• Title/Summary/Keyword: consumption area

Search Result 2,363, Processing Time 0.029 seconds

Efficient Transmission Structure and Key Management Mechanism Using Key Provisioning on Medical Sensor Networks (의료 센서 네트워크에서의 효율적인 전송 구조 및 Key Provisioning을 사용한 키 관리 기법 연구)

  • Seo, Jae-Won;Kim, Mi-Hui;Chae, Ki-Joon
    • The KIPS Transactions:PartC
    • /
    • v.16C no.3
    • /
    • pp.285-298
    • /
    • 2009
  • According to the development of ubiquitous technologies, sensor networks is used in various area. In particular, medical field is one of the significant application areas using sensor networks, and recently it has come to be more important according to standardization of the body sensor networks technology. There are special characteristics of their own for medical sensor networks, which are different from the one of sensor networks for general application or environment. In this paper, we propose a hierarchical medical sensor networks structure considering own properties of medical applications, and also introduce transmission mechanism based on hierarchical structure. Our mechanism uses the priority and threshold value for medical sensor nodes considering patient's needs and health condition. Through this way Cluster head can transmit emergency data to the Base station rapidly. We also present the new key establishment mechanism based on key management mechanism which is proposed by L. Eschenauer and V. Gligor for our proposed structure and transmission mechanism. We use key provisioning for emergency nodes that have high priority based on patients' health condition. This mechanism guarantees the emergency nodes to establish the key and transmit the urgent message to the new cluster head more rapidly through preparing key establishment with key provisioning. We analyze the efficiency of our mechanism through comparing the amount of traffic and energy consumption with analysis and simulation with QualNet simulator. We also implemented our key management mechanism on TmoteSKY sensor board using TinyOS 2.0 and through this experiments we proved that the new mechanism could be actually utilized in network design.

The Control System of Wood Pellet Boiler Based on Home Networks (홈 네트워크 기반의 펠릿 활용 난방 보일러 제어시스템)

  • Lee, Sang-Hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.15 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • This paper presents the implementation of a control system of pellet boiler using wood pellet as carbon neutral material. The system also has the additional features to provide remote controlling and monitoring based on home networking technology through either public switched telephone networks or mobile communication networks. It consists of three kinds of sub-modules; a main controller provides basic and additional features such as a setting of temperature, a supplying of wood pellet, a controlling of ignition and fire-power, and a removing of soot. The second is temperature controller of individual rooms which is connected to the main controller through RS-485 links. And interface modules with PSTN and mobile networks can support remote controlling and monitoring the functions. The test results under the heating area of $172m^2$ show a thermal efficiency of 93.6%, a heating power of 20,640kcal/hr, and a fuel consumption of 5.54kg/hr. These results are superior to those of the conventional pellet boilers. In order to obtain the such high performance, we newly applied a 3-step ignition flow, a flame detection by $C_dS$ sensor, and a fire-power control by fine controlling of shutter to our pellet boiler.

Heat Recovery Characteristics of the Hot Water Supply System with Exhaust Heat Recovery Unit Attached to the Hot Air Heater for Plant Bed Heating in the Greenhouse (온풍난방기의 배기열을 이용한 지중 난방용 온수공급시스템의 열회수특성)

  • 김영중;유영선;장진택;강금춘;이건중;신정웅
    • Journal of Biosystems Engineering
    • /
    • v.25 no.3
    • /
    • pp.221-226
    • /
    • 2000
  • Hot air heater with light oil burner is the most common heater for greenhouse heating in the winter season in Korea. However, since the thermal efficiency of the heater is about 80∼85%, considerable unused heat amount in the form of exhaust gas heat discharges to atmosphere. In order to capture this exhaust heat a heat recovery system for plant bed heating in the greenhouse was built and tested in the hot air heating system of greenhouse. The heat recovery system is made for plant bed or soil heating in the greenhouse. The system consisted of a heat exchanger made of copper pipes, ${\Phi}12.7{\times}0.7t$ located in the rectangular column of $330{\times}330{\times}900mm$, a water circulation pump, circulation plastic pipe and a water tank. The total heat exchanger area is 1.5$m^2$, calculated considering the heat exchange amount between flue gas and water circulated in the copper pipes. The system was attached to the exhaust gas path. The heat recovery system was designed as to even recapture the latent heat of flue gas when exposing to low temperature water in the heat exchanger. According to the performance test it could recover 45,200 to 51,000kJ/hr depending on the water circulation rates of 330 to $690\ell$/hr from the waste heat discharged. The exhaust gas temperature left the heat exchanger dropped to $100^{\circ}C$ from $270^{\circ}C$ by the heat exchange between the water and the flue gas, while water gained the difference and temperature increased to $38^{\circ}C$ from $21^{\circ}C$ at the water flow rate of $690\ell$/hr. By the feasibility test conducted in the greenhouse, the system did not encounter any difficulty in operations. And, the system could recover 220,235kJ of exhaust gas heat in a day, which is equivalent of 34% of the fuel consumption by the water boiler for plant bed heating of 0.2ha in the greenhouse.

