• Title/Summary/Keyword: consumption efficiency

Search Result 2,997, Processing Time 0.028 seconds

Heat Balance during the Electrowinning of Neodymium Metal in Molten Salt (네오디뮴 금속의 전해 채취 중의 열수지)

  • Cho, Sung-Wook;Yu, Jeong-Hyun;Choi, Ho-Gil
    • Resources Recycling
    • /
    • v.31 no.3
    • /
    • pp.81-87
    • /
    • 2022
  • Energy consumption per unit weight of metal (kwh/kg of metal) is one of the most important economic indicators in the process of molten salt electrolysis. It is related to the heat loss of salt bath and the current efficiency of the process. The current efficiency is highly dependent on electrolysis temperature. On the other hand, the temperature of salt bath may increase significantly due to the difference (larger energy input than consumption) in heat balance at the beginning of electrolysis, which may cause different electrolysis temperature from an initially targeted value. This results in a bad effect on current efficiency. Therefore, it will be helpful to the reduction of energy consumption to compare the calculated and measured values of the temperature change of salt bath through the heat balance review at the early stage of electrolysis and to evaluate the energy loss to outside. In this study, based on the authors' experimental data, the heat balance was reviewed at the beginning of the electrolysis, and it was possible to evaluate the energy loss to the outside and the increase of the temperature of the salt bath quantitatively. Through such a method, heat loss reduction plan can be derived and current efficiency can be improved so that energy consumption can be reduced.

Study on the Exhaust Heat Recovery Equipment in a Factory - On the Performance of a U-shape Multitube Heat Exchanger - (공장폐열(工場廢熱) 회수장치(回收裝置)에 관한 연구(硏究) -U자형(字型) 다관식(多管式) 열교환기(熱交換機)의 성능(性能)에 관하여-)

  • Kim, Yung Bok;Song, Hyun Kap
    • Journal of Biosystems Engineering
    • /
    • v.8 no.2
    • /
    • pp.49-61
    • /
    • 1983
  • U shape multitube heat exchanger was equipped in the flue to recover the exhaust heat from the boiler system. The fluids of the exhaust heat recovery equipment were the flue gas as the hot fluid, and the water as the cold fluid. The flow geometry of the fluids was cross flow - two pass, the hot fluid being mixed and the cold fluid unmixed. The results of the theoretical and the experimental analysis and the economic evaluation are summarized as follows. 1) The heat exchanger effectiveness and the temperature efficiency of the hot fluid were about 35% when the fuel consumption rate was 140 - 150 L/15min. The temperature efficiency for the cold fluid ranged from 3.0% to 4.5%. The insulation efficiency ranged from 85% to 98%, which was better than the KS air preheater insulation efficiency of 90%. 2) The relationship between the fuel consumption rate, F, and the outlet temperature, $T_{h2}$, of the flue gas from the heat exchanger was $T_{h2}$ = 0.927F + 110. In order to prevent the low temperature corrosion from the coagulation of $SO_3$, it is necessary to maintain the fuel consumption rate above 82 L/15min. 3) The ratio of the exhaust heat from the boiler system to the total energy consumption was about 14.5%. With the installation of the exhaust heat recovery equipment, the energy recovery ratio to the exhaust heat was about 25%. Accordingly, about 3.6% of the total fuel consumption was estimated to be saved. 4) Economic analysis indicated that the installation of the exhaust heat recovery equipment was feasible to save the energy, because the capital reocvery period was only 10 months when the fuel consumption rate was 80 L/15min. 4 months when it was 160 L/15min. 5) Based on the theoretical and the experimental analysis, it was estimated to save the energy of about 18 million Won per year, if four heat exchangers are installed in a factory. 6) A further study is recommended to identify the relationship among the flow rate of the exhaust gas, the size of the heat exchanger and the capacity of the air preheater. For a maximum heat recovery from the exhaust gas an automatic control system is required to control the flow rate of the cold fluid depending on the boiler load.

  • PDF

The Study on Reduction Method of CO2 Emission from Ships (선박에서의 CO2 배출량 저감 방안 연구)

  • Maeda, Kazuyuki;Kim, Young-Un
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.25 no.3
    • /
    • pp.705-715
    • /
    • 2013
  • This Paper presented the reduction methods of $CO_2$ emission from ships during voyage. In order to decrease $CO_2$ emission during voyage the equation was established and conducted the study about the relationship between ship speed, the propulsive efficiency and its $CO_2$ production. The results obtained from the examinations are as follows : 1. $CO_2$ emission from sailing ships can be decreased by reducing specific fuel oil consumption of main diesel engine, coefficient of total resistance and ship speed and also by increasing propeller efficiency. 2. Diesel-electric propulsion system is more effective than diesel-mechanical system to decrease the level of $CO_2$ emission during long voyage. 3. Good condition of ship's hull surface, rudder and propeller's surface can decrease the quantity of fuel oil and $CO_2$ emission by reducing the resistance of ship that can rise the propeller efficiency 4. $CO_2$ emitted from ships can be decreased in a global scale by giving attention to the synthetic transport efficiency.

