• Title/Summary/Keyword: cone-beam computed tomography

Search Result 789, Processing Time 0.026 seconds

Comparison of cone beam CT and conventional CT in absorbed and effective dose (Cone beam CT와 일반 CT의 흡수선량 및 유효선량 비교평가)

  • Kim, Sang-Yeon;Han, Jin-Woo;Park, In-Woo
    • Imaging Science in Dentistry
    • /
    • v.38 no.1
    • /
    • pp.7-15
    • /
    • 2008
  • Purpose: This study provides comparative measurements of absorbed and effective doses for newly developed cone beam computed tomography (CT) in comparison with these doses for conventional CT. Materials and Methods: Thermoluminescent dosimeter rods (TLD rod: GR-200, Thermo Fisher Scientific Inc., Waltham, MA, USA) were placed at 25 sites throughout the layers of Male ART Head and Neck Phantom (Radiology Support Devices Inc., Long Beach, USA) for dosimetry. Implagraphy, DCT Pro (Vatech Co., Hwasung, Korea) units, SCT-6800TXL (Shimadzu Corp., Kyoto, Japan), and Crane x 3+(Soredex Orion Corp., Helsinki, Finland) were used for radiation exposures. Absorption doses were measured with Harshaw 3500TLD reader (Thermo Fisher Scientific Inc., Waltham, MA, USA). Radiation weighted doses and effective doses were measured and calculated by 2005 ICRP tissue weighting factors. Results: Absorbed doses in Rt. submandibular gland were 110.57 mGy for SCT 6800TXL (Implant), 24.56 mGy for SCT 6800TXL (3D), 22.39 mGy for Implagraphy 3, 7.19 mGy for DCT Pro, 5.96 mGy for Implagraphy 1, 0.70 mGy for Cranex 3+. Effective doses $(E_{2005draft)$ were 2.551 mSv for SCT 6800TXL (Implant), 1.272 mSv for SCT 6800TXL (3D), 0.598 mSv for Implagraphy 3, 0.428 mSv for DCT Pro and 0.146 mSv for Implagraphy 1. These are 108.6, 54.1, 25.5, 18.2 and 6.2 times greater than panoramic examination (Cranex 3+) doses (0.023mSv). Conclusion: Cone beam CT machines recently developed in Korea, showed lower effective doses than conventional CT. Cone beam CT provides a lower dose and cost alternative to conventional CT, promising to revolutionize the practice of oral and maxillofacial radiology.

  • PDF

Characterization of Cone-beam Computed Tomography System for Small Animal (콘빔형 소동물용 전산화단층촬영(CT) 장치의 성능평가)

  • Kang, Hyeong-Geun;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • A cone-beam computed tomography (CT) system for a small animal has been widely used in the bio-medical application. This paper introduced simple methods for evaluating a cone-beam CT system using a simple tungsten wire phantom of 10{$\mu}m$ diameter and a water phantom. Slice images and three-dimensional tomography images were obtained through 360 projection views per one sample rotation under stable X-ray tube conditions for a long running time. The cone-beam CT system at a position of a 1.07 magnification showed a spatial frequency of 13.78 lp/mm ($36.2{\mu}m$ spatial resolution) and gave a CNR of 10.33 and a S/N of 5.87 under a tube voltage of 80kV.

Effect of field-of-view size on gray values derived from cone-beam computed tomography compared with the Hounsfield unit values from multidetector computed tomography scans

  • Shokri, Abbas;Ramezani, Leila;Bidgoli, Mohsen;Akbarzadeh, Mahdi;Ghazikhanlu-Sani, Karim;Fallahi-Sichani, Hamed
    • Imaging Science in Dentistry
    • /
    • v.48 no.1
    • /
    • pp.31-39
    • /
    • 2018
  • Purpose: This study aimed to evaluate the effect of field-of-view (FOV) size on the gray values derived from cone-beam computed tomography (CBCT) compared with the Hounsfield unit values from multidetector computed tomography (MDCT) scans as the gold standard. Materials and Methods: A radiographic phantom was designed with 4 acrylic cylinders. One cylinder was filled with distilled water, and the other 3 were filled with 3 types of bone substitute: namely, Nanobone, Cenobone, and Cerabone. The phantom was scanned with 2 CBCT systems using 2 different FOV sizes, and 1 MDCT system was used as the gold standard. The mean gray values(MGVs) of each cylinder were calculated in each imaging protocol. Results: In both CBCT systems, significant differences were noted in the MGVs of all materials between the 2 FOV sizes(P<.05) except for Cerabone in the Cranex3D system. Significant differences were found in the MGVs of each material compared with the others in both FOV sizes for each CBCT system. No significant difference was seen between the Cranex3D CBCT system and the MDCT system in the MGVs of bone substitutes on images obtained with a small FOV. Conclusion: The size of the FOV significantly changed the MGVs of all bone substitutes, except for Cerabone in the Cranex3D system. Both CBCT systems had the ability to distinguish the 3 types of bone substitutes based on a comparison of their MGVs. The Cranex3D CBCT system used with a small FOV had a significant correlation with MDCT results.

