• 제목/요약/키워드: concrete layers

검색결과 333건 처리시간 0.026초

Influence of temperature on the beams behavior strengthened by bonded composite plates

  • Bouazza, Mokhtar;Antar, Kamel;Amara, Khaled;Benyoucef, Samir;Bedia, El Abbes Adda
    • Geomechanics and Engineering
    • /
    • 제18권5호
    • /
    • pp.555-566
    • /
    • 2019
  • The purpose of this paper is to investigate the thermal effects on the behaviour reinforced-concrete beams strengthened by bonded angle-ply laminated composites laminates plate $[{\pm}{\theta}n/90m]_S$. Effects of number of $90^{\circ}$ layers and number of ${\pm}{\theta}$ layers on the distributions of interfacial stress in concrete beams reinforced with composite plates have also been studied. The present results represent a simple theoretical model to estimate shear and normal stresses. The effects the temperature, mechanical properties of the fibre orientation angle of the outer layers, the number of cross-ply layers, plate length of the strengthened beam region and adhesive layer thickness on the interfacial shear and normal stresses are investigated and discussed.

반복하중을 받는 철근콘크리트 보의 소성힌지 이동에 관한 실험적 연구 (An Experimental Study on the Relocating Plastic Hinging Zones of Reinforced Concrete Beams Subjected to Cyclic Loads)

  • 김윤일;최창식;천영수;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1989년도 가을 학술발표회 논문집
    • /
    • pp.77-82
    • /
    • 1989
  • In this paper an experimental approach of the relocation plastic hinging zones of nine reinforced concrete exterior beam-column subassemblages under cyclic loads was tried. The main parameters of the testing program were location of the plastic hinge, difference of the special reinforcement, inclined or intermediate layers of longitudinal reinforcement, applied maximum shear stress. The conclusions presented herein are based on the limited texts conducted. Inclined or intermediate layers of longitudinal reinforcement and extra top and bottom steel in the beam over a specific legnth can be used to move the beam plastic hinging zone away from the column face. But, for the use of intermediate layers of longitudinal reinforcement, sheat reinforcement detail need further investigation.

  • PDF

Increasing the flexural capacity of RC beams using partially HPFRCC layers

  • Hemmati, Ali;Kheyroddin, Ali;Sharbatdar, Mohammad K.
    • Computers and Concrete
    • /
    • 제16권4호
    • /
    • pp.545-568
    • /
    • 2015
  • High Performance Fiber Reinforced Cementitious Composites which are called HPFRCC, include cement matrices with strain hardening response under tension loading. In these composites, the cement mortar with fine aggregates, is reinforced by continuous or random distributed fibers and could be used for various applications including structural fuses and retrofitting of reinforced concrete members etc. In this paper, mechanical properties of HPFRCC materials are reviewed briefly. Moreover, a reinforced concrete beam (experimentally tested by Maalej et al.) is chosen and in different specimens, lower or upper or both parts of that beam are replaced with HPFRCC layers. After modeling of specimens in ABAQUS and calibration of those, mechanical properties of these specimens are investigated with different thicknesses, tensile strengths, tensile strains and compressive bars. Analytical results which are obtained by nonlinear finite analyses show that using HPFRCC layers with different parameters, increase loading capacity and ultimate displacement of these beams compare to RC specimens.

Efficiency of insulation layers in fire protection of FRP-confined RC columns-numerical study

