• Title/Summary/Keyword: construction costs

Search Result 1,556, Processing Time 0.023 seconds

Analysis on Emergency Power Supplies in Buildings and a Model for Safe Operation of the Emergency Power System (건축물의 비상전원 적용실태 및 자가발전설비의 안전 운전 모델에 관한 연구)

  • Lee, Won-Kang;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.49-56
    • /
    • 2012
  • The purpose of this paper is to present a model for operating an emergency power system(EPS) that can secure a sufficient power supply used in case of a fire by analyzing the status of power supplies for emergency and firefighting operations. Investigations on the one of the causes of the operational failure of firefighting systems show evidence of EPS. Generally, when power to a building is interrupted, EPS supplies the emergency load(excepted firefighting load) first. When a power outage and a fire occur simultaneously, the EPS must be able to supply both the emergency load and the firefighting load, especially the firefighting load to the end. However, in order to save construction costs, emergency power generators in apartment, commercial, and business buildings can satisfy only one of the required loads. In cases like this, when a power outage and a fire occur simultaneously, there is a danger of firefighting equipment not operating due to insufficient power supply from the emergency generator. Therefore, an EPS must have a reserved firefighting power that can supply both the firefighting and the emergency load. Such EPS, when faced with a danger of an overload, will shut down the supply to all or part of the emergency load, thus securing a continuous power supply to the firefighting equipment. The generator power system with reserved firefighting power (RFP) will also have an indicator to show that the selective control is being used. General power generation systems for emergency load and firefighting load were found to have a demand factor of 50-60% with a lump. However, when installing an EPS, the builders must choose the higher demand factor suggested according to the official approval demand factor of the building.

A Study of the Rationalization of Handling Facility Safety Management Standard for Hazardous Chemicals : Focusing on Dike (화학물질 안전관리 시설기준 합리화 연구 : 방류벽 중심)

  • Kim, Nam-Suk;Yoo, Byung-Tae
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.2
    • /
    • pp.29-35
    • /
    • 2020
  • The Chemical Control Act has revised in 2015 to promote chemical safety, particularly enhancing the standards for the installation and management of hazardous chemical handling facilities. However, in some existing facilities, it was difficult to comply with some facility standards because of lack of land, safety accident possibility during rebuilding. In this study, we attempted to provide a more rational approach of dike standard which was the highest(2017: 117, 2018: 83) complaint for two years(2017~2018, 1,087) by prior study, FLACS simulation, analyze safety management standard and conduct a survey. Therefore, considering the purpose of installing the discharge wall only at existing facilities in operation, additional sensors that can detect chemical leakage and leakage were recognized as an additional alternative to installing and operating closed circuit television (CCTV). This will help the safety and cost aspects of small or medium-sized businesses or small and medium-sized enterprises that cannot secure legal grounds or fail to enforce legal regulations due to economic problems such as construction costs.

Performance Modeling of an EPC Information Service System

  • Kim, So-Jung;Kang, Yong-Shin;Son, Kyung-Won;Lee, Yong-Han;Rhee, Jong-Tae;Hong, Sung-Jo
    • Industrial Engineering and Management Systems
    • /
    • v.9 no.3
    • /
    • pp.285-293
    • /
    • 2010
  • To obtain visible and traceable information from the supply chain, HW/SW standards for the EPC global network, which process electronic product code (EPC) data read from Radio frequency identification (RFID) tags, are regarded as the de facto industry standard. Supply chain participants install information service systems and provide logistics information to partners by following the EPCglobal architecture framework. Although quality of service (QoS) is essential for providing dependable and scalable services as pointed out by Auto-ID Lab, only a few models for the performance analysis of QoS-related work have been developed in the context of EPC information service systems. Specifically, doing so allows alternative design choices to be tested in an easy and cost-effective manner and can highlight potential performance problems in designs long before any construction costs are incurred. Thus, in this study we construct a model of an EPC information service system for the purposes of performance analysis and designing a dependable system. We also develop a set of building blocks for analytical performance models. To illustrate how the model works, we determine the characteristics of an EPC information service system and then select a combination of these proven modeling concepts. We construct a performance model that considers the response time and shows how to derive meaningful performance values. Finally, we compare the analytical results to measurements of the EPC information service system.