Detection of root perforations using conventional and digital intraoral radiography, multidetector computed tomography and cone beam computed tomography

  • Shokri, Abbas;Eskandarloo, Amir;Noruzi-Gangachin, Maruf;Khajeh, Samira
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.1
    • /
    • pp.58-67
    • /
    • 2015
  • Objectives: This study aimed to compare the accuracy of conventional intraoral (CI) radiography, photostimulable phosphor (PSP) radiography, cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) for detection of strip and root perforations in endodontically treated teeth. Materials and Methods: Mesial and distal roots of 72 recently extracted molar were endodontically prepared. Perforations were created in 0.2, 0.3, or 0.4 mm diameter around the furcation of 48 roots (strip perforation) and at the external surface of 48 roots (root perforation); 48 roots were not perforated (control group). After root obturation, intraoral radiography, CBCT and MDCT were taken. Discontinuity in the root structure was interpreted as perforation. Two observers examined the images. Data were analyzed using Stata software and Chi-square test. Results: The sensitivity and specificity of CI, PSP, CBCT and MDCT in detection of strip perforations were 81.25% and 93.75%, 85.42% and 91.67%, 97.92% and 85.42%, and 72.92% and 87.50%, respectively. For diagnosis of root perforation, the sensitivity and specificity were 87.50% and 93.75%, 89.58% and 91.67%, 97.92% and 85.42%, and 81.25% and 87.50%, respectively. For detection of strip perforation, the difference between CBCT and all other methods including CI, PSP and MDCT was significant (p < 0.05). For detection of root perforation, only the difference between CBCT and MDCT was significant, and for all the other methods no statistically significant difference was observed. Conclusions: If it is not possible to diagnose the root perforations by periapical radiographs, CBCT is the best radiographic technique while MDCT is not recommended.

Detection of different foreign bodies in the maxillofacial region with spiral computed tomography and cone-beam computed tomography: An in vitro study

  • Abolvardi, Masoud;Akhlaghian, Marzieh;Shishvan, Hadi Hamidi;Dastan, Farivar
    • Imaging Science in Dentistry
    • /
    • v.50 no.4
    • /
    • pp.291-298
    • /
    • 2020
  • Purpose: The detection and exact localization of penetrating foreign bodies are crucial for the appropriate management of patients with dentoalveolar trauma. This study compared the efficacy of cone-beam computed tomography (CBCT) and spiral computed tomography (CT) scans for the detection of different foreign bodies composed of 5 frequently encountered materials in 2 sizes. The effect of the location of the foreign bodies on their visibility was also analyzed. Materials and Methods: In this in vitro study, metal, tooth, stone, glass, and plastic particles measuring 1×1×1 mm and 2×2×2 mm were prepared. They were implanted in a sheep's head in the tongue muscle, nasal cavity, and at the interface of the mandibular cortex and soft tissue. CBCT and spiral CT scans were taken and the visibility of foreign bodies was scored by 4 skilled maxillofacial radiologists who were blinded to the location and number of foreign bodies. Results: CT and CBCT were equally accurate in visualizing metal, stone, and tooth particles of both sizes. However, CBCT was better for detecting glass particles in the periosteum. Although both imaging modalities visualized plastic particles poorly, CT was slightly better for detecting plastic particles, especially the smaller ones. Conclusion: Considering the lower patient radiation dose and cost, CBCT can be used with almost equal accuracy as CT for detecting foreign bodies of different compositions and sizes in multiple maxillofacial regions. However, CT performed better for detecting plastic particles.