  • El-Mahdya, Osama O.;Hamdy, Gehan A.;Hisham, Mohammed
    • Structural Engineering and Mechanics
    • /
    • 제77권5호
    • /
    • pp.673-689
    • /
    • 2021
  • This paper addresses the efficiency of thermal insulation layers applied to protect structural elements strengthened by fiber-reinforced polymers (FRP) in the case of fire event. The paper presents numerical modeling and nonlinear analysis of reinforced concrete (RC) columns externally strengthened by FRP and protected by thermal insulation layers when subjected to elevated temperature specified by standard fire tests, in order to predict their residual capacity and fire endurance. The adopted numerical approach uses commercial software includes heat transfer, variation of thermal and mechanical properties of concrete, steel reinforcement, FRP and insulation material with elevated temperature. The numerical results show good agreement with published results of full-scale fire tests. A parametric study was conducted to investigate the influence of several variables on the structural response and residual capacity of insulated FRP-confined columns loaded by service loads when exposed to fire. The residual capacity of FRP-confined RC column was affected by concrete grade and insulation material and was shown to improve substantially by increasing the concrete cover and insulation layer thickness. By increasing the VG insulation layer thickness 15, 32, 44, 57 mm, the loss in column capacity after 5 hours of fire was 30%, 13%, 7% and 5%, respectively. The obtained results demonstrate the validity of the presented approach for estimation of fire endurance and residual strength, as an alternative for fire testing, and for design of fire protection layers for FRP-confined RC columns.

DEM analysis of the anisotropy effects on the failure mechanism of the layered concretes' specimens with internal notches

  • Jinwei Fu;Vahab Sarfarazi;Hadi Haeri;Mohammad Fatehi Marji
    • Computers and Concrete
    • /
    • 제33권6호
    • /
    • pp.659-670
    • /
    • 2024
  • The mechanical behaviour of layered concrete samples containing an internal crack was numerically studied by modelling the geo-mechanical specimens in the particle flow code in two dimensions (PFC2D). The numerical modelling software was calibrated with the experimental results of the Brazilian tensile strengths gained from the laboratory disc-type specimens. Then, the samples with the bedding layers and internal notch were numerically simulated with PFC2D under uniaxial compressive loading. In each specimen, the layers' thickness was 10 mm but the layer's inclination angle was changed to 0°, 30°, 60°, 90°, 120° and 150°. Of course, the layers'interfaces are considered to have very low strengths. The internal notch was kept at 3 cm in length however, its inclination angle was changed to 0°, 40°, 60° and 90°. Therefore, a total, of 24 numerical models were made to study the failure mechanism of the layered concrete samples. Considering these results, it has been concluded that the inclination angles of both internal crack and bedding layers affect the failure mechanism and uniaxial compressive strength of the concrete.

전자파 레이더 모의해석에 의한 다층 경계 콘크리트 철근 및 내부 공동형상 검출 특성 (Detecting Reinforcing Bars under Multi Boundary Layers and Void Shapes in Concrete Using Simulation Analysis Model of Electromagnetic Wave Radar)

  • 박석균
    • 대한토목학회논문집
    • /
    • 제26권4A호
    • /
    • pp.809-816
    • /
    • 2006
  • 다층경계를 갖는 콘크리트 내의 철근 위치와 공동(공극) 형상을 효과적으로 검출하기 위해, 본 연구에서는 다층경계를 갖는 철근 콘크리트의 레이더 응답 및 무근 콘크리트 내 공동의 형상추정이 가능한 전자파 레이더의 해석 알고리즘을 개발하는데 목표를 두고 있다. 이들 조건에서의 철근 및 공동형상을 검출 또는 추정하기 위해 레이더 모의해석 모델은 다양한 경계조건과 공동형상을 갖는 철근 또는 무근 콘크리트에 대해 적용되었다. 그리고 레이더 모의해석 결과에 대한 출력신호(화상)는 컨볼루션법에 의해 계산하여 나타내었다. 그 결과, 본 모의해석 기법은 철근콘크리트의 다층경계와 콘크리트의 공동형상에 대한 레이더 응답해석에 활용이 가능할 것으로 판단된다.

