A Study on Field Application of 150MPa Ultra Strength Surface-Exposed Concrete

150MPa급 초고강도 노출콘크리트의 현장적용에 관한 연구

  • Published : 2008.04.24

Abstract

In this paper, we are presenting a case that integrates ultra high strength concrete(150MPa) with surface-exposed concrete. Ahead of the field application, we carried out laboratory experiment and B/P Test for a basic property of concrete(slump flow, air content, 50cm flow time, elapse time change and compression strength) and productivity. The next, we conducted Mock-up Test using simulation specimen to evaluate infilling, surface-finishing and hydration heat of concrete. We had satisfactory results for a basic property and hydration heat of concrete. However at the time of field application, it was occurred rupture of formwork because of high lateral pressure of concrete, and then formwork was reinforced and case-in-place time was adjusted. And regardless of low and high frequency vibration, it occurred to surface-pockmark. In case that applies ultra high strength concrete to surface-exposed concrete, we estimate that it is important of systematic management and improvement of construction.

본 연구에서는 선일공업(주)의 축적된 기술력을 바탕으로 초고강도(150MPa급) 콘크리트를 당사 기술 연구소 신축시 노출콘크리트에 적용함으로써, 이에 대한 사례를 소개하고자 한다. 현장적용에 앞서 실내실험 및 레미콘 배치플랜트 실험(이하 B/P Test)을 통해 콘크리트의 기초물성(슬럼프플로우, 공기량, 50cm도달시간, 경시변화, 압축강도) 및 생산성을 평가하였으며, 다음으로 실구조물과 동일한 벽체두께 거푸집종류 노출콘크리트용 콘 등을 고려하여 제작한 모의부재를 대상으로 Mock-up Test를 실시하여 충진성, 표면마감성(육안관찰) 및 수화열을 평가하였다. 그 결과 슬럼프플로우, 공기량, 50cm도달시간, 경시변화 및 압축강도는 요구조건에 만족한 결과를 보였으며, 수화열 계측결과는 온도균열지수 0.78로 유해한 균열발생을 제한할 지수를 나타냈다. 현장타설시 초고강도 콘크리트의 높은 단위용적중량으로 인해 거푸집 터짐현상이 발생하였기 때문에, 재타설시에는 재발방지를 위해 거푸집을 보강하고 타설시간을 조정하였다. 또한 노출표면의 극대화를 위해 저주파(1차) 및 고주파(2차)로 2회에 걸쳐 진동다짐을 실시하였지만 표면곰보가 발생하였다. 따라서 향후 초고강도 콘크리트를 노출콘크리트에 적용할 경우, 다양한 변수조건에 대한 체계적인 시공관리계획 및 시공방법개선이 중요할 것으로 판단된다.

Keywords