• 제목/요약/키워드: connectors

검색결과 548건 처리시간 0.027초

FRP-콘크리트 합성을 위한 퍼포본드 전단 연결재의 성능 평가 (Performance Evaluation of Perfobond Rib FRP Shear Connectors for Composition between FRP and Concrete)

  • 박성용;조정래;황훈희;조근희;백동열;김성태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.297-300
    • /
    • 2006
  • One of main issues of the FRP-concrete composite member is shear connection between FRP and concrete in order to secure composite behavior of FRP and concrete. To solve this problem, perfobond rib FRP shear connector is introduced for the mechanical shear connection. In this study, experimental study was carried out on the perfobond rib FRP shear connectors in order to develop the effective details of perfobond rib FRP shear connectors. Pull-out test specimens were manufactured with FRP plate with holes embedded in concrete block. Main parameters considered in this study were diameter of holes, ratio of spacing between the centres of holes to the diameter of holes, and thickness of FRP plates. Test results are discussed according to above parameters compared with other empirical expressions for steel perfobond rib connector.

  • PDF

피라미드형 전단연결재의 전단거동 (Shear Behavior of Pyramidal Shear Connectors)

  • 이경동;한상호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제4권2호
    • /
    • pp.131-137
    • /
    • 2000
  • In order to evaluate the design shear strength of composite slabs with truss-shaped shear connectors(TSC), a series of push-out tests on several types of specimens was carried out. The test results for the two parameters of bearing area and solid angle of the connector were compared to obtain the design shear force of the truss-shaped connectors. The results obtained from this study are as follows: (1) The slip-coefficients of TSC ranges from 0.87 to 3.12(${\times}10^6kgf/cm$). (2) The slip stiffness and the shear strength of TSC with $60.6cm^2$ bearing area are greater than those with $14.6cm^2$. (3) For estimating the allowable shear force of TSC, a design equation that is based on the bearing strength of the connector is suggested. (4) The mean safety factors of the critical force and the ultimate force are 2.38 and 4.62. respectively.

  • PDF

A Research on Stray-Current Corrosion Mechanism of High Voltage Cable Connector on Electrification Vehicles

  • Lee, Hwi Yong;Ahn, Seung Ho;Im, Hyun Taek
    • Corrosion Science and Technology
    • /
    • 제18권4호
    • /
    • pp.117-120
    • /
    • 2019
  • Considering the tendency of development of electrification vehicles, development and verification of new evaluation technology is needed because of new technology applications. Recently, as the battery package is set outdoors of an electric vehicle, such vehicles are exposed to corrosive environments. Among major components connected to the battery package, rust prevention of high-voltage cables and connectors is considered the most important issue. For example, if corrosion of high voltage cable connectors occurs, the corrosion durability assessment of using an electric vehicle will be different from general environmental corrosion phenomena. The purpose of this study is to investigate the corrosion mechanism of high voltage cable connectors of an electric vehicle under various driving environments (road surface vibration, corrosion environment, current conduction by stray current, etc.) and develop an optimal rust prevention solution. To improve our parts test method, we have proposed a realistic test method to reproduce actual electric vehicle corrosion issues based on the principle test.

Behavior of steel-concrete composite beam using angle shear connectors at fire condition

  • Davoodnabi, Seyed Mehdi;Mirhosseini, Seyed Mohammad;Shariati, Mahdi
    • Steel and Composite Structures
    • /
    • 제30권2호
    • /
    • pp.141-147
    • /
    • 2019
  • Fire is one of the environmental parameters affecting the structure causing element internal forces to change, as well as reducing the strength of the materials. One of the common types of floors in tall steel structures is the steel concrete composite slab. Shear connectors are used in steel and concrete composite beam in various shapes also has played significant role in a burning fire event of building with a steel concrete composite beam. The current study has reviewed the effects of temperature raising on the angle connector behavior through the use of push out tests and monotonic static force. The results have shown (1) the ductility of the samples is acceptable based on EC4 standard; (2) temperature raising has reduced the stiffness; (3) the shear ductility increment; and (4) the shear capacity reduction. Also, the amount of angle shear connector resistance has been decreased from 18.5% to 41% at ambient temperature up to $850^{\circ}C$.

