• Title/Summary/Keyword: confinement steel

Search Result 384, Processing Time 0.026 seconds

The effect of active and passive confining pressure on compressive behavior of STCC and CFST

  • Nematzadeh, Mahdi;Fazli, Saeed
    • Advances in concrete construction
    • /
    • v.9 no.2
    • /
    • pp.161-171
    • /
    • 2020
  • In this paper, an experimental study was conducted on the compressive behavior of steel tube confined concrete (STCC) and concrete-filled steel tube (CFST) columns with active and passive confinement. To create active confinement in the STCC and CFST specimens, an innovative method was used in this study, in which by applying pressure on the fresh concrete, the steel tube was laterally pretensioned and the concrete core was compressed simultaneously. Of the benefits of this technique are improving the composite column behavior, without the use of additives and without the need for vibration, and achieving high prestressing levels. To achieve lower and higher prestressing levels, short and long term pressures were applied to the specimens, respectively. Nineteen STCC and CFST specimens in three groups of passive, short-term active, and long-term active confinement were subjected to axial compression, and their mechanical properties including the compressive strength, modulus of elasticity and axial strain were evaluated. The results showed that the proposed method of prestressing the STCC columns led to a significant increase in the compressive strength (about 60%), initial modulus of elasticity (about 130%) as well as a significant reduction in the axial strain (about 45%). In the CFST columns, the prestressing led to a considerable increase in the compressive strength, a small effect on the initial and secant modulus of elasticity and an increase in the axial strain (about 55%). Moreover, increased prestressing levels negligibly affected the compressive strength of STCCs and CFSTs but slightly increased the elastic modulus of STCCs and significantly decreased that of CFSTs.

Suggestion for Confinement Steel Ratio of Rectangular RC Bridge Piers (사각형 철근콘크리트 교각의 심부구속철근비 제안)

  • Park, Chang-Kyu;Lee, Dae-Hyoung;Yun, Sang-Chul;Kim, Hyun-Jun;Chung, Young-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.89-92
    • /
    • 2005
  • Recently there have been occurred many loss of life and extensive damage to social infrastructures due to moderate and strong earthquakes all over the world. In this research, major design factors have been evaluated for the establishment of the rational seismic design code of rectangular RC bridge piers. It was concluded from this study that the axial force ratio and the longitudinal steel ratio should be the most important influencing design parameter for the seismic displacement ductility. However those parameters are not considered in the confinement steel ratio of the KHBDS. Thus, the objective of this study is to propose a rational design equation for transverse reinforcements of rectangular RC bridge piers. New confinement steel ratio is proposed by introducing the effect of the axial force and the longitudinal steel to the current KHBDS. It is thought that these new codes could release the rebar congestion problem in the plastic hinge region of RC bridge piers which contribute to the enhancement of constructibility and economization for RC bridge construction.

  • PDF

Effect of tube area on the behavior of concrete filled tubular columns

  • Gupta, P.K.;Verma, V.K.;Khaudhair, Ziyad A.;Singh, Heaven
    • Computers and Concrete
    • /
    • v.15 no.2
    • /
    • pp.141-166
    • /
    • 2015
  • In the present study, a Finite Element Model has been developed and used to study the effect of diameter to wall thickness ratio (D/t) of steel tube filled with concrete under axial loading on its behavior and load carrying capacity. The model is verified by comparing its findings with available experimental results. Influence of thickness and area of steel tube on strength, ductility, confinement and failure mode shapes has been studied. Strength enhancement factors, load factor, confinement contribution, percentage of steel and ductility index are defined and introduced for the assessment. A parametric study by varying length and thickness of tube has been carried out. Diameter of tube kept constant and equals to 140 mm while thickness has been varied between 1 mm and 6 mm. Equations were developed to find out the ultimate load and confined concrete strength of concrete. Variation of lateral confining pressure along the length of concrete cylinder was obtained and found that it varies along the length. The increase in length of tubes has a minimal effect on strength of tube but it affects the failure mode shapes. The findings indicate that optimum use of materials can be achieved by deciding the thickness of steel tube. A better ductility index can be obtained with the use of higher thickness of tube.

