• 제목/요약/키워드: contacts

검색결과 1,379건 처리시간 0.035초

Evolution of Interferon-Gamma Release Assay Results and Submillisievert Chest CT Findings among Close Contacts of Active Pulmonary Tuberculosis Patients

  • Yoon, Soonho;Mihn, Do-CiC;Song, Jin-Wha;Kim, Sung A;Yim, Jae-Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • 제83권4호
    • /
    • pp.283-288
    • /
    • 2020
  • Background: Latent tuberculosis (TB) infection among TB contacts is diagnosed using plain chest radiography and interferon-gamma release assays (IGRAs). However, plain chest radiographs often miss active TB, and the results of IGRA could fluctuate over time. The purpose of this study was to elucidate changes in the results of the serial IGRAs and in the findings of the serial submillisievert chest computed tomography (CT) scans among the close contacts of active pulmonary TB patients. Methods: Patients age 20 or older with active pulmonary TB and their close contacts were invited to participate in this study. Two types of IGRA (QuantiFERON-TB Gold In-Tube assay [QFT-GIT] and the T-SPOT.TB test [T-SPOT]) and submillisievert chest CT scanning were performed at baseline and at 3 and 12 months after enrollment. Results: In total, 19 close contacts participated in this study. One was diagnosed with active pulmonary TB and was excluded from further analysis. At baseline, four of 18 contacts (22.2%) showed positive results for QFT-GIT and T-SPOT; there were no discordant results. During the follow-up, transient and permanent positive or negative conversions and discordant results between the two types of IGRAs were observed in some patients. Among the 17 contacts who underwent submillisievert chest CT scanning, calcified nodules were identified in seven (41.2%), noncalcified nodules in 14 (82.4%), and bronchiectasis in four (23.5%). Some nodules disappeared over time. Conclusion: The results of the QFT-GIT and T-SPOT assays and the CT images may change during 1 year of observation of close contacts of the active TB patients.

Ohmic contacts to p-type GaN for high brightness LED applications

  • Seong, Tae-Yeon
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2003년도 추계학술발표강연 및 논문개요집
    • /
    • pp.23-23
    • /
    • 2003
  • GaN-related semiconductors are of great technological importance for the fabrication of optoelectronic devices, such as blue and ultra violet light emitting diodes (LEDs), laser diodes, and photo-detectors. One of the most important applications of GaN-based LEDs is solid-state lighting, which could replace incandescent bulbs and ultimately fluorescent lamps. For solid-state lighting applications, the achievement of high extraction efficiency in LED structures is essential. For flip-chip LEDs (FCLEDS), the formation of low resistance and high reflective p-GaN contact is crucial. So far, a wide variety of different methods have been employed to improve the ohmic properties of p-type contacts to GaN. For example, surface treatments using different chemical solutions have been successfully used to produce high-quality ohmic contacts, Metallization schemes, such as Ta/Ti contacts to p-GaN, were also investigated. For these contacts, the removal of hydrogen atoms from the Mg atoms doped n the GaN was argued to be responsible for low contact resistances.

  • PDF

유리단 국소의치 환자에서 T-scan system을 이용한 중심교합시에 교합접촉 양상 연구 (COMPUTERIZED EVALUATION OF OCCLUSAL CONTACTS IN CENTRIC CLOSURE IN DISTAL EXTENSION PARTIAL DENTURE CASES)

  • 이호용
    • 대한치과보철학회지
    • /
    • 제30권4호
    • /
    • pp.565-573
    • /
    • 1992
  • This clinical study was to analyze occlusal contacts in maximum intercuspation on distal extension partial denture and to compare tooth contact state between the denture teeth and abutment teeth by time mode and force mode using the T-scan system. The subjects ware twenty-one adult patients with upper natural teeth and lower distal extension partial denture. Conclusion : 1. The patient with simultaneous occlusal contacts both denture tooth and abutment and bilaterally in Kennedy Class I cases was one-sixth, but there was no one with symmetric occlusal and equal force among bilateral denture teeth and abutments. 2. The five-fifteenth of Kennedy Class I case patients resulted in simultaeous occlusal contacts bet-ween denture teeth and abutments but no one has the symmetric occlusal contacts and unifarm force between denture teeth and abutment teeth.