Development of Optimum Design Program for PPC Structures using DCOC (이산성 연속형 최적성 규준을 이용한 PPC 구조의 최적설계프로그램 개발)

  • 한상훈;조홍동;이상근
    • Computational Structural Engineering
    • /
    • v.10 no.4
    • /
    • pp.315-325
    • /
    • 1997
  • This paper describes the application of discretized continuum-type optimality criteria (DCOC) and the development of optimum design program for the multispan partially prestressed concrete beams. The cost of construction as objective function which includes the costs of concrete, prestressing steel, non-prestressing steel and formwork is minimized. The design constraints include limits on the maximum deflection, flexural and shear strengths, in addition to ductility requirements, and upper and lower bounds on design variables as stipulated by the design Code. Based on Kuhn-Tucker necessary conditions, the optimality criteria are explicitly derived in terms of the design variables-effective depth, eccentricity of prestressing steel and non-prestressing steel ratio. The prestressing profile is prescribed by parabolic functions. The self-weight of the structure is included in the equilibrium equation of the real system, as is the secondary effect resulting from the prestressing force. An iterative procedure and computer program for updating the design variables are developed. Two numerical examples of multispan PPC beams with rectangular cross-section are solved to show the applicability and efficiency of the DCOC-based technique.

  • PDF

Improvement for Asset Management of Sewage Treatment Facilities (하수처리시설 대수선비 자산화 영향분석 및 제도개선 방안)

  • Park, Ha Jin;An, Man Sun;Cho, Nam Ho;Kim, Kyong Ju
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.2D
    • /
    • pp.285-293
    • /
    • 2011
  • Sewage treatment facilities are growing rapidly in quantitatively and qualitatively. However, privatization such as up-size and professionalism, etc. are insufficient, compared to global companies' cases. Infrastructure Asset management has not been applied widely despite of sewage treatment facilities are one of the most critical social infrastructure. Maintenance, repair, and rehabilitation (R&R) practices of sewage treatment facilities have been studied and infrastructures asset management techniques have been applied. Cost model which makes it possible to calculate managerial costs such as major cost, etc. needs to be developed only with project basic information when proceeding new sewage treatment facility construction and management and overseas sewage project. Effects to converse major repair cost into capital, application of sewage treatment facility's asset management, expected effects, etc. were analyzed and suggested an alternative on the improvements of legal system.

Assessment and quantification of hurricane induced damage to houses

  • Chiu, Gregory L.F.;Wadia-Fascetti, Sara Jean
    • Wind and Structures
    • /
    • v.2 no.3
    • /
    • pp.133-150
    • /
    • 1999
  • Significant costs to the public and private sectors due to recent extreme wind events have motivated the need for systematic post-hurricane damage data collection and analysis. Current post disaster data are collected by many different interested groups such as government agencies, voluntary disaster relief agencies, representatives of media companies, academicians and companies in the private sector. Each group has an interest in a particular type of data. However, members of each group collect data using different techniques. This disparity in data is not conducive to quantifying damage data and, therefore, inhibits the statistical and spatial description of damage and comparisons of damage among different extreme wind events. The data collection does not allow comparisons of data or results of analyses within a group and also prohibits comparison of damage data and information among different groups. Typically, analyses of data from a given event lead to different conclusion depending upon the definition of damage used by individual investigators and the type of data collected making it difficult for members of groups to compare the results of their analyses with a common language and basis. A formal method of data collection and analysis-within any single group-would allow comparisons to be made among different individuals, hazardous events and eventually among different groups, thus facilitating the management and reduction of damage due to future disaster. This research introduces a definition of damage to single family dwellings, and a common method of data collection and analysis suited for groups interested in regional characterization of damage. The current state-of-data is presented and a method for data collection is recommended based on these existing data collection methods. A fixed-scale damage index is proposed to consider the damage to a dwelling's feature. Finally, the damage index is applied to three dwellings damaged by Hurricane Iniki (1992). The damage index reflects the reduced functionality of a structure as a single family detached dwelling and provides a means to evaluate regional damage due to a single event or to compare damage due to events of different severity. Evaluation of the damage index and the data available support recommendation for future data collection efforts.

Reduction of perchlorate using zero-valent titanium (ZVT) anode: reaction mechanism

  • Lee, Chunwoo;Batchelor, Bill;Park, Sung Hyuk;Han, Dong Suk;Abdel-Wahab, Ahmed;Kramer, Timothy A.
    • Advances in environmental research
    • /
    • v.1 no.1
    • /
    • pp.37-55
    • /
    • 2012
  • Here we show that perchlorate reduction during pitting corrosion of zero-valent titanium (ZVT) is likely caused by dissolved titanium species, especially Ti(II). Several possible mechanisms were suggested based on the literature and were evaluated based on experimental observations. Direct reduction of perchlorate on the bare metal of the ZVT electrode was thermodynamically infeasible due to the high anodic potential that was applied. Other potential mechanisms were considered such as reduction by small ZVT metal particles released from the electrode and direct reduction on the oxide layer of the electrode where potential was sufficiently reduced by a high ohmic potential drop. However, these mechanisms were not supported by experimental results. The most likely mechanism for perchlorate reduction was that during pitting corrosion, in which ZVT is partially oxidized to form dissolved ions such as Ti(II), which diffuse from the electrode surface and react with perchlorate in solution. This mechanism is supported by measurements of the dissolution valence and the molar ratio of ZVT consumed to perchlorate reduced (${\Delta}Ti(0)/{\Delta}ClO_4{^-}$). The results shown in this study demonstrate that ZVT undergoing pitting corrosion has the capability to chemically reduce perchlorate by producing dissolved Ti(II) and therefore, it has the potential to be applied in treatment systems. On the other hand, the results of this research imply that the application of ZVT undergoing pitting corrosion in treatment systems may not be feasible now due to several factors, including material and electricity costs and possible chloride oxidation.

