• 제목/요약/키워드: contact reduction

검색결과 719건 처리시간 0.022초

한방 치료 후 호전된 알레르기성 접촉피부염 치험 1례 (A Case of Allergic Contact Dermatitis Improved after Korean Medicine Treatment Administration)

  • 배효빈;윤화정;고우신
    • 한방안이비인후피부과학회지
    • /
    • 제31권2호
    • /
    • pp.123-132
    • /
    • 2018
  • Objectives : The purpose of this report is to know the effect of Korean medicine treatments on Allergic Contact Dermatitis. Methods : We treated a 63-years-old man patient with Allergic Contact Dermatitis on the left medial calf with Korean medicine. After Korean medical treatment for 26 days, we identified a reduction in size of erythema and loss of color fading, exudates and edema. We recorded pictures of changes on symptoms. Results & Conclusions : The symptoms of Allergic Contact Dermatitis were improved. Erythema, edema, exudate were lost. Thus Korean medicine treatments are effective on allergic contact dermatitis.

Approaches to Reduce the Contact Resistance by the Formation of Covalent Contacts in Graphene Thin Film Transistors

  • Na, Youngeun;Han, Jaehyun;Yeo, Jong-Souk
    • Applied Science and Convergence Technology
    • /
    • 제26권4호
    • /
    • pp.55-61
    • /
    • 2017
  • Graphene, with a carrier mobility achieving up to $140,000cm^2/Vs$ at room temperature, makes it an ideal material for application in semiconductor devices. However, when the metal comes in contact with the graphene sheet, an energy barrier forms at the metal-graphene interface, resulting in a drastic reduction of the carrier mobility of graphene. In this review, the various methods of forming metal-graphene covalent contacts to lower the contact resistance are discussed. Furthermore, the graphene sheet in the area of metal contact can be cut in certain patterns, also discussed in this review, which provides a more efficient approach to forming covalent contacts, ultimately reducing the contact resistance for the realization of high-performance graphene devices.

고전압 임펄스를 활용한 발전용수 칼슘농도 저감에 관한 연구 (A Study on Calcium Ion Reduction in Power Plant Water using High Voltage Impulse)

  • 김태희;장인성;정재환;홍웅기;이준호
    • 전기학회논문지
    • /
    • 제66권3호
    • /
    • pp.545-550
    • /
    • 2017
  • As an alternate technique for water softening, high voltage impulse (HVI) is introduced and verified if it can control the $CaCO_3$ scale formation in industrial water treatment. After HVI was applied to the artificial hard water containing $100{\pm}5mg/L$ $Ca^{2+}$ for 4 hours, the $Ca^{2+}$ concentration and the electrical conductivity were measured. The concentration of $Ca^{2+}$ was reduced from 94.5 to 86.3 mg/L (8.7% reduction) after 4 hour contact of HVI under 5 kV condition. The $Ca^{2+}$ was decreased from 92 to 77.7 mg/L (15.6% reduction) at 8kV and from 90.1 to 75.4 mg/L (16.3% reduction) at 12 kV condition. Both of the contact time and the applied voltage were important parameters affecting the calcium ion reduction. With these results, it was verified that HVI technique could be potential candidate for control of $CaCO_3$ scale formation.

Stepwise Ni-silicide Process for Parasitic Resistance Reduction for Silicon/metal Contact Junction

  • Choi, Hoon;Cho, Il-Whan;Hong, Sang-Jeen
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권4호
    • /
    • pp.137-142
    • /
    • 2008
  • The parasitic resistance is studied to silicon/metal contact junction for improving device performance and to lower contact/serial resistance silicide in natural sequence. In this paper constructs the stepwise Ni silicide process for parasitic resistance reduction for silicon/metal contact junction. We have investigated multi-step Ni silicide on SiGe substrate with stepwise annealing method as an alternative to compose more thermally reliable Ni silicide layer. Stepwise annealing for silicide formation is exposed to heating environment with $5^{\circ}C/sec$ for 10 seconds and a dwelling for both 10 and 30 seconds, and ramping-up and the dwelling was repeated until the final annealing temperature of $700\;^{\circ}C$ is achieved. Finally a direct comparison for single step and stepwise annealing process is obtained for 20 nm nickel silicide through stepwise annealing is $5.64\;{\Omega}/square$ at $600\;^{\circ}C$, and it is 42 % lower than that of as nickel sputtered. The proposed stepwise annealing for Ni silicidation can provide the least amount of NiSi at the interface of nickel silicide and silicon, and it provides lower resistance, higher thermal-stability, and superior morphology than other thermal treatment.