  • PDF

대용량(50kA)의 Making Switch와 Back Up Breaker 접점 개발에 따른 검증시험의 연구 (The Study of the Verification Test for Development of Contacts(50kA) of Making Switch and Back Up Breaker)

  • 김선구;김원만;나대열;노창일;이동준;정흥수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.842-844
    • /
    • 2004
  • The Back Up Breaker and Making Switch are very important equipments for the short circuit test facility, and contacts are the most important parts of the above switches. There are very many kind of contacts according to switches characteristic and should be done the verification test before use, especially development contacts. This study describes the class of switches, arc chute, material of whole contacts and essential test for verification. The essential test for verification are dielectric test, mechanical operation test, short-time withstand current test, load current breaking test, and short-circuit making current test etc.

  • PDF

Cu/Ti(Ta)/NiSi 접촉의 열적안정성에 관한 연구 (A Study on the Thermal Stability of Cu/Ti(Ta)/NiSi Contacts)

  • 유정주;배규식
    • 한국재료학회지
    • /
    • 제16권10호
    • /
    • pp.614-618
    • /
    • 2006
  • The thermal stability of Cu/Ti(or Ta)/NiSi contacts was investigated. Ti(Ta)-capping layers deposited to form NiSi was utilized as the Cu diffusion barrier. Ti(Ta)/NiSi contacts was thermally stable upto $600^{\circ}C$. However when Cu/Ti(Ta)/NiSi contacts were furnace-annealed at $300{\sim}400^{\circ}C$ for 40 min., the Cu diffusion was found to be effectively suppressed, but NiSi was dissociated and then Ni diffused into the Cu layer to form Cu-Ni solutions. On the other hand, the Ni diffusion did not occur for the Al/Ti/NiSi system. The thermal instability of Cu/Ti(Ta)/NiSi contacts was attributed to the high heat of solution of Ni in Cu.

노인의 접촉·만남을 지원해 주는 근린환경 디자인 지표개발 (Development of Neighborhood Design Indicators for Supporting Casual Contacts and Meetings of Old Residents)

  • 오찬옥;김수영;장수지
    • 한국실내디자인학회논문집
    • /
    • 제23권2호
    • /
    • pp.30-39
    • /
    • 2014
  • Korean society is running fast toward a super aging society. This means that new solutions for new problems of aged people are needed. An important area to prove is the aging-friendly neighborhood environments supporting casual contacts and meetings of old residents. This study attempts to suggest neighborhood design indicators which support casual contacts and meetings of old residents. The subjects were 24 professionals who had studied on housing environment for the elderly. They answered through the on-line questionnaire. The questionnaire consisted of items which evaluate the appropriateness of classification of neighborhood area and the indicators of each area using 5-points Likert scale. Also open questions asking adding or eliminating areas or indicator and other opinions were included. On the basis of these answers, the aging-friendly neighborhood design indicators supporting contacts and meetings of old residents was developed. They are consisted of 7 areas in neighborhood and 60 indicators. Those areas were semi-public residential area, commercial area, cultural & educational area, health & medical area, park & green area, walkway, and public traffic facilities. This would be used to design the neighborhood environments that are aging-friendly and facilitating casual contacts and meetings of all residents, especially old residents.