Behavior of concrete columns confined with both steel angles and spiral hoops under axial compression

  • Zhou, Chunheng;Chen, Zongping;Shi, Sheldon Q.;Cai, Liping
    • Steel and Composite Structures
    • /
    • v.27 no.6
    • /
    • pp.747-759
    • /
    • 2018
  • This study proposed a new type of concrete column that was confined with both steel angles and spiral hoops, named angle-steel and spiral confined concrete (ASCC) column. A total of 22 ASCC stub columns were tested under axial compression to investigate their behavior. For a comparison, three angle-steel reinforced concrete (ARC) stub columns were also tested. The test results indicated that ASCC column had a superior mechanical performance. The strength, ductility and energy absorption were considerably increased due to the improvement of confinement from spiral hoops. The confinement behavior and failure mechanism of ASCC column were investigated by the analysis of failure mode, load-deformation curve and section-strain distribution. Parametric studies were carried out to examine the influences of different parameters on the axial compression behavior of ASCC columns. A calculation approach was developed to predict the ultimate load carrying capacity of ASCC columns under axial compression. It was validated that the predicted results were in well agreement with the experimental results.

Nonlinear Analysis considered Confinement Effect of Precast Concrete Segment (프리캐스트 콘크리트 세그먼트의 구속효과를 고려한 비선형 해석)

  • Lee, Heon-Min;Kim, Tae-Hoon;Park, Jae-Keun;Kim, Young-Jin;Shin, Hyun-Mock
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.305-308
    • /
    • 2008
  • The purpose of this study is to propose the confinement effectiveness of precast segmental concrete that binding by lateral confining steel in the method of precast segmental concrete pridge piers construction. Generally, the confinement effect of concrete that binding by lateral confining steel is defined by the confinement effectiveness coefficient and the confinement effectiveness coefficient is defined as the ratio of area of effectively confined concrete core to area of confined concrete core. The area of effectively confined concrete core is defined by Arching action occurred on a space of lateral confinement steel and The area of confined concrete core is defined by the ratio of area of longitudinal reinforcement to area of core of section. But in case of precast segmental concrete, concrete cover that exist on top and bottom of concrete segment should be considered.

  • PDF

Confinement Effect by Plate Type Lateral Reinforcement and Investigation of the Possibility for Use of High Strength Steel Bars in Reinforced Concrete Columns (횡방향 판재에 의한 횡구속 효과 및 철근콘크리트 기둥에서 고강도 철근의 사용성 검토)

  • Cho, Young-Jae;Kim, Jin-Keun
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.643-650
    • /
    • 2012
  • The limitation of the yield strength in reinforced concrete columns is given for the effective use of high-strength steel bar, because very high-strength steel bar does not yield while concrete fails in compression. In order to overcome this limitation, it is required to increase peak strain of the concrete. The objective of this study is to examine the confinement effect of plate type lateral reinforcement in reinforced concrete columns. From this experimental study, the reinforced concrete columns confined by plate type carbon fiber sheets showed higher compressive strength and peak concrete strain comparing to the unconfined columns. The confinement effect is higher when cross-sectional type is a circular one than a square one. Moreover, the confinement effect was also higher for circular type confinement. Based on this study, high-strength steel bars with strength exceeding 800 MPa can be effectively used for reinforced concrete columns confined by plate type lateral reinforcements.

