Experiments on the Composite Action of Steel Encased Composite Column

강재매입형 합성기둥의 합성작용에 관한 실험

  • 정인근 (중앙대학교 건설환경연구소) ;
  • 민진 (중앙대학교 토목공학과) ;
  • 심창수 (중앙대학교 토목공학과) ;
  • 정영수 (중앙대학교 토목공학과)
  • Published : 2004.11.01

Abstract

Steel encased composite columns have been used for buildings and piers of bridges. Since column section for pier is relatively larger than that of building columns, economical steel ratio need to be investigated for the required performance. Composite action between concrete and embedded steel sections can be obtained by bonding and friction. However, the behavior. of the column depends on the load introduction mechanism. Compression can be applied to concrete section, steel section and composite section. In this paper, experiments on shear strength of the steel encased composite column were performed to study the effect of confinement by transverse reinforcements, mechanical interlock by holes, and shear connectors. Shear strength obtained from the tests showed considerably higher than the design value. Confinement, mechanical interlock and stud connectors increased the shear strength and these values can be used effectively to obtain composite action of SRC columns.

Keywords