• 제목/요약/키워드: conservative systems

검색결과 412건 처리시간 0.022초

실 매개변수 불확실성을 가진 선형시스템의 외란 감소 (Disturbance Attenuation for Linear Systems with Real Parametric Uncertainties)

  • 류석환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.362-365
    • /
    • 1994
  • This paper deals with the disturbance attenuation problem for linear systems with real parametric uncertainties. When there are time invariant parameter uncertainties whose sizes are bounded, a less conservative output feedback controller is constructed such that the closed loop system is asymptotically stable and achieves the prescribed disturbance attenuation level for all allowable parameter uncertainties. In order to demonstrate efficacy of the design method a numerical example is presented.

  • PDF

EVENTUAL SHADOWING FOR CHAIN TRANSITIVE SETS OF C1 GENERIC DYNAMICAL SYSTEMS

  • Lee, Manseob
    • 대한수학회지
    • /
    • 제58권5호
    • /
    • pp.1059-1079
    • /
    • 2021
  • We show that given any chain transitive set of a C1 generic diffeomorphism f, if a diffeomorphism f has the eventual shadowing property on the locally maximal chain transitive set, then it is hyperbolic. Moreover, given any chain transitive set of a C1 generic vector field X, if a vector field X has the eventual shadowing property on the locally maximal chain transitive set, then the chain transitive set does not contain a singular point and it is hyperbolic. We apply our results to conservative systems (volume-preserving diffeomorphisms and divergence-free vector fields).

Effect of moisture and drying time on the bond strength of the one-step self-etching adhesive system

  • Lee, Yoon;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • 제37권3호
    • /
    • pp.155-159
    • /
    • 2012
  • Objectives: To investigate the effect of dentin moisture degree and air-drying time on dentin-bond strength of two different one-step self-etching adhesive systems. Materials and Methods: Twenty-four human third molars were used for microtensile bond strength testing of G-Bond and Clearfil $S^3$ Bond. The dentin surface was either blot-dried or air-dried before applying these adhesive agents. After application of the adhesive agent, three different air drying times were evaluated: 1, 5, and 10 sec. Composite resin was build up to 4 mm thickness and light cured for 40 sec with 2 separate layers. Then the tooth was sectioned and trimmed to measure the microtensile bond strength using a universal testing machine. The measured bond strengths were analyzed with three-way ANOVA and regression analysis was done (p = 0.05). Results: All three factors, materials, dentin wetness and air drying time, showed significant effect on the microtensile bond strength. Clearfil $S^3$ Bond, dry dentin surface and 10 sec air drying time showed higher bond strength. Conclusions: Within the limitation of this experiment, air drying time after the application of the one-step self-etching adhesive agent was the most significant factor affecting the bond strength, followed by the material difference and dentin moisture before applying the adhesive agent.

All-in-one adhesive의 다층적용이 미세인장결합강도에 미치는 영향 (THE EFFECT OF MULTIPLE APPLICATION ON MICROTENSILE BOND STRENGTH OF ALL-IN-ONE DENTIN ADHESIVE SYSTEMS)

  • 손성애;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제29권5호
    • /
    • pp.423-429
    • /
    • 2004
  • The purpose of this study was to evaluate the effect of multiple application of all-in-one dentin adhesive system on microtensile bond strength using confocal laser scanning microscope and microtensile bond strength test. Flat occlusal dentin surfaces were prepared using low-speed diamond saw. In group I, Scotchbond Multipurpose (SM) was applied by manufacturer's recommendation. In group II, after Adper Prompt L-Pop was applied for 15s and light cured for 10s. the second coat was re-applied and light-cured. In group III, after light-curing the second layer. the third coat was re-applied and light-cured. Specimens bonded with a resin-composite were sectioned into resin-dentin stick for measuring the adhesive layer thickness by confocal laser scanning microscope and evaluating micro-tensile bond strength. The adhesive layers of three-step dentin adhesive system. 3 coats of Adper Prompt L-Pop had significantly thicker than SM. 2 coats of Adper Prompt L-Pop (p < 0.05). However. there was no significant differences in bond strengths between SM and 3 coats of Adper Prompt L-Pop (p > 0.05). And SM. 3 coats of Adper Prompt L-Pop had significantly higher than 2 coats of Adper Prompt L-Pop in bond strengths (p < 0.05).

