In the present study, a Finite Element Model has been developed and used to study the effect of diameter to wall thickness ratio (D/t) of steel tube filled with concrete under axial loading on its behavior and load carrying capacity. The model is verified by comparing its findings with available experimental results. Influence of thickness and area of steel tube on strength, ductility, confinement and failure mode shapes has been studied. Strength enhancement factors, load factor, confinement contribution, percentage of steel and ductility index are defined and introduced for the assessment. A parametric study by varying length and thickness of tube has been carried out. Diameter of tube kept constant and equals to 140 mm while thickness has been varied between 1 mm and 6 mm. Equations were developed to find out the ultimate load and confined concrete strength of concrete. Variation of lateral confining pressure along the length of concrete cylinder was obtained and found that it varies along the length. The increase in length of tubes has a minimal effect on strength of tube but it affects the failure mode shapes. The findings indicate that optimum use of materials can be achieved by deciding the thickness of steel tube. A better ductility index can be obtained with the use of higher thickness of tube.
Keywords
concrete filled steel tube (CFST); ductility; confinement; strength; finite element method;
Citations & Related Records
연도 인용수 순위
  • Reference
1 ACI (1999), "Building code requirements for structural concrete and commentary", Am. Concrete Inst., ACI 318-99, Detroit (USA).
2 Ellobody, E., Young, B. and Lam, D. (2006), "Behaviour of normal and high strength concrete filled compact steel tube circular stub columns", J. Constr. Steel Res., 62, 706-715.   DOI
3 Farid, A., Mohammad, A., Suliman, A. (2013), "Experimental and numerical investigation of the compressive behavior of concrete filled steel tubes (CFSTs)", J. Constr. Steel Res., 80, 429-439.   DOI
4 Giakoumelis, G. and Lam, D. (2004), "Axial capacity of circular concrete filled tube columns", J J. Constr. Steel Res., 60, 1049-1068.   DOI
5 Gupta, P.K., Sarda, S.M. and Kumar, M.S. (2007), "Experimental and computational study of concrete filled steel tubular columns under axial loads", J. Constr. Steel Res., 63, 182-193.   DOI
6 Hu, H.T., Huang, C.S., Wu, M.H. and Wu, Y.M. (2009), "Nonlinear analysis of axially loaded concrete filled tube columns with confinement effect", J. Struct. Eng., 129(10), 1322-1231.
7 Huang, C.S., Yeh, Y.K., Liu, G.Y., Hu, H.T., Tsai, K.C., Weng, Y.T., Wang, S.H. and Wu, M.H. (2002), "Axial load behavior of stiffened concrete filled steel columns", J. Struct. Eng., 128(9), 1222-1230.   DOI
8 Hsuan-Teh,, Hu, Huang, Chiung-Shiann, Ming-Hsien, and Yih-Min, Wu (2003), "Nonlinear analysis of axially loaded concrete-filled tube columns with confinement effect", J. Struct. Eng., 129(10), 1322-1329.   DOI
9 Liang, Q.Q. and Sam, F. (2009), "Nonlinear analysis of circular concrete filled steel tubular short columns under axial loading", J. Constr. Steel Res., 65, 2186-2196.   DOI   ScienceOn
10 Liu, J., Sumei, Z., Xiaodong, Z. and Lanhui, G. (2009), "Behaviour and strength of circular tube confined reinforced concrete columns", J. Constr. Steel Res., 65, 1447-1458.   DOI
11 Mahamed Mahmoud El- Heweity (2012), "On the performance of circular concrete filled high strength steel columns under axial loading", Alexandria Eng. J., 1-12.
12 Mander, J.B., Priestley, M.J.N. and Park, R. (1988), "Theoritical stress-strain model for confined concrete", J. Struct. Eng., 114(8), 1804-1830.   DOI
13 O'shea, Martin, D. and Bridge Russell, Q. (2000), "Design of circular thin walled concrete filled steel tubes", J. Struct. Eng., 126(11), 1295-1303.   DOI
14 Oliveira, W.L.A., Nardin, S.D., Debs, A.L.H.C.E. and Debs, M.K.E. (2009), "Influence of concrete strength and length/diameter on the axial capacity of CFT columns", J. Constr. Steel Res., 65, 2103-2110.   DOI
15 Richart, F.E., Brandzaeg, A. and Brown, R.L. (1928), "A study of the failure of concrete under combined compressive stresses", Bull185, Champaign (IL, USA); University of Illinios Engineering Experimental station.
16 Shams, M. and Saadeghvaziri, M.A. (1999), "Nonlinear response of concrete filled steel tubular columns under axial loading", ACI Struct. J., 96(6), 1009-1018.
17 Saenz, L.P. (1964), "Discussion of 'Equation for the stress-strain curve of concrete' by P.Desayi, and S. Krishnan", J. Am. Concrete Inst., 61, 1229-1264.
18 Sakino, K., Nakahara, H., Morino, S. and Nishiyama, I. (2004), "Behavior of centrally loaded concrete filled steel tube short columns", J. Struct. Eng., 130(2), 180-188.   DOI
19 Schneider, S.P. (1998), "Axially loaded concrete filled steel tubes", J. Struct. Eng., 124(10), 1125-1138.   DOI