• 제목/요약/키워드: confined spaces

검색결과 67건 처리시간 0.018초

밀폐공간 종류별 유해가스 발생 농도 평가 (Exposure Assessment of Hazardous gases in Confined Spaces)

  • 박현희;유계묵;함승헌;정광재;신민아;이구용;장경조;윤충식
    • 한국산업보건학회지
    • /
    • 제19권4호
    • /
    • pp.381-389
    • /
    • 2009
  • Confined spaces are inherently dangerous workplace and many fatal and nonfatal accidents have been reported. Even though these accidents occur in various kinds of confined spaces, there has rarely been reported on the health hazard agent, i.e., the types of gases and their concentration ranges. Therefore in this study, we evaluated several toxic and asphyxiating gas concentrations in various confined spaces. We surveyed 57 manholes, 3 sewage treatment plants, 2 yellow radish manufacturing companies and 7 barges to measure the concentrations of oxygen($O_2$), hydrogen sulfide($H_2S$), carbon monoxide(CO), ammonia($NH_3$). Lower Explosion Limits(LEL) and Volatile Organic Compounds (VOCs). Those four types of confined spaces occupies 56% of accidents during last 9 years in Korea. In 57 manholes, the concentration varied according to the types of manholes; rainfall and sewage, and by location; residential and industrial areas. Sewage manhole in industrial area was evaluated as the most hazardous than other types of manhole like rainfall manholes, residential sewage manholes. The highest $H_2S$ concentration and the lowest $O_2$ concentration at sewage manhole in industrial area were 300 ppm, 8.7% respectively. In 3 sewage treatment plants, $H_2S$ and $NH_3$ concentrations were reached up to the 500 ppm and 200 ppm respectively. Two yellow radish manufacturing companies showed the concentrations of 316 ppm, 505.2 ppm, 90 ppm and 15.7% for $H_2S$, CO, VOCs and $O_2$, respectively. Seven barges showed 15.9%~20.9% oxygen concentration. Gas species and concentration ranges varied by the types and location of confined spaces; CO, $H_2S$, $O_2$ could be hazardous in manhole, especially manhole connected to sewage plants. CO, $H_2S$, LEL, $O_2$, $NH_3$ should be controlled in sludge silo and sluge pumping confined spaces in sewage treatment plant. The activity of lifting out radish from the storage tank was evaluated more hazardous rather than the other activities in yellow radish manufacturing industry. The employers must conduct the survey to identify all possible confined spaces in their local workplace prior to performing the tasks. At the national level to reduce the accidents in the confined spaces, we suggest that systemic approach and active education program including possible hazards, standard operation procedures, ventilation plan, and personal protective equipment in confined spaces should be implemented.

밀폐공간 질식재해 발생현황 고찰 및 예방에 관한 연구 (A Study on Asphyxiation Accidents occurred in the confined space, and their Prevention)

  • 권부현
    • 대한안전경영과학회지
    • /
    • 제18권3호
    • /
    • pp.47-54
    • /
    • 2016
  • A confined space means places where the risk of damage to health caused by lack of oxygen or hazardous gases in inadequate ventilation conditions and the risk of fire and explosion caused by flammable substances. Asphyxiation accidents in a confined space occured every year and also occurred more than two people at the same time. In this study, we surveyed the domestic statistical data occurred the lack of oxygen in confined space for the last 10 years(2006-2015) and, analyzed the accident by industries sector, workplace size etc. 17 fatal work accidents that occurred in confined spaces in Korea between 2013 and 2015 were investigated and analyzed using the database of the KOSHA and suggested interventions to minimize asphyxiation accidents in confined spaces. This paper is expected to be used to establish interventions planning and training as a preventive measures in workplace having confined spaces.