Behavior of Concrete-Filled and Tied Steel Tubular Arch Girder (콘크리트 충전 타이드 아치형 강재 합성거더의 선형 거동 분석)

  • Lee, Hak;Park, Ho;Lee, Eun-Ho;Kim, Jung-Ho;Kong, Jung-Sik
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.688-693
    • /
    • 2007
  • Nowadays various studies related with superstructure of bridges are developed and they pursuit more effective section of bridges superstructure, material and economical application of composite materials. CFT structure(Concrete Filled Steel Tubular Structure) is developed type of composite structure that concrete is filled with steel box, and the deformation of the member, stiffness and internal force will be improved by confinement effect of steel box and concrete. This paper introduces new type of girder, CFTA girder( Concrete- Filled and Tied Steel Tubular Arch Girder) which is combined with traditional CFT structure,arch effect and prestress through carrying out the structural analysis by computer programs. The computer programs which is used are ABAQCS and MIDAS, and the 12.2m girder which is applied same load and prestresses is analyzed and compared the results respectively.

  • PDF

Experiments on the Composite Action of Steel Encased Composite Column (강재매입형 합성기둥의 합성작용에 관한 실험)

  • Jung In Keun;Min Jin;Shim Chang Su;Chung Young Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.485-488
    • /
    • 2004
  • Steel encased composite columns have been used for buildings and piers of bridges. Since column section for pier is relatively larger than that of building columns, economical steel ratio need to be investigated for the required performance. Composite action between concrete and embedded steel sections can be obtained by bonding and friction. However, the behavior. of the column depends on the load introduction mechanism. Compression can be applied to concrete section, steel section and composite section. In this paper, experiments on shear strength of the steel encased composite column were performed to study the effect of confinement by transverse reinforcements, mechanical interlock by holes, and shear connectors. Shear strength obtained from the tests showed considerably higher than the design value. Confinement, mechanical interlock and stud connectors increased the shear strength and these values can be used effectively to obtain composite action of SRC columns.

  • PDF

Seismic Performance of RC Columns Confined by Outside Lateral Reinforcement (외측 횡보강재로 구속된 철근콘크리트 기둥의 내진성능)

  • Lee, Do Hyung;Oh, Jangkyun;Yu, Wan Dong;Choi, Eunsoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.3A
    • /
    • pp.189-196
    • /
    • 2012
  • In this paper, reinforced concrete columns test has been conducted under repeated lateral load reversals. The test columns have been reinforced with outside lateral confinement members in addition to transverse reinforcements. For this purpose, a strainless steel and a GFRP have been employed for the lateral confinement members. Primary parameters are types, thickness and spacing of the lateral confinement members. Experimental results reveal that columns reinforced with lateral confinement members exhibit improved ductility and energy dissipation capacity in comparison with those unreinforced. It is thus concluded that the present approach can be of a useful scheme for the seismic retrofitting of reinforced concrete columns.

Suggestion for Confinement Steel Ratio of Rectangular RC Bridge Piers (사각단면 철근콘크리트 교각의 심부구속철근비 제안)

  • Park, Chang-Kyu;Chung, Young-Soo;Yun, Sang-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.6 s.96
    • /
    • pp.749-757
    • /
    • 2006
  • Many losses of life and extensive damage of social infrastructures have occurred due to moderate and strong earthquakes all over the world. In this research various design parameters have been evaluated to develop a rational seismic design code of rectangular reinforced concrete(RC) bridge piers. It was confirmed from this study that the axial force ratio and longitudinal steel ratio were most influencing design parameters on the seismic displacement ductility from experimental results of 54 rectangular RC bridge piers, which were tested at domestic and foregin countries. However, these important parameters are not considered in the confinement steel ratio of Korea Highway Bridge Design Specification(KHBDS). The objective of this study is to propose a rational design provision for the transverse reinforcement of rectangular RC bridge piers. New confinement steel ratio is proposed by reflecting the effect of the axial force and longitudinal steel into the current code of KHBDS. furthermore, minimum transverse confinement steel ratio is also proposed to avoid a probable buckling of longitudinal reinforcing steels of RC bridge piers with a relatively low axial force. New practical code can alleviate the rebar congestion in the plastic hinge region of RC bridge pier, which contributes to construct RC bridge piers in a simple and economic way.