The Effect of Mineral Admixtures' Type on the Chloride Penetration Resistance of Concrete (콘크리트의 염화물 침투저항성에 미치는 무기질 혼화재 종류의 영향)

  • Kim, Young-Jin;Kim, Dong-Seok;Yu, Jae-Kang
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.802-805
    • /
    • 2004
  • This study was performed to investigate the effect of mineral admixture' type and replacement ratios on the chloride penetration resistance of concrete which was immersed in the artificial chloride solution. The chloride penetration resistance was evaluated by penetration depth and chloride diffusion coefficient. As a result, all of the mineral admixtures were effective on the chloride penetration resistance of concrete compared to ordinary portland cement only.

  • PDF

Current Status of the Durability Study of Concrete Made with Various Cements in Korean Marine Environment (한국해양조건에서의 시멘트 종류별 콘크리트 내구 특성)

  • 박춘근;엄태형;정해문;임정렬;지정식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.163-169
    • /
    • 1997
  • The sea water resistance of cement and concrete must be considered when it is used for construction on the seashore of in the ocean. The concrete specimens using seven type of cements such as ordinary Portland cement, moderate heat Portland cement, sulfate resistance Portland cement, type A. B. C Portland blastfurnace slag cement and Portland flyash cement were immersed for 10 years in seawater in Kunsan. This study proved that moderate heat Portland cement, sulfate resistance Portland cement, type A Portland blastfurnace slag cement had higher resistance for seawater.

  • PDF

Surface Scaling Resistance of Latex-Modified Concretes (라텍스개질 콘크리트 종류에 따른 표면 박리 저항 특성)

  • 이훈재;김성환;홍창우;윤경구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.757-762
    • /
    • 2002
  • This study focused on the investigation of durability of latex modified concrete in the points of surface scaling resistance as cement types variated and latex content variated such as 5%, 10%, 15%, and 20%. An increasing the amount of latex produced concrete with increased flexural strength, but with slightly lower compressive strength. The increase in flexural strength might be attributed to the latex films between the hydrated cement and aggregates, and the decrease in compressive strength to the flexibility of the latex component named by Butadiene. The surface scaling resistance test was used to evaluate the durability of latex-modified concretes and rapid setting latex-modified concretes. The surface scaling resistance of LMC was quite good comparing to conventional concrete. Further, surface scaling resistance of RSLMC was improved with increasing the latex content.

  • PDF

A Study on Corrosion Resistance of Reinforced Concrete Structures using Natural Inorganic Minerals (천연 무기 광물계 혼화재료를 혼입한 철근콘크리트 구조물의 부식저항성에 관한 연구)

  • Tae, Sung Ho;Park, Jae Young;Kim, Jae Young;Park, Jae Seung;Kyung, Je Woon;Nam, Ho Yoon
    • KIEAE Journal
    • /
    • v.7 no.4
    • /
    • pp.127-133
    • /
    • 2007
  • As a fundamental study on the corrosion resistance of reinforced concrete structures using Natural Inorganic Minerals exposed to carbonation environment, The test specimens were concrete(W/C=60%) with Natural Inorganic Minerals content of 0%, 10%. Accelerated carbonation and autoclave corrosion accelerated curing were then conducted with them. The corrosion resistance of steel in concrete with Natural Inorganic Minerals content of 0%, 10% was examined by corrosion form, half-cell potential, polarization resistance, corrosion area and weight loss after 24 hours of autoclave corrosion accelerated curing.The results of the study showed that as for steel in concrete with Natural Inorganic Minerals content of 10%, the corrosion resistance was more excellent than steel in concrete with Natural Inorganic Minerals content of 0%.

Freezing-Thawing Resistance of Concrete Using Steel Slag as Coarse Aggregate (제강슬래그를 굵은 골재로 이용한 콘크리트의 동결융해 저항성)

  • Lee, Hyo-Seong;Han, Sang-Ho
    • Journal of Advanced Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.295-301
    • /
    • 2018
  • In this study, freezing-thawing resistance of concrete using steel slag as coarse aggregate(steel slag concrete) from Gwangyang Iron Co. was estimated to offer basic data for utilization of much more steel slag. Freezing-thawing test of concrete using crushed stone as coarse aggregate(crushed stone concrete) whose compressive strength and air contents are as close as possible to those of the steel slag concrete was performed. Because they are main two factors that affect of freezing-thawing resistance. The test was carried out up to 400 cycles according to KS F 2456. The compressive strength and weight of two concretes were measured and compared. As a result, the freezing-thawing resistance of steel slag concrete curing in water was almost the same with that of crushed stone concrete. But the resistance of steel slag concrete curing in air dry condition was weaker than that of crushed stone concrete. Also, the steel slag concrete which has more than 60% of W/C ratio showed much more surface degradation when compared to crushed stone concrete.

Design models for predicting shear resistance of studs in solid concrete slabs based on symbolic regression with genetic programming

  • Degtyarev, Vitaliy V.;Hicks, Stephen J.;Hajjar, Jerome F.
    • Steel and Composite Structures
    • /
    • v.43 no.3
    • /
    • pp.293-309
    • /
    • 2022
  • Accurate design models for predicting the shear resistance of headed studs in solid concrete slabs are essential for obtaining economical and safe steel-concrete composite structures. In this study, symbolic regression with genetic programming (GPSR) was applied to experimental data to formulate new descriptive equations for predicting the shear resistance of studs in solid slabs using both normal and lightweight concrete. The obtained GPSR-based nominal resistance equations demonstrated good agreement with the test results. The equations indicate that the stud shear resistance is insensitive to the secant modulus of elasticity of concrete, which has been included in many international standards following the pioneering work of Ollgaard et al. In contrast, it increases when the stud height-to-diameter ratio increases, which is not reflected by the design models in the current international standards. The nominal resistance equations were subsequently refined for use in design from reliability analyses to ensure that the target reliability index required by the Eurocodes was achieved. Resistance factors for the developed equations were also determined following US design practice. The stud shear resistance predicted by the proposed models was compared with the predictions from 13 existing models. The accuracy of the developed models exceeds the accuracy of the existing equations. The proposed models produce predictions that can be used with confidence in design, while providing significantly higher stud resistances for certain combinations of variables than those computed with the existing equations given by many standards.

