• 제목/요약/키워드: consumed electricity

검색결과 66건 처리시간 0.026초

생활폐기물 고형연료(RDF) 제조기술 경제성 평가 (An Economic Evaluation of MSW RDF Production Plant)

  • 최연석;최항석;김석준
    • 신재생에너지
    • /
    • 제7권1호
    • /
    • pp.29-35
    • /
    • 2011
  • The waste treatment fee and energy production effect of Wonju city RDF plant, the first RDF manufacturing plant in Korea, were investigated in the study. All plant operation data, like total weight of received wastes, produced RDF and separated rejects in processes were fully recorded for mass balance calculation of the plant in 2009. Also all consumed oil and electricity were recorded for energy balance calculation. The results showed that the waste treatment fee not including the RDF sales price of 25,000 won/ton-RDF was 116,573 won/ton-MSW and it went down to 105,298 won when included the RDF price. Produced RDF was 40.2% of total received waste in weight. Three components analysis by mass balance calculation of total received waste showed that Wonju city's MSW was 32.4% of combustible, 37.5% of water and 30.1% of incombustible respectively. Energy effect was found that total amount of produced energy was about 4 times more than that of consumed energy.

국내의 LED 교통신호등의 기술현황 분석연구 (Technical Status of LED Traffic Signals made in Korea)

  • 정학근;정봉만;한수빈;박석인;김규덕;유승원
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.171-174
    • /
    • 2004
  • Concerning Korean energy consumption, 20% of the total electrical energy (96% is now exported) is consumed in lighting area. Accordingly, it is one of the most important governmental policies to efficiently utilize electricity due to development and application of high-efficiency lighting equipment. In Korea, widely-built traffic signals employ an incandescent and are of 100W/300 mm, and 280,080set/801,932lamps have been installed and operated by 1999. Of them, 58%(161,181set), 25%(69,655set) and 18%(49,244set) correspond to traffic signals, pedestrian signals and other supplementary signals respectively. It was estimated that electrical energy consumed 28MW instantaneously, 245GWH annually. On the other hand, the LED traffic signal is expected to be a future traffic signal since if traffic signals are replaced by LEDs, energy saving effect of 85% and drop of 75% in maintenance fee will be obtained. In this paper, the performance and characteristics of many LED traffic signals made in Korea are summarized in order to reform Korean standard of LED traffic signals.

  • PDF

고효율 유도전동기 소형 모터코어 금형개발에 관한 연구 (A Study on Development of Small Motor Core Die for High Efficiency Induction Motor)

  • 임세종;김세환;최계광
    • 한국산학기술학회논문지
    • /
    • 제11권2호
    • /
    • pp.455-460
    • /
    • 2010
  • 고효율 유도전동기는 일반 유도전동기의 발생 손실을 절감시킨 것으로 적은 소비전력으로 에너지를 절약하고, 운전비용이 낮아서 단기간에 초기 설비투자 비용회수가 가능하고, 온도상승이 크지 않아 전동기 수명을 연장시킬 수 있다. 이에 포스코아에서는 이제까지의 경험을 바탕으로 전기 연구원과 협력하여 고효율 유도전동기 개발에 나섰다. 본 논문에서는 고효율 유도전동기 소형모터금형개발에 관하여 연구하였다.

Stochastics and Artificial Intelligence-based Analytics of Wastewater Plant Operation

  • Sung-Hyun Kwon;Daechul Cho
    • 청정기술
    • /
    • 제29권2호
    • /
    • pp.145-150
    • /
    • 2023
  • Tele-metering systems have been useful tools for managing domestic wastewater treatment plants (WWTP) over the last decade. They mostly generate water quality data for discharged water to ensure that it complies with mandatory regulations and they may be able to produce every operation parameter and additional measurements in the near future. A sub-big data group, comprised of about 150,000 data points from four domestic WWTPs, was ready to be classified and also analyzed to optimize the WWTP process. We used the Statistical Product and Service Solutions (SPSS) 25 package in order to statistically treat the data with linear regression and correlation analysis. The major independent variables for analysis were water temperature, sludge recycle rate, electricity used, and water quality of the influent while the dependent variables representing the water quality of the effluent included the total nitrogen, which is the most emphasized index for discharged flow in plants. The water temperature and consumed electricity showed a strong correlation with the total nitrogen but the other indices' mutual correlations with other variables were found to be fuzzy due to the large errors involved. In addition, a multilayer perceptron analysis method was applied to TMS data along with root mean square error (RMSE) analysis. This study showed that the RMSE in the SS, T-N, and TOC predictions were in the range of 10% to 20%.

