Direct shear behavior of concrete filled hollow steel tube shear connector for slim-floor steel beams |
Hosseinpour, Emad
(Department of Civil and Structural Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia)
Baharom, Shahrizan (Department of Civil and Structural Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia) Badaruzzaman, Wan Hamidon W. (Department of Civil and Structural Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia) Shariati, Mahdi (Faculty of Civil Engineering, University of Tabriz) Jalali, Abdolrahim (Faculty of Civil Engineering, University of Tabriz) |
1 | Uenaka, K. and Higashiyama, H. (2015), "Mechanical characteristics of hollow shear connectors under direct shear force", Steel Compos. Struct., Int. J., 18(2), 467-480. DOI |
2 | Vianna, J.D.C., Costa-Neves, L.F., Vellasco, P.C.G.d.S. and Andrade, S.A.L.d. (2008), "Structural behavior of T-Perfobond shear connectors in composite girders: An experimental approach", Eng. Struct., 30(9), 2381-2391. DOI |
3 | ViscoCrete-2055, S. (2011), https://usa.sika.com/en/solutions_products.html |
4 | Wang, J., Afshan, S., Gkantou, M., Theofanous, M., Baniotopoulos, C. and Gardner, L. (2016), "Flexural behavior of hot-finished high strength steel square and rectangular hollow sections", J. Const. Steel Res., 1(21), 97-109. |
5 | Xu, C. and Sugiura, K. (2013), "FEM analysis on failure development of group studs shear connector under effects of concrete strength and stud dimension", Eng. Failure Anal., 3(5), 343-354. |
6 | Xue, D., Liu, Y., Yu, Z. and He, J. (2012), "Static behavior of multi-stud shear connectors for steel-concrete composite bridge", J. Constr. Steel Res., 7(4), 1-7. |
7 | Yousuf, M., Brian, U., Tao, Z., Remmenikov, A. and Richard L.J.Y. (2013), "Transverse impact resistance of hollow and concrete filled stainless steel columns", J. Constr. Steel Res., 8(2), 177-189. |
8 | Al Zand, A.W., Badaruzzaman, W.H.W., Mutalib, A.A. and Hilo, S.J. (2016), "The enhanced performance of CFST beams using different strengthening schemes involving unidirectional CFRP sheets: An experimental study", Eng. Struct., 12(8), 184-198. |
9 | An, L. and Cederwall, K. (1996), "Push-out tests on studs in high strength and normal strength concrete", J. Constr. Steel Res., 36(1), 15-29. DOI |
10 | Anagnostopoulos, C.A. (2014), "Effect of different superplasticizers on the physical and mechanical properties of cement grouts", Constr. Build. Mater., 50(1), 162-168. DOI |
11 | Arivalagan, K. (2009), "Energy absorption capacity of composite beams", J. Eng. Sci. Technol. Rev., 2(1), 145-150. |
12 | Baharom, S. and Hosseinpour, E. (2015), "Shear behavior of innovative connectors in partially encased column", Proceedings of World Congress on Advances in Structural Engineering and Mechanics (ASEM15), Incheon, Korea, August. |
13 | Classen, M., Herbrand, M., Kueres, D. and Hegger, J, (2016), "Derivation of design rules for innovative shear connectors in steel concrete composites by systematic use of nonlinear finite element analysis (FEA)", Struct. Concrete, 4(17), 646-655. |
14 | Candido-Martins, J.P.S., Costa-Neves, L.F. and Vellasco, P.C.G.d.S. (2010), "Experimental evaluation of the structural response of perfobond shear connectors", Eng Struct., 32(8), 1976-1985. DOI |
15 | Chen, S., Limazie, T. and Tan, J. (2015), "Flexural behavior of shallow cellular composite floor beams with innovative shear connections", J. Constr. Steel Res., 10(6), 329-346. |
16 | Chung, K.F. (2002), "Composite beams and floor systems fully integrated with building services", Progress in Structural Engineering and Materials, 4(2), 169-178. DOI |
17 | Chung, K.F., Ko, C.H. and Wang, A.J. (2005), "Design of steel and composite beams with web openings - verification using finite element method", Steel Compos. Struct., Int. J., 5(2-3), 203-233. DOI |
18 | Classen, M. (2015), "Shear behavior of composite dowels in transversely cracked concrete", Struct. Concrete, 6(2), 195-206. |
19 | Costa-Neves, L.F., Figueiredo, J.P., Vellasco, P.C.G.d.S. and Vianna, J.d.C. (2013), "Perforated shear connectors on composite girders under monotonic loading: An experimental approach", Eng. Struct., 5(6), 721-737. |
20 | De Nardin, S. and El Debs, A.L.H.C. (2012), Composite connections in slim-floor system: An experimental study. J. Constr. Steel Res., 68(1), 78-88. DOI |
21 | Gallwoszus, J. (2016), "Concrete fatigue in composite dowels", Struct. Concrete, 17(1), 63-73. DOI |