치수압이 상아질 접착제의 미세전단 결합강도에 미치는 영향에 관한 In vitro 연구 (MICRO-SHEAR BOND STRENGTH TO DENTIN UNDER SIMULATED PULPAL PRESSURE)

  • 송윤정;박성호
    • Restorative Dentistry and Endodontics
    • /
    • 제29권4호
    • /
    • pp.339-345
    • /
    • 2004
  • The aim of this study was to measure and compare the micro shear bond strengths of the following dentin bonding systems to the dentin surfaces under simulated pulpal pressure: All Bond $2^{\circledR},{\;}Second^{\circledR},{\;}AdheSE^{\circledR}$, Adper Prompt $L-Pop^{\circledR}$. The occlusal surfaces of 180 extracted human molars were prepared so the dentin bonding surfaces could be exposed. The teeth were randomly assigned to 3 equal groups of 60 each and subdivided. The dentin surfaces were treated with the above mentioned bonding system and resin composite cylinders were built up under a simulated pulpal pressure when saline (Group II) or diluted bovine serum (Group III) was used as the pulpal fluid. As a control. the same procedures were performed in the dried dentin surfaces (Group I). After one day of storage in water. the micro shear bond strengths were measured using an EZ tester. Group II and III showed significantly lower shear bond strength than Group I statistically (p < 0.05). $SEbond^{\circledR}{\;}and{\;}AdheSE^{\circledR}$ showed no difference among the different dentin condition. In the Adper Prompt $L-Pop^{\circledR}$. a simulated pulpal pressure were applied to the specimens using diluted bovine serum. which showed a higher strength than the specimens in which saline was used (p < 0.05).

유한요소기법을 이용한 비보존력이 작용하는 보-기둥 구조의 다양한 제변수 변화에 따른 동적 안정성 해석 (Dynamic Stability Analysis of Nonconservative Systems for Variable Parameters using FE Method)

  • 이준석;민병철;김문영
    • 한국전산구조공학회논문집
    • /
    • 제17권4호
    • /
    • pp.351-363
    • /
    • 2004
  • 비보존력을 받는 보-부재의 질량행렬, 탄성강도행릴, circulatory비보존력의 방향변화로 인한 load correction강도행력, 그리고 Winkler 및 Pasternak지반강도행렬을 고려한 운동방정식을 유도하고 divergence 및 flutter에 의한 안정성 해석을 수행한다. 또한 내적 및 외적 감쇠계수를 운동방정식에 포함시킴으로써 감쇠효과를 고려하고, 2차 고유치문제의 해법(quadratic eigen problem solution)을 적용하여 flutter에 미치는 영향을 조사한 후, Beck's column, Leipholz's column 및 Hauger's column에 대하여 비보존력의 방향파라미터 ${\alpha}$에 대한 임계하중의 영향, 내적 및 외적 감쇠계수 및 Winkler 및 Pasternak지반에 의한 임계하중의 영향을 각각 조사한다.

수종 코어용 복합레진 수복재의 물성에 관한 연구 (A STUDY ON THE MATERIAL PROPERTIES OF VARIOUS COMPOSITE RESINS FOR CORE BUILD-UP)

  • 신수일;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제29권2호
    • /
    • pp.191-199
    • /
    • 2004
  • The purposes of this study were to estimate the material properties of the recently developed domestic composite resins for core filling material (Chemical, Dual A, Dual B;Vericom, Korea) and to compare them with other marketed foreign products (CorePaste, Den-Mat, USA;Ti-Core, Essential Dental Systems, USA;Support. SCI-Pharm. USA). Six assessments were made:working time. setting time. depth of polymerization. flexural strength. bonding strength. and marginal leakage. All items were compared to ISO standards. All domestic products satisfied the minimum requirements from ISO standards (working time:above 90 seconds. setting time:within 5 minutes). and showed significantly higher flexural strength than Core Paste. Dual A and B could. especially. reduce the setting time to 60 seconds when cured with $600mW/cm^2$ light intensity. All experimental materials showed 6 mm depth of polymerization. Bond strengths of Ti-Core and Dual B materials were significantly higher than the other materials. Furthermore. three domestic products and Ti-Core could reduce the microleakage effectively.

