• Title/Summary/Keyword: concrete property

Search Result 957, Processing Time 0.024 seconds

Self-diagnosis property of strengthened concrete by rib of hybrid FRP and carbon fiber sheet (하이브리드FRP 탄소계 리브 및 탄소섬유시트 보강 콘크리트의 자가진단 기능 검토)

  • Park, Seok-Kyun;Kim, Dae-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.358-361
    • /
    • 2006
  • For giving self-diagnosing capability, a method based on monitoring the changes in the electrical resistance of carbon materials in strengthened concrete has been tested. Then after examining change in the value of electrical resistance of carbon materials used as a rib of CFGFRP or a sheet of carbon fiber before and after the occurrence of cracks and fracture in hybrid FRP or carbon fiber sheet strengthened concrete at each flexural weight-stage, the correlations of each factors were analyzed.

  • PDF

An Experimental Study on the Characterisitics of High Strength Concrete(over the 80Mpa) for adapt to CFT (CFT구조 적용을 위한 고강도 콘크리트(80이상)의 기초물성 연구)

  • 이장환;강용학;공민호;정근호;김진호;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.561-564
    • /
    • 2003
  • One of the most important reasons that CFT is used in many conditions is by using that we can achieve the effect, which reduce the section of the member. This research purpose to find the most ideal composition, which is achieved by the investigation in the concrete's property of matter like ability of Slump, Slump Flow, Air content, Bleeding, and Settlement when the high strength of concrete which is over 80㎫ is used in the CFT column.

  • PDF

An Experimental Study on the Strength and Deformation of Reinforced Concrete Shear Wall (철근 콘크리트 내진벽의 강도와 변형에 대한 실험적 연구)

  • 전영주;이동근;이수곤
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.10a
    • /
    • pp.243-249
    • /
    • 1993
  • The porpose of this study is to suggest an experimental for shear wall of reinforced concrete wall structure. A series of experimental be performed for earned to strength and deformation property of reinforced concrete shear wall. These specimens are three R/C walls among five models which had boundary. As a result, it was found that cyclic experiment is very proper and cyclic time must be increased 3 or 5 times. Monotonic test results was indicated over 15% than other experiment for yielding strength and ultimate strength.

  • PDF

A Study on Durable Concrete for Marine Environment with Flowing Property (고유동의 내해수성 콘크리트에 관한 연구)

  • 최광일;박춘근;하재담;정해문;강민호;김종우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.292-297
    • /
    • 1997
  • Concrete structure which placed aggressive marine environment must have proper durablity. Portland cement type V has been used for this purpose. However, besides this, flowability was required in specific part. (highly congested reinforced part, hard to vibrating part, etc.) For this purpose concrete mixtures were made with potland type V and specific amount of pozzolan material and tested structural properties including flowabilily and durability.

  • PDF

An Evaluation on Toughness of Ductile Fiber Reinforced Cementitious Composite according to Thickness and restrained method (시험체 형상 및 시험방법에 따른 고인성 콘크리트의 인장특성 평가에 관한 연구)

  • Park, Yun-Mi;Kim, Young-Duck;Kim, Young-Bong;Jeong, Jae-Hong;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.469-472
    • /
    • 2008
  • As a general rule, concrete has higher compression strength than bending and toughness. but Ductile fiber reinforced cementitious composite has high toughness property owing to adding a large volume fiber. Therefore uniaxial tensile strength test is imperative to evaluate high toughness property of ductile fiber reinforced cementitious composite in comparison with general concrete test. but in testing compression strength, Result is different by factor of thickness, shape and edge condition. Uniaxial tensile strength test is affected by fiber's length and section area because of cementitious composite property and factor of fiber arrangement. This study evaluates toughness property of ductile fiber reinforced cementitious composite according to thickness and edge condition. The more thickness is thin, the more high performance by fiber arrangement

  • PDF

A Study on Field Application of 150MPa Ultra Strength Surface-Exposed Concrete (150MPa급 초고강도 노출콘크리트의 현장적용에 관한 연구)

  • Kong, Tae-Woong;Lee, Soo-Hyung;Jang, Jae-Hwan;Lee, Han-Baek
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.989-992
    • /
    • 2008
  • In this paper, we are presenting a case that integrates ultra high strength concrete(150MPa) with surface-exposed concrete. Ahead of the field application, we carried out laboratory experiment and B/P Test for a basic property of concrete(slump flow, air content, 50cm flow time, elapse time change and compression strength) and productivity. The next, we conducted Mock-up Test using simulation specimen to evaluate infilling, surface-finishing and hydration heat of concrete. We had satisfactory results for a basic property and hydration heat of concrete. However at the time of field application, it was occurred rupture of formwork because of high lateral pressure of concrete, and then formwork was reinforced and case-in-place time was adjusted. And regardless of low and high frequency vibration, it occurred to surface-pockmark. In case that applies ultra high strength concrete to surface-exposed concrete, we estimate that it is important of systematic management and improvement of construction.