Stud connection in composite structures: development with concrete age

  • Chengqian Wen;Guotao Yang
    • Steel and Composite Structures
    • /
    • 제47권6호
    • /
    • pp.729-741
    • /
    • 2023
  • As the most popular shear connection in composite structures, mature concrete has been widely investigated by considering mechanical properties of stud connectors (SCs) embedded. To further enhance the fabrication efficiency of composite structures and solve the contradiction between construction progress and structural performance, it is required to analyze the shear performance of stud connections of composite structures with different concrete ages. 18 typical vertical push-out tests were carried out on stud shear connectors at concrete ages of 7 days, 14 days, and 28 days. Also, the effects of concrete age, stud spacing and stud diameter on the shear capacity, connection stiffness and failure mode of the connectors were studied. A new relationship expression of load-slip for SCs with various concrete ages was proposed. The existing design code for the SCs shear strength was evaluated according to the experimental data, and a more practical prediction equation for the shear capacity of SCs with different concrete ages was established. A great agreement was observed between the experimental and theoretical results, which can provide a reference for engineering practices.

OVERVIEW OF FRETTING CORROSION IN ELECTRICAL CONNECTORS

  • PARK Y. W.;JUNG J. P.;LEE K. Y.
    • International Journal of Automotive Technology
    • /
    • 제7권1호
    • /
    • pp.75-82
    • /
    • 2006
  • Fretting corrosion widely known as a degradation mechanism refers to the combination of fretting wear and corrosion such as oxidation. This paper critically reviews the works published previously on fretting corrosion of electrical connectors. Various experimental approaches such as testing machines, material selection, testing environments, acceleration testing techniques and preventing methods are addressed. Future research prospects are suggested.

불완전 합성형의 처짐특성에 관한 연구 (A Study on Deflection Characteristic of Composite Girder with Incomplete Interaction)

  • 용환선;김석태;김윤환
    • 한국강구조학회 논문집
    • /
    • 제10권3호통권36호
    • /
    • pp.437-449
    • /
    • 1998
  • 합성형구조에서 콘크리트와 강재가 일체로 거동하기 위해서 전단연결재는 충분한 강성과 강도를 지니고 있어야 한다. 만약 콘크리트와 판형의 경계면에서 수직 또는, 수평방향으로 미끄러짐이 발생하지 않는다면 전단연결재는 무한강성으로 표현되어지고, 이상적으로 완전합성거동을 하게 된다. 그러나, 모든 전단연결재는 어느 정도의 범위내에서 유연성을 가지게 되며, 항상 불완전합성작용을 하게 된다. 본 논문에서는 3가지 방법에 의해서 불완전합성작용을 하는 합성형을 해석하는 실용적인 방법에 대하여 연구하였다. 미분방정식의 일반해로부터 유도된 강도매트릭스법과 경계부분의 스프링상수를 뼈대구조로 대체한 유한요소법, 가상일의 원리를 이용한 유한요소법의 3가지 방법에 의하여 합성형의 처짐특성을 고찰하였다. 또한, 불완전합성형에서 단면특성과 전단연결재의 스프링상수를 이용하여 합성형의 합성정도를 추정할수 있는 간이법을 제시하였다.

  • PDF

체결 성능 향상을 위한 FPCB 커넥터의 형상설계 (Shape Design of FPCB Connector to Improve Assembly Performance)