Development of a computer aided program for slipforming operations incorporating maturity approach

  • Hossain, K.M.A.;Anagnostopoulos, C.;Lachemi, M.
    • Computers and Concrete
    • /
    • 제3권2_3호
    • /
    • pp.177-195
    • /
    • 2006
  • Slipforming is a construction method in which the forms move continuously during the placement of concrete. This paper presents the development of a computer aided program designated as "CADSLIPFORM" for slipforming operations. The program incorporates maturity methods for the prediction of initial setting times of slipform concrete layers using laboratory data (time-temperature histories and setting times of concrete mixtures at different temperatures) and generates slipform mock-up times. The performance of CADSLIPFORM is validated by comparing simulated mock-up times with those estimated in the field through conventional hard front by rod (R) method. Moreover, the program versatility is demonstrated by illustrating mock-up simulations for different cases with variable slipform parameters such as: number and thickness of concrete layers, concrete temperature (simulating variable setting times) and slipform speed. The program also incorporates the choice of Freiesleben Hansen & Pederson (FHP) and Carino & Tank (CT) maturity functions. CADSLIPFORM can assist user to develop reliable schedule of slipforming operation suitable for a specific project by optimizing various slipform parameters.

Experiment and simulation analysis on full scale double-layer concrete shell

  • Thanh Quang Khai Lam;Thi My Dung Do
    • Computers and Concrete
    • /
    • 제31권1호
    • /
    • pp.9-21
    • /
    • 2023
  • The published studies usually used analytical method, numerical methods or experimental method to determine the stress-strain state and displacement of the single-layer or multi-layer curved shell types, but with a small scale model. However, a full scale multi-layer doubly curved concrete shell roof model should be researched. This paper presents the results of the experiment and simulation analysis involving stress-strain state, sliding between layers, the formation and development of the full scale double-layer doubly curved concrete shell roof when this shell begins to crack. The results of the this study have constructed the load-sliding strain relationship; strain diagram; stress diagram in the shell layers; the Nx, Ny membrane force diagram and deflection of shell. Thisresults by experimental method on a full scale model of concrete have clarified the working of multi-layer doubly curved concrete shell roof. The experimental and simulation results are compared with each other and compared with the Sap2000 software.

Analysis of the effect of aged concrete layer on RC beams, and a strengthening method employing carbon-fiber-reinforced polymer (CFRP) sheets.

  • Liana Satlykova;Young Sook Roh
    • Architectural research
    • /
    • 제26권2호
    • /
    • pp.31-39
    • /
    • 2024
  • The numerical study focuses on the analysis of the structural behavior of concrete beams containing outdated concrete and offers an innovative method of strengthening them using carbon-fiber-reinforced polymer sheets (CFRP). The focus is on modeling and analyzing the performance of aged concrete beams strengthened by CFRP in the flexural direction. This study presents an ultimate load model for CFRP-strengthened RC beams featuring outdated concrete layers. Validation through four-point bending tests and finite element modeling demonstrated the efficacy of the model. Findings indicate that CFRP sheets significantly enhance beam strength, particularly in structures with outdated concrete layers, resulting in increased ultimate load capacity. Moreover, an inverse relationship between ultimate load and concrete layer height was observed, with the CFS-21-15-30 sample exhibiting the most substantial reduction. Validation of the model was achieved using finite element analysis con-ducted in Abaqus software.

Experimental study on reinforced high-strength concrete short columns confined with AFRP sheets

  • Wu, Han-Liang;Wang, Yuan-Feng
    • Steel and Composite Structures
    • /
    • 제10권6호
    • /
    • pp.501-516
    • /
    • 2010
  • This paper is aiming to study the performances of reinforced high-strength concrete (HSC) short columns confined with aramid fibre-reinforced polymer (AFRP) sheets. An experimental program, which involved 45 confined columns and nine unconfined columns, was carried out in this study. All the columns were circular in cross section and tested under axial compressive load. The considered parameters included the concrete strength, amount of AFRP layers, and ratio of hoop reinforcements. Based on the experimental results, a prediction model for the axial stress-strain curves of the confined columns was proposed. It was observed from the experiment that there was a great increment in the compressive strength of the columns when the amount of AFRP layers increases, similar as the ultimate strain. However, these increments were reduced as the concrete strength increasing. Comparisons with other existing prediction models present that the proposed model can provide more accurate predictions.