22 | Euro Code of practice 4 (2004), "Design of Composite Steel and Concrete Structures, part 1-1, General Rules and Rules for Buildings", European Committee for Standardization. |
23 | Euro Code of practice 4 (2005), "Design of Composite Steel and Concrete Structures, part 2, General Rules and Rules for Bridges", European Committee for Standardization. |
24 | Fontana, M. and Beck, H. (2002), "Experimental Studies on Novel Shear Rib Connectors with Powder-Actuated Fasteners", Proceedings of Composite Construction in Steel and Concrete IV, Alberta, Canada, April. |
25 | Gattesco, N. and Giuriani, E. (1996), "Experimental Study on Stud Shear connectors subjected to cyclic loading", J. Constr. Steel Res., 38(1), 1-12. DOI |
26 | Kazunori, F., Tomonori, O. and Takashi, N. (1988), "Experimental study on energy absorption capacity of reinforced concrete frames", Doboku Gakkai Ronbunshu, 390, pp. 113-121. |
27 | Han, Q., Wang, Y., Xu, J. and Xing, Y. (2015), "Static behavior of stud shear connectors in elastic concrete-steel composite beams", J. Constr. Steel Res., 11(3), 115-126. |
28 | Hegger, J. and Goralski, C. (2004), "Structural behavior of partially concrete encased composite sections with high strength cocrete", Proceedings of Composite Construction in Steel and Concrete V, Mpumalanga, South Africa, July. |
29 | Huo, B.Y. (2012), "Experimental and analytical study of the shear transfer in composite shallow cellular floor beams", Ph.D. Dissertation; City University London, London, UK. |
30 | Huo, B.Y. and D'Mello, C.A. (2013), "Push-out tests and analytical study of shear transfer mechanisms in composite challow cellular floor Beams", J. Constr. Steel Res., 8(8), 191-205. |
31 | Kuhlmann, U. and Kurschner, K. (2006), "Structural behavior of horizontally lying shear studs", Proceedings of 5th International Conference on Composite Construction in Steel and Concrete, Mpumalanga, South Africa, July, pp. 543. |
32 | Kwon, G., Engelhardt, M. and Klingner, R. (2011), "Parametric studies and preliminary design recommendations on the use of post installed shear connectors for strengthening non-composite steel bridges", J. Bridge Eng., 17(2), 310-317. DOI |
33 | Limazie, T. and Chen, S. (2016), "FE modeling and numerical investigation of shallow cellular composite floor beams", J. Constr. Steel Res., 11(9), 190-201. |
34 | Limazie, T. and Chen, S. (2017), "Effective shear connection for shallow cellular composite floor beams", Constr. Steel Res., 12(8), 772-788. |
35 | Rodrigues, F., Vellasco, P.C.G.d.S., Lima, L.R.O.d. and Andrade, S.A.L.d. (2014), "Finite element modelling of steel beams with web openings", Engineering, 6(13), 886-913. DOI |
36 | Lowe, D., Das, R. and Clifton, C. (2014), "Characterization of the splitting behavior of steel-concrete composite beams with shear stud connection", Procedia Mater. Sci., 3(1), 2174-2179. DOI |
37 | Mangerig, I. and Capfe, Z. (2003), "Concrete dowels in composite construction", Proceedings of Japanese-German Bridge Symposium, Osaka, Japan, September. |
38 | Morkhade, S.G. and Gupta, L.M. (2015), "Analysis of steel I-beams with rectangular web openings: Experimental and finite element investigation", Eng. Struct. Technol., 7(1), 13-23. DOI |
39 | Nguyen, H.T. and Kim, S.E. (2009), "Finite element modeling of push-out tests for large stud shear connectors", J. Constr. Steel Res., 65(10-11), 1909-1920. DOI |
40 | Pavlovic, M., Markovic, Z., Veljkovic, M. and Budevac, D. (2013), "Bolted shear connectors vs. headed studs behaviour in push-out tests", J. Constr. Steel Res., 8(8), 134-149. |
41 | Shariati, M., Ramli Sulong, N.H., Suhatril, M., Shariati, A., Arabnejad Khanouki, M.M. and Sinaei, H. (2013), "Comparison of behavior between channel and angle shear connectors under monotonic and fully reversed cyclic loading", Constr. Build. Mater., 3(8), 582-593. |
42 | Slim-Floor, A., Commercial Section (2007), http://www.arcelormittal.com/sections/ |
43 | Su, Q., Yang, G. and Bradford, M. (2016), "Bearing capacity of stud-bolt hybrid shear connection in segmental composite bridge girders", J. Bridge Eng., 21(4), 06015008-1-06015008-8. DOI |
44 | Tsavdaridis, K.D., D'Mello, C. and Huo, B.Y. (2013), "Experimental and computational study of the vertical shear behaviour of partially encased perforated steel beams", Eng. Struct., 5(6), 805-822. |
45 | Uenaka, K. and Higashiyama, H. (2013), "Experimental Study on Half-Pipe Shear Connectors Under Direct Shear", Proceedings of Advances in Structural Engineering and Mechanics (ASEM), Jeju, Korea, September. |
![]() |