Validation and comparison of volume measurements using 1 multidetector computed tomography and 5 cone-beam computed tomography protocols: An in vitro study

  • Juliana Andrea Correa, Travessas;Alessandra Mendonca, dos Santos;Rodrigo Pagliarini, Buligon;Nadia Assein, Arus;Priscila Fernanda Tiecher, da Silveira;Heraldo Luis Dias, da Silveira;Mariana Boessio, Vizzotto
    • Imaging Science in Dentistry
    • /
    • v.52 no.4
    • /
    • pp.399-408
    • /
    • 2022
  • Purpose: The purpose of this study was to compare volume measurements obtained using 2 image software packages on Digital Imaging and Communications in Medicine (DICOM) images acquired from 1 multidetector computed tomography and 5 cone-beam computed tomography devices, using different protocols for physical volume measurements. Materials and Methods: Four pieces of bovine leg were prepared. Marrow was removed from 3 pieces, leaving cortical bone exposed. The resulting space of 1 piece was filled with water, another was filled with propylene glycol, and the third was left unfilled. The marrow in the fourth sample was left fully intact. Volume measurements were obtained after importing DICOM images into the Dolphin Imaging 11.95 and ITK-SNAP software programs. Data were analyzed using 3-way analysis of variance with a generalized linear model to determine the effects of voxel size, software, and content on percentage mean volume differences between tomographic protocols. A significance level of 0.05 was used. Results: The intraclass correlation coefficients for intraobserver and interobserver reliability were, respectively, 0.915 and 0.764 for the Dolphin software and 0.894 and 0.766 for the ITK-SNAP software. Three sources of statistically significant variation were identified: the interaction between software and content (P=0.001), the main effect of content (P=0.014), and the main effect of software (P=0.001). Voxel size was not associated with statistically significant differences in volume measurements. Conclusion: Both content and software influenced the accuracy of volume measurements, especially when the content had gray values similar to those of the adjacent tissues.

Very deep super-resolution for efficient cone-beam computed tomographic image restoration

  • Hwang, Jae Joon;Jung, Yun-Hoa;Cho, Bong-Hae;Heo, Min-Suk
    • Imaging Science in Dentistry
    • /
    • v.50 no.4
    • /
    • pp.331-337
    • /
    • 2020
  • Purpose: As cone-beam computed tomography (CBCT) has become the most widely used 3-dimensional (3D) imaging modality in the dental field, storage space and costs for large-capacity data have become an important issue. Therefore, if 3D data can be stored at a clinically acceptable compression rate, the burden in terms of storage space and cost can be reduced and data can be managed more efficiently. In this study, a deep learning network for super-resolution was tested to restore compressed virtual CBCT images. Materials and Methods: Virtual CBCT image data were created with a publicly available online dataset (CQ500) of multidetector computed tomography images using CBCT reconstruction software (TIGRE). A very deep super-resolution (VDSR) network was trained to restore high-resolution virtual CBCT images from the low-resolution virtual CBCT images. Results: The images reconstructed by VDSR showed better image quality than bicubic interpolation in restored images at various scale ratios. The highest scale ratio with clinically acceptable reconstruction accuracy using VDSR was 2.1. Conclusion: VDSR showed promising restoration accuracy in this study. In the future, it will be necessary to experiment with new deep learning algorithms and large-scale data for clinical application of this technology.

Three-dimensional evaluation of the relationship between nasopharyngeal airway shape and adenoid size in children

  • Oh, Kyung-Min;Kim, Min-Ah;Youn, Jong-Kuk;Cho, Hyung-Jun;Park, Yang-Ho
    • The korean journal of orthodontics
    • /
    • v.43 no.4
    • /
    • pp.160-167
    • /
    • 2013
  • Objective: To evaluate the shapes and sizes of nasopharyngeal airways by using cone-beam computed tomography and to assess the relationship between nasopharyngeal airway shape and adenoid hypertrophy in children. Methods: Linear and cross-sectional measurements on frontal and sagittal cross-sections containing the most enlarged adenoids and nasopharyngeal airway volumes were obtained from cone-beam computed tomography scans of 64 healthy children ($11.0{\pm}1.8$ years), and the interrelationships of these measurements were evaluated. Results: On the basis of frontal section images, the subjects' nasopharyngeal airways were divided into the following 2 types: the broad and long type and the narrow and flat type. The nasopharyngeal airway sizes and volumes were smaller in subjects with narrow and flat airways than in those with broad and long airways (p < 0.01). Children who showed high adenoid-nasopharyngeal ratios on sagittal imaging, indicating moderate to severe adenoid hypertrophy, had the narrow and flat type nasopharyngeal airway (p < 0.01). Conclusions: Cone-beam computed tomography is a clinically simple, reliable, and noninvasive tool that can simultaneously visualize the entire structure and a cross section of the nasopharyngeal airway and help in measurement of adenoid size as well as airway volume in children with adenoid hypertrophy.