국외 질식재해 예방규정 비교를 통한 국내 규정 개선방안 (Comparison and Improvement of Domestic and Foreign Regulations for the Prevention of Suffocation Accidents)

  • 임대성;이승길;김치년;조기홍;이광용
    • 한국산업보건학회지
    • /
    • 제31권1호
    • /
    • pp.83-93
    • /
    • 2021
  • Objectives: 'Confined space' was only defined in the Safety and Health Regulations as a place where oxygen deficiency and hydrogen sulfide must be dealt with at the time of the initial enactment (1982). The danger of fire and explosion were added in 2003. We will compare and review the regulations related to confined space work under the current safety and health rules alongside regulations in other countries and prepare a plan to improve the system through enhanced clarity and execution. Methods: In a comparison of systems for the prevention of suffocation in confined spaces in major countries (Germany, United States, Japan) different concepts of the definition of confined spaces in different countries apparently due to differences in each country's legal implementation system, accident analysis methods, the status of safety and health implementation in workplaces, the precautions against actual confined space work, and the definition of confined spaces were found to be not much different between Korea and the other foreign countries. Results: In the case of Germany and the United States, a confined space is defined as a contextual concept rather than a place, so more careful attention is needed from operators or enclosed space managers as it is often necessary to judge the actual workplace. In the case of Korea and Japan, the interior of the place is mainly defined as a place, especially in the case of Japan, which concentrates on oxygen deficiency and hydrogen sulfide poisoning. Conclusions: For measures to improve regulations on the prevention of suffocation accidents in Korea, I would like to propose three major measures to improve the system in the rules on domestic industrial safety and health standards. It is necessary to prepare and provide a guide to ensure that the 18 types of confined spaces currently defined as confined spaces are clearly understood by field management supervisors or workers.

Effects of Job Satisfaction, Organizational Support and Risk Perception on Safety Consciousness in Confined Space Workers

  • Kim, Yang Rae;Jeong, Byung Yong;Park, Myoung Hwan
    • 대한인간공학회지
    • /
    • 제36권3호
    • /
    • pp.245-254
    • /
    • 2017
  • Objective: This study aims to investigate the effects of organizational support, risk perception and job satisfaction on safety consciousness in confined space works. Background: Confined space works are rated as hazardous works with high injury frequency and fatalities. But there were few researches for the occupational injury of the confined space workers. Method: Questionnaire survey targeting 236 workers working in confined spaces were carried out to construct the structural equation model on safety consciousness. The participants were all male workers, and they install and maintain or clean facilities mainly in the confined spaces. Results: A structural equation model for safety consciousness was proposed, and validated based on perceived organizational support, risk perception and job satisfaction factors. Perceived 'organizational support' contributed significantly to 'worker's safety consciousness' both directly and indirectly. Also, perceived 'worker's safety consciousness' was also affected by perceived 'job satisfaction' and 'risk perception'. In terms of magnitude of relationships, the direct effect of perceived 'job satisfaction' on 'worker's safety consciousness' was the greatest among the interrelationships among latent factors. Conclusion: Workers' safety consciousness can function as a leading indicator for safety and hazard prevention of workers. Application: The results can be used in developing safety prevention programs for confined space workers.

모조선소의 밀폐된 작업장에서의 공기중 용접흄 및 중금속 농도에 관한 조사 연구 (A study on Airborne Concentration of Welding Fumes and Metals in Confined Spaces of a Shipyard)