  • 김대영;박형서;김웅겸;표창률;김헌영
    • 대한기계학회논문집A
    • /
    • 제36권3호
    • /
    • pp.347-353
    • /
    • 2012
  • 최근 휴대폰은 스마트폰의 출연으로 다기능화가 요구되고 있으며, 각 보드의 전기적 신호를 연결시키는 커넥터는 필수 핵심 부품이 되었다. 커넥터는 많은 양의 전기신호를 처리하기 때문에 소형화, 협피치화가 필요하다. 하지만, 커넥터의 소형화 및 협피치화는 구조적 안전성을 저하시키며, 외부하중에 의한 접촉불량을 발생시킨다. 따라서 본 논문에서는 초소형 협피치 FPC 커넥터를 개발하기 위해 벤치마킹을 통한 초기설계안을 도출하였으며, 터미널 두께 0.2mm, 개수 50 개를 기준으로 하였다. 체결성능을 평가하기 위해 수치해석 모델을 구성하였으며, 다구찌 방법을 이용하여 형상 최적화를 수행하였다. 또한, 터미널의 한계수명을 예측하기 위해 피로해석을 수행하였으며, 체결 성능이 향상된 최종형상을 도출하였다.

프리캐스트 콘크리트 바닥판 교량의 전단연결부 설계 (Design of Shear connection in Full-Depth Precast Concrete Deck Bridge)

  • 장승필;심창수;김종희;김영진
    • 한국강구조학회 논문집
    • /
    • 제10권4호통권37호
    • /
    • pp.759-767
    • /
    • 1998
  • 프리캐스트 콘크리트 바닥판을 갖는 교량은 각각의 프리캐스트 바닥판에 전단연결재를 위한 흠을 두어서 강주형과 합성시키는 시스템을 갖는다. 전단연결재를 위한 홈을 무수축모르터로 채울 경우의 전단연결재 설계에 필요한 전단연결부의 강도와 강성의 산정식에 대한 해석적 검토를 수행한다. 허용응력 설계법을 프리캐스트 콘크리트 교량 바닥판에 적용할 경우에 대해 전단연결재의 배치방법을 단순교에 대해 신설과 보수의 경우로 나누어 교량 시스템에 적합하도록 제시하고 지점부 프리캐스트 바닥판의 상세를 제안한다. 강도설계 및 피로설계에 의한 설계방법을 적용할 경우에 대해서 부분합성 이론을 이용한 변수연구를 통해서 프리캐스트 콘크리트 바닥판 교량에 적합한 전단연결재의 배치방법을 제안한다. 실험 및 해석적 연구결과로부터 무수축모르터의 강도 영향을 제시하고 실제 적용시 적절한 강도기준을 제시한다.

  • PDF

컴포넌트 프레임워크 설계를 위한 실용적인 커넥터 패턴 (Practical Connector Patterns for Designing Component Frameworks)

  • 민현기;김수동
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제31권1호
    • /
    • pp.43-53
    • /
    • 2004
  • 학계와 산업계 모두 효율적인 재사용 기술인 Component-based Development(CBD)로의 전환을 받아들이고 있다. Product Line Engineering(PLE)에서의 컴포넌트 프레임워크는 컴포넌트, 커넥터와 그들의 시멘틱(Semantic)들의 집합으로 구성된다. 단순한 컴포넌트 조립 보다 반 완성 어플리케이션인 컴포넌트 프레임워크가 재사용의 잠재력이 더 크다. 그러나, 어플리케이션 개발을 위해 여러 업체에서 획득된 COTS 컴포넌트들의 연관관계, 의존관계가 서로 완벽하게 일치하지 않아, 컴포넌트 조립이나 컴포넌트 대체시 구현을 변경해야 하는 문제가 발생된다. 그러므로 커넥터는 관련된 컴포넌트들간의 상호작용 관리뿐만 아니라, 조립될 수 없는 컴포넌트들간의 문제를 보완하여 연결한다. 아직 실용적으로 사용할 수 있는 커넥터에 관한 연구 및 구체적인 해결 방안이 미흡하다. 본 논문에서는 커넥터를 정의 하기 위한 메타모델을 제시하고, 커넥터를 실용적으로 설계하고 구현할 수 있는 5개의 주요 패턴을 제시한다. 제시된 주요패턴들은 설계 지침 및 문제 해결방안을 제공하여 이를 통해 컴포넌트 프레임워크 기반의 실용적이고 효율적인 커넥터를 구성할 수 있도록 한다. 또한, 주요 커넥터 패턴의 적용 기법 및 구현을 통한 적용 사례를 제시하여 컴포넌트의 활용성과 재사용성이 증가됨을 보인다.