  • PDF

PERFORMANCE OF FIMS MICROCHANNEL PLATE DETECTOR SYSTEM (FIMS의 마이크로채널 플레이트 검출기 시스템의 특성)

  • Nam, U.W.;Rhee, J.G.;Kong, K.N.;Park, Y.S.;Jin, K.C.;Jin, H.;Park, J.H.;Yuk, I.S.;Seon, K.I.;Han, W.;Lee, D.H.;Ryu, K.S.;Min, K.W.;Edelstein, J.;Korpela, E.
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.4
    • /
    • pp.273-282
    • /
    • 2002
  • We describe some performance of the detector electronics system for the FIMS (Far-ultraviolet Imaging Spectrograph) mission. The FIMS mission to map the far ultraviolet sky uses MCP (micro-channel plate) detectors with a crossed delay line anode to record photon arrival events. FIMS has two MCP detectors, each with a ~25mm$\times$25mm active area. The unconventional anode design allows for the use of a single set of position encoding electronics for both detector fields. The centroid position of the charge cloud, generated by the photon-stimulated MCP, is determined by measuring the arrival times at both ends of the anode following amplification and external delay. The temporal response of the detector electronics system determines the readout's positional resolution for the charge centroid. High temporal resolution (<$35{\times}75$ps FWHM) and low power consumption (< 6W) were achieved for the FIMS detector electronics system.

A Design of Memory-efficient 2k/8k FFT/IFFT Processor using R4SDF/R4SDC Hybrid Structure (R4SDF/R4SDC Hybrid 구조를 이용한 메모리 효율적인 2k/8k FFT/IFFT 프로세서 설계)

  • 신경욱
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.430-439
    • /
    • 2004
  • This paper describes a design of 8192/2048-point FFT/IFFT processor (CFFT8k2k), which performs multi-carrier modulation/demodulation in OFDM-based DVB-T receiver. Since a large size FFT requires a large buffer memory, two design techniques are considered to achieve memory-efficient implementation of 8192-point FFT/IFFT. A hybrid structure, which is composed of radix-4 single-path delay feedback (R4SDF) and radix-4 single-path delay commutator (R4SDC), reduces its memory by 20% compared to R4SDC structure. In addition, a memory reduction of about 24% is achieved by a novel two-step convergent block floating-point scaling. As a result, it requires only 57% of memory used in conventional design, reducing chip area and power consumption. The CFFT8k2k core is designed in Verilog-HDL, and has about 102,000 Bates, RAM of 292k bits, and ROM of 39k bits. Using gate-level netlist with SDF which is synthesized using a $0.25-{\um}m$ CMOS library, timing simulation show that it can safely operate with 50-MHz clock at 2.5-V supply, resulting that a 8192-point FFT/IFFT can be computed every 164-${\mu}\textrm{s}$. The functionality of the core is fully verified by FPGA implementation, and the average SQNR of 60-㏈ is achieved.