Investigation of the refined safety factor for berthing energy calculation

  • Kim, Sang Woo;Lee, Seung Jae;Kim, Young Tae;Kim, Do Kyun
    • Structural Engineering and Mechanics
    • /
    • v.75 no.6
    • /
    • pp.785-797
    • /
    • 2020
  • As the growth of world trade has surged rapidly over the past years, the number is expected to continue growing over the coming years. Although the transportation costs can be reduced by using larger vessels, however, new berthing structures have to be constructed in order to cater for the larger vessels. This leads to a need for researching on designing a better berthing structure. For optimization of berthing structure design, we need to provide a better estimation of berthing energy than the previous methods in the existing guidelines. In this study, several berthing parameters were collected from previous works and researches. Moreover, the scenarios were selected efficiently by using a sampling technique. First, the berthing energy was calculated by executing 150 numerical simulations. Then, the numerical simulation results were compared with the results calculated by existing methods quantitatively to investigate the sensitivity of the berthing parameters and the accuracy of existing methods. The numerical method results have shown some deviation with respect to the existing method results in which the degree of deviation varies with the methods and the tendency of differences is dependent on certain berthing parameters. Then, one of the existing methods which has shown a small deviation was selected as a representative method and applied with several safety factors to obtain a suitable safety factor for the design.

An Efficient 3D Inversion of MT Data Using Approximate Sensitivities (효율적인 3차원 MT 역산을 위한 다양한 감도의 이용)

  • Han, Nu-Ree;Nam, Myung-Jin;Kim, Hee-Joon;Lee, Tae-Jong;Song, Yoon-Ho;Suh, Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.4
    • /
    • pp.259-267
    • /
    • 2007
  • An efficient algorithm for inverting static-shifted magnetotelluric (MT) data has been proposed to produce a three-dimensional (3D) resistivity model. In the Gauss-Newton approach, computational costs associated with construction of a full sensitivity matrix usually make 3D MT inversion impractical. This computational difficulty may be overcome by using approximate sensitivities. We use four kinds of sensitivities in particular orders in the inversion process. These sensitivities are computed 1) analytically for an initial, homogeneous earth, 2) exactly for a current model, 3) approximately by the Broyden method, and 4) approximately using the previous adjoint fields. Inversion experiments with static-shifted synthetic and field MT data indicate that inversion results are highly dependent on characteristics of data and thus applying various combinations of sensitivities is helpful in obtaining a good image of the subsurface structure with reasonable computation time.

The Hydrodynamical Study on the Selection of Planing Hull Forms. (Planing Hull의 선형선택(船型選擇)에 따르는 유체역학적(流體力學的) 고찰(考察))

  • Sun-Young,Pak;Sang-Hyouk,Choi
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.2 no.1
    • /
    • pp.9-14
    • /
    • 1965
  • Ship designers make every efforts to get faster ships in accordance with the development of the Naval Architecture. But for the speed lying over factor length ratio 2.5-3.0, we could put a powerful engine into the conventional round bottom displacement type vessels, but it is very difficult in view point of economy, weight and volume. The principal cause of these speed obstacles is the wave making resistance and researchers are trying to decrease this resistance. One of the resolving ways, planing hulls were applied to small high boats. Planing hull's advantage is not restricted to speed, but the workmanship of the planing hull is easier than those of displacement type vessels of round bottom. Planing hull, therefore, are widely applicable to the intermediate speed boats, which don't have enough high speed to take planing advantage, as well as high speed boats. We will discuss related phenomena of the planing hull in details and this paper we particularly interested in the interjection point(speed length ratio 3.0-3.5 by Mr. D. De Groots) between semi-planing and full planing hulls on the resistance characteristic curve. The paper by Prof. Keuck Chun Kim, "Some Characteristics of Straight Framed V-bottom Hull Forms", Journal of the society of Naval Architects of Korea, Vol.1, No.1, Dec.5, 1964, is referred to the V-bottom hull forms belonging to low speed region and determines practical applicable limit of the speed length ratio combined with construction costs, under which are still used by large commercial vessels. This is the interesting contrast between his and authors. We will further discuss the speed length ratio which is considered as a beginning point to planing effect. For this analysis, we choose 3 model ships: Model (1) and (2) have the same principal dimensions, model 3 varied dimension. Model (1) is full-planing hull, (2) is semi-planing hull and (3) is complete planing hull. They are aimed to collect proper design data for purposed ships.

  • PDF