사묘용안탕(四妙勇安湯) 물추출물이 DNCB로 유발된 접촉성피부염에 미치는 영향 (Effect of Samyoyongantang on Contact Hypersensitivity induced by Repeat Elicitation of DNCB.)

  • 변성희;이병욱;김상찬
    • 대한한의학방제학회지
    • /
    • 제13권2호
    • /
    • pp.59-69
    • /
    • 2005
  • Samyoyongantang (SMY), a herbal medicine, has been used as cure for gangrene. To evaluate anti-inflammatory effect of samyoyongantang, we treated samyoyongantang extract in animal model system induced contact hypersensitivity. Contact hypersensitivity, a local inflammatory response of the skin, was induced by 1% DNCB on the right ear of BALB/c mouse. Samyoyongantang was prepared as water extract and administrated everyday for 2 weeks per oral. A right ear of mouse was potently swelled by 1% of DNCB treatm ent, but a mouse ear thickness was significantly reduced by samyoyongantang after 2 we eks treatment. Samyoyongantang reduced IgG in serum obtained from blood of 1 % DNCB-treated mouse. IgE in serum was not changed by samyoyongantang treatment. From these results, anti-inflammatory effect of samyoyongantang, especially reduction of ear swell ing, might be partly due to reduction of IgG in serum.

  • PDF

Effect of stacking sequence of the bonded composite patch on repair performance

  • Beloufa, Hadja Imane;Ouinas, Djamel;Tarfaoui, Mostapha;Benderdouche, Noureddine
    • Structural Engineering and Mechanics
    • /
    • 제57권2호
    • /
    • pp.295-313
    • /
    • 2016
  • In this study, the three-dimensional finite element method is used to determine the stress intensity factor in Mode I and Mixed mode of a centered crack in an aluminum specimen repaired by a composite patch using contour integral. Various mesh densities were used to achieve convergence of the results. The effect of adhesive joint thickness, patch thickness, patch-specimen interface and layer sequence on the SIF was highlighted. The results obtained show that the patch-specimen contact surface is the best indicator of the deceleration of crack propagation, and hence of SIF reduction. Thus, the reduction in rigidity of the patch especially at adhesive layer-patch interface, allows the lowering of shear and normal stresses in the adhesive joint. The choice of the orientation of the adhesive layer-patch contact is important in the evolution of the shear and peel stresses. The patch will be more beneficial and effective while using the cross-layer on the contact surface.

자동차용 강판의 표면 마찰 특성에 대한 접촉 압력의 영향 (Contact Pressure Effect on Frictional Behavior of Sheet Steel for Automotive Stamping)

  • 한수식
    • 소성∙가공
    • /
    • 제20권2호
    • /
    • pp.99-103
    • /
    • 2011
  • Many parameters influence the frictional behavior of steel sheet during stamping. The contact pressure between a die and a sheet during stamping is one of them. Thus, this parameter is investigated for high strength steel (HSS) sheets, which are widely used for auto body panels due to their potential for weight reduction. Since HSS extend the limits of contact pressure for mild steel, the effect of this parameter on friction cannot be ignored. To investigate the influence of contact pressure on the frictional behavior of steel sheets, a flat type of friction test was conducted on three different steel sheets under various contact pressures. For bare steel sheets, the curve representing the relationship between contact pressure and friction coefficient exhibits a U shape. Coated steel sheets show a similar tendency except at low contact pressure. For these materials, when the contact pressure is very low, the friction coefficient slightly increases with pressure before it starts to decrease. The test results show that the effect of contact pressure on frictional behavior of steel sheet is not negligible even for contact pressures that are lower than the strength of HSS sheet.

