• 제목/요약/키워드: construction waterproofing

검색결과 337건 처리시간 0.024초

복합계 멤브레인 방수층의 수밀성 시험 평가방법 개선방안 연구 (Improvement of Watertightness Evaluation Method in Waterproof Membrane)

  • 김명지;선윤숙;김수연;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.50-51
    • /
    • 2018
  • Although the introduction of new materials and new construction methods and overseas materials has become more active due to the diversification of the construction market, the quality standards of waterproofing methods in Korea are insufficient. In particular, the quality control standard is applied to the KS F 2622:08 (Membrane Waterproofing layer performance test method), which is the existing standard, to prepare standards for quality control of waterproof materials, which is increased in Korea.

  • PDF

Estimating the Physical Demand of Waterproofing Worker

  • Lim, Tae-Kyung;Lee, Dong-Eun
    • 국제학술발표논문집
    • /
    • The 6th International Conference on Construction Engineering and Project Management
    • /
    • pp.101-103
    • /
    • 2015
  • Scientific methods that measure the physical demand requirements of a construction operation have not been arrived at maturity in construction community. It is attributed to the difficulty involved in performing controlled experiments on the operation and its' volatile jobsite environment. This paper presents a method that measures the physical demand requirement of the waterproofing activity and verifies the differences between various operations (e.g., a primer painting and a polyurethane coating) consisting of the activity. Two hypotheses, which are involved in the operations, are summarized as follows: [Hypothesis 1] when one performs the same amount of work; the one's average heart rate required for the polyurethane coating operation is higher than that required for the primer painting operation. [Hypothesis 2] when one performs the same amount of work, the one's break time required for the polyurethane coating operation is longer than that required for the primer painting operation.

  • PDF

폴리우레아 도막방수재의 이음부 적정 시공안 제안을 위한 성능 분석 (Performance Analysis for Proposing Proper Construction Method for Joints of Polyurea Waterproofing Membrane Coating)

  • 이정훈;김병일
    • 한국건축시공학회지
    • /
    • 제24권1호
    • /
    • pp.77-86
    • /
    • 2024
  • 본 연구에서는 폴리우레아 도막방수재의 시공 시차별 분석과 열화면에 대한 유지관리 시공 타입별 분석을 통해 시공 이음부위의 적정 시공 방안을 제시하고자 전체 16가지 조건을 대상으로 시공 이음부위에 대한 평가를 진행하였다. 결과 분석을 통해 시공시차가 길어지면 길어질수록 이음부를 통한 누수발생률은 증가하는 것으로 분석되었고, 프라이머 시공을 통해 누수 예방이 가능한 것으로 확인되었다. 또한 장시간 옥외 노출된 폴리우레아는 표면이 열화되어 약해진 상태이기 때문에 해당 부위를 연마할 경우 표면손상이 확대되어 계면 형성에 영향을 미치는 것으로 분석되어, 유지관리 시공 시에는 프라이머를 도포하고 시공하는 것이 바람직하겠으며, 동일한 우레아 계열의 재료를 시공하는 것이 방수 안정성을 확보할 수 있을 것으로 판단된다.

생태교량 적용을 위한 방수·방근공법의 Mock-up 시험 연구 (A Study on the Mock-up Test of Waterproofing/Root Penetration Resistance Technology for the Application to an Eco-bridge)

  • 선윤숙;최수영;김명지;최성민;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.230-231
    • /
    • 2014
  • This study is concerned with the root penetration resistance competence and constructability of a waterproofing and root penetration resistance layer of an eco-bridge which is applied with various types of seeding. For the review of root penetration resistance competence, the competence was tested using herbs, woody plants, and tall trees. As a result, there was no tear of or damage to the waterproofing and root penetration resistance layer as well as the sweeping-down phenomenon of a waterproofing and root penetration resistance layer by soil. Also, the effect of the root growth of herbs, woody plants, and tall trees on the root penetration resistance system was confirmed.

  • PDF

역수압 작용을 고려한 방수·방식재의 부착강도 시험방법에 관한 연구 (A Study on the Test Methods of Bond Strength in Waterproofing and Anti-corrosion Materials by Reversed Pressure)

  • 김명지;최수영;최성민;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.232-233
    • /
    • 2014
  • Recently, water treatment facility is usually eastablished in underground, and waterproofing and anti-corrosion materials for concrete structures applied water treatment tank is developing in various ways. However, as the limit of research focused on durability improvement of top coating material, it is insufficient to study on the adhesion strength between the concrete surface and primer. Therefore, there is to confirm the adhesion of between concrete surface and the three primers used as anti-corrosion waterproofing materials, and to investigate the properties of adhesion strength according to the condition such as wet codition and water pressure condition of the concrete surface in this study.