Active-RC Channel Selection Filter with 40MHz Bandwidth and Improved Linearity (개선된 선형성을 가지는 R-2R 기반 5-MS/s 10-비트 디지털-아날로그 변환기)

  • Jeong, Dong-Gil;Park, Sang-Min;Hwang, Yu-Jeong;Jang, Young-Chan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.1
    • /
    • pp.149-155
    • /
    • 2015
  • This paper proposes 5-MS/s 10-bit digital-to-analog converter(DAC) with the improved linearity. The proposed DAC consists of a 10-bit R-2R-based DAC, an output buffer using a differential voltage amplifier with rail-to-rail input range, and a band-gap reference circuit for the bias voltage. The linearity of the 10-bit R-2R DAC is improved as the resistor of 2R is implemented by including the turn-on resistance of an inverter for a switch. The output voltage range of the DAC is determined to be $2/3{\times}VDD$ from an rail-to-rail output voltage range of the R-2R DAC using a differential voltage amplifier in the output buffer. The proposed DAC is implemented using a 1-poly 8-metal 130nm CMOS process with 1.2-V supply. The measured dynamic performance of the implemented DAC are the ENOB of 9.4 bit, SNDR of 58 dB, and SFDR of 63 dBc. The measured DNL and INL are less than +/-0.35 LSB. The area and power consumption of DAC are $642.9{\times}366.6{\mu}m^2$ and 2.95 mW, respectively.

A 125 MHz CMOS Delay-Locked Loop with 32-phase Output Clock (32 위상의 출력 클럭을 가지는 125 MHz CMOS 지연 고정 루프)

  • Lee, Kwang-Hun;Jang, Young-Chan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.1
    • /
    • pp.137-144
    • /
    • 2013
  • A delay-locked loop (DLL) that generates a 32-phase clock with the operating frequency of 125 MHz is introduced. The proposed DLL uses a delay line of $4{\times}8$ matrix architecture to improve a differential non-linearity (DNL) of the delay line. Furthermore, a integral non-linearity (INL) of the proposed DLL is improved by calibrating phases of clocks that is supplied to four points of an input stage of the $4{\times}8$ matrix delay line. The proposed DLL is fabricated by using $0.11-{\mu}m$ CMOS process with a 1.2 V supply. The measured operating frequency range of the implemented DLL is 40 MHz to 280 MHz. At the operating frequency of 125MHz, the measurement results shows that the DNL and INL are +0.14/-0.496 LSB and +0.46/-0.404 LSB, respectively. The measured peak-to-peak jitter of the output clock is 30 ps when the peak-to-peak jitter of the input clock is 12.9 ps. The area and power consumption of the implemented DLL are $480{\times}550{\mu}m^2$ and 9.6 mW, respectively.

The study for the Epidemiologic Characteristics of Cancer Patients in Jeju Special Self-governing Province (제주특별자치도 암 환자의 역학적인 특성에 관한 연구)

  • Chang, Weon-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1292-1303
    • /
    • 2015
  • Jeju province is the highest area about obesity(1st), alcohol consumption(2nd) and male smoking(2nd) among sixteen Korean provinces by the report of Statistics Korea: 2013 community health survey. Therefore, it is assumed that the incidence rate of colon, liver, lung and breast cancer can be high. The purpose of this study is to test these cancer's incidence and mortality trends and compare comparability with national average. The Joinpoint regression model and permutation tests for identifying changes and parallelism in trend were used to test registered data at Jeju Regional Cancer Registry from 1999 to 2012. In male colorectal cancer, Average Age Percent Change(AAPC) of Age-Standardized incidence Rate(ASR) was 8.4% per year(p-value<.000) and the hypothesis of parallelism with Korean male average was rejected because of steep increasing of Jeju male patients' AAPC(p-value=.047). In male liver cancer, AAPC of ASR was -2.98 % per year(p-value<.000) and parallelism with Korean male average was rejected because of sluggish decreasing of Jeju(p-value=.026). In male lung cancer, the ASR parallelism with Korean male average was rejected(p-value=.009) because Jeju patients APC(4.37% per year) was increased during 2006~2012. This study demonstrates that AAPC and Trends of male colon, male lung and male liver were difference from national average. Further studies are needed to understand its causes.