Improvement of Strength and Chemical Resistance of Silicate Polymer Concrete

  • Figovsky, Oleg;Beilin, Dmitry
    • International Journal of Concrete Structures and Materials
    • /
    • v.3 no.2
    • /
    • pp.97-101
    • /
    • 2009
  • It has been known that acid-resistant concretes on the liquid glass basis have high porosity (up to 18${\sim}$20%), low strength and insufficient water resistance. Therefore they can not be used as materials for load-bearing structural elements. Significant increasing of silicate matrix strength and density was carried out by incorporation of special liquid organic alkali-soluble silicate additives, which block of superficial pores and reduces concrete shrinkage deformation. It was demonstrated that introduction of tetrafurfuryloxisilane additive sharply increases strength, durability and shock resistance of silicate polymer concrete in aggressive media. This effect is attributable to hardening of contacts between silicate binder gel globes and modification of alkaline component owing to "inoculation" of the furan radical. The optimal concrete composition with the increased strength, chemical resistance in the aggressive environments, density and crack resistance was obtained.

The influence of EAF dust on resistivity of concrete and corrosion of steel bars embedded in concrete

  • Almutlaq, Fahad M.
    • Advances in concrete construction
    • /
    • v.2 no.3
    • /
    • pp.163-176
    • /
    • 2014
  • Essentially, when electrical current flows easily in concrete that has large pores filled with highly connective pore water, this is an indication of a low resistivity concrete. In concrete, the flow of current between anodic and cathodic sites on a steel reinforcing bar surface is regulated by the concrete electrical resistance. Therefore, deterioration of any existing reinforced concrete structure due to corrosion of reinforcement steel bar is governed, to some extent, by resistivity of concrete. Resistivity of concrete can be improved by using SCMs and thus increases the concrete electrical resistance and the ability of concrete to resist chloride ingress and/or oxygen penetration resulting in prolonging the onset of corrosion. After depassivation it may slow down the corrosion rate of the steel bar. This indicates the need for further study of the effect of electric arc furnace dust (EAFD) addition on the concrete resistivity. In this study, concrete specimens rather than mortars were cast with different additions of EAFD to verify the electrochemical results obtained and to try to understand the role of EAFD addition in influencing the corrosion behaviour of reinforcing steel bar embedded in concrete and its relation to the resistivity of concrete. The results of these investigations indicated that the corrosion resistance of steel bars embedded in concrete containing EAFD was improved, which may link to the high resistivity found in EAFD-concrete. In this paper, potential measurements, corrosion rates, gravimetric corrosion weight results and resistivity measurements will be presented and their relationships will also be discussed in details.

An Experimental Study on the Frost Resistance of High-Strength Concrete using Blast-Furnace Slag (고로슬래그를 이용한 고강도콘크리트의 내동해성에 관한 실험적 연구)

  • 박선규;유재강;강석표;권영진;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.671-674
    • /
    • 1999
  • With increasing content of granulated blase furnace slag in cement, the content of capillary pores in the mortar decreases and later age strength of the concrete. Therefore, this provides greater reserves study is carried out to estimate frost resistance of high-strength concrete specimens with water cement ratios using blast-furnace slag. 1. Blast furnace concrete is comparatively more good frost resistance than normal concrete. 2. As the blast furnace slag increases, the quantity of pores with a radius of more than 30nanometer decreses.

  • PDF

Experimental Study on Fire Resistance Performance of CFT (Concrete filled Tube) Column according to Cross Section of Steel, Concrete Compressive Strengths and Load Ratios (강관의 크기, 축력비 및 콘크리트 압축강도 변화에 따른 CFT 기둥부재의 내화성능에 관한 실험적 연구)

  • Cho, Kyung-Suk;Kim, Heung-Youl;Kim, Hyung-Jun;Min, Byung-Yeol;Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.104-111
    • /
    • 2010
  • The strength of steel in a concrete filled steel tube (CFT) is reduced in a fire, but the concrete filled structurally ensures the fire resistance due to its high thermal capacity. This research analyzed the fire resistance performance due to the variances of concrete strength filled inside of steel tube and the load ratios, which can influence on the fire resistance of CFT. As $280{\times}280{\times}6$ CFT columns with the concrete strengths of 24 MPa and 40 MPa and the axial load ratios of 0.9, 0.6, and 0.2 in accordance with KS F 2257-1 and 7 were heated with loading to examine the fire resistance performance, the fire resistance used to 24 MPa concrete showed 27, 113, and 180 minutes according to the axial load ratios, 0.9, 0.6, and 0.2 respectively. In case of 40 MPa concrete, the fire resistance were turned out to be 19 and 28 minutes for the axial load ratios, 0.9 and 0.6 respectively. The results of fire resistance with 40 MPa concrete showed the much lower fire resistance performance than those of 24 MPa concrete. In case of 40 MPa, the fire resistance performance was not increased significantly according to the axial load ratio than that of 24 MPa. The main reason why the higher concrete strength showed lower fire resistance than that of lower guessed the internal stress had the concrete strength weak.