  • 곽영순;백남원
    • 한국산업보건학회지
    • /
    • 제7권1호
    • /
    • pp.113-131
    • /
    • 1997
  • This study was performed to evaluate the exposure levels of worker exposed to welding fume and metals in confined spaces of a shipyard. The airborne concentration of welding fumes and metal elements in confined spaces were compared with those in open working areas. Results of the study were as follows. 1. The geometric mean of welding fume concentration in a confined space was $16.6mg/m^3$, which contained $3.9mg/m^3$ Fe, $1.2mg/m^3$ Mg, $0.8mg/m^3$ Zn, $0.008mg/m^3$ Cu, $0.008mg/m^3$ Pb, $0.005mg/m^3$ Ni, $0.003mg/m^3$ Cr, $0.003mg/m^3$ Cd. The geometric mean of welding fume concentration in open working areas was $5.2mg/m^3$, which contained $1.1mg/m^3$ Fe, $0.3mg/m^3$ Mg, $0.3mg/m^3$ Zn, $0.004mg/m^3$ Cu, $0.008mg/m^3$ Pb, $0.005mg/m^3$ Ni, $0.003mg/m^3$ Cr, $0.0003mg/m^3$ Cd. The geometric mean of welding fume concentration in confined spaces was 3,2 times higher than that in open working areas. The geometric mean concentrations of such metals as Fe, Mg, Zn, or Cu within fume in confined spaces were 2-4 times higher than those in open working areas, while little difference made such metals as Pb, Ni, Cr, Cd. 2. In 32 samples out of a total of 39 samples (82.1%) collected in confined spaces, the concentrations of welding fume exceeded TLV. while so did 19 samples out of 33 samples (57.6%) in open working areas. As for the concentrations of metals in welding flume from confined spaces, Fe exceeded TLV in 14 out of a total of 38 samples (36.8%), Mn exceeded TLV in 23 out of a total of 38 samples (60.5%). As for the concentration of metals in welding fume from open working areas, Fe exceeded TLV in 3 out of a total of 34 samples (8.8%), Mn exceeded TLV in 6 out of a total of 34 samples (17.6%). Considering additive effect among metals, in 31 out of a total of 39 samples (79.5%) collected in confined spaces, the concentrations of welding fume exceeded TLV, while so did 14 out of 38 samples (55.6%) in open working areas. 3. In respect of base metal and welding type the concentration of total welding fume by $CO_2$ gas W./mild steel was the highest, followed by semiauto MMA/mild steel, then followed by TIG or $CO_2$ gas W./stainless steel. ; as for concentration of metal within fume, a decreasing order was Fe, Zn, Mn, and Pb in $CO_2$ gas W./mild steel and semiauto MMA/mild steel, but Fe, Mn, Cr, and Ni in TIG or $CO_2$ gas W./stainless steel. 4. In case of welding base metal covered by paint, contents of Zn within red paint chip and within gray paint chip were 14.0% and 0.08% respectively, which showed a little difference, while the airborne concentrations of Zn within fume during welding base metal covered red paint and gray paint were $1.351mg/m^3$ and $1.018mg/m^3$ respectively, which showed little difference. As for Pb, contents of red paint chip and gray paint chip were 0.14% and 0.08% respectively, and the airborne concentrations within fume during welding base metal covered red paint and gray paint were $0.009mg/m^3$ and $0.007mg/m^3$ respectively, both of which showed little difference.

  • PDF

IoT 기술을 활용한 밀폐공간에서의 사고 예방 연구 (Accident Prevention in Confined Space Using IoT Technology)

  • 최유정;최훈
    • 한국정보통신학회논문지
    • /
    • 제22권9호
    • /
    • pp.1159-1164
    • /
    • 2018
  • 최근 다양한 분야에서 사물 인터넷 활용이 늘고 있다. 특히 갑작스럽게 발생하는 재난재해 분야에서는 지속적 감시가 가능한 사물 인터넷의 역할이 매우 커지고 있으며, 이로 인해 사람들의 삶의 질 또한 크게 향상되고 있다. 따라서 본 연구에서는 밀폐공간의 특성과 환경적 위험성에 대해 살펴보고, 현재 상용화되고 있는 사물 인터넷 기술에 대한 검토가 이루어질 것이다. 밀폐공간에서의 사고는 다른 장소에 비해 매우 높게 나타나며, 사고를 예측하기 매우 어렵다. 이에 최근에는 사물인터넷을 활용한 밀폐공간에서의 사고를 예방하려는 다양한 시도가 나타나고 있다. 특히, 밀폐공간에서 발생할 수 있는 다양한 가스를 센서를 활용하여 탐지하고 이를 실시간으로 근로자에게 전송함으로써 사전에 위험을 감지하여 위험을 최소화할 수 있도록 하고 있다. 본 연구에서는 밀폐공간에서의 사고 예방을 위한 사물인터넷을 활용 사례를 살펴보고 이를 통해 사물인터넷을 활용한 효율적인 재난재해 예방 방안을 제시한다.