A study on the concentration and health risk of trihalomethanes in drinking water (음용수중 Trihalomethane의 오염과 그 위해성에 관한 조사연구 - 주요 14개도시를 대상으로 (1988. 9-1989. 2) -)

  • Chung, Yong;Shin, Dong-Chun;Lee, Bo-Young;Yu, Sung-Han;Chung, Sang-Hyuk
    • Journal of Preventive Medicine and Public Health
    • /
    • v.22 no.4 s.28
    • /
    • pp.495-505
    • /
    • 1989
  • This study was conducted as a nationwide survey In Korea to determine the THM (trihalomethane) concentration levels in the drinking water of 14 selected cities. The survey was underdtaken in one city (Kwangju) during September and October of 1988 and 14 cities in January through February of 1989. The results were as follows : 1. The $KMnO_4$ consumption was 10.6mg/l-11.6mg/l in Pusan and Ulsan, exceeding the drinking water standard of 10mg/l. Pusan, Inchon, Kwangju, Ulsan, Mokpo and Junju areas also exceeded the ammonia nitrate standard of 0.5mg/l. Other tap waters surveyed were detected below the drinking water standards. 2. The THM concentrations of tap water measured in January and February of 1989 were detected in the range $1.20{\mu}g/l-150.8{\mu}g/l$. 3. In the comparative study of the THM concentration of tap water measured in the Kwangju area during September and October of 1998, the average THM concentation of $145.63{\pm}70.72{\mu}g/l$ showed a sixfold increase compared to that of $23.8{\pm}8.31{\mu}g/l$ surveyed in January and February 1989. 4. The proportion of the four THM compounds found in tap water was bromoform, 47% ; chloroform, 30% ; chlorodibromomethane, 13% ; and dichlorobromomethane, 10%. 5. Since the results indicate that the concentration of bromoform was 2-10 times higher than that of chloroform measured in the seaside district of Pusan, Ulsan and Cheju Island, it is reasonable to assume that the raw water was somehow Influenced by seawater. 6. The average lifetime cancer rate of the population exposed to chloroform measured in the surveyed areas was 17 cancer incidences per 1 million population. From the above results, the existence of THM in the distribution systems seems to be inevitable, since chlorine disinfection is performed in water treatment plants In our country. There seems to be a trend of increasing. THM cncentrations due to the contamination of raw water. In order to establish my form of regulations, health risk assessment is an imminent subject.

  • PDF

The Economic Impact of a Rural Hospital to Local Economy (한 병원이 지역사회에 미치는 경제적 영향 분석)

  • Kang, Im-Ok;Lee, Sun-Hee;Kim, Han-Joong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.4 s.55
    • /
    • pp.831-842
    • /
    • 1996
  • Demand for high quality medical care has recently been increasing in step with high level of income and education. Patients prefer the use of large general hospitals to small community hospitals. Large hospitals, usually located at urban area, expand their capacities to cope with the increasing demand, therefore, they easily secure revenue necessary for growth and development of hospitals. However, small community hospitals are facing with serious financial difficulties caused from the reduction of patients in one hand and the inflation of cost in another. If small rural hospitals were closed, the closure would have negative impacts on local economies in addition to the decrease in access to medical care. Community leaders should have an insight on the contribution of community hospitals to local economies. They could make a rational decision on the hospital closure only with the understanding of hospital's contribution to the community. This study is designed to develop an economic model to estimate the contribution of rural hospital to local economies, and also to apply this model with a specific hospital. The contribution of a hospital to local economies consists of two elements, direct effect and multiplier effects. The direct impacts include hospital's local purchasing power, employee's local purchasing power, and the consumption of patients coming from outside the community. The direct impact induces multiplication effect in the local economy. The seed money invested to other industries grows through economic activities in the region. This study estimated the direct effect with the data of expenditure of the case hospital. The total effect was calculated by multiplied the direct effect with a multiplier. The multiplier was drown from the ratio of marginal propensity of income and expenditure. Beside the estimation of the total impacts, the economic effect from the external resources was also analyzed by the use of the ratio of patients coming outside the region. The results are as follows. 1. The direct economic contribution of the hospital to the local economy is 1,104 million won. 2. The value of multiplier in the region is 2.976. 3. The total economic effect is 3,286 million won, and the multiplication effect is 2,182 million won. 4. The economic contribution from the external resources is 245 million won which is 7.5% of the total economic effect.

  • PDF