세균에 노출된 말초혈액 단핵구에서 Interleukin-8과 Monocyte Chemoattractant Protein-1의 형성에 관한 연구 (PRODUCTION OF INTERLEUKIN-8 AND MONOCYTE CHEMOATTRACTANT PROTEIN-1 BY PERIPHERAL BLOOD MONOCYTES STIMULATED WITH MICROBES)

  • 이정민;임미경
    • Restorative Dentistry and Endodontics
    • /
    • 제25권2호
    • /
    • pp.212-218
    • /
    • 2000
  • The recruitment of leukocytes to a site of inflammation is dependent on a complex interplay of a number of cytokines. Monocyte chemoattractant protein-1 (MCP-1) is a potent chemoattractant for monocytes, whereas interleukin-8 (IL-8) has chemotactic activity for neutrophils, lymphocytes, and basophils. The purpose of this study was to determine the effects of several microbes found in infected root canal systems on the production of inflammatoy cytokines, interleukin 8 and monocyte chemoattractant protein-1 from human peripheral blood mononuclear cells (PBMC). Monocytes isolated from peripheral blood were stimulated by group A streptococci (GAS, ATCC 19615), Enterococcus faecalis (ATCC 29212), Streptococcus mutans (ATCC 10449), Streptococcus sanguis (clinical isolate), and Candida albicans (ATCC 90029) respectively. Each of these bacteria induced dose-dependent induction in IL-8 and MCP-1 determined by ELISA. IL-8 production by each bacteria was decreased in the range of the microbe-to-PBMC ratios of 0.1-1.0. Group A streptococci was the week inducer of MCP-1 production. These results suggest that different oral pathogens induce specific dose-dependent patterns of cytokine release. Such patterns may provide a means of control of the type of immune celles particularly with regard to inflammatory leukocyte recruitment.

  • PDF

A well-balanced PCCU-AENO scheme for a sediment transport model

  • Ndengna, Arno Roland Ngatcha;Njifenjou, Abdou
    • Ocean Systems Engineering
    • /
    • 제12권3호
    • /
    • pp.359-384
    • /
    • 2022
  • We develop in this work a new well-balanced preserving-positivity path-conservative central-upwind scheme for Saint-Venant-Exner (SVE) model. The SVE system (SVEs) under some considerations, is a nonconservative hyperbolic system of nonlinear partial differential equations. This model is widely used in coastal engineering to simulate the interaction of fluid flow with sediment beds. It is well known that SVEs requires a robust treatment of nonconservative terms. Some efficient numerical schemes have been proposed to overcome the difficulties related to these terms. However, the main drawbacks of these schemes are what follows: (i) Lack of robustness, (ii) Generation of non-physical diffusions, (iii) Presence of instabilities within numerical solutions. This collection of drawbacks weakens the efficiency of most numerical methods proposed in the literature. To overcome these drawbacks a reformulation of the central-upwind scheme for SVEs (CU-SVEs for short) in a path-conservative version is presented in this work. We first develop a finite-volume method of the first order and then extend it to the second order via the averaging essentially non oscillatory (AENO) framework. Our numerical approach is shown to be well-balanced positivity-preserving and shock-capturing. The resulting scheme could be seen as a predictor-corrector method. The accuracy and robustness of the proposed scheme are assessed through a carefully selected suite of tests.

A numerical approach for assessing internal pressure capacity at liner failure in the expanded free-field of the prestressed concrete containment vessel

  • Woo-Min Cho;Seong-Kug Ha;SaeHanSol Kang;Yoon-Suk Chang
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3677-3691
    • /
    • 2023
  • Since containment building is the major shielding structure to ensure safety of nuclear power plant, the structural behavior and ultimate pressure capacity of containments must be studied in depth. This paper addresses ambiguous issue of determining free-field position for liner failure by suggesting an expanded free-field region and comparing internal pressure capacities obtained by test data, conservative assumption and suggested free-field region. For this purpose, a practical approach to determine the free-field position for the evaluation of liner tearing is carried out. The maximum principal strain histories versus internal pressure capacities among different free-field positions at various azimuths and elevations are compared with those at the equipment hatch as a conservative assumption. The comparison shows that there are considerable differences in the internal pressure capacity at liner failure within the expanded free-field region compared to the vicinity of the equipment hatch. Additionally, this study proposes an approximate correlation with conservative factors by considering the expanded free-field ranges and material characteristics to determine realistic failure criteria for liner. The applicability of the proposed correlation is demonstrated by comparing the internal pressure capacities of full-scale containment buildings following liner failure criteria according to RG 1.216 and an approximate correlation.