnostic tests were performed on two high voltage(HV) motor stator windings. These tests included the measurement of insulation resistance, polarization index, AC current, dissipation factor($tan{\delta}$) and partial discharge(PD) magnitude. Surface contamination of HV motor stator windings has an effect on the AC current and $tan{\delta}$. When the stator windings were finished cleaning and insulation reinforcement, the increase rate of AC current(${\Delta}I$) and dissipation factor(${\Delta}tan{\delta}$) were very small compared to those before cleaning. However, the PD magnitude remained the same. These tests show that cleaning and insulation reinforcement of HV motor stator windings can reduce the insulation failure.

Automatic Measuring Apparatus for Salt and Dust Contamination (염진해 오손도 자동측정장치)

  • 최남호;구경완;이명섭;한상옥;정재기;조성배
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.187-190
    • /
    • 1999
  • To reduce the maintenance expence, and the possibility of electric outage and accident, accurate measurement should be carried. But the classical method has some problems in the aspect of man power, reliability, and expence. In this paper, we propose a new type apparatus, which could detect the degree of contamination on insulators on outdoor insulation system, such as transmission and distribution line insulator and bushing. The new type apparatus consists of Pelltier module, electrode system, and measuring part. At first leakage current detecting method was considered, then with the fault(oxidation of electrode) of that method we should propose a another method. We carried various test to prove the possiblity and reliability of the propoused apparatus. And we get some useful result with laboratory test.

  • PDF

The Distribution Characteristics of Salt Contaminants in West Coast Region with the Distance from Sea (해안도달 거리에 따른 서해안 지역 염해 오손물의 분포특성)

  • Choi, Nam-Ho;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.6
    • /
    • pp.276-280
    • /
    • 2001
  • This paper presents the result of a study on the distribution characteristics of salt contaminants in the west coast region, from Inchon to Yearsoo, of South Korea. To evaluate the distribution characteristics of salt contaminants, we had measured the equivalent salt deposit density(ESDD) with brush wiping method for thirteen month(from May 1999 to June 2000). Under the consideration on the measuring interval and method, normalization method was applied for the ESDD data. Besides the measurement, the chemical analysis (chromatography) was carried to investigate the relationship, between the electrical property and the amount of specific ingredient, such as sodium, magnesium and chloride. From the result, we could get the representative value of contamination for each site and distribution characteristics of salt contaminants with the distance from sea in the west coast.

  • PDF

Temperature Measurement of Silicon Wafers Using Phase Estimation of Acoustic Wave (음향파의 위상 추정을 이용한 실리콘 웨이퍼의 온도 측정)

  • Joonhyuk Kang;Lee, Seokwon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.11
    • /
    • pp.493-495
    • /
    • 2003
  • Accurate temperature measurement is a key factor to implement the rapid thermal processing(RTP). A temperature estimation method using acoustic wave has been proposed to overcome the inaccuracy and contamination problem of the previous methods. The proposed method, however, may suffer from the offset and low resolution problem since it is implemented in the time domain. This paper presents a temperature estimation method using the phase detection of acoustic wave. Based on the frequency domain approach, the proposed technique increases the resolution of the measured temperature and reduces the effect of noise. We investigate the performance of the proposed method via experiments.

Comparative study on the specimen thickness measurement using EELS and CBED methods

  • Yoon-Uk Heo
    • Applied Microscopy
    • /
    • v.50
    • /
    • pp.8.1-8.7
    • /
    • 2020
  • Two thickness measurement methods using an electron energy loss spectroscopy (EELS) and 10a convergent beam electron diffraction (CBED) were compared in an Fe-18Mn-0.7C alloy. The thin foil specimen was firstly tilted to satisfy 10a two-beam condition. Low loss spectra of EELS and CBED patterns were acquired in scanning transmission electron microscopy (STEM) and TEM-CBED modes under the two-beam condition. The log-ratio method was used for measuring the thin foil thickness. Kossel-Möllenstedt (K-M) fringe of the $13{\ba{1}}$ diffracted disk of austenite was analyzed to evaluate the thickness. The results prove the good coherency between both methods in the thickness range of 72 ~ 113 nm with a difference of less than 5%.

Long term activity measurement of the primary circuit water on the LVR-15 research reactor

  • Ladislav Viererbl;Vit Klupak;Hana Assmann Vratislavska
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1250-1253
    • /
    • 2024
  • Activity measurement of the primary circuit water of fission reactors is one method that can provide early detection of a damaged fuel assembly in the reactor core. This is an important aspect in the safe operation of the reactor and for radiation protection of staff. Radionuclides in the primary circuit water are produced by the activation of stable nuclides and the fission of fissile nuclides, mainly the isotope 235U. In the LVR-15 research reactor, measurement of the activity of the primary circuit water has been regularly undertaken since 1996. A water sample is taken from the primary circuit every week and the activities are measured four days later using gamma spectrometry. The results of these long-term measurements from 1996 to 2022 are presented. The activity time dependences of the individual radionuclides are discussed in relation to fuel assembly damage and for events connected to contamination of the water by objects inserted into the primary circuit during experiments carried out near the reactor core.