Accuracy and reproducibility of landmark of cone beam computed tomography (CT) synthesized cephalograms (Cone beam computed tomography로 합성된 두부규격 방사선사진에서의 각 계측점의 정확도와 재현성에 관한 연구)

  • Kwon, Dae-Keun;Min, Seung-Ki;Jun, In-Chul;Paeng, Jun-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.2
    • /
    • pp.78-86
    • /
    • 2010
  • Introduction: Cone beam computed tomography (CBCT) has various advantages and is used favorably in many fields in dentistry. Especially, CBCT is being used as basic diagnostic tool for 3-dimensional analysis in orthognathic patient. Two-dimensional cephalograms can be synthesized from CBCT digital imaging and communications in medicine (DICOM) data. In this study, conventional cephalograms and CBCT were taken simultaneously, and representative landmarks were located and analyzed in its accuracy and reproducibility. Materials and Methods: Ten patients who had orthognathic surgery in Wonkwang University Daejeon Dental Hospital participated in this study. For each patient, CBCT and conventional cephalogram was taken. By using Ondemand (Cybermad, Korea), 2-dimensional cephalograms was established on CBCT. In addition, 19 landmarks were designated and measured by 3 orthodontists twice a week. After these landmarks were transferred to a coordinate, distance of landmark and axis, standard error, distribution degree were measured, compared and analyzed. Results: Comparing the CT ceph group and conventional cephalogram group, CT ceph group had shown shorter distance of landmark and axis in S, Hinge axis, Bpt, Ba, Or, Corpus left. Standard error of the mean shows that CT ceph group has better reproducibility in Or, Corpus left, Hinge axis at X axis and Na, U1R, U1T, Bpt, PNS, Ba Corpus left, Hinge axis at Y axis. In both groups, mean error was less than 1.00 mm, no significant difference were found between CT ceph group and conventional cephalogram group in all measurements. Furthermore, comparing two groups, each 17 landmarks out of 19 had its characteristic in distribution degree. Conclusion: No significant difference were found between CBCT composed cephalographic radiograph and conventional cephalograghic radiograph, clinical application may be possible if improved.

Cone-beam computed tomography assessment of mandibular asymmetry in unilateral cleft lip and palate patients (편측성 구순 구개열 환자의 하악 비대칭에 대한 cone-beam computed tomography를 이용한 평가)

  • Veli, Ilknur;Uysal, Tancan;Ucar, Faruk Izzet;Eruz, Murat;Ozer, Torun
    • The korean journal of orthodontics
    • /
    • v.41 no.6
    • /
    • pp.431-439
    • /
    • 2011
  • Objective: To determine whether there is any difference between the cleft and non-cleft sides of the mandible in unilateral cleft lip and palate (UCLP) patients, or the right and left sides in control patients; and to determine if there is any difference between the mandibular asymmetry of UCLP patients and that of control patients. Methods: We examined cone-beam computed tomography (CBCT) scans of 15 patients with UCLP and 15 age- and gender-matched control patients. We evaluated 8 linear, 3 surface, and 3 volumetric measurements and compared the cleft/non-cleft sides of UCLP patients and the right/left sides of controls. Results: There were no statistically significant gender differences in any linear, surface, or volumetric measurement. The single significant side-to-side difference in UCLP patients was a longer coronoid unit on the cleft side than on the non-cleft side ($p$ = 0.046). Body volume was significantly lower in the UCLP group than in the control group ($p$ = 0.008). Conclusions: In general, UCLP patients have symmetrical mandibles, although the coronoid unit length is significantly longer on the cleft side than on the non-cleft side. UCLP patients and controls differed only in body volume.