Study on Industrial Inverters for Driving High-efficiency High-voltage Field-stop IGBT Optimization Design (산업용 인버터 구동을 위한 고효율 고내압 Field-stop IGBT 최적화 설계에 관한 연구)

  • Lee, Myung Hwan;Kim, Bum June;Jung, Eun Sik;Jung, Hun Suk;Kang, Ey Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.4
    • /
    • pp.257-263
    • /
    • 2013
  • In this paper, Solar, Wind, fuel cell used in a Power conversion devices and industrial inverter motor to increase the efficiency of energy consumption, which is a core part of high-efficiency, high-voltage Trench Gate Field Stop IGBT was studied. For this purpose Planar type NPT IGBT and Planar type Field Stop IGBT have designed a basic structure designed to Trench Gate Field Stop IGBT based on the completed structure by analyzing the energy consumption of electrical characteristics, efficiency is a key part, high-efficiency and high-voltage inverter for industry regarding the optimization design for Trench Gate Field Stop IGBT.

Estimating Potential Energy Consumption and Carbon Emission Reduction in South Korea Using Non-radial Data Envelopment Analysis Approach (Non-radial Data Envelopment Analysis를 적용한 지역별 에너지 및 이산화탄소 저감가능성 추정)

  • Kim, Kwang-Uk;Kang, Sang-Mok
    • Environmental and Resource Economics Review
    • /
    • v.25 no.2
    • /
    • pp.299-320
    • /
    • 2016
  • This study estimates an energy efficiency of 16 metropolitans and provinces in Korea, and measures potential energy-saving and carbon emission reduction using a non-radial data envelopment analysis method. Based on energy mix scenarios, this study also evaluates the impact of changes in energy structural adjustment on a regional environmental performance. The empirical results show that, on average, 12.70% of energy consumption and 13.73% of carbon emission can be reduced by improvement in energy efficiency, and low efficiency of oil usage in metropolitan cities is a major source of the inefficiency. Furthermore, it is found that energy mix policy should be considered to achieve an extra energy-saving and carbon reduction.

Food Consumption and Utilization Efficiency in Samia ricini Donovan Reared on Ricinus communis, lin. Leaves Supplemented with Cyanobacteria

  • Sujatha, K.;Jaikishan Singh, R.S.;Sampath, A.;sanjeeva Rao, B.V.
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.28 no.2
    • /
    • pp.32-38
    • /
    • 2014
  • Food consumption and conversion efficiency of eri silkworm Samia ricini Donovan were studied during $4^{th}$ and $5^{th}$ larval instars by feeding castor leaves fortified with 100, 200, 300, 400 and 500 ppm concentrations of aqueous extracts of cyanobacteria Anabaena variabilis. The nutritional indices viz., ingesta, digesta, approximate digestibility (%), reference ratio and efficiency parameters like ECI and ECD were recorded which were significantly high at 400 ppm concentration treated batches of $4^{th}$ instar larvae over control batches. The decline in nutritional efficiency parameters of $5^{th}$ instar treated larvae might be due to higher utilization of the digested food for metabolic activities. Significant difference of ECI to cocoon % and non-significant difference of ECD to cocoon% and shell were observed between the treatments and control. Cyanabacteria feed supplement contains antibiotic and nutritions factors which has reflective effect on the biological parameters in eri silkworm and therefore has greater application in commercial eri silkworm rearing.

A Study on the Influence of Test Temperature & Cooling Fan Condition on the Fuel Test of Diesel Vehicle (디젤차량 연비시험에 있어 시험온도 및 냉각팬 조건이 미치는 영향분석에 관한 연구)

  • Kim, Hyun-Jin;Kim, Sung-Woo;Lim, Jae-Hyuk;Noh, Kyung-ha;Lee, Jung-Cheon;Kim, Ki-Ho;Oh, Sang-Gi
    • Journal of Power System Engineering
    • /
    • v.21 no.6
    • /
    • pp.46-55
    • /
    • 2017
  • Due to the arise of natural disasters caused by global warming, consumers have more interest in the fuel efficiency of their vehicles, and fuel efficiency became an important factor in comparing vehicles. In this market situation, methods to measure fuel efficiency has become one of the main interests of vehicle related organizations and laboratories, and the current method to measure fuel efficiency is to follow the notification established by the ministry of trade, industry and energy, ministry of environment, and the ministry of land, infrastructure and transport. In this study, we analyze the influence of vehicle fuel efficiency according to test temperature and cooling fan condition which have the possibility to cause difference in fuel efficiency. The analysis results of the influence of the fuel efficiency according to the test temperature, the difference of the fuel efficiency of the test temperature ($21{\sim}29^{\circ}C$) within the allowable range of the notification showed a maximum difference of 2.9%. Therefore, it is necessary to consider the introduction of a test method that permits only the temperature change based on the reference point as the allowable range even in the test within the allowable range. The analysis of the influence of the fuel efficiency according to the cooling method showed no significant effect, and it seems reasonable to maintain the test method of the current notification.