IMAGING SPECTROMETRY FOR DETECTING FECES AND INGESTA ON POULTRY CARCASSES

  • Park, Bo-Soon;William R.Windham;Kurt C.Lawrence;Smith, Douglas-P
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.3106-3106
    • /
    • 2001
  • Imaging spectrometry or hyperspectral imaging is a recent development that makes possible quantitative and qualitative measurement for food quality and safety. This paper presents the research results that a hyperspectral imaging system can be used effectively for detecting fecal (from duodenum, cecum, and colon) and ingesta contamination on poultry carcasses from the different feed meals (wheat, mile, and corn with soybean) for poultry safety inspection. A hyperspectral imaging system has been developed and tested for the identification of fecal and ingesta surface contamination on poultry carcasses. Hypercube image data including both spectral and spatial domains between 430 and 900 nm were acquired from poultry carcasses with fecal and ingesta contamination. A transportable hyperspectral imaging system including fiber optically fabricated line lights, motorized lens control for line scans, and hypercube image data from contaminated carcasses with different feeds are presented. Calibration method of a hyperspectral imaging system is demonstrated using different lighting sources and reflectance panels. Principal Component and Minimum Noise Fraction transformations will be discussed to characterize hyperspectral images and further image processing algorithms such as image band ratio of dual-wavelength images and its histogram stretching with thresholding process will be demonstrated to identify fecal and ingesta materials on poultry carcasses. This algorithm could be further applied for real-time classification of fecal and ingesta contamination on poultry carcasses in the poultry processing line.

  • PDF

Development of Radiation Sensor Based on Array SiPM for Measurement of Radioactive Contamination in Effluent (방류수의 방사능 오염 측정을 위한 배열형 SiPM 기반 방사선 검출 센서 제작)

  • Kim, Jeongho;Park, Hyemin;Joo, Koansik
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.232-236
    • /
    • 2018
  • A radiation detection sensor was developed and characterized by combining three types of CsI(Tl) scintillators and an array-type SiPM to detect the radioactive contamination of discharged water in real time. The characterization results showed that type 3 exhibited the most desirable characteristics in response linearity (R-square: 0.97889) according to detection sensitivity and incident radiation dose. Furthermore, in terms of spectral characteristics, type 3 exhibited 16.54% at 0.356 MeV (the emission gamma ray energy of $^{133}Ba$), 10.28% at 0.511 MeV (the emission gamma ray energy of $^{22}Na$), 9.68% at 0.356 MeV (the emission gamma ray energy of $^{137}Cs$), and 2.55% and 4.80% at 1.173 MeV and 1.332 MeV (the emission gamma ray energies of $^{60}Co$), respectively. These measurements confirmed the good energy characteristics. The results were used to evaluate the spectral characteristics and energy linearity in a mixed source using type 3 with the best detection characteristics. It was confirmed that the gamma ray peaks of $^{133}Ba$, $^{22}Na$, $^{137}Cs$, and $^{60}Co$ were well resolved. Moreover, it was confirmed that R-square, which is an indicator of energy linearity, was 0.99986. This indicates a good linearity characteristic. Based on this study, further commercialization studies will contribute to measurements in real time and to the management of the contamination caused by radioactive wastewater or radioactive material leakage, which originate from facilities that use radioactive isotopes or care facilities.

The Dyeing Properties and Antibiosis of Fabrics Dyed with Agastache rugosa Extract (배초향 추출액을 이용한 염색포의 염색성 및 항균성)

  • Park, Young-Hee
    • Journal of Fashion Business
    • /
    • v.16 no.1
    • /
    • pp.16-25
    • /
    • 2012
  • As the test results for surface color, dyeing durability, antibiosis of cotton fabrics and silk fabrics dyed with Agastache rugosa extract, the following conclusions were obtained. The surface color of all the dyed fabrics was confirmed mostly as a GY system. As the result of chrominance(${\Delta}E_{ab}$) measurement, in the case of cotton fabrics the dyed fabrics treated with $Al_2(SO_4)_3$ mordant showed the highest value and in the case of silk fabrics the non-mordant dyed fabrics showed the highest value. The dyeing durability of test fabrics dyed with Agastache rugosa extract are as follows. As the test results of colorfastness to laundry for cotton dyed fabrics, the discoloration degree showed 1st-2nd grade and the contamination degree showed 4th-5th grade. As the test result of colorfastness to dry cleaning for silk dyed fabrics, the contamination degree showed from 1st to 3rd-4th grade. As the test results of colorfastness to acid artificial perspiration, the discoloration degree showed from 1st to 3rd-4th grade and the contamination degree showed from 3rd to 4th-5th grade. As the test results of colorfastness to alkaline artificial perspiration, the discoloration degree showed from 1st to 4th grade and the contamination degree showed from 3rd to 4th-5th grade. The colorfastness to sunlight showed from 1st to 2nd grade. The colorfastness to rubbing showed from 3rd to 4th-5th grade in dry process and from 2nd-3rd to 4th-5th grade in wet process. As the test results of antibiosis, the decrease rate of germs to virus Klebsiella pneumoniae and Staphylococcus aureus showed at least more than 99% after the wash of 10 times. As the test results of antifungal activity to mycete Trichophyton mentagrophytes and Aspergillus niger, the both cotton and silk dyed fabrics didn't gain the significant antifungal effect.