Optimal Shape of Blunt Device for High Speed Vehicle

  • Rho, Joo-Hyun;Jeong, Seongmin;Kim, Kyuhong
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제17권3호
    • /
    • pp.285-295
    • /
    • 2016
  • A contact strip shape of a high speed train pantograph system was optimized with CFD to increase the aerodynamic performance and stability of contact force, and the results were validated by a wind tunnel test. For design of the optimal contact strip shape, a Kriging model and genetic algorithm were used to ensure the global search of the optimal point and reduce the computational cost. To enhance the performance and robustness of the contact strip for high speed pantograph, the drag coefficient and the fluctuation of the lift coefficient along the angle of attack were selected as design objectives. Aerodynamic forces were measured by a load cell and HWA (Hot Wire Anemometer) was used to measure the Strouhal number of wake flow. PIV (Particle Image Velocimetry) was adopted to visualize the flow fields. The optimized contact strip shape was shown a lower drag with smaller fluctuation of vertical lift force than the general shaped contact strip. And the acoustic noise source strength of the optimized contact strip was also reduced. Finally, the reduction amount of drag and noise was assessed when the optimized contact strip was applied to three dimensional pantograph system.

의치온성시 발생하는 교합 및 수직고경 변화에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON OCCLUSAL AND VERTICAL CHANGES AFTER DENTURE PROCESSING)

  • 김기성;김창회
    • 대한치과보철학회지
    • /
    • 제28권2호
    • /
    • pp.77-90
    • /
    • 1990
  • The purpose of this study was to compare the amount of the vertical pin opening of $33^{\circ}$ resin and $0^{\circ}$ resin teeth during processing and to determine whether the changes in tooth contacts by using articulation ribbon and T-Scan system follow any identifiable pattern, and to determine if there is any correlation between the changes in tooth contacts and the amount of the vertical pin opening after processing. Through statistical analyses on the data from this study, the following conclusions were obtained. 1. The amounts of the vertical pin opening were 0.78m, 0.87mm for $0^{\circ}$ teeth and $33^{\circ}$ teeth, respectively. But there was no significant difference between them. 2. The total number of contact points recorded by articulating ribbon after processing was decreased to 442.5% of that before processing. 3. The mean values for the number of contact points per tooth recorded by articulating ribbon after processing were 4.3 for the second molar, 3.8 for the first molar, 1.3 for the second premolar, 0.8 for the first premolar. The reduction of contact points per tooth became greater moving in an anterior direction. 4. The correlation between the reduction of contact points and the amount of the pin opening after processing was not significant. 5. The mean values for the numbers of contact points per tooth recorded by T-Scan system after processing were 2.2, 2.5, 1.0, and 0.5 at the second molar, the first molar, the second premolar, and the first premolar, respectively. 6. The correlation between the number of contact points by using articulating ribbon and TScan system after processing was not significant.

  • PDF

고전압 임펄스 기술을 활용한 경도 제거에서 경수의 초기부피와 인가시간이 칼슘이온 농도에 미치는 영향 (Effect of Initial Volume of Hard Water and Contact Time on the Reduction of Calcium Ion Concentration using High Voltage Impulse Technique)

  • 조승연;김태희;장인성;홍웅기;이준호
    • 전기학회논문지
    • /
    • 제66권7호
    • /
    • pp.1066-1071
    • /
    • 2017
  • Recently high voltage impulse (HVI) technique has been extensively studied for desalting processes to control the $CaCO_3$ scale formation in industrial water practices such as power plant, boiler, and heat exchange operations. Investigation of the operational parameters for the HVI is important, however, those had not been reported yet. In this study, the effect of initial feed volume and contact time on reduction of calcium ion concentration by the HVI technique was investigated. Initial feed volumes of artificial hard water which contained 100 mg/L of $Ca^{2+}$, were set to 1, 2, and 3 L respectively. After 24hr of HVI contact with 12kV, $Ca^{2+}$ ion was reduced to 50, 29 and 19 % of their initial concentration, indicating that calcium removal increased as initial feed volume decreased. This implies the applied HVI pulse energy per unit mass of calcium is important parameter determining overall desalting efficiency. A series of extended operations of HVI up to 30 days verified the long term stability of the HVI system. The calcium ion declined to 40 mg/L after 2~3 days, and further reduction of calcium was not achieved, indicating that optimum operation time could be 2~3 days under these experimental conditions. Consequently, it was confirmed that the important operational parameter of HVI technique is initial feed volume and contact time as well as the applied voltage that was already proven in the previous study.