Comparison of Energy Efficiency by Production Frontier Approach: Based on OECD Countries (생산 프론티어 접근을 통한 에너지효율 비교: OECD 국가를 중심으로)

  • Kang, Sangmok;Kim, Haechang
    • Environmental and Resource Economics Review
    • /
    • v.20 no.1
    • /
    • pp.33-60
    • /
    • 2011
  • The purpose of the article is to compare the impacts of energy efficiency and economic growth for energy demand through production frontier approach in OECD countries. We compared the traditional energy intensity with energy efficiencies of production frontier approach, slack efficiency on the frontier, and estimated elasticity of energy demand for GDP growth. First, the energy intensity has a low relationship with energy efficiency by radial approach, but has constant correlations with slack energy efficiency, slack-adjusted efficiency by non-radial approach, and energy efficiency by horizon approach. If we measure energy efficiency only with energy elasticity, it may make a mistake. Especially the energy efficiency by radial approach has a tendency to overestimate most OECD countries. Second, as many countries have excess energy consumption of 17.3% even on the points of the frontier, reduction of energy consumption is necessary in addition. Third, the average energy elasticity of OECD countries is 1.1 close to elasticity 1. There exists the difference of elasticity among countries and the energy demands are also high in countries with high elasticity.

  • PDF

Estimation methods of fuel consumption using distance traveled: Focused on Monte Carlo method (주행거리를 이용한 연료소비량 산정방법: 몬테카를로 기법 중심으로)

  • Park, Chun-Gun;Soh, Jin-Young;Lee, Yung-Seop
    • Journal of the Korean Data and Information Science Society
    • /
    • v.23 no.2
    • /
    • pp.247-256
    • /
    • 2012
  • Recently, estimation of greenhouse gas (GHG) emission has continuously emerged as an important global issue. This study compares various statistical methods for estimation of fuel consumption, which is necessary for calculation of GHG emission in road transportation sector. Existing methods have focused on using merely transportation fuel supply or distance traveled for calculation of fuel consumption. Estimates of GHG emission based on fuel supply, however, cannot reflect various vehicle types or model year. This study suggests and compares, from statistical point of view, several methods, which can be applied to estimate fuel consumption of each vehicle, by combining distance traveled and fuel efficiency (mileage), and total fuel consumption of all vehicles. It also suggests practical measures that can reflect vehicle types and model year to suggested methods for future research.

A Study on Energy Usage Monitoring and Saving Method in the Sewage Treatment Plant (공공하수처리시설에서 에너지 사용현황 및 절감방안 연구)

  • Kim, Jongrack;Rhee, Gahee;You, Kwangtae;Kim, Dongyoun;Lee, Hosik
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.6
    • /
    • pp.535-545
    • /
    • 2020
  • This study aims to conserve and monitor energy use in public sewage treatment plants by utilizing data from the SCADA system and by controlling the aeration rate required for maintaining effluent water quality. Power consumption in the sewage treatment process was predicted using the equipment's uptime, efficiency, and inherent power consumption. The predicted energy consumption was calibrated by measured data. Additionally, energy efficiency indicators were proposed based on statistical data for energy use, capacity, and effluent quality. In one case study, a sewage treatment plant operated via the SBR process used ~30% of energy consumed in maintaining the bioreactors and treated water tanks (included decanting pump and cleaning systems). Energy consumption analysis with the K-ECO Tool-kit was conducted for unit processing. The results showed that about 58.7% of total energy consumed was used in the preliminary and biological treatment rotating equipment such as the blower and pump. In addition, the energy consumption rate was higher to the order of 19.2% in the phosphorus removal process, 16.0% during sludge treatment, and 6.1% during disinfection and discharge. In terms of equipment energy usage, feeding and decanting pumps accounted for 40% of total energy consumed following 27% for blowers. By controlling the aeration rate based on the proposed feedback control system, the DO concentration was reduced by 56% compared pre-controls and the aeration amount decreased by 28%. The overall power consumption of the plant was reduced by 6% via aeration control.