• Title/Summary/Keyword: concrete floor

Search Result 588, Processing Time 0.025 seconds

Direct shear behavior of concrete filled hollow steel tube shear connector for slim-floor steel beams

  • Hosseinpour, Emad;Baharom, Shahrizan;Badaruzzaman, Wan Hamidon W.;Shariati, Mahdi;Jalali, Abdolrahim
    • Steel and Composite Structures
    • /
    • v.26 no.4
    • /
    • pp.485-499
    • /
    • 2018
  • In this paper, a hollow steel tube (HST) shear connector is proposed for use in a slim-floor system. The HST welded to a perforated steel beam web and embedded in concrete slab. A total of 10 push-out tests were conducted under static loading to investigate the mechanical behavior of the proposed HST connector. The variables were the shapes (circular, square and rectangular) and sizes of hollow steel tubes, and the compressive strength of the concrete. The failure mode was recorded as: concrete slab compressive failure under the steel tube and concrete tensile splitting failure, where no failure occurred in the HST. Test results show that the square shape HST in filled via concrete strength 40 MPa carried the highest shear load value, showing three times more than the reference specimens. It also recorded less slip behavior, and less compressive failure mode in concrete underneath the square hollow connector in comparison with the circular and rectangular HST connectors in both concrete strengths. The rectangular HST shows a 20% higher shear resistance with a longer width in the load direction in comparison with that in the smaller dimension. The energy absorption capacity values showed 23% and 18% improvements with the square HST rather than a headed shear stud when embedded in concrete strengths of 25 MPa and 40 MPa, respectively. Moreover, an analytical method was proposed and predicts the shear resistance of the HST shear connectors with a standard deviation of 0.14 considering the shape and size of the connectors.

Study on the Utilization of Sawdust Bedding Barn for Dairy Cows II. Comparision of utilization efficiency of the different depth of sawdust bedding for dairy cows (착유우의 톱밥발효우사 이용 연구 제2보 :착유우 톱밥발효우사의 톱밥상 처리방법에 따른 이용효과 비교)

  • 권두중;권응기;정석근;한정대;정석찬;강승원;강상열;정형섭;장학주
    • Journal of Animal Environmental Science
    • /
    • v.1 no.2
    • /
    • pp.117-124
    • /
    • 1995
  • This study was carried out to investigate the effect of depth of sawdust bedding and ground material in dairy cattle barn. Treatment included the concrete floor with a 10cm or 30cm sawdust and the earth floor with a 30cm sawdust. Eighteen cows were assigned to 3 pens with 16.5㎥/head bedding area. The results obtained were as follows : 1. The temperature of sawdust bed was highest in the earth floor with 30cm sawdust, and the moisture content of sawdust bed was highest in the concrete floor with 10cm sawdust bed. 2. Cows defecate feces 9.2, 8.7 and 9.3 times a day in 10cm sawdust on concrete floor(10S+C), 30cm sawdust on concrete floor(30S+C) and 30cm sawdust on non concrete floor(30S+ NC) respectively. In average, they excreta 9.1 times/day(85.8%) in the sawdust beds and 1.5 times/day(14.2%) in the feeding alley. 3. The ratio of daily water amount deposited vapor to total water amount deposited in sawdust beds was 74.0%, 61.5% and 47.1% in 10S+C, 30S+C and 30S+NC respectively. 4. N.P.K contents in the sawdust beds were higher for 10S+C compared with other treatments. 5. When 30cm of sawdust was applied on the earth ground NO$_3$-N contents in the sawdust bed was 37.7, 14.1 and 15.0ppm in depth of 30, 60 and 90cm under the ground, respectively, indicating some possibility of water pollution.

  • PDF

The Application of 122kg/$\textrm{cm}^2$ Ultra High Strength Concrete on Tall Building (1200kg/$\textrm{cm}^2$ 초고강도 콘크리트의 고층 주상복합구조물에의 시공 및 특성화 연구)

  • 신성우;안종문;유석형;윤영수;이승훈;백승준
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.10a
    • /
    • pp.262-266
    • /
    • 1995
  • This paper present the application and construction characteristics of Ultra-High Strength Concrete on Samsung Sin Dae-Bang Housing-Commercial Combined building with 28 story including 8 story basement in seoul. 1200kg/ $\textrm{cm}^2$compressive strength has been placed for paraphet at lst floor for experimental purposes. 420kg/$\textrm{cm}^2$ design strength concrete was used for other basement and frame up to 10th floor which is used for commercial purposes.

  • PDF

A Study on the Characteristics of Sound Insulation at the Circular Voided Concrete Floor in the Multi-Housing (공동주택에서 중공 슬래브 바닥의 차음 특성에 관한 연구)

  • 손철수
    • Journal of the Korean housing association
    • /
    • v.11 no.1
    • /
    • pp.171-181
    • /
    • 2000
  • The purpose of the resent research is to investigate the characteristics of sound insulation at the circular voided concrete slab in the multi-housing. In order to do this research, the method for field measurement of floor impact sound level was used following the Korea Standard F2810-1996. For the multi-housing, three kinds of circular voided concrete slabs are used to measure the characteristics of sound insulation.The results are as follows; 1.The main factor affecting the characteristics of sound insulation at the circular voided concrete slab in the multi-housing is sound-absorbing materials in the circular tube. 2. The main factor to effect the difference of sound pressure level is circular tube in the concrete slab. 3. The forms of circular tubes effect the characteristics of sound insulation at the circular tube. 4. Sound Pressure Level resulting from the piping direction of circular tubes in little different to octave band level.More study will be needed about the depth and distance of sound insulation materials, and the components of sound insulation materials for the multi-housing.