FedEx Earth Smart: Practices of Environment-Friendly Management

  • Jung, Young-Su
    • 융합경영연구
    • /
    • 제3권4호
    • /
    • pp.21-27
    • /
    • 2015
  • With the recent increasing interest in sustainability management, the latest environmental report tends to be substituted by the expanded sustainability management report. In this work, I would like to introduce the management pattern of a global enterprise that values environmental soundness (environmental friendly) and implements eco-friendly measures. The enterprise chosen in this study is FedEx. In this article, FedEx case is presented how companies can adopt environmental friendly management in their businesses. FedEx has maintained an eco-friendly management since the introduction of the company's eco-friendly transport trucks in 2003, following its development in 2000. In 2005, it installed a solar power plant that can supply up to 80% of the electricity consumed by Oakland Logistics Center in California, USA. FedEx has published the "Global Enterprise Citizenship Report," which contains its business developments in 2009. FedEx has worked hard to minimize the influence caused by packaging of goods to the environment and appealed to customers to use recycled products as much as they can. FedEx also encourages customers to use packaging materials efficiently. A considerable amount of energy has been expended in the eco-friendly programs of FedEx. Although thousands of FedEx vehicles and aircraft operate daily with using large amounts of electricity and fuel, FedEx focuses on energy savings and global environment protection.

사무실 및 학교 교실의 조명용 소비전력량 절감방안 연구 (A Study on the Plan for Reducing Electricity Consumed to Light up in Offices and Classrooms)

  • 이광수;장우진
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.179-182
    • /
    • 2007
  • 현재 우리나라 대부분의 사무실 및 학교교실에는 형광등 스위치가 창측, 중간, 복도측등으로 회로가 분리되어 있으나 날씨가 맑고 태양빛이 많이 비치는 경우(기준조도 이상)에도 창측의 형광등이 항상 켜져 있는 경우가 대부분이므로 외부 쪽 창측에 설치되는 형광등기구에 외부광량(일조량)에 따라 자동으로 ON, OFF되는 센서가 부착된 형광등기구를 사용하여 에너지가 절감될 수 있는 방안을 연구하고 자한다.

  • PDF

교류 고속철도계통에서 BESS의 도입을 위한 전력소비 및 충·방전효과 분석에 관한 연구 (Study on Analysis for Power Consumption and Charge/Discharge Effect with BESS in AC High-Speed Electric Railway System)

  • 전용주;강병욱;채희석;김재철
    • 조명전기설비학회논문지
    • /
    • 제28권9호
    • /
    • pp.20-27
    • /
    • 2014
  • The power consumption pattern of high-speed railway has rarely during night time. But, during service time, the power is consumed irregularly related to train operation. Especially certain unusual about 1-2 days of service time interval to indicate the power consumption is rapidly growing phenomenon, which causes the capacity of the power contract is the annual electricity bill to rise rapidly as the cause. Normally, amount of peak power consumption bill rate at railway substation is over 20% of total electrical bill. Therefore, high-speed railway substation is expected to be considerably larger savings by reducing the peak power of the default charge(demand power).

자동전원 계폐장치에 관한 연구 (Study on Divice for the Automatic Shut Off of Equipment Stand-by Power)

  • 김형광;현기웅;배종일;양순용;박성태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2626-2627
    • /
    • 1999
  • The device we have developed is the automatic shut off equipment which will reduce energy consumption when an equipment is in stand by power state. The principle for this system is when a man is moving, electricity will flow by setting a on-off light system. At night, in the stand-by power state the electric supply will be shut off immediately which will reduce energy consumption. Energy consumed by 24hour operating machines and stand-by electronic devices will be reduced by pulse signals which will give power supply when needed.

  • PDF

연료전지 차량용 공기 블로워의 공력 설계 (Aerodynamic Design of Cathode Air Blower for Fuel Cell Electric Vehicle)

  • 김우준;박창호;지용준;조경석;김영대;박세영;오창훈
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.197-200
    • /
    • 2007
  • FCEV uses electric energy generated from fuel cell stack, thus all consisting parts must be re-designed to be suitable for electricity based system. Cathode air blower which supplies compressed air into fuel cell stack has similar shape of turbocharger, but a radial turbine of traditional turbocharger is removed and high speed BLDC motor is installed . Generally, maximum 10% of electric power of fuel cell stack is consumed in air blower, therefore an effective design of air blower can improve the performance of FCEV directly. This study will present an aerodynamic design process of an air blower and compare computational results with experimental data.

  • PDF

사무용 빌딩의 조명전력 허용기준 연구 (Decision of Lighting Power Density for Office Building Lighting)

  • 이상진;이민욱;김훈
    • 조명전기설비학회논문지
    • /
    • 제26권1호
    • /
    • pp.22-28
    • /
    • 2012
  • To identify energy savings when comparing lighting designs or evaluating installed lighting, it is necessary to analyze the consumption of lighting power with respect to the electricity consumed and the lighting area. In Korea, however, these factors have not been considered in lighting design. In this paper, the lighting power-related standards on indoor lighting in foreign countries have been analyzed. It is determine appropriate lighting power consumption for indoor by calculating the energy consumption has been estimated in a lighting design adopted domestic luminaire used.