  • PDF

The Effect on Latent Hydraulic Property of the Blast-furnace Slag by Alkali Activator (알칼리 자극제가 고로슬래그의 잠재수경성에 미치는 영향)

  • Lee, Seung-Han;Park, Jeong-Seob;Jung, Yong-Wook
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.929-934
    • /
    • 2001
  • This study aimed to examine the cause of latent hydraulic property manifestation of ground granulated blast-furnace slag(GGBFS) using different alkali activators in pH, type and quantity. According to the experimental result, the higher pH value accelerated lastly latent hydraulic property and the early stage strength of GCBFS was ranked as activators with the higher pH, in an order of NaOH, $Ca(OH)_{2}$ and $Na_{2}$$Co_{3}$. Also, NaOH had accelerated latent hydraulic property of GGBFS, which had 40~50% of the 3 and 7 days compressive strength of base mortar in case of using 10% of powder-weight. In the case of 30% of GGBFS substitution with annexing 2.5% $Ca(OH)_{2}$, the compressive strength on the 3 and 7 days of the early-age, was increased to 5~10% than that of the same admixture with no activator. With annexing 5.0% $Ca(OH)_{2}$, the strength was increased to 10~20%. Although activator NaOH was effective on the manifestation of latent hydraulic property, it caused cement mortar compressive strength decrease by enlarging pore diameter.

  • PDF

Development and Application of Low Permeable Concrete for Underground Structures (지하구조물을 위한 수밀콘크리트의 개발 및 실용화)

  • Paik, S.H.;Park, S.S.;Park, J.Y.;Paik, W.J.;Um, T.S.;Choi, L.
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.259-262
    • /
    • 1999
  • In underground reinforced concrete structures, such as drainage structure, water and chloride ion penetrated into concrete through the cracks of concrete and its permeable property, cause the corrosion of reinforcing steel bar, which accelerates the expansive cracks and deterioration of concrete. It is necessary to control those deterioration of underground structure by improving its permeability and durability through the reasonable solutions in design, construction and materials. In the present study, fly ash concrete, which has good material properties in long-term period, was compared and studied with plain concrete using ordinary portland cement in terms of fundamental mechanical properties, permeability, drying shrinkage and durability. Also, the mix design and field test of low permeable concrete using fly ash were performed. From this study, fly ash concrete can control the penetration of water and chloride ion effectively by forming dense micro-structure of concrete. Therefore, fly ash concrete may increase the long-term function, performance and serviceability of underground structures.

  • PDF

An Experimental Study on Physical Properties of Concrete using Admixtures for High Strength Concrete (고강도 콘크리트용 혼화재를 사용한 콘크리트의 물성에 관한 실험적 연구)

  • 이승한;배재길;이종석
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.04a
    • /
    • pp.203-208
    • /
    • 1994
  • These tests were conducted to get a device high strength concrete products in factory using admixtures for high strength concrete. The superplasticzer was used to compensate low slump of base concrete keeping its slump up about $6\pm1cm$. To examine the property for strength revelation of concrete using admixtures for high strength concrete, steam and standard curing were compared each other. Test results show that admixtures for high strength concrete is effective in steam curing and compressive strength 500kgf/$\textrm{cm}^2$ is obtained at one day, 650kgf/$\textrm{cm}^2$ at 28days as added to concrete at the ratio of 10-15%, and 740kgf/$\textrm{cm}^2$ at the ratio of 30%. Therefore admixtures for high strength concrete is effective in steam curing and make it possible to get high strength concrete using only steam curing not using autoclave curing.

  • PDF

Experimental Study on Thermal Conductivity of Concrete (콘크리트의 열전도율에 관한 실험적 연구)

  • 김국한;전상은;방기성;김진근
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.4
    • /
    • pp.305-313
    • /
    • 2001
  • Conductivity is an important thermal property which governs heat transfer in a solid medium. Generally, the determination of conductivity in concrete is very difficult, because concrete is a heterogeneous material composed of cement, water, aggregate, et cetera and time dependent material of which properties change with curing age. In this study, influencing factors on thermal conductivity of concrete are quantitatively investigated by QTM-D3, a conductivity tester developed in Japan. Then, a prediction equation of thermal conductivity of concrete is suggested from the regression analysis of test results. To consider the factors influencing thermal conductivity of concrete, mortar, and cement paste, seven testing variables (age, amount of cement, types of admixtures, amount of coarse aggregate, fine aggregate ratio, temperature, and humidity condition) of the specimens are used. According to the experimental results, the amount of coarse aggregate and humidity condition of specimen are the main factors affecting the conductivity of concrete. Meanwhile, the conductivity of mortar and cement paste is strongly affected by the amount of cement and types of admixtures. However, the curing age has minor effect on the conductivity variation. Finally, the prediction formula of concrete conductivity as a function of aggregate amount, fine aggregate ratio, specimen temperature, and humidity condition is developed.