소방공무원의 비화재 밀폐공간 구조·구급 활동 중 질식 및 중독재해 사례 분석 (Fire fighters' Asphyxiation Incidents during Confined Space Rescue in Korea)

  • 이주희;강태선
    • 한국산업보건학회지
    • /
    • 제29권4호
    • /
    • pp.590-602
    • /
    • 2019
  • Objectives: This study was conducted to prevent asphyxiation of firefighters during confined space rescue. The specific purpose was to identify the magnitude of the problem, identify the cause of the accidents, and suggest measures to ensure safety of confined space rescues. Methods: We collected data from National Fallen Firefighters Memorial, press releases, and other sources In order to identify the current situation of asphyxiation incidents among firefighters from 1945 to 2019. In addition, an incident investigation was conducted for each case, and the processes, causes, and control measures of the incidents were described as a narrative data entry. Results: Over the past 73 years, eight incidents involving firefighter in Korea have occurred. In these incidents, five firefighters were killed, and eight were injured. The confined spaces incidents occurred were water supply tanks, wastewater treatment tanks, pickling pits, septic tanks, and more. The causes were three cases of hydrogen sulfide poisoning, one of oxygen deficiency, one of carbon monoxide poisoning, and three unclassifiable asphyxiations. The people in need were all workers in various industries. Conclusions: The number of firefighters' deaths and injuries during rescues in confined spaces was severe and the risks have not been completely eliminated. By establishing and implementing a precise incident investigation system, according control measures should be initiatedin order to prevent a recurrence of the same type of disaster and reflected in the SOP. In particular, due to the high risk of occurrence at workplaces, cooperation between fire and rescue authority and relevant agencies such as the Ministry of Employment and Labor and the KOSHA should be strengthened.

A Novel Simulation Architecture of Configurational-Bias Gibbs Ensemble Monte Carlo for the Conformation of Polyelectrolytes Partitioned in Confined Spaces

  • Chun, Myung-Suk
    • Macromolecular Research
    • /
    • 제11권5호
    • /
    • pp.393-397
    • /
    • 2003
  • By applying a configurational-bias Gibbs ensemble Monte Carlo algorithm, priority simulation results regarding the conformation of non-dilute polyelectrolytes in solvents are obtained. Solutions of freely-jointed chains are considered, and a new method termed strandwise configurational-bias sampling is developed so as to effectively overcome a difficulty on the transfer of polymer chains. The structure factors of polyelectrolytes in the bulk as well as in the confined space are estimated with variations of the polymer charge density.

격실 내 장애물이 폭압에 의한 인원 피해에 미치는 영향 (The Effect of Obstacles in a Compartment on Personnel Injury Caused by Blast)

  • 박성준
    • 한국시뮬레이션학회논문지
    • /
    • 제26권3호
    • /
    • pp.1-11
    • /
    • 2017
  • 격실 내부에서의 폭발로 인한 인원의 피해를 분석하였다. 특히 격실 내에서 폭압 전파에 영향을 미치는 돌출된 장애물의 유무에 따른 인원 피해를 비교하였다. 격실 내에 장애물이 없는 경우에 경험적 고속처리모델을 이용하여 폭압을 예측할 수 있다. 하지만 격실 내부에서는 폭압 프로파일이 개활지에서와 달리 복잡하며 의자와 같은 구조물이 존재하는 경우에는 경험적 고속처리모델 적용이 불가하다. 따라서 장애물이 있는 격실 내부 폭압은 유한요소해석을 이용해 획득하였다. 또한 개활지의 폭압 프로파일을 기준으로 개발된 Friedlander 압력-충격량 곡선을 격실 내부에서의 복잡한 폭압 전파로 인해 피해평가에 적용할 수 없어, Axelsson 단자유도 모델을 적용하여 인원 피해를 분석하였다. 장애물이 있는 경우 인원의 흉벽 속도는 26에서 76 퍼센트(%) 만큼 감소되었으며 격실내 인원피해 또한 감소되었다.