  • PDF

반턱 고무 아스팔트 칼라 시트를 이용한 접합부 맞춤식 옥상 노출 방수공법에 관한 실험적 연구 (An Experimental Study on the Roof Exposure Waterproofing Method of Tenon Jointing Type used Shiplap Rubberized Asphalt Color Sheet)

  • 이정훈;이선규;곽효야;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 춘계 학술논문 발표대회
    • /
    • pp.73-77
    • /
    • 2008
  • In this study, we would like to study on the application of roof exposure waterproofing method of joint stability through shiplap rubberized asphalt color sheet to complement problem of fracture, exfoliation and water leakage by existing roof exposure sheet waterproofing material joint weakness. Accordingly, examined basis performance and stability for joint that shiplap rubberized asphalt color sheet through test of that tensile strength, bonding strength, water permeability after bonding, peel resistance after bonding, lengthen resistance after bonding and hang resistance after bonding. The results of this study, waterproofing method to using shiplap rubberized asphalt color sheet is judged to solved fracture, exfoliation and water leakage problems happened in joint by problem was joint of exposure sheet by minimizing gap of joint being integration by shiplap.

  • PDF

유류성분이 지하구조물의 방수층 손상에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Damage of Waterproofing Membrane due to Oil ingredient of Underground Structures)

  • 송제영;강효진;곽규성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 춘계학술논문 발표대회 제6권1호
    • /
    • pp.177-180
    • /
    • 2006
  • The accidents of oil leakage is increasing in the Underground Concrete structures for Oil Storege. In the result, the waterproofing in the underground structures is melt down and cannot fulfil its Performance. This study shows an experimental study in the effects of the oil leakage to on the performance of Waterproofing Materials. In order to investigate the actual condition and the problems, a comparative analyses were conducted considering the various types of leakage. Utilizing the obtained results at the basic data for test methods and the standard of quality, we intended to propose a strategy to develop an innovated waterproofing Materials and improve the clean environment of underground structures.

  • PDF

돌기형 접합 보강재를 이용한 옥상 노출 복합방수의 조인트 시공방법에 관한 연구 (Sheet Jointing Method of the Roof Exposed Hybrid Waterproofing Using the Bump-type Joint Reinforcement)

  • 김명지;안기원;김동춘;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.147-148
    • /
    • 2018
  • Seat waterproofing materials applied to the roof of a building concrete structure inevitably produce joints and are applied with opposite dam joints or overlapping joints depending on the waterproof material applied to the top of the sheet. In this case, the joint performance is determined by the material at the top, rather than by the superimposed joint. In order to solve this problem, various reinforcements have been used to apply to the connecting parts of the opposite dam, but the problem of attachment between different materials or the lack of reinforcement of the joint tape has not been solved. Therefore, for the purpose of securing tensile performance to the joints, this study is used as a reinforcement for the joints of PP materials with high tensile performance and as a reinforcement for nylon materials.

  • PDF

Non-destructive Leakage Location Analysis Method in Substrate Behavior Response Testing of Waterproofing Membrane Systems using Thermal Emission Camera

  • 오규환;강파;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.47-48
    • /
    • 2017
  • The substrate behavior response testing outlined in KS F 2622 evaluates the leakage cause of waterproofing membrane systems when subjected to the concrete joint load behaviors by removing the waterproofing layer after testing, relying mostly on visual observation and subjective analysis. A non-destructive leakage cause and failure type analysis method is proposed currently in this study by the means of detecting leakage paths using thermal emission imaging systems. Test specimens are placed in varying temperature conditions after the concrete joint movement testing and are scanned using the thermal emission camera to determine the location and dimension of the adhesion failure/leakage path beneath the waterproofing membranes.

  • PDF

철도교량에 거동발생 시 응력분포 분석에 따른 적정 방수재료 선정을 위한 평가 방법 (Waterproofing Material Evaluation Method based on Stress Dispersion Analysis due to Displacement in Railway Bridges)

  • 오규환;안기원;김수연;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.59-60
    • /
    • 2021
  • To measure the effect of the stress-strain dispersion across the installed waterproofing layer on the concrete surface, a strain gauge was attached to the gap between the waterproofing layer and the concrete structure at specified points of upper, center and bottom of the load-displacement simulation specimen, and the peak stress-strain at the displacement interface were measured and compared with stress-strain at other areas to analyze each material types' stress-strain dispersion ratio properties. Based on the results of the testing, it was shown that materials with high load-displacement resistance performance accordingly had high stress-strain dispersion ratio results, and the materials from highest performance to lowest performance were; CAS, SAS, PUC and CSC.

  • PDF