  • PDF

Engineering characteristics of the Fiber Reinforced Floor Finishing Concrete According to the changes of Nylon Fiber Length (나일론 섬유의 길이변화에 따른 섬유보강 바닥마감용 콘크리트의 공학적 특성)

  • Jeon, Kyu-Nam;Baek, Dae-Hyun;Jung, Woo-Tai;Park, Jong-Sup;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.153-156
    • /
    • 2009
  • This study investigated the fundamental properties corresponding to various length changes on NY fiber reinforced concrete. For results of fresh concrete, the slump and air content were declined, but the unit volume weight and vebe time were increased. For the hardened concrete properties, the compressive strength showed increasing tendency according to the NY fiber length. The dry and autogenous shrinkage also decreased compared with Plain. Generally, the caes that 19 mm NY fiber was used was better than any other cases.

  • PDF

Effect of Constructional Deflection of Composite Beam on Concrete Ponding in Metal Deck Slab (합성보의 시공중 처짐이 합성데크슬래브의 콘크리트 고임에 미치는 영향)

  • Kim, Young-Chan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.4
    • /
    • pp.99-106
    • /
    • 2002
  • In the composite deck system, beams and deck plates deflect during construction. This lens-shaped deflection may cause problems in the serviceability of a building. Therefore, it should be compensated to be level. Several methods for leveling of floor slab are available, such as (1) increasing stiffness of structural members, (2) propping floor system, (3) cambering beams, (4) pouring additional concrete. In this study, additional weight and volume of concrete for level compensation are examined for various size of floors.

Effect of Floor Heating System on Housing Environment and Performance in Broiler Production (바닥난방이 육계의 사육환경 및 생산성에 미치는 영향)

  • 최희철;이덕수;서옥석;한정대;강희설;권두중;곽정훈;강보석;장병귀
    • Korean Journal of Poultry Science
    • /
    • v.26 no.3
    • /
    • pp.189-193
    • /
    • 1999
  • This experiment was conducted to investigate the effect of floor heating system on housing environment and performance in broiler production. PVC heating pipes(in 25cm spacing) were covered with concrete under the litter. Floor heating system was compared with conventional direct heating system. Each treatment had two replicates of 110 birds each. Litter moisture content was significantly reduced in floor heating system than conventional direct heating system(P〈0.05). Dust concentration was higher in floor heating system because of low litter moisture content. CO$_2$concentration was 2,900ppm and 1,500ppm on the direct heating system and floor heating system, respectively at the age of 1 week. Body weight was significantly higher in floor heating system at 7 weeks of age(P〈0.05). The results of the trial show that floor heating was useful heating system for broiler production.

  • PDF

Structural Evaluation and Remediation of Floor Slab Deflection

  • Park, Ki-Dong;Kim, Dae-Young;Joung, Dae-Ki
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.61-65
    • /
    • 2008
  • A 4-story reinforced concrete structure built above an underground parking garage shows some slab deflections, and the deflections of the concrete floor slabs are proposed to be alleviated by the application of light-weight topping material in conjunction with localized strengthening of the slabs. The application of light-weight concrete topping on the existing slab has been simulated and its performance to anticipated loads has been analyzed. The application of light-weight topping material imposes additional weight on the exiting floor slabs. This added weight on the existing slabs causes over-stressing of the slabs. This over-stressing can be alleviated by enhancing the load carrying capacity of the existing slabs. Additional load carrying capacity in the existing slabs can be developed by localized strengthening of the slabs utilizing techniques such as the application of fiber-reinforced composites on the bottom surface of the slabs, and application of fiber-reinforced composites adequately complements the capacity of the existing slabs to bear the additional load imposed by light-weight leveling material. Additional moments in the beam and columns induced by the application of the light-weight topping material were tabulated and compared with capacity. The moment D/C ratios of the beam and columns are well the range of acceptable limits, and the beam and columns are not overstressed by the application of the surcharge.

  • PDF

Development of Polymer Mortar Floor Members for Swine Housing Reinforced by FRP (FRP 보강 폴리머 모르터를 이용한 돈사 바닥재 개발)

  • 유능환
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.4
    • /
    • pp.124-129
    • /
    • 2000
  • The objective of this study is to develop a polymer mortar floor members for wine housing with high strength and durability using unsaturated polyester resin to complement defects of conventional cement concrete. Physical and mechanical properties of the polymer mortar floor members for swine housing are also investigated. Specimens with different panel thickness and FRP reinforcement are prepared, tested, and analyzed with respect to structural behaviors. Cracking moment is mostly affected by the thickness and reinforced FRP. Data of the study can be applied to the designing and planning of floor members for swine housing.

  • PDF