초고압 SF6 가스 차단기 투입 시 아크접촉자 내전압 특성 연구 (Analysis of Withstand Voltage between Arc Contacts of High Voltage SF6 Gas Circuit Breaker n Making Operation)

  • 김인길;이주현;정형수;박재윤
    • 전기학회논문지
    • /
    • 제61권4호
    • /
    • pp.601-605
    • /
    • 2012
  • The non-controlled closing of High-voltage SF6 gas circuit breaker can cause transient current and overvoltage in the field. The controlled closing technology is an effective way to reduce transient current and voltage, prevent equipment failures, and improve power quality. For the development of controlled closing, it is obviously necessary to determine the withstand voltage between arc contacts of High-voltage SF6 gas circuit breaker in making operation. This paper focuses on decrease of pressure and density of SF6 gas that can affect withstand voltage between arc contacts in making operation. The dielectric strength between arc contacts could be improved by minimizing the decrement of pressure and density of SF6 gas obtained by simulation and test and moreover the rate of decrease of dielectric strength (RDDS) of arc contacts could be foreseen.

B형 간염의 가족집적성과 전파경로에 관한 연구 (Familial Clustering and Its Associated Factors in Carriers of Hepatitis B Surface Antigen)

  • 이정애;이명학
    • 농촌의학ㆍ지역보건
    • /
    • 제17권2호
    • /
    • pp.129-136
    • /
    • 1992
  • To evaluate the possible route of intrafamilial transmission among carriers of hepatitis B surface antigen ($HB_sAg$), epidemiologic and serologic data were obtained on 107 household contacts of 35 carriers of HBsAg and on 71 household contacts of 25 controls who were negative for serologic markers of hepatitis B virus. The HBsAg prevalence was 26.5% among the contacts of carriers compared to 0.0% among the contacts of controls. And the combined prevalence for all hepatitis markers was 48.5% among the contacts of carriers compared to 26.0% among the contacts of controls(p<0.05). Especially the offspring of carriers showed significantly higher risk in the combined prevalence for all hepatitis markers (p<0.05). There were no significant relationship between HBV infection and past history like acupuncture, transfusion, operation and tattooed. Factors associated with the risk of intrafamilial transmission of HBV were not found in the sharing of household articles such as razor, towel, drinking glass, nail clippers, toothbrush and tableware.

  • PDF

RCD 접점형태에 따른 산화특성 분석 (The Analysis of Oxidization Characteristics according to the shapes of RCD contacts)

  • 김동우;김향곤;길형준;한운기;최충석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.576-577
    • /
    • 2005
  • In this paper, the oxidization characteristics were analyzed according to the shapes of Residual Current Protective Device(RCD) contacts. RCD is an electrical safety device specially designed to immediately switch the electricity off when electric leakage is detected at a level harmful to a person using electrical equipment. The shapes of RCD contacts are a little bit different according to the models. When RCD is turned on, stationary and moving contact do not fit together. So, it can cause the increase of contact resistance. To discover the deterioration characteristics of RCD contacts by switching repetition, the contacts were analyzed by stereo microscope, Scanning Electron Microscope(SEM) and Energy Dispersive X-ray Spectrometer(EDS).

  • PDF

A Close Contact Tracing Method Based on Bluetooth Signals Applicable to Ship Environments

  • Qianfeng Lin;Jooyoung Son
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제17권2호
    • /
    • pp.644-662
    • /
    • 2023
  • There are still outbreaks of COVID-19 across the world. Ships increase the risk of worldwide transmission of the virus. Close contact tracing remains as an effective method of reducing the risk of virus transmission. Therefore, close contact tracing in ship environments becomes a research topic. Exposure Notifications API (Application Programming Interface) can be used to determine the encountered location points of close contacts on ships. Location points of close contact are estimated by the encountered location points. Risky areas in ships can be calculated based on the encountered location points. The tracking of close contacts is possible with Bluetooth technology without the Internet. The Bluetooth signal can be used to judge the proximity among detecting devices by using the feature that Bluetooth has a strong signal at close range. This Bluetooth feature makes it possible to trace close contacts in ship environments. In this paper, we propose a method for close contact tracing and showing the risky area in a ship environment by combining beacon and Exposure Notification API using Bluetooth technology. This method does not require an Internet connection for tracing close contacts and can protect the personal information of close contacts.