내압방폭구조에서 수소-공기와 아세틸렌-공기 혼합가스의 폭발압력과 상대습도의 상관관계 분석 (Relationship Analysis between Relative Humidity and Explosion Pressure of Hydrogen-Air and Acetylene-Air Mixtures in Flameproof Enclosure )

  • 김용태;정기효
    • 대한안전경영과학회지
    • /
    • 제24권4호
    • /
    • pp.101-107
    • /
    • 2022
  • To test a flameproof enclosure for the safety certificate, a reference pressure of explosion needs to be determined. However, the explosion pressure may be changed according to relative humidity of explosive gases. Therefore, the guideline on relative humidity should be recommended for measuring the explosion pressure for accurate and reproducible testings. This study examined the relationship of explosion pressure with relative humidity of hydrogen (31 vol %)-air and acetylene (14 vol %)-air mixture gases. The explosion pressures were measured by increasing the relative humidity of the gases by 10 % from dry state to 80 % in a cylindrical explosion enclosure of 2.3 L. on ambient temperature and atmospheric pressure (1 atm). The maximum explosive pressures were remained almost constant until the relative humidity reached 10 % for the hydrogen-air mixture and 20 % for the acetylene-air mixture. However, the maximum explosive pressures linearly decreased as the relative humidity increased. Based on the results of the study, it would be recommended to use 10 % relative humidity for the hydrogen-air mixture and 20 % for the acetylene-air mixture as the critical value in testing a flameproof enclosure.

온·습도센서(BME 280 센서)를 이용한 PET/CT 장비의 항온 항습기 온·습도 평가 (Evaluation of Temperature and Humidity of a Thermo-Hygrostat of PET/CT Equipment using a Temperature and Humidity Sensor(BME 280))

  • 류찬주;김정아;김준수;윤근영;허승희;홍성종
    • 한국방사선학회논문지
    • /
    • 제14권1호
    • /
    • pp.15-22
    • /
    • 2020
  • PET(Positron Emission Tomography)장치는 해부학적 정보를 얻기 위한 CT와 MRI의 장치를 PET 장치와 융합시킨 PET/CT나 PET/MRI 장치로 사용된다. 그렇기 때문에 일반 의료장비들과 비교하여 Gantry(촬영부 본체)의 길이가 늘어나고 내부의 공간이 넓어지는 원형(ring)타입의 구조로 제작된다. PET 장치의 구성요소 중 하나인 신틸레이터는 Gantry 안쪽에 위치하는데 온·습도 변화에 민감한 크리스탈 성분으로 되어있기 때문에 커다란 온도 변화로 인해 신틸레이터의 손상을 가져올 수 있다. 신틸레이터는 항온항습기로 PET장치가 설치되어 있는 공간에 온·습도를 유지하지만 이러한 PET 장치의 구조적 원인과 CT 장비에서 발생하는 열로 인한 Gantry 내부의 온·습도의 변화가 예상된다. 항온항습기를 가동하여 온·습도를 유지중인 PET/CT 장치의 Gantry 내부를 6개의 구역으로 나눈 후 각 구역에 Arduino 온·습도 센서인 Adafruit BME 280을 부착하여 출력 값을 분석했다. 각 6개 구역에서 센서를 이용해 측정한 평균 온·습도 값과 항온항습기의 평균 측정값을 비교하면 평균적으로 온도는 2.71℃ 상승, 습도는 21.5% 감소의 차이가 발생하였고, PET Gantry의 온·습도 측정값은 국내에서 지정한 정도 관리 범위에서 벗어나는 결과 값이 나왔다. 연구 결과를 통해 앞으로 지속적인 온·습도의 변화를 가진다면 PET Gantry 안에 장착된 신틸레이터의 노후화가 예상되므로 Gantry구조 내부의 온·습도를 적절히 유지하는 방안을 모색해야 한다.

완충공간의 설치가 이유자돈사 온·습도변화 및 자돈 폐사율에 미치는 영향 (Effects of Buffering Zone Installation on the Temperature and Humidity of Pig House and Mortality of Weaned Pig)

  • 이준엽;이동현;우샘이;최희철
    • 한국축산시설환경학회지
    • /
    • 제21권3호
    • /
    • pp.77-82
    • /
    • 2015
  • This survey was conducted to collect basic data about the effect of buffering zone installation in weaned pig house. Buffering zone was installed either inside or outside of pig house to compare changes of temperature, humidity and air velocity of pig room. The body weight and mortality of weaned pigs in house with buffering zone was also measured. There was no difference in temperature, humidity and air velocity between inside and outside buffering zone. Mortality of weaned pig in house with buffering zone was drastically decreased compare to pigs in house without buffering zone that could be useful to maintain constant temperature and decrease mortality.

에어로졸 증착한 세라믹/금속 복합막의 금속 함량에 따른 습도 감지 특성 연구 (Study of Humidity Sensing Properties Related to Metal Content of Aerosol Deposited Ceramic/Metal Composite Films)

  • 김익수;구상모;박철환;신원호;이동원;오종민
    • 한국전기전자재료학회논문지
    • /
    • 제34권5호
    • /
    • pp.314-320
    • /
    • 2021
  • Controlling ambient humid condition through high performance humidity sensors has become important for various fields, including industrial process, food storage, and the preservation of historic remains. Although aerosol deposited humidity sensors using ceramic BaTiO3 (BT) material have been widely studied because of their longtime stability, there remain critical disadvantages, such as low sensitivity, low linearity, and slow response/recovery time in case of the sensors fabricated at room temperature. To achieve superior humidity sensing properties even at room temperature condition, BT-Cu composite films utilizing aerosol deposition (AD) process have been proposed based on the percolation theory. The BT-Cu composite films showed gradually improved sensing properties until the Cu concentration reached 15 wt% in the composite film. However, the excessive Cu (above 30 wt%) containing BT-Cu composite films showed a rapid decrease of the sensing properties. The results of observed surface morphology of the AD fabricated composite films, to figure out the metal filler effect, showed correlation between surface topography as well as size and the amount of open pores according to the metal filler content. Overall, it is very important not only dielectric constant of the humidity sensing films but also microstructures, because they affect either the variation range of capacitance by ambient humidity or adsorption/desorption of ambient humidity onto/from the humidity sensing films.

혼합 유기용제 포집시 습도가 활성탄관의 파과에 미치는 영향 (Effect of Relative Humidity on the Breakthrough of Charcoal Tubes during Mixed Organic Vapor Sampling)

  • 양혁승;김현욱
    • 한국산업보건학회지
    • /
    • 제6권1호
    • /
    • pp.125-137
    • /
    • 1996
  • This study was designed to investigate effects of relative humidity on the breakthrough of charcoal tubes at a fixed vapor concentration and sampling time during mixed organic vapor sampling. A vapor generator was used to generate three different concentrations of mixed organic vapor and a stainless steel chamber was fabricated and utilized to maintain three different percentages of relative humidity while maintaining a constant temperature. The results were as follows; 1. At high relative humidity, breakthrough of mixed organic vapor occurred quickly at low vapor concentration than at high vapor concentration because of the reduced adsorption volume of charcoal tube due to humidity. 2. Breakthrough by competitive adsorption of vapors onto charcoal tube was observed at first from n-hexane having the lowest boiling point and highest vapor pressure among the three organic vapors investigated, followed by TCE. No breakthrough was observed from toluene under all experimental conditions. 3. For n-hexane, breakthrough was observed after 2 hours of sampling and breakthrough rates were increased as relative humidity increased. For TCE, breakthrough was found after 3 hours of sampling and breakthrough rates by sampling time were increased as vapor concentration increased. 4. The adsorbed amount of mixed organic vapor at breakthrough was shown to have statistically significant correlations with sampling time, relative humidity, and vapor concentration in descending order of correlation. Relative humidity and sampling time for n-hexane and sampling time and concentration for TCE were both statistically significantly correlated. 5. Relative humidity was found to affect the amount of breakthrough of mixed organic vapor and n-hexane. Among three percentages of relative humidity investigated, the amount of breakthrough at 85 % relative humidity was significantly larger than those of at lower percentages of relative humidity. No statistically significant difference was found between 25 % and 55 % relative humidity. 6. The results of multiple regression analysis between breakthrough and relative humidity, vapor concentrations showed that the coefficient of determination of mixed organic vapor was 0.263 and those of n-hexane and TCE were 0.275 and 0.189, respectively. 7. Flow rates of sampling pumps used were found to be affected by relative humidity present. At 25 %, 55 %, and 85 % relative humidity, the relative errors of sampling pump were 1.4 %, 13.4 %, and 18.6 %, respectively. In conclusion, the results of this study showed that high relative humidity could reduce the adsorption volume of charcoal tubes and subsequently increase breakthrough rates. Therefore, to prevent breakthrough when sampling mixed organic vapors, it is suggested that either sampling volume be reduced on the flow rate be lowered so as to minimize breakthrough of the most volatile organic vapor in the mixture. In addition, since the flow rates of a sampling pump can be adversely affected by high relative humidity, it is recommended to use a constant flow mode pump when sampling in the highly humid environment.

  • PDF

전기영동법에 의해 제작된 폴리이미드 박막의 습도 특성 (Characteristics of Polyimides Humility Sensor Fabricated by using Electrophoretic Deposition)

  • 조동헌;정병기;한상옥;김종석;박강식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1994년도 춘계학술대회 논문집
    • /
    • pp.67-70
    • /
    • 1994
  • On this study, we fabricated humudity sensor with polyimide thin film from the nonaqueous emulsion by the electrophoretic deposition as a function of film thickness. then evaluated performance of the sensor with increasing relative humidity if constant temperature constant humidity chamber, which is electronically controlled. we designed upper electrode of the sensor to brush type to make moisture particles permeate into the polymer bulk. sensing properties of the sensor on % RH shows proportion on the low %RH. Fer the 30V-30S- 200$^{\circ}C$ sample, percentage changing of capacitance on from 30 %RH to 90 %RH is 45.8 %, and increasing rate per 1 % RH of capacitance is 11.25 pF

  • PDF

아파트 실내정원의 겨울철 실내온열환경 조절효과 (Indoor Environmental Efficiency Indoor Garden in Apartment House during Winter)

  • 김정민;최윤정
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.212-216
    • /
    • 2005
  • The purpose of this study is to make clear the indoor thermal environmental efficiency of indoor garden in apartment during winter. The questionnaire survey was carried out during the l0th${\sim}$20th of February 2004, respondents consisted of 215 residents living in a subject apartment estate. The field measurements of indoor thermal elements were carried out at A house with indoor garden and at B house without indoor garden. The measurements in two-subject houses were taken on simultaneously the 11th of February. As Results, the residents living in apartments with indoor garden show positive response on air moisture and satisfaction. The daily ranges of indoor temperature and globe temperature in the A house were narrower than the B house. The average relative humidity in the A house was higher and constant than the B house. Therefore, it was seemed that indoor environment during winter in the house with indoor garden maintained more constant or comfortable than the house without indoor garden by earning effect and humidity control effect of plants.

  • PDF

EFFECT OF CONTINUOUS AND STEPWISE CHANGE IN DRYING TEMPERATURE ON DRYING CHARACTERISTICS AND PRODUCT QUALITY

  • Chua, K.J.;Mujumdar, A.S.;A Hawlader, M.N.;Chou, S.K.;Ho, J.C.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.II
    • /
    • pp.413-422
    • /
    • 2000
  • Samples of banana were dried in a two-stage heat pump dryer capable of producing stepwise control of the inlet drying air temperature while keeping absolute humidity constant. Two stepwise air temperature profiles were tested. The incremental temperature step change in temperature of the drying air about the mean air temperature of 30 $^{\circ}C$ was 5 $^{\circ}C$. The total drying time for each temperature-time profile was about 300 minutes. The drying kinetics and color change of the products dried under these stepwise variation of the inlet air temperature were measured and compared with constant air temperature drying. The stepwise air temperature variation was found to yield better quality product in terms of color of the dried product. Further, it was found that by employing a step-down temperature profile, it was possible to reduce the drying time to reach the desired moisture content.

  • PDF

恒溫條件下에서의 우리벼메뚜기 ( Oxya sinuosa ) 의 發育 (Development of the Short-Horned Grasshoppers, Oxya sinuosa, at the Constant Temperature)

  • Joo, Eun-Young
    • The Korean Journal of Ecology
    • /
    • 제14권1호
    • /
    • pp.9-13
    • /
    • 1991
  • The short-horned grasshoppers, Oxya sinuosa Mistshenko, were reared in the growth cabinet exposed alternately to 16 hours of artificial light (510${\pm}$240 lux) and 8 hours of darkness under the condition of constant temperature of 30${\circ}C$ and 65${\pm}$3% in relative humidity. The results obtained in this study are summarized as follows. Both female and male grasshoppers had seven instars. In the larval developmental stages of female and male, the third stage was shorter than the other stages, and the longest stage was the seventh. The total developmental period of females and males were approximately 80.17 and 63.5 days, respectively. The survivorship curve at the temperature of 30${\circ}C$ shows straight line.

  • PDF

실외조명 LED용 SMPS의 가속수명시험법 제안 (Suggested Accelerated Life Test Method of SMPS for Outdoor Lighting LED)

  • 임성용;형재필;임홍우;오근태
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제18권1호
    • /
    • pp.8-19
    • /
    • 2018
  • Purpose: This study has developed the accelerated lifetime test method for smps for outdoor lighting LED through two factors of temperature and humidity. Methods: Acceleration condition was confirmed for each stress and model, and acceleration life test model was estimated according to acceleration condition. Results: As a result of confirming the accelerated life test model, in the case of humidity, acceleration was established only in the foreign products. Therefore, it is confirmed that the acceleration condition is insufficient. However, the estimated parameters for temperature are relatively constant. It is therefore suitable for power supply acceleration tests for outdoor lighting LEDs. Conclusion: The SMPS acceleration test for outdoor lighting LED can improve the availability of the product by developing an accelerated life test